968 resultados para Pain measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Eating Disorder Risk Composite (EDRC) comprises the Drive for Thinness, Bulimia, and Body Dissatisfaction subscales of the Eating Disorder Inventory, Third Edition (EDI-3, Garner, 2004). Past research conducted with Latina college women (LCW) has found older versions of the EDRC subscales to be reliable, but the EDI-3's EDRC factor structure has yet to be studied among LCW. The present study investigated the pattern of responses to and the factor structure of the EDRC in LCW. It was hypothesized that eating pathology would be present and that a factor analysiswould find some discrepancies between the original factor structure of the EDRC and the factor structure from LCW. Analyses of data on a 6-point Likert scale indicate that drive for thinness and body dissatisfaction are far more prevalent than is bulimic symptomology in LCW. Principal Axis Factoring with promax rotation was used to extract three factors very similar to the original EDRC. Some discrepancies in the item loadings were observed, most notably that half of the items from the original Body Dissatisfaction subscale did not load together on one factor. Overall, the EDRC appears to be a goodmeasurement of eating- and body-related phenomena among LCW. Implications, limitations, and future directions are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Practical strategies are needed to improve pain awareness among aged care staff and promote a systematic approach to pain identification using evidence-based tools. The purpose of this study was to evaluate a pain identification tool for use by nursing and non-professional staff in residential aged care facilities (RACFs). A controlled pretest-posttest intervention design was conducted in two RACFs in Brisbane, Australia. Completed surveys were returned by 216 staff and 74 residents at baseline and 218 staff and 94 residents at 3-month follow-up. Chart audits were conducted on 308 residents at baseline and 328 at follow-up. Groups were compared on: (1) staff knowledge and attitudes regarding pain, perceived confidence and skills for pain assessment, and perceived quality of pain management, (2) frequency of pain assessments and use of pain interventions, and (3) residents’ perceptions of the quality of pain management. Both groups had high knowledge scores and reported high levels of confidence, skills and perceived quality of pain management at baseline and follow-up. The intervention group showed significant improvement in routine pain assessment and use of non-drug pain interventions. However, due to unexpected changes in control group conditions, both groups increased episodic pain assessment. Overall, staff believed the intervention was clinically useful and fostered a team approach to pain assessment. We found the introduction of pain identification resources with implementation strategies to support frontline staff was partially effective in improving staff and resident outcomes. Nonetheless, our findings confirm the need for change and importance of translational pain research in RACFs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we detail the development of two stakeholder relationships scales. The scales measure major project managers' perceived competence in developing (establishing and maintaining) high quality, effective relationships with stakeholders who are internal and external to their organization. Our sample consists of 373 major project managers from a sub-set of the Australian defense industry. Both the internal stakeholder relationships scale and the external stakeholder relationships scale demonstrated validity and reliability. This research has implications for the interpersonal work relationships literature and the stakeholder management literature. We recommend that researchers test these scales with multiple samples, across different project types and project industries in the future. The stakeholder relationship scales should be versatile enough to be applied to project management generally but are perhaps best suited to major project environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Greenhouse gas (GHG) emissions are simultaneously exhausting the world's supply of fossil fuels and threatening the global climate. In many developing countries, significant improvement in living standards in recent years due to the accelerating development of their economies has resulted in a disproportionate increase in household energy consumption. Therefore, a major reduction in household carbon emissions (HCEs) is essential if global carbon reduction targets are to be met. To do this, major Organisation for Economic Co-operation and Development (OECD) states have already implemented policies to alleviate the negative environmental effects of household behaviors and less carbon-intensive technologies are also proposed to promote energy efficiency and reduce carbon emissions. However, before any further remedial actions can be contemplated, though, it is important to fully understand the actual causes of such large HCEs and help researchers both gain deep insights into the development of the research domain and identify valuable research topics for future study. This paper reviews existing literature focusing on the domain of HCEs. This critical review provides a systematic understanding of current work in the field, describing the factors influencing HCEs under the themes of household income, household size, age, education level, location, gender and rebound effects. The main quantification methodologies of input–output models, life cycle assessment and emission coefficient methods are also presented, and the proposed measures to mitigate HCEs at the policy, technology and consumer levels. Finally, the limitations of work done to date and further research directions are identified for the benefit of future studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Evaluation of scapular posture is an integral component of the clinical assessment of painful neck disorders. The aim of this study was to evaluate agreement between therapist judgements of scapula posture in multiple biomechanical planes in individuals with neck pain. Design Inter-therapist reliability study. Setting Research laboratory. Participants Fifteen participants with chronic neck pain. Main outcome measures Four physiotherapists recorded ratings of scapular orientation (relative to the thorax) in five different scapula postural planes (plane of scapula, sagittal plane, transverse plane, horizontal plane, and vertical plane) under four test conditions (at rest, and during three isometric shoulder conditions) in all participants. Inter-therapist reliability was expressed using both generalized and paired kappa coefficient. Results Following adjustment for expected agreement and the high prevalence of neutral ratings (81%), on average both the generalised kappa (0.37) as well as Cohen's Kappa for the two therapist pairs (0.45 and 0.42) demonstrated only slight to moderate inter-therapist reliability. Conclusions The findings suggest that ratings of scapular posture in individuals with neck pain by visual inspection has only slight to moderate reliability and should only be used in conjunction with other clinical tests when judging scapula function in these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper presents an improved Phase-Locked Loop (PLL) for measuring the fundamental frequency and selective harmonic content of a distorted signal. This information can be used by grid interfaced devices and harmonic compensators. The single-phase structure is based on the Synchronous Reference Frame (SRF) PLL. The proposed PLL needs only a limited number of harmonic stages by incorporating Moving Average Filters (MAF) for eliminating the undesired harmonic content at each stage. The frequency dependency of MAF in effective filtering of undesired harmonics is also dealt with by a proposed method for adaptation to frequency variations of input signal. The method is suitable for high sampling rates and a wide frequency measurement range. Furthermore, an extended model of this structure is proposed which includes the response to both the frequency and phase angle variations. The proposed algorithm is simulated and verified using Hardware-in-the-Loop (HIL) testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement of radon ((222)Rn) activity flux using activated charcoal canisters was examined to investigate the distribution of the adsorbed (222)Rn in the charcoal bed and the relationship between (222)Rn activity flux and exposure time. The activity flux of (222)Rn from five sources of varying strengths was measured for exposure times of one, two, three, five, seven, 10, and 14 days. The distribution of the adsorbed (222)Rn in the charcoal bed was obtained by dividing the bed into six layers and counting each layer separately after the exposure. (222)Rn activity decreased in the layers that were away from the exposed surface. Nevertheless, the results demonstrated that only a small correction might be required in the actual application of charcoal canisters for activity flux measurement, where calibration standards were often prepared by the uniform mixing of radium ((226)Ra) in the matrix. This was because the diffusion of (222)Rn in the charcoal bed and the detection efficiency as a function of the charcoal depth tended to counterbalance each other. The influence of exposure time on the measured (222)Rn activity flux was observed in two situations of the canister exposure layout: (a) canister sealed to an open bed of the material and (b) canister sealed over a jar containing the material. The measured (222)Rn activity flux decreased as the exposure time increased. The change in the former situation was significant with an exponential decrease as the exposure time increased. In the latter case, lesser reduction was noticed in the observed activity flux with respect to exposure time. This reduction might have been related to certain factors, such as absorption site saturation or the back diffusion of (222)Rn gas occurring at the canister-soil interface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Coal mining is of significant economic importance to the Australian economy. Despite this fact, the related workforce is subjected to a number of psychosocial risks and musculoskeletal injury, and various psychological disorders are common among this population group. Because only limited research has been conducted in this population group, we sought to examine the relationship between physical (pain) and psychological (distress) factors, as well as the effects of various demographic, lifestyle, and fatigue indicators on this relationship. METHODS: Coal miners (N = 231) participated in a survey of musculoskeletal pain and distress on-site during their work shifts. Participants also provided demographic information (job type, age, experience in the industry, and body mass index) and responded to questions about exercise and sleep quality (on- and off-shift) as well as physical and mental tiredness after work. RESULTS: A total of 177 workers (80.5%) reported experiencing pain in at least one region of their body. The majority of the sample population (61.9%) was classified as having low-level distress, 28.4% had scores indicating mild to moderate distress, and 9.6% had scores indicating high levels of distress. Both number of pain regions and job type (being an operator) significantly predicted distress. Higher distress score was also associated with greater absenteeism in workers who reported lower back pain. In addition, perceived sleep quality during work periods partially mediated the relationship between pain and distress. CONCLUSION: The study findings support the existence of widespread musculoskeletal pain among the coal-mining workforce, and this pain is associated with increased psychological distress. Operators (truck drivers) and workers reporting poor sleep quality during work periods are most likely to report increased distress, which highlights the importance of supporting the mining workforce for sustained productivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To externally evaluate the accuracy of the new Vancouver Chest Pain Rule and to assess the diagnostic accuracy using either sensitive or highly sensitive troponin assays. Methods Prospectively collected data from 2 emergency departments (EDs) in Australia and New Zealand were analysed. Based on the new Vancouver Chest Pain Rule, low-risk patients were identified using electrocardiogram results, cardiac history, nitrate use, age, pain characteristics and troponin results at 2 hours after presentation. The primary outcome was 30-day diagnosis of acute coronary syndrome (ACS), including acute myocardial infarction, and unstable angina. Sensitivity, specificity, positive predictive values and negative predictive values were calculated to assess the accuracy of the new Vancouver Chest Pain Rule using either sensitive or highly sensitive troponin assay results. Results Of the 1635 patients, 20.4% had an ACS diagnosis at 30 days. Using the highly sensitive troponin assay, 212 (13.0%) patients were eligible for early discharge with 3 patients (1.4%) diagnosed with ACS. Sensitivity was 99.1% (95% CI 97.4-99.7), specificity was 16.1 (95% CI 14.2-18.2), positive predictive values was 23.3 (95% CI 21.1-25.5) and negative predictive values was 98.6 (95% CI 95.9-99.5). The diagnostic accuracy of the rule was similar using the sensitive troponin assay. Conclusions The new Vancouver Chest Pain Rule should be used for the identification of low risk patients presenting to EDs with symptoms of possible ACS, and will reduce the proportion of patients requiring lengthy assessment; however we recommend further outpatient investigation for coronary artery disease in patients identified as low risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose – Ideally, there is no wear in hydrodynamic lubrication regime. A small amount of wear occurs during start and stop of the machines and the amount of wear is so small that it is difficult to measure with accuracy. Various wear measuring techniques have been used where out-of-roundness was found to be the most reliable method of measuring small wear quantities in journal bearings. This technique was further developed to achieve higher accuracy in measuring small wear quantities. The method proved to be reliable as well as inexpensive. The paper aims to discuss these issues. Design/methodology/approach – In an experimental study, the effect of antiwear additives was studied on journal bearings lubricated with oil containing solid contaminants. The test duration was too long and the wear quantities achieved were too small. To minimise the test duration, short tests of about 90 min duration were conducted and wear was measured recording changes in variety of parameters related to weight, geometry and wear debris. The out-of-roundness was found to be the most effective method. This method was further refined by enlarging the out-of-roundness traces on a photocopier. The method was proved to be reliable and inexpensive. Findings – Study revealed that the most commonly used wear measurement techniques such as weight loss, roughness changes and change in particle count were not adequate for measuring small wear quantities in journal bearings. Out-of-roundness method with some refinements was found to be one of the most reliable methods for measuring small wear quantities in journal bearings working in hydrodynamic lubrication regime. By enlarging the out-of-roundness traces and determining the worn area of the bearing cross-section, weight loss in bearings was calculated, which was repeatable and reliable. Research limitations/implications – This research is a basic in nature where a rudimentary solution has been developed for measuring small wear quantities in rotary devices such as journal bearings. The method requires enlarging traces on a photocopier and determining the shape of the worn area on an out-of-roundness trace on a transparency, which is a simple but a crude method. This may require an automated procedure to determine the weight loss from the out-of-roundness traces directly. This method can be very useful in reducing test duration and measuring wear quantities with higher precision in situations where wear quantities are very small. Practical implications – This research provides a reliable method of measuring wear of circular geometry. The Talyrond equipment used for measuring the change in out-of-roundness due to wear of bearings indicates that this equipment has high potential to be used as a wear measuring device also. Measurement of weight loss from the traces is an enhanced capability of this equipment and this research may lead to the development of a modified version of Talyrond type of equipment for wear measurements in circular machine components. Originality/value – Wear measurement in hydrodynamic bearings requires long duration tests to achieve adequate wear quantities. Out-of-roundness is one of the geometrical parameters that changes with progression of wear in a circular shape components. Thus, out-of-roundness is found to be an effective wear measuring parameter that relates to change in geometry. Method of increasing the sensitivity and enlargement of out-of-roundness traces is original work through which area of worn cross-section can be determined and weight loss can be derived for materials of known density with higher precision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IMPORTANCE Patients with chest pain represent a high health care burden, but it may be possible to identify a patient group with a low short-term risk of adverse cardiac events who are suitable for early discharge. OBJECTIVE To compare the effectiveness of a rapid diagnostic pathway with a standard-care diagnostic pathway for the assessment of patients with possible cardiac chest pain in a usual clinical practice setting. DESIGN, SETTING, AND PARTICIPANTS A single-center, randomized parallel-group trial with blinded outcome assessments was conducted in an academic general and tertiary hospital. Participants included adults with acute chest pain consistent with acute coronary syndrome for whom the attending physician planned further observation and troponin testing. Patient recruitment occurred from October 11, 2010, to July 4, 2012, with a 30-day follow-up. INTERVENTIONS An experimental pathway using an accelerated diagnostic protocol (Thrombolysis in Myocardial Infarction score, 0; electrocardiography; and 0- and 2-hour troponin tests) or a standard-care pathway (troponin test on arrival at hospital, prolonged observation, and a second troponin test 6-12 hours after onset of pain) serving as the control. MAIN OUTCOMES AND MEASURES Discharge from the hospital within 6 hours without a major adverse cardiac event occurring within 30 days. RESULTS Fifty-two of 270 patients in the experimental group were successfully discharged within 6 hours compared with 30 of 272 patients in the control group (19.3% vs 11.0%; odds ratio, 1.92; 95% CI, 1.18-3.13; P = .008). It required 20 hours to discharge the same proportion of patients from the control group as achieved in the experimental group within 6 hours. In the experimental group, 35 additional patients (12.9%) were classified as low risk but admitted to an inpatient ward for cardiac investigation. None of the 35 patients received a diagnosis of acute coronary syndrome after inpatient evaluation. CONCLUSIONS AND RELEVANCE Using the accelerated diagnostic protocol in the experimental pathway almost doubled the proportion of patients with chest pain discharged early. Clinicians could discharge approximately 1 of 5 patients with chest pain to outpatient follow-up monitoring in less than 6 hours. This diagnostic strategy could be easily replicated in other centers because no extra resources are required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Animal and human studies have demonstrated that early pain experiences can produce alterations in the nociceptive systems later in life including increased sensitivity to mechanical, thermal, and chemical stimuli. However, less is known about the impact of neonatal immune challenge on future responses to noxious stimuli and the reactivity of neural substrates involved in analgesia. Here we demonstrate that rats exposed to Lipopolysaccharide (LPS; 0.05 mg/kg IP, Salmonella enteritidis) during postnatal day (PND) 3 and 5 displayed enhanced formalin-induced flinching but not licking following formalin injection at PND 22. This LPS-induced hyperalgesia was accompanied by distinct recruitment of supra-spinal regions involved in analgesia as indicated by significantly attenuated Fos-protein induction in the rostral dorsal periaqueductal grey (DPAG) as well as rostral and caudal axes of the ventrolateral PAG (VLPAG). Formalin injections were associated with increased Fos-protein labelling in lateral habenula (LHb) as compared to medial habenula (MHb), however the intensity of this labelling did not differ as a result of neonatal immune challenge. These data highlight the importance of neonatal immune priming in programming inflammatory pain sensitivity later in development and highlight the PAG as a possible mediator of this process

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the results of the time dispersion parameters obtained from a set of channel measurements conducted in various environments that are typical of multiuser Infostation application scenarios are presented. The measurement procedure takes into account the practical scenarios typical of the positions and movements of the users in the particular Infostation network. To provide one with the knowledge of how much data can be downloaded by users over a given time and mobile speed, data transfer analysis for multiband orthogonal frequency division multiplexing (MB-OFDM) is presented. As expected, the rough estimate of simultaneous data transfer in a multiuser Infostation scenario indicates dependency of the percentage of download on the data size, number and speed of the users, and the elapse time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Chest pain is one of the most common complaints in patients presenting to an emergency department. Delays in management due to a lack of readily available objective tests to risk stratify patients with possible acute coronary syndromes can lead to an unnecessarily lengthy admission placing pressure on hospital beds or inappropriate discharge. The need for a co-ordinated system of clinical management based on enhanced communication between departments, timely and appropriate triage, clinical investigation, diagnosis, and treatment was identified. Methods An evidence-based Chest Pain Management Service and clinical pathway were developed and implemented, including the introduction of after-hours exercise stress testing. Results Between November 2005 and March 2013, 5662 patients were managed according to a Chest Pain Management pathway resulting in a reduction of 5181 admission nights by more timely identification of patients at low risk who could then be discharged. In addition, 1360 days were avoided in high-risk patients who received earlier diagnosis and treatment. Conclusions The creation of a Chest Pain Management pathway and the extended exercise stress testing service resulted in earlier discharge for low-risk patients; and timely treatment for patients with positive and equivocal exercise stress test results. This service demonstrated a significant saving in overnight admissions.