982 resultados para Simulazione dinamica swirl motori Diesel


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Given the current energy crisis experienced in our country with the lack of rain in some areas, the energy distributors were forced to resort to thermal power plants to complement their energy production; raising the cost of electricity generation, they have been forced to repass this value to the customers through the Tariff Flags. Concerned about a substantial increase in their electric bill, some consumers were forced to look for alternatives so that their results are not affected. The use of diesel generation at peak hours is a relatively simple and inexpensive alternative that has been widely used for several industrial, commercial and service customers. In this present work, we conducted a feasibility study of the use of diesel generators at peak hours in a medium-sized hospital, calculating the depreciation period for the investment through savings in electricity bills

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Starting induction motors on isolated or weak systems is a highly dynamic process that can cause motor and load damage as well as electrical network fluctuations. Mechanical damage is associated with the high starting current drawn by a ramping induction motor. In order to compensate the load increase, the voltage of the electrical system decreases. Different starting methods can be applied to the electrical system to reduce these and other starting method issues. The purpose of this thesis is to build accurate and usable simulation models that can aid the designer in making the choice of an appropriate motor starting method. The specific case addressed is the situation where a diesel-generator set is used as the electrical supplied source to the induction motor. The most commonly used starting methods equivalent models are simulated and compared to each other. The main contributions of this thesis is that motor dynamic impedance is continuously calculated and fed back to the generator model to simulate the coupling of the electrical system. The comparative analysis given by the simulations has shown reasonably similar characteristics to other comparative studies. The diesel-generator and induction motor simulations have shown good results, and can adequately demonstrate the dynamics for testing and comparing the starting methods. Further work is suggested to refine the equivalent impedance presented in this thesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Given the current energy crisis experienced in our country with the lack of rain in some areas, the energy distributors were forced to resort to thermal power plants to complement their energy production; raising the cost of electricity generation, they have been forced to repass this value to the customers through the Tariff Flags. Concerned about a substantial increase in their electric bill, some consumers were forced to look for alternatives so that their results are not affected. The use of diesel generation at peak hours is a relatively simple and inexpensive alternative that has been widely used for several industrial, commercial and service customers. In this present work, we conducted a feasibility study of the use of diesel generators at peak hours in a medium-sized hospital, calculating the depreciation period for the investment through savings in electricity bills

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Due to their toxicity, diesel emissions have been submitted to progressively more restrictive regulations in developed countries. However, in Brazil, the implementation of the Cleaner Diesel Technologies policy (Euro IV standards for vehicles produced in 2009 and low-sulfur diesel with 50 ppm of sulfur) was postponed until 2012 without a comprehensive analysis of the effect of this delay on public health parameters. We aimed to evaluate the impact of the delay in implementing the Cleaner Diesel Technologies policy on health indicators and monetary health costs in Brazil. METHODS: The primary estimator of exposure to air pollution was the concentration of ambient fine particulate matter (particles with aerodynamic diameters, <2.5 mu m, [PM2.5]). This parameter was measured daily in six Brazilian metropolitan areas during 2007-2008. We calculated 1) the projected reduction in the PM2.5 that would have been achieved if the Euro IV standards had been implemented in 2009 and 2) the expected reduction after implementation in 2012. The difference between these two time curves was transformed into health outcomes using previous dose-response curves. The economic valuation was performed based on the DALY (disability-adjusted life years) method. RESULTS: The delay in implementing the Cleaner Diesel Technologies policy will result in an estimated excess of 13,984 deaths up to 2040. Health expenditures are projected to be increased by nearly US$ 11.5 billion for the same period. CONCLUSIONS: The present results indicate that a significant health burden will occur because of the postponement in implementing the Cleaner Diesel Technologies policy. These results also reinforce the concept that health effects must be considered when revising fuel and emission policies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, particulate matter (PM) were characterized from a place impacted by heavy-duty vehicles (Bus Station) fuelled with diesel/biodiesel fuel blend (B3) in the city of Londrina, Brazil. Sixteen priority polycyclic aromatic hydrocarbons (PAH) concentrations were analyzed in the samples by their association with atmospheric PM, mass size distributions and major ions (fluorite, chloride, bromide, nitrate, phosphate, sulfate, nitrite, oxalate; fumarate, formate, succinate and acetate; lithium, sodium, potassium, magnesium, calcium and ammonium). Results indicate that major ions represented 21.2% particulate matter mass. Nitrate, sulfate, and ammonium, respectively, presented the highest concentration levels, indicating that biodiesel may also be a significant source for these ions, especially nitrate. Dibenzo[a,h]anthracene and indeno[1,2,3,-cd]pyrene were the main PAH found, and a higher fraction of PAH particles was found in diameters lower than 0.25 mu m in Londrina bus station. The fine and ultrafine particles were dominant among the PM evaluated, suggesting that biodiesel decreases the total PAH emission. However, it does also increase the fraction of fine and ultrafine particles when compared to diesel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe production of methyl and ethyl esters derived from baru oil (Dipteryx alata Vog.). Water and alcohols are removed from the biodiesel obtained by simple distillation. We study the acidity, density, iodine number, viscosity, water content, peroxide number, external appearance, and saponification number of the oil, its methyl and ethyl esters (biodiesels) and their blends (B5, B10, B15, B20, and B30) with commercial diesel fuel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zin WA, Silva AG, Magalhaes CB, Carvalho GM, Riva DR, Lima CC, Leal-Cardoso JH, Takiya CM, Valen a SS, Saldiva PH, Faffe DS. Eugenol attenuates pulmonary damage induced by diesel exhaust particles. J Appl Physiol 112: 911-917, 2012. First published December 22, 2011; doi: 10.1152/japplphysiol.00764.2011.-Environmentally relevant doses of inhaled diesel particles elicit pulmonary inflammation and impair lung mechanics. Eugenol, a methoxyphenol component of clove oil, presents in vitro and in vivo anti-inflammatory and antioxidant properties. Our aim was to examine a possible protective role of eugenol against lung injuries induced by diesel particles. Male BALB/c mice were divided into four groups. Mice received saline (10 mu l in; CTRL group) or 15 mu g of diesel particles DEP (15 mu g in; DIE and DEUG groups). After 1 h, mice received saline (10 mu l; CTRL and DIE groups) or eugenol (164 mg/kg; EUG and DEUG group) by gavage. Twenty-four hours after gavage, pulmonary resistive (Delta P1), viscoelastic (Delta P2) and total (Delta Ptot) pressures, static elastance (Est), and viscoelastic component of elastance (Delta E) were measured. We also determined the fraction areas of normal and collapsed alveoli, amounts of polymorpho- (PMN) and mononuclear cells in lung parenchyma, apoptosis, and oxidative stress. Est, Delta P2, Delta Ptot, and Delta E were significantly higher in the DIE than in the other groups. DIE also showed significantly more PMN, airspace collapse, and apoptosis than the other groups. However, no beneficial effect on lipid peroxidation was observed in DEUG group. In conclusion, eugenol avoided changes in lung mechanics, pulmonary inflammation, and alveolar collapse elicited by diesel particles. It attenuated the activation signal of caspase-3 by DEP, but apoptosis evaluated by TUNEL was avoided. Finally, it could not avoid oxidative stress as indicated by malondialdehyde.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The designation of biodiesel as an environmental-friendly alternative to diesel oil has improved its commercialization and use. However, most biodiesel environmental safety studies refer to air pollution and so far there have been very few literature data about its impacts upon other biotic systems, e.g. water, and exposed organisms. Spill simulations in water were carried out with neat diesel and biodiesel and their blends aiming at assessing their genotoxic potentials should there be contaminations of water systems. The water soluble fractions (WSF) from the spill simulations were submitted to solid phase extraction with C-18 cartridge and the extracts obtained were evaluated carrying out genotoxic and mutagenic bioassays [the Salmonella assay and the in vitro MicroFlow (R) kit (Litron) assay]. Mutagenic and genotoxic effects were observed, respectively, in the Salmonella/microsome preincubation assay and the in vitro MN test carried out with the biodiesel WSF. This interesting result may be related to the presence of pollutants in biodiesel derived from the raw material source used in its production chain. The data showed that care while using biodiesel should be taken to avoid harmful effects on living organisms in cases of water pollution. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[ES] En este trabajo se describe el desgaste adhesivo (scuffing) que representa la más severa de las agresiones a la que se ven expuestos aros de pistón y camisas de cilindro de motores diésel lentos de dos tiempos aplicados a la generación eléctrica, al quemar combustibles de bajo contenido en azufre. Al afectar simultáneamente, a estos dos elementos básicos de la cámara de combustión, repercute negativamente tanto en la continuidad del servicio del motor, como en los costes asociados a la restitución de las condiciones nominales de trabajo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Durante il periodo di dottorato, l’attività di ricerca di cui mi sono occupato è stata finalizzata allo sviluppo di metodologie per la diagnostica e l’analisi delle prestazioni di un motore automobilistico. Un primo filone di ricerca è relativo allo sviluppo di strategie per l’identificazione delle mancate combustioni (misfires) in un motore a benzina. La sperimentazione si è svolta nella sala prove della Facoltà di Ingegneria dell’Università di Bologna, nei quali è presente un motore Fiat 1.200 Fire, accoppiato ad un freno a correnti parassite, e comandato da una centralina virtuale, creata mediante un modello Simulink, ed interfacciata al motore tramite una scheda di input/output dSpace. Per quanto riguarda la campagna sperimentale, sono stati realizzati delle prove al banco in diverse condizioni di funzionamento (sia stazionarie, che transitorie), durante le quali sono stati indotti dei misfires, sia singoli che multipli. Durante tali test sono stati registrati i segnali provenienti sia dalla ruota fonica usata per il controllo motore (che, nel caso in esame, era affacciata al volano), sia da quella collegata al freno a correnti parassite. Partendo da tali segnali, ed utilizzando un modello torsionale del sistema motoregiunto-freno, è possibile ottenere una stima sia della coppia motrice erogata dal motore, sia della coppia resistente dissipata dal freno. La prontezza di risposta di tali osservatori è tale da garantirci la possibilità di effettuare una diagnosi misfire. In particolare, si è visto che l’indice meglio correlato ala mancata combustione risultaessere la differenza fra la coppia motrice e la coppia resistente; tale indice risulta inoltre essere quello più semplice da calibrare sperimentalmente, in quanto non dipende dalle caratteristiche del giunto, ma solamente dalle inerzie del sistema. Una seconda attività della quale mi sono occupato è relativa alla stima della coppia indicata in un motore diesel automobilistico. A tale scopo, è stata realizzata una campagna sperimentale presso i laboratori della Magneti Marelli Powertrain (Bologna), nella quale sono state effettuati test in molteplici punti motori, sia in condizioni di funzionamento “nominale”, sia variando artificiosamente alcuni dei fattori di controllo (quali Start of Injection, pressione nel rail e, nei punti ove è stato possibile, tasso di EGR e pressione di sovralimentazione), sia effettuando degli sbilanciamenti di combustibile fra un cilindro e l’altro. Utilizzando il solo segnale proveniente da una ruota fonica posta sul lato motore, e sfruttando un modello torsionale simile a quello utilizzato nella campagna di prove relativa alla diagnosi del misfire, è possibile correlare la componente armonica con frequenza di combustione della velocità all’armonica di pari ordine della coppia indicata; una volta stimata tale componente in frequenza, mediante un’analisi di tipo statistico, è possibile eseguire una stima della coppia indicata erogata dal motore. A completamento dell’algoritmo, sfruttando l’analisi delle altre componenti armoniche presenti nel segnale, è possibile avere una stima dello sbilanciamento di coppia fra i vari cilindri. Per la verifica dei risultati ottenuti, sono stati acquisiti i segnali di pressione provenienti da tutti e quattro i cilindri del motore in esame.