907 resultados para R-MATRIX METHOD


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Finding genes that are differentially expressed between conditions is an integral part of understanding the molecular basis of phenotypic variation. In the past decades, DNA microarrays have been used extensively to quantify the abundance of mRNA corresponding to different genes, and more recently high-throughput sequencing of cDNA (RNA-seq) has emerged as a powerful competitor. As the cost of sequencing decreases, it is conceivable that the use of RNA-seq for differential expression analysis will increase rapidly. To exploit the possibilities and address the challenges posed by this relatively new type of data, a number of software packages have been developed especially for differential expression analysis of RNA-seq data. RESULTS: We conducted an extensive comparison of eleven methods for differential expression analysis of RNA-seq data. All methods are freely available within the R framework and take as input a matrix of counts, i.e. the number of reads mapping to each genomic feature of interest in each of a number of samples. We evaluate the methods based on both simulated data and real RNA-seq data. CONCLUSIONS: Very small sample sizes, which are still common in RNA-seq experiments, impose problems for all evaluated methods and any results obtained under such conditions should be interpreted with caution. For larger sample sizes, the methods combining a variance-stabilizing transformation with the 'limma' method for differential expression analysis perform well under many different conditions, as does the nonparametric SAMseq method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Segmenting ultrasound images is a challenging problemwhere standard unsupervised segmentation methods such asthe well-known Chan-Vese method fail. We propose in thispaper an efficient segmentation method for this class ofimages. Our proposed algorithm is based on asemi-supervised approach (user labels) and the use ofimage patches as data features. We also consider thePearson distance between patches, which has been shown tobe robust w.r.t speckle noise present in ultrasoundimages. Our results on phantom and clinical data show avery high similarity agreement with the ground truthprovided by a medical expert.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a novel numerical approach for the comprehensive, flexible, and accurate simulation of poro-elastic wave propagation in cylindrical coordinates. An important application of this method is the modeling of complex seismic wave phenomena in fluid-filled boreholes, which represents a major, and as of yet largely unresolved, computational problem in exploration geophysics. In view of this, we consider a numerical mesh consisting of three concentric domains representing the borehole fluid in the center, the borehole casing and the surrounding porous formation. The spatial discretization is based on a Chebyshev expansion in the radial direction, Fourier expansions in the other directions, and a Runge-Kutta integration scheme for the time evolution. A domain decomposition method based on the method of characteristics is used to match the boundary conditions at the fluid/porous-solid and porous-solid/porous-solid interfaces. The viability and accuracy of the proposed method has been tested and verified in 2D polar coordinates through comparisons with analytical solutions as well as with the results obtained with a corresponding, previously published, and independently benchmarked solution for 2D Cartesian coordinates. The proposed numerical solution also satisfies the reciprocity theorem, which indicates that the inherent singularity associated with the origin of the polar coordinate system is handled adequately.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[spa] La implementación de un programa de subvenciones públicas a proyectos empresariales de I+D comporta establecer un sistema de selección de proyectos. Esta selección se enfrenta a problemas relevantes, como son la medición del posible rendimiento de los proyectos de I+D y la optimización del proceso de selección entre proyectos con múltiples y a veces incomparables medidas de resultados. Las agencias públicas utilizan mayoritariamente el método peer review que, aunque presenta ventajas, no está exento de críticas. En cambio, las empresas privadas con el objetivo de optimizar su inversión en I+D utilizan métodos más cuantitativos, como el Data Envelopment Análisis (DEA). En este trabajo se compara la actuación de los evaluadores de una agencia pública (peer review) con una metodología alternativa de selección de proyectos como es el DEA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[spa] La implementación de un programa de subvenciones públicas a proyectos empresariales de I+D comporta establecer un sistema de selección de proyectos. Esta selección se enfrenta a problemas relevantes, como son la medición del posible rendimiento de los proyectos de I+D y la optimización del proceso de selección entre proyectos con múltiples y a veces incomparables medidas de resultados. Las agencias públicas utilizan mayoritariamente el método peer review que, aunque presenta ventajas, no está exento de críticas. En cambio, las empresas privadas con el objetivo de optimizar su inversión en I+D utilizan métodos más cuantitativos, como el Data Envelopment Análisis (DEA). En este trabajo se compara la actuación de los evaluadores de una agencia pública (peer review) con una metodología alternativa de selección de proyectos como es el DEA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[spa] La implementación de un programa de subvenciones públicas a proyectos empresariales de I+D comporta establecer un sistema de selección de proyectos. Esta selección se enfrenta a problemas relevantes, como son la medición del posible rendimiento de los proyectos de I+D y la optimización del proceso de selección entre proyectos con múltiples y a veces incomparables medidas de resultados. Las agencias públicas utilizan mayoritariamente el método peer review que, aunque presenta ventajas, no está exento de críticas. En cambio, las empresas privadas con el objetivo de optimizar su inversión en I+D utilizan métodos más cuantitativos, como el Data Envelopment Análisis (DEA). En este trabajo se compara la actuación de los evaluadores de una agencia pública (peer review) con una metodología alternativa de selección de proyectos como es el DEA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Over the last 10 years, diffusion-weighted imaging (DWI) has become an important tool to investigate white matter (WM) anomalies in schizophrenia. Despite technological improvement and the exponential use of this technique, discrepancies remain and little is known about optimal parameters to apply for diffusion weighting during image acquisition. Specifically, high b-value diffusion-weighted imaging known to be more sensitive to slow diffusion is not widely used, even though subtle myelin alterations as thought to happen in schizophrenia are likely to affect slow-diffusing protons. Schizophrenia patients and healthy controls were scanned with a high b-value (4000s/mm(2)) protocol. Apparent diffusion coefficient (ADC) measures turned out to be very sensitive in detecting differences between schizophrenia patients and healthy volunteers even in a relatively small sample. We speculate that this is related to the sensitivity of high b-value imaging to the slow-diffusing compartment believed to reflect mainly the intra-axonal and myelin bound water pool. We also compared these results to a low b-value imaging experiment performed on the same population in the same scanning session. Even though the acquisition protocols are not strictly comparable, we noticed important differences in sensitivities in the favor of high b-value imaging, warranting further exploration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

R commands to calculate the secondary production estimates using the size-frequency method after Hynes and Coleman (1968), Benke (1979) and Huryn (1996).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we analyse, using Monte Carlo simulation, the possible consequences of incorrect assumptions on the true structure of the random effects covariance matrix and the true correlation pattern of residuals, over the performance of an estimation method for nonlinear mixed models. The procedure under study is the well known linearization method due to Lindstrom and Bates (1990), implemented in the nlme library of S-Plus and R. Its performance is studied in terms of bias, mean square error (MSE), and true coverage of the associated asymptotic confidence intervals. Ignoring other criteria like the convenience of avoiding over parameterised models, it seems worst to erroneously assume some structure than do not assume any structure when this would be adequate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: SIOPEN scoring of 123I mIBG imaging has been shown to predict response to induction chemotherapy and outcome at diagnosis in children with HRN.Method: Patterns of skeletal 123I mIBG uptake were assigned numerical scores (Mscore) ranging from 0 (no metastasis) to 72 (diffuse metastases) within 12 body areas as described previously. 271 anonymised, paired image data sets acquired at diagnosis and on completion of Rapid COJEC induction chemotherapy were reviewed, constituting a representative sample of 1602 children treated prospectively within the HR-NBL1/SIOPEN trial. Pre-and post-treatment Mscores were compared with bone marrow cytology (BM) and 3 year event free survival (EFS).Results: Results 224/271 patients showed skeletal MIBG-uptake at diagnosis and were evaluable forMIBG-response. Complete response (CR) on MIBG to Rapid COJEC induction was achieved by 66%, 34% and 15% of patients who had pre-treatment Mscores of <18 (n¼65, 29%), 18-44 (n¼95,42%) and Y ´ 45 (n¼64, 28.5%) respectively (chi squared test p<.0001). Mscore at diagnosis and on completion of Rapid COJEC correlated strongly with BM involvement (p<0.0001). The correlation of pre score with post scores and response was highly significant (p<0.001). Most importantly, the 3 year EFS in 47 children with Mscore 0 at diagnosis was 0.68 (A ` 0.07), by comparison with 0.42 (A` 0.06), 0.35 (A` 0.05) and 0.25 (A` 0.06) for patients in pre-treatment score groups <18, 18-44 and Y ´ 45, respectively (p<0.001). AnMscore threshold ofY ´ 45 at diagnosis was associated with significantly worse outcome by comparison with all other Mscore groups (p¼0.029). The 3 year EFS of 0.53 (A` 0.07) of patients in metastatic CR (mIBG and BM) after Rapid Cojec (33%) is clearly superior to patients not achieving metastatic CR (0.24 (A ` 0.04), p¼0.005).Conclusion: SIOPEN scoring of 123I mIBG imaging has been shown to predict response to induction chemotherapy and outcome at diagnosis in children with HRN.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The extension of density functional theory (DFT) to include pairing correlations without formal violation of the particle-number conservation condition is described. This version of the theory can be considered as a foundation of the application of existing DFT plus pairing approaches to atoms, molecules, ultracooled and magnetically trapped atomic Fermi gases, and atomic nuclei where the number of particles is conserved exactly. The connection with Hartree-Fock-Bogoliubov (HFB) theory is discussed, and the method of quasilocal reduction of the nonlocal theory is also described. This quasilocal reduction allows equations of motion to be obtained which are much simpler for numerical solution than the equations corresponding to the nonlocal case. Our theory is applied to the study of some even Sn isotopes, and the results are compared with those obtained in the standard HFB theory and with the experimental ones.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To describe a method to obtain a profile of the duration and intensity (speed) of walking periods over 24 hours in women under free-living conditions. DESIGN: A new method based on accelerometry was designed for analyzing walking activity. In order to take into account inter-individual variability of acceleration, an individual calibration process was used. Different experiments were performed to highlight the variability of acceleration vs walking speed relationship, to analyze the speed prediction accuracy of the method, and to test the assessment of walking distance and duration over 24-h. SUBJECTS: Twenty-eight women were studied (mean+/-s.d.) age: 39.3+/-8.9 y; body mass: 79.7+/-11.1 kg; body height: 162.9+/-5.4 cm; and body mass index (BMI) 30.0+/-3.8 kg/m(2). RESULTS: Accelerometer output was significantly correlated with speed during treadmill walking (r=0.95, P<0.01), and short unconstrained walks (r=0.86, P<0.01), although with a large inter-individual variation of the regression parameters. By using individual calibration, it was possible to predict walking speed on a standard urban circuit (predicted vs measured r=0.93, P<0.01, s.e.e.=0.51 km/h). In the free-living experiment, women spent on average 79.9+/-36.0 (range: 31.7-168.2) min/day in displacement activities, from which discontinuous short walking activities represented about 2/3 and continuous ones 1/3. Total walking distance averaged 2.1+/-1.2 (range: 0.4-4.7) km/day. It was performed at an average speed of 5.0+/-0.5 (range: 4.1-6.0) km/h. CONCLUSION: An accelerometer measuring the anteroposterior acceleration of the body can estimate walking speed together with the pattern, intensity and duration of daily walking activity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cerebral perfusion-weighted imaging (PWI) in neonates is known to be technically difficult and there are very few published studies on its use in preterm infants. In this paper, we describe one convenient method to perform PWI in neonates, a method only recently used in newborns. A device was used to manually inject gadolinium contrast material intravenously in an easy, quick and reproducible way. We studied 28 newborn infants, with various gestational ages and weights, including both normal infants and those suffering from different brain pathologies. A signal intensity-time curve was obtained for each infant, allowing us to build perfusion maps. This technique offered a fast and easy method to manually inject a bolus gadolinium contrast material, which is essential in performing PWI in neonates. Cerebral PWI is technically feasible and reproducible in neonates of various gestational age and with various pathologies.