893 resultados para Operating Room


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Live bacterial vaccines have great promise both as vaccines against enteric pathogens and as heterologous antigen vectors against diverse diseases. Ideally, room temperature stable dry formulations of live bacterial vaccines will allow oral vaccination without cold-chain storage or injections. Attenuated Salmonella can cross the intestinal wall and deliver replicating antigen plus innate immune activation signals directly to the intestinal immune tissues, however the ingested bacteria must survive firstly gastric acid and secondly the antimicrobial defences of the small intestine. We found that the way in which cells are grown prior to formulation markedly affects sensitivity to acid and bile. Using a previously published stable storage formulation that maintained over 10% viability after 56 days storage at room temperature, we found dried samples of an attenuated S. typhimurium vaccine lost acid and bile resistance compared to the same bacteria taken from fresh culture. The stable formulation utilised osmotic preconditioning in defined medium plus elevated salt concentration to induce intracellular trehalose accumulation before drying. Dried bacteria grown in rich media without osmotic preconditioning showed more resistance to bile, but less stability during storage, suggesting a trade-off between bile resistance and stability. Further optimization is needed to produce the ultimate room-temperature stable oral live bacterial vaccine formulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multiple regression analysis is a statistical technique which allows to predict a dependent variable from m ore than one independent variable and also to determine influential independent variables. Using experimental data, in this study the multiple regression analysis is applied to predict the room mean velocity and determine the most influencing parameters on the velocity. More than 120 experiments for four different heat source locations were carried out in a test chamber with a high level wall mounted air supply terminal at air change rates 3-6 ach. The influence of the environmental parameters such as supply air momentum, room heat load, Archimedes number and local temperature ratio, were examined by two methods: a simple regression analysis incorporated into scatter matrix plots and multiple stepwise regression analysis. It is concluded that, when a heat source is located along the jet centre line, the supply momentum mainly influences the room mean velocity regardless of the plume strength. However, when the heat source is located outside the jet region, the local temperature ratio (the inverse of the local heat removal effectiveness) is a major influencing parameter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Building services are worth about 2% GDP and are essential for the effective and efficient operations of the building. It is increasingly recognised that the value of a building is related to the way it supports the client organisation’s ongoing business operations. Building services are central to the functional performance of buildings and provide the necessary conditions for health, well-being, safety and security of the occupants. They frequently comprise several technologically distinct sub-systems and their design and construction requires the involvement of numerous disciplines and trades. Designers and contractors working on the same project are frequently employed by different companies. Materials and equipment is supplied by a diverse range of manufacturers. Facilities managers are responsible for operation of the building service in use. The coordination between these participants is crucially important to achieve optimum performance, but too often is neglected. This leaves room for serious faults. The need for effective integration is important. Modern technology offers increasing opportunities for integrated personal-control systems for lighting, ventilation and security as well as interoperability between systems. Opportunities for a new mode of systems integration are provided by the emergence of PFI/PPP procurements frameworks. This paper attempts to establish how systems integration can be achieved in the process of designing, constructing and operating building services. The essence of the paper therefore is to envisage the emergent organisational responses to the realisation of building services as an interactive systems network.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In designing modern office buildings, building spaces are frequently zoned by introducing internal partitioning, which may have a significant influence on the room air environment. This internal partitioning was studied by means of model test, numerical simulation, and statistical analysis as the final stage. In this paper, the results produced from the statistical analysis are summarized and presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The experiment asks whether constancy in hearing precedes or follows grouping. Listeners heard speech-like sounds comprising 8 auditory-filter shaped noise-bands that had temporal envelopes corresponding to those arising in these filters when a speech message is played. The „context‟ words in the message were “next you‟ll get _to click on”, into which a “sir” or “stir” test word was inserted. These test words were from an 11-step continuum that was formed by amplitude modulation. Listeners identified the test words appropriately and quite consistently, even though they had the „robotic‟ quality typical of this type of 8-band speech. The speech-like effects of these sounds appears to be a consequence of auditory grouping. Constancy was assessed by comparing the influence of room reflections on the test word across conditions where the context had either the same level of reflections, or where it had a much lower level. Constancy effects were obtained with these 8-band sounds, but only in „matched‟ conditions, where the room reflections were in the same bands in both the context and the test word. This was not the case in a comparison „mismatched‟ condition, and here, no constancy effects were found. It would appear that this type of constancy in hearing precedes the across-channel grouping whose effects are so apparent in these sounds. This result is discussed in terms of the ubiquity of grouping across different levels of representation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Listeners can attend to one of several simultaneous messages by tracking one speaker’s voice characteristics. Using differences in the location of sounds in a room, we ask how well cues arising from spatial position compete with these characteristics. Listeners decided which of two simultaneous target words belonged in an attended “context” phrase when it was played simultaneously with a different “distracter” context. Talker difference was in competition with position difference, so the response indicates which cue‐type the listener was tracking. Spatial position was found to override talker difference in dichotic conditions when the talkers are similar (male). The salience of cues associated with differences in sounds, bearings decreased with distance between listener and sources. These cues are more effective binaurally. However, there appear to be other cues that increase in salience with distance between sounds. This increase is more prominent in diotic conditions, indicating that these cues are largely monaural. Distances between spectra calculated using a gammatone filterbank (with ERB‐spaced CFs) of the room’s impulse responses at different locations were computed, and comparison with listeners’ responses suggested some slight monaural loudness cues, but also monaural “timbre” cues arising from the temporal‐ and spectral‐envelope differences in the speech from different locations.