990 resultados para Single lung ventilation
Resumo:
A mathematical model is presented that describes a system where two consumer species compete exploitatively for a single renewable resource. The resource is distributed in a patchy but homogeneous environment; that is, all patches are intrinsically identical. The two consumer species are referred to as diggers and grazers, where diggers deplete the resource within a patch to lower densities than grazers. We show that the two distinct feeding strategies can produce a heterogeneous resource distribution that enables their coexistence. Coexistence requires that grazers must either move faster than diggers between patches or convert the resources to population growth much more efficiently than diggers. The model shows that the functional form of resource renewal within a patch is also important for coexistence. These results contrast with theory that considers exploitation competition for a single resource when the resource is assumed to be well mixed throughout the system.
Resumo:
Obstruction of the fetal trachea is a potent stimulus for fetal lung growth and may have therapeutic potential in human fetuses with lung hypoplasia. However, the effects of increased lung expansion on lung development near midgestation, which is the preferred timing for fetal intervention, have not been well studied. Our aim was to determine the effects of increased lung expansion on lung development at 75-90 d of gestation in fetal sheep. In three groups of fetuses (n = 4 for each), the trachea was occluded for either 10 [10-d tracheal occlusion (TO) group] or 15 d (15-d TO group) or left intact (control fetuses). TO for both 10 and 15 d caused fetal hydrops, resulting in significantly increased fetal body weights. Both periods of TO significantly increased total lung DNA contents from 99.8 +/- 10.1 to 246.0 +/- 5.3 and 246.9 +/- 48.7 mg in 10- and 15-d TO fetuses, respectively. TO for 10 and 15 d also increased airspace diameter, although the percentage of lung occupied by airspace was not increased in 10-d TO fetuses due to large increases in interairway distances; this resulted from a large increase in mesenchymal tissue. The interairway distances at 15 d of TO were reduced compared with the 10-d value but were still similar to 30% larger than control values. We conclude that TO at
Resumo:
We propose a single optical photon source for quantum cryptography based on the acoustoelectric effect. Surface acoustic waves (SAWs) propagating through a quasi-one-dimensional channel have been shown to produce packets of electrons that reside in the SAW minima and travel at the velocity of sound. In our scheme, the electron packets are injected into a p-type region, resulting in photon emission. Since the number of electrons in each packet can be controlled down to a single electron, a stream of single- (or N-) photon states, with a creation time strongly correlated with the driving acoustic field, should be generated.
Resumo:
Objective: To pilot a single-patient trials (SPTs) service in general practice, designed to improve decision-making about long-term medications for chronic conditions. Design: 12-week within-patient, randomised, double-blind, placebo-controlled, crossover comparison of ibuprofen with paracetamol for osteoarthritis, involving three pairs of two-week treatment periods for each participating patient. Setting and patients: Patients attending an academic general practice with a clinical diagnosis of osteoarthritis, with pain of at least a month's duration severe enough to warrant consideration of long-term non-steroidal anti-inflammatory drug (NSAID) use. Main outcome measures: Pain and stiffness; measures of overall arthritis compared with previous fortnight; preference for NSAID at the end of each two-week treatment period; use of escape analgesia; side effects; and management changes as a result of the SPTs. Results: Eight of 14 patients completed SPTs. One was a clear responder to NSAIDs, five were non-responders, and two were indefinite. Of the five who were using NSAIDs before the SPT, two continued and three ceased using them. Clinically useful information assisted decision-making for all eight participants. Medication management changed for six. Conclusions: Single-patient trials can be successfully implemented in general practice and might be a valuable method for GPs to identify patients who respond to medication for chronic stable conditions such as osteoarthritis, in which individual response to medication is variable.
Resumo:
The influence of initial perturbation geometry and material propel-ties on final fold geometry has been investigated using finite-difference (FLAC) and finite-element (MARC) numerical models. Previous studies using these two different codes reported very different folding behaviour although the material properties, boundary conditions and initial perturbation geometries were similar. The current results establish that the discrepancy was not due to the different computer codes but due to the different strain rates employed in the two previous studies (i.e. 10(-6) s(-1) in the FLAC models and 10(-14) s(-1) in the MARC models). As a result, different parts of the elasto-viscous rheological field were bring investigated. For the same material properties, strain rate and boundary conditions, the present results using the two different codes are consistent. A transition in Folding behaviour, from a situation where the geometry of initial perturbation determines final fold shape to a situation where material properties control the final geometry, is produced using both models. This transition takes place with increasing strain rate, decreasing elastic moduli or increasing viscosity (reflecting in each case the increasing influence of the elastic component in the Maxwell elastoviscous rheology). The transition described here is mechanically feasible but is associated with very high stresses in the competent layer (on the order of GPa), which is improbable under natural conditions. (C) 2000 Elsevier Science Ltd. All rights reserved.
Resumo:
We consider continuous observation of the nonlinear dynamics of single atom trapped in an optical cavity by a standing wave with intensity modulation. The motion of the atom changes the phase of the field which is then monitored by homodyne detection of the output field. We show that the conditional Hilbert space dynamics of this system, subject to measurement-induced perturbations, depends strongly on whether the corresponding classical dynamics is regular or chaotic. If the classical dynamics is chaotic, the distribution of conditional Hilbert space vectors corresponding to different observation records tends to be orthogonal. This is a characteristic feature of hypersensitivity to perturbation for quantum chaotic systems.
Resumo:
Objective: To review the epidemiological evidence for the association between passive smoking and lung cancer. Method: Primary studies and meta-analyses examining the relationship between passive smoking and lung cancer were identified through a computerised literature search of Medline and Embase, secondary references, and experts in the field of passive smoking. Primary studies meeting the inclusion criteria were meta-analysed. Results From 1981 to the end of 1999 there have been 76 primary epidemiological studies of passive smoking and lung cancer, and 20 meta-analyses. There were 43 primary studies that met the inclusion criteria for this meta-analysis; more studies than previous assessments. The pooled relative risk (RR) for never-smoking women exposed to environmental tobacco smoke (ETS) from spouses, compared with unexposed never-smoking women was 1.29 (95% CI 1.17-1.43). Sequential cumulative meta-analysed results for each year from 1981 were calculated: since 1992 the RR has been greater than 1.25. For Western industrialised countries the RR for never-smoking women exposed to ETS compared with unexposed never-smoking women, was 1.21 (95% CI 1.10-1.33). Previously published international spousal meta-analyses have all produced statistically significant RRs greater than 1.17. Conclusions The abundance of evidence in this paper, and the consistency of findings across domestic and workplace primary studies, dosimetric extrapolations and meta-analyses, clearly indicates that non-smokers exposed to ETS are at increased risk of lung cancer. Implications: The recommended public health policy is for a total ban on smoking in enclosed public places and work sites.
Resumo:
Background: Although there is evidence demonstrating an association between chronic obstructive pulmonary disease (COPD) and abdominal aortic aneurysm (AAA), it is not clear whether COPD predicts greater rates of expansion of established aneurysms. We sought such an association in a cohort of men with aneurysms detected in a population-based study of screening for aneurysms. Methods: In addition to regular aortic ultrasound scans, 179 men with AAA underwent full lung function testing in order to identify the presence of COPD and its subgroups, emphysema and other obstructive ventilatory defects (OVD). The rate of expansion of each aneurysm was calculated and the men were divided into 'rapid expanders' (3 mm or more per year) and 'slow expanders' (less than 3 mm per year). Any association with the presence of COPD or smoking was tested using a multivariate model. Results: Over a median follow-up period of 36 months the mean rate of aortic expansion for the cohort of 179 men was 2.1 mm/year. There was no significant difference in prevalence of COPD (68% overall) or having ever been a smoker (87% overall) between the rapid expanders and the slow expanders. Conclusions: Although there was a high prevalence of COPD among men with an AAA, there was no association between the rate of expansion of AAA and the presence of any form of this disease.
Resumo:
We investigated the recruitment behaviour of low threshold motor units in flexor digitorum superficialis by altering two biomechanical constraints: the load against which the muscle worked and the initial muscle length. The load was increased using isotonic (low load), loaded dynamic (intermediate load) and isometric (high load) contractions in two studies. The initial muscle position reflected resting muscle length in series A, and a longer length with digit III fully extended in series B. Intramuscular EMG was recorded from 48 single motor units in 10 experiments on five healthy subjects, 21 units in series A and,27 in series B, while subjects performed ramp up, hold and ramp down contractions. Increasing the load on the muscle decreased the force, displacement and firing rate of single motor units at recruitment at shorter muscle lengths (P < 0.001, dependent t-test). At longer muscle lengths this recruitment pattern was observed between loaded dynamic and isotonic contractions, but not between isometric and loaded dynamic contractions. Thus, the recruitment properties of single motor units in human flexor digitorum superficialis are sensitive to changes in both imposed external loads and the initial length of the muscle. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
Positive end expiratory pressure (PEEP) is important for neonatal ventilation but is not considered in guidelines for resuscitation. Our aim was to investigate the effects of PEEP on cardiorespiratory parameters during resuscitation of very premature lambs delivered by hysterotomy at similar to125 d gestation (term similar to147 d). Before delivery, they were intubated and lung fluid was drained. Immediately after delivery, they were ventilated with a Drager Babylog plus ventilator in volume guarantee mode with a tidal volume of 5 mL/kg. Lambs were randomized to receive 0, 4, 8, or 12 cm H2O of PEEP. They were ventilated for a 15-min resuscitation period followed by 2 h of stabilization at the same PEEP. Tidal volume, peak inspiratory pressure, PEEP, arterial pressure, oxygen saturation, and blood gases were measured regularly, and respiratory system compliance and alveolar/ arterial oxygen differences were calculated. Lambs that received 12 cm H2O of PEEP died from pneumothoraces; all others survived without pneumothoraces. Oxygenation was significantly improved by 8 and 12 cm H2O of PEEP compared with 0 and 4 cm H2O of PEEP. Lambs with 0 PEEP did not oxygenate adequately. The compliance of the respiratory system was significantly higher at 4 and 8 cm H2O of PEEP than at 0 PEEP. There were no significant differences in partial pressure of carbon dioxide in arterial blood between groups. Arterial pressure was highest with 8 cm H2O of PEEP, and there was no cardiorespiratory compromise at any level of PEEP. Applying PEEP during resuscitation of very premature infants might be advantageous and merits further investigation.
Resumo:
Background: Over-ventilation causing low arterial carbon dioxide levels (PaCO2) has been associated with the development of neonatal chronic lung disease and adverse outcomes. This may occur very soon after birth. Aim: To investigate the effect on PaCO2 and oxygenation of very premature lambs resuscitated with different tidal volumes and PEEP. Methods: Anaesthetised lambs delivered at 126 days gestation were randomised to 15 min resuscitation with 3 regimes: (1) Laerdal resuscitation bag (B) with 100% oxygen and no PEEP, (2) fixed tidal volume (VT) of 5 mL/kg, or (3) VT of 10 mL/kg, both delivered with a Babylog 8000 ventilator in volume guarantee mode with 8 cm H2O PEEP and variable FiO2. Frequent blood gases were measured and VT, mean airway pressure (Paw), minute volume (MV), ventilation rate (VR), respiratory system compliance (Crs) and alveolar/arterial oxygen difference (AaDO2) were recorded. Results: Twenty lambs were studied. B (1) was associated with more variable VT and peak inspiratory pressures (PIP) compared to fixed tidal volumes (2 and 3). The lambs ventilated with 10 mL/kg were over-ventilated, those ventilated with 5 mL/kg were slightly under-ventilated. Those ventilated with the Laerdal bag had a mean VT of 7.5 mL/kg and were normocarbic. The different tidal volumes had little effect on oxygenation. PEEP improved oxygenation. The table shows the values at 15 minutes expressed as mean and SEM. TABLE. No caption av... TABLE. No caption av... Image Tools Conclusion: Very premature lambs can be effectively resuscitated from birth using volume guarantee ventilation. Within minutes of birth different tidal volumes had a large effect on PaCO2 and no effect on oxygenation. Studies are needed to determine the appropriate tidal volume for resuscitating very premature infants to maintain acceptable levels of PaCO2. © International Pediatrics Research Foundation, Inc. 2004. All Rights Reserved.