979 resultados para Stable Distribution


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Assessments of change in subjective patient reported outcomes such as health-related quality of life (HRQoL) are a key component of many clinical and research evaluations. However, conventional longitudinal evaluation of change may not agree with patient perceived change if patients' understanding of the subjective construct under evaluation changes over time (response shift) or if patients' have inaccurate recollection (recall bias). This study examined whether older adults' perception of change is in agreement with conventional longitudinal evaluation of change in their HRQoL over the duration of their hospital stay. It also investigated this level of agreement after adjusting patient perceived change for recall bias that patients may have experienced. Methods: A prospective longitudinal cohort design nested within a larger randomised controlled trial was implemented. 103 hospitalised older adults participated in this investigation at a tertiary hospital facility. The EQ-5D utility and Visual Analogue Scale (VAS) scores were used to evaluate HRQoL. Participants completed EQ-5D reports as soon as they were medically stable (within three days of admission) then again immediately prior to discharge. Three methods of change score calculation were used (conventional change, patient perceived change and patient perceived change adjusted for recall bias). Agreement was primarily investigated using intraclass correlation coefficients (ICC) and limits of agreement. Results: Overall 101 (98%) participants completed both admission and discharge assessments. The mean (SD) age was 73.3 (11.2). The median (IQR) length of stay was 38 (20-60) days. For agreement between conventional longitudinal change and patient perceived change: ICCs were 0.34 and 0.40 for EQ-5D utility and VAS respectively. For agreement between conventional longitudinal change and patient perceived change adjusted for recall bias: ICCs were 0.98 and 0.90 respectively. Discrepancy between conventional longitudinal change and patient perceived change was considered clinically meaningful for 84 (83.2%) of participants, after adjusting for recall bias this reduced to 8 (7.9%). Conclusions: Agreement between conventional change and patient perceived change was not strong. A large proportion of this disagreement could be attributed to recall bias. To overcome the invalidating effect of response shift (on conventional change) and recall bias (on patient perceived change) a method of adjusting patient perceived change for recall bias has been described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the performance of voltage-source converter-based shunt and series compensators used for load voltage control in electrical power distribution systems has been analyzed and compared, when a nonlinear load is connected across the load bus. The comparison has been made based on the closed-loop frequency resopnse characteristics of the compensated distribution system. A distribution static compensator (DSTATCOM) as a shunt device and a dynamic voltage restorer (DVR) as a series device are considered in the voltage-control mode for the comparison. The power-quality problems which these compensator address include voltage sags/swells, load voltage harmonic distortions, and unbalancing. The effect of various system parameters on the control performance of the compensator can be studied using the proposed analysis. In particular, the performance of the two compensators are compared with the strong ac supply (stiff source) and weak ac-supply (non-still source) distribution system. The experimental verification of the analytical results derived has been obtained using a laboratory model of the single-phase DSTATCOM and DVR. A generalized converter topology using a cascaded multilevel inverter has been proposed for the medium-voltage distribution system. Simulation studies have been performed in the PSCAD/EMTDC software to verify the results in the three-phase system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optimal scheduling of voltage regulators (VRs), fixed and switched capacitors and voltage on customer side of transformer (VCT) along with the optimal allocaton of VRs and capacitors are performed using a hybrid optimisation method based on discrete particle swarm optimisation and genetic algorithm. Direct optimisation of the tap position is not appropriate since in general the high voltage (HV) side voltage is not known. Therefore, the tap setting can be determined give the optimal VCT once the HV side voltage is known. The objective function is composed of the distribution line loss cost, the peak power loss cost and capacitors' and VRs' capital, operation and maintenance costs. The constraints are limits on bus voltage and feeder current along with VR taps. The bus voltage should be maintained within the standard level and the feeder current should not exceed the feeder-rated current. The taps are to adjust the output voltage of VRs between 90 and 110% of their input voltages. For validation of the proposed method, the 18-bus IEEE system is used. The results are compared with prior publications to illustrate the benefit of the employed technique. The results also show that the lowest cost planning for voltage profile will be achieved if a combination of capacitors, VRs and VCTs is considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Global warming is already threatening many animal and plant communities worldwide, however, the effect of climate change on bat populations is poorly known. Understanding the factors influencing the survival of bats is crucial to their conservation, and this cannot be achieved solely by modern ecological studies. Palaeoecological investigations provide a perspective over a much longer temporal scale, allowing the understanding of the dynamic patterns that shaped the distribution of modern taxa. In this study twelve microchiropteran fossil assemblages from Mount Etna, central-eastern Queensland, ranging in age from more than 500,000 years to the present day, were investigated. The aim was to assess the responses of insectivorous bats to Quaternary environmental changes, including climatic fluctuations and recent anthropogenic impacts. In particular, this investigation focussed on the effects of increasing late Pleistocene aridity, the subsequent retraction of rainforest habitat, and the impact of cave mining following European settlement at Mount Etna. A thorough examination of the dental morphology of all available extant Australian bat taxa was conducted in order to identify the fossil taxa prior to their analysis in term of species richness and composition. This detailed odontological work provided new diagnostic dental characters for eighteen species and one genus. It also provided additional useful dental characters for three species and seven genera. This odontological analysis allowed the identification of fifteen fossil bat taxa from the Mount Etna deposits, all being representatives of extant bats, and included ten taxa identified to the species level (i.e., Macroderma gigas, Hipposideros semoni, Rhinolophus megaphyllus, Miniopterus schreibersii, Miniopterus australis, Scoteanax rueppellii, Chalinolobus gouldii, Chalinolobus dwyeri, Chalinolobus nigrogriseus and Vespadelus troughtoni) and five taxa identified to the generic level (i.e., Mormopterus, Taphozous, Nyctophilus, Scotorepens and Vespadelus). Palaeoecological analysis of the fossil taxa revealed that, unlike the non-volant mammal taxa, bats have remained essentially stable in terms of species diversity and community membership between the mid-Pleistocene rainforest habitat and the mesic habitat that occurs today in the region. The single major exception is Hipposideros semoni, which went locally extinct at Mount Etna. Additionally, while intensive mining operations resulted in the abandonment of at least one cave that served as a maternity roost in the recent past, the diversity of the Mount Etna bat fauna has not declined since European colonisation. The overall resilience through time of the bat species discussed herein is perhaps due to their unique ecological, behavioural, and physiological characteristics as well as their ability to fly, which have allowed them to successfully adapt to their changing environment. This study highlights the importance of palaeoecological analyses as a tool to gain an understanding of how bats have responded to environmental change in the past and provides valuable information for the conservation of threatened modern species, such as H. semoni.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

How will the digital technology revolution impact the movie business? Hollywood developed a highly successful industrial system that has functioned well for almost a century in the sense that it enabled the Major film studios to largely control and dominate the industry. However, the new digital technology may now be propelling Hollywood toward the biggest technological transition since the creation of the studio system almost a century ago. For example, Major Hollywood studios are already beginning to provide video-on-demand (VOD) digital distribution of movies over the Internet. This article examines what is happening, and why. It sets out the background and the incipient changes already occurring. It makes an argument regarding the fundamental strategic dynamics, that acetate film was the key to the control of the Hollywood system, and speculates about how a shift away from acetate film to digital video may transform that system. The focus is on the impact on how the Major studios release and market their movies, and how new market and marketing opportunities for the low-budget independent filmmaking sector may arise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Concern about skin cancer is a common reason for people from predominantly fair-skinned populations to present to primary care doctors. Objectives To examine the frequency and body-site distribution of malignant, pre-malignant and benign pigmented skin lesions excised in primary care. Methods This prospective study conducted in Queensland, Australia, included 154 primary care doctors. For all excised or biopsied lesions, doctors recorded the patient's age and sex, body site, level of patient pressure to excise, and the clinical diagnosis. Histological confirmation was obtained through pathology laboratories. Results Of 9650 skin lesions, 57·7% were excised in males and 75·0% excised in patients ≥50years. The most common diagnoses were basal cell carcinoma (BCC) (35·1%) and squamous cell carcinoma (SCC) (19·7%). Compared with the whole body, the highest densities for SCC, BCC and actinic keratoses were observed on chronically sun-exposed areas of the body including the face in males and females, the scalp and ears in males, and the hands in females. The density of BCC was also high on intermittently or rarely exposed body sites. Females, younger patients and patients with melanocytic naevi were significantly more likely to exert moderate/high levels of pressure on the doctor to excise. Conclusions More than half the excised lesions were skin cancer, which mostly occurred on the more chronically sun-exposed areas of the body. Information on the type and body-site distribution of skin lesions can aid in the diagnosis and planned management of skin cancer and other skin lesions commonly presented in primary care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We explored the feasibility of community pharmacies for the distribution of chlamydia specimen self-collection kits, which featured a transport medium allowing postage of urine specimens in Australia. Eligible clients were requested to complete a code-matched risk-screening questionnaire in the pharmacy, and the derived risk scores were compared to the test results from the corresponding specimen. Four Queensland pharmacies distributed 156 kits, while 44 questionnaires and 18 specimens were received.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we consider the case of large cooperative communication systems where terminals use the protocol known as slotted amplify-and-forward protocol to aid the source in its transmission. Using the perturbation expansion methods of resolvents and large deviation techniques we obtain an expression for the Stieltjes transform of the asymptotic eigenvalue distribution of a sample covariance random matrix of the type HH† where H is the channel matrix of the transmission model for the transmission protocol we consider. We prove that the resulting expression is similar to the Stieltjes transform in its quadratic equation form for the Marcenko-Pastur distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of stable isotope ratios δ18O and δ2H are well established in assessment of groundwater systems and their hydrology. The conventional approach is based on x/y plots and relation to various MWL’s, and plots of either ratio against parameters such as Clor EC. An extension of interpretation is the use of 2D maps and contour plots, and 2D hydrogeological vertical sections. An enhancement of presentation and interpretation is the production of “isoscapes”, usually as 2.5D surface projections. We have applied groundwater isotopic data to a 3D visualisation, using the alluvial aquifer system of the Lockyer Valley. The 3D framework is produced in GVS (Groundwater Visualisation System). This format enables enhanced presentation by displaying the spatial relationships and allowing interpolation between “data points” i.e. borehole screened zones where groundwater enters. The relative variations in the δ18O and δ2H values are similar in these ambient temperature systems. However, δ2H better reflects hydrological processes, whereas δ18O also reflects aquifer/groundwater exchange reactions. The 3D model has the advantage that it displays borehole relations to spatial features, enabling isotopic ratios and their values to be associated with, for example, bedrock groundwater mixing, interaction between aquifers, relation to stream recharge, and to near-surface and return irrigation water evaporation. Some specific features are also shown, such as zones of leakage of deeper groundwater (in this case with a GAB signature). Variations in source of recharging water at a catchment scale can be displayed. Interpolation between bores is not always possible depending on numbers and spacing, and by elongate configuration of the alluvium. In these cases, the visualisation uses discs around the screens that can be manually expanded to test extent or intersections. Separate displays are used for each of δ18O and δ2H and colour coding for isotope values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a comprehensive approach to the planning of distribution networks and the control of microgrids. Firstly, a Modified Discrete Particle Swarm Optimization (MDPSO) method is used to optimally plan a distribution system upgrade over a 20 year planning period. The optimization is conducted at different load levels according to the anticipated load duration curve and integrated over the system lifetime in order to minimize its total lifetime cost. Since the optimal solution contains Distributed Generators (DGs) to maximize reliability, the DG must be able to operate in islanded mode and this leads to the concept of microgrids. Thus the second part of the paper reviews some of the challenges of microgrid control in the presence of both inertial (rotating direct connected) and non-inertial (converter interfaced) DGs. More specifically enhanced control strategies based on frequency droop are proposed for DGs to improve the smooth synchronization and real power sharing minimizing transient oscillations in the microgrid. Simulation studies are presented to show the effectiveness of the control.