960 resultados para Pinch Valve


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heart valve prostheses are used to replace native heart valves which that are damaged because of congenital diseases or due to ageing. Biological prostheses made of bovine pericardium are similar to native valves and do not require any anticoagulation treatment, but are less durable than mechanical prostheses and usually fail by tearing. Researches are oriented in improving the resistance and durability of biological heart valve prostheses in order to increase their life expectancy. To understand the mechanical behaviour of bovine pericardium and relate it to its microstructure (mainly collagen fibres concentration and orientation) uniaxial tensile tests have been performed on a model material made of collagen fibres. Small Angle Light Scattering (SALS) has been also used to characterize the microstructure without damaging the material. Results with the model material allowed us to obtain the orientation of the fibres, relating the microstructure to mechanical performance

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many of the protein–protein interactions that are essential for eukaryotic intracellular signal transduction are mediated by protein binding modules including SH2, SH3, and LIM domains. Nck is a SH3- and SH2-containing adaptor protein implicated in coordinating various signaling pathways, including those of growth factor receptors and cell adhesion receptors. We report here the identification, cloning, and characterization of a widely expressed, Nck-related adaptor protein termed Nck-2. Nck-2 comprises primarily three N-terminal SH3 domains and one C-terminal SH2 domain. We show that Nck-2 interacts with PINCH, a LIM-only protein implicated in integrin-linked kinase signaling. The PINCH-Nck-2 interaction is mediated by the fourth LIM domain of PINCH and the third SH3 domain of Nck-2. Furthermore, we show that Nck-2 is capable of recognizing several key components of growth factor receptor kinase-signaling pathways including EGF receptors, PDGF receptor-β, and IRS-1. The association of Nck-2 with EGF receptors was regulated by EGF stimulation and involved largely the SH2 domain of Nck-2, although the SH3 domains of Nck-2 also contributed to the complex formation. The association of Nck-2 with PDGF receptor-β was dependent on PDGF activation and was mediated solely by the SH2 domain of Nck-2. Additionally, we have detected a stable association between Nck-2 and IRS-1 that was mediated primarily via the second and third SH3 domain of Nck-2. Thus, Nck-2 associates with PINCH and components of different growth factor receptor-signaling pathways via distinct mechanisms. Finally, we provide evidence indicating that a fraction of the Nck-2 and/or Nck-1 proteins are associated with the cytoskeleton. These results identify a novel Nck-related SH2- and SH3-domain–containing protein and suggest that it may function as an adaptor protein connecting the growth factor receptor-signaling pathways with the integrin-signaling pathways.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contexte: La régurgitation mitrale (RM) est une maladie valvulaire nécessitant une intervention dans les cas les plus grave. Une réparation percutanée de la valve mitrale avec le dispositif MitraClip est un traitement sécuritaire et efficace pour les patients à haut risque chirurgical. Nous voulons évaluer les résultats cliniques et l'impact économique de cette thérapie par rapport à la gestion médicale des patients en insuffisance cardiaque avec insuffisance mitrale symptomatique. Méthodes: L'étude a été composée de deux phases; une étude d'observation de patients souffrant d'insuffisance cardiaque et de régurgitation mitrale traitée avec une thérapie médicale ou le MitraClip, et un modèle économique. Les résultats de l'étude observationnelle ont été utilisés pour estimer les paramètres du modèle de décision, qui a estimé les coûts et les avantages d'une cohorte hypothétique de patients atteints d'insuffisance cardiaque et insuffisance mitrale sévère traitée avec soit un traitement médical standard ou MitraClip. Résultats: La cohorte de patients traités avec le système MitraClip était appariée par score de propension à une population de patients atteints d'insuffisance cardiaque, et leurs résultats ont été comparés. Avec un suivi moyen de 22 mois, la mortalité était de 21% dans la cohorte MitraClip et de 42% dans la cohorte de gestion médicale (p = 0,007). Le modèle de décision a démontré que MitraClip augmente l'espérance de vie de 1,87 à 3,60 années et des années de vie pondérées par la qualité (QALY) de 1,13 à 2,76 ans. Le coût marginal était 52.500 $ dollars canadiens, correspondant à un rapport coût-efficacité différentiel (RCED) de 32,300.00 $ par QALY gagné. Les résultats étaient sensibles à l'avantage de survie. Conclusion: Dans cette cohorte de patients atteints d'insuffisance cardiaque symptomatique et d insuffisance mitrale significative, la thérapie avec le MitraClip est associée à une survie supérieure et est rentable par rapport au traitement médical.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Sutureless aortic valve replacement (AVR) offers an alternative to standard AVR in aortic stenosis. This prospective, single-arm study aimed to demonstrate safety and effectiveness of a bovine pericardial sutureless aortic valve at 1 year. METHODS From February 2010 to September 2013, 658 patients (mean age 78.3 ± 5.6 years; 40.0% octogenarian; 64.4% female; mean Society of Thoracic Surgeons score 7.2 ± 7.4) underwent sutureless AVR in 25 European centers. Concomitant cardiac procedures were performed in 29.5% and minimally invasive cardiac surgery in 33.3%. RESULTS One-year site-reported event rates were 8.1% for all-cause mortality, 4.5% for cardiac mortality, 3.0% for stroke, 1.9% for valve-related reoperation, 1.4% for endocarditis, and 0.6% for major paravalvular leak. No valve thrombosis, migration, or structural valve deterioration occurred. New York Heart Association class improved at least 1 level in 77.5% and remained stable (70.4% New York Heart Association class I or II at 1 year). Mean effective orifice area was 1.5 ± 0.4 cm(2); pressure gradient was 9.2 ± 5.0 mm Hg. Left ventricular mass decreased from 138.5 g/m(2) before surgery to 115.3 g/m(2) at 1 year (P < .001). Echocardiographic core laboratory findings confirmed that paravalvular leak was rare and remained stable during follow-up. CONCLUSIONS The Perceval sutureless valve resulted in low 1-year event rates in intermediate-risk patients undergoing AVR. New York Heart Association class improved in more than three-quarters of patients and remained stable. These data support the safety and efficacy to 1 year of the Perceval sutureless valve in this intermediate-risk population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The tricuspid valve is frequently affected in adults with congenital heart disease (CHD). Disease of this valve can occur primarily or develop secondary to changes in the right ventricle caused by other defects. Quantitative echocardiographic assessment of tricuspid regurgitation is essential to assess its cause and prognosis. Treatment options vary depending on the underlying defect and right ventricular function. Surgical management of tricuspid valve disease is complex and evolving.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare intraoperative cerebral microembolic load between minimally invasive extracorporeal circulation (MiECC) and conventional extracorporeal circulation (CECC) during isolated surgical aortic valve replacement (SAVR), we conducted a randomized trial in patients undergoing primary elective SAVR at a tertiary referral hospital. The primary outcome was the procedural phase-related rate of high-intensity transient signals (HITS) on transcranial Doppler ultrasound. HITS rate was used as a surrogate of cerebral microembolism in pre-defined procedural phases in SAVR using MiECC or CECC with (+F) or without (-F) an oxygenator with integrated arterial filter. Forty-eight patients were randomized in a 1:1 ratio to MiECC or CECC. Due to intraprocedural Doppler signal loss (n = 3), 45 patients were included in final analysis. MiECC perfusion regimen showed a significantly increased HITS rate compared to CECC (by a factor of 1.75; 95% confidence interval, 1.19-2.56). This was due to different HITS rates in procedural phases from aortic cross-clamping until declamping [phase 4] (P = 0.01), and from aortic declamping until stop of extracorporeal perfusion [phase 5] (P = 0.05). Post hoc analysis revealed that MiECC-F generated a higher HITS rate than CECC+F (P = 0.005), CECC-F (P = 0.05) in phase 4, and CECC-F (P = 0.03) in phase 5, respectively. In open-heart surgery, MiECC is not superior to CECC with regard to gaseous cerebral microembolism. When using MiECC for SAVR, the use of oxygenators with integrated arterial line filter appears highly advisable. Only with this precaution, MiECC confers a cerebral microembolic load comparable to CECC during this type of open heart surgery.