973 resultados para Minimally invasive surgery
Resumo:
Infection of an intervertebral disk is a serious condition. Diagnosis often is elusive and difficult. It is imperative to obtain appropriate microbiological specimens before initiation of treatment. The authors describe a 51-year-old woman with lumbar spondylodiscitis that was because of infection after the placement of an epidural catheter for postoperative analgesia. A spinal magnetic resonance imaging confirmed the diagnosis, but computed tomography-guided fine needle biopsy did not provide adequate material for a microbiologic diagnosis. Laparoscopic biopsies of the involved disk provided good specimens and a diagnosis of Propionibacterium acnes infection. The authors believe that this minimally invasive procedure should be performed when computed tomography-guided fine needle biopsy does not provide a microbiologic diagnosis in spondylodiscitis.
Resumo:
INTRODUCTION: Extensor mechanism ruptures might be easily overlooked and misdiagnosed, and delayed diagnosis of quadriceps tendon rupture is frequent. However, the literature recommends early surgical repair within 72 h. PATIENTS AND METHODS: This paper describes a new simple clinical diagnostic test that directly evaluates the integrity of the distal 5 cm of the quadriceps tendon itself. It consists of inserting a needle in the tendon, proximal to the suspected rupture and mobilising the knee joint. RESULTS: The suspected ruptured quadriceps tendons with a positive 'needle' diagnostic test were confirmed intra-operatively. CONCLUSIONS: This minimally invasive and easily available technique should be considered in the diagnostic work-up and treatment planning of patients with suspected tears of the quadriceps tendon.
Resumo:
Buccal swabs have recently been used as a minimally invasive sampling method in genetic studies of wild populations, including amphibian species. Yet it is not known to date what is the level of reliability for microsatellite genotypes obtained using such samples. Allelic dropout and false alleles may affect the genotyping derived from buccal samples. Here we quantified the success of microsatellite amplification and the rates of genotyping errors using buccal swabs in two amphibian species, the Alpine newt Triturus alpestris and the Green tree frog Hyla arborea, and we estimated two important parameters for downstream analyses, namely the number of repetitions required to achieve typing reliability and the probability of identity among genotypes. Amplification success was high, and only one locus tested required two to three repetitions to achieve reliable genotypes, showing that buccal swabbing is a very efficient approach allowing good quality DNA retrieval. This sampling method which allows avoiding the controversial toe-clipping will likely prove very useful in the context of amphibian conservation.
Resumo:
New approaches to the clinical treatment of traumatic nerve injuries may one day utilize stem cells to enhance nerve regeneration. Adipose-derived stem cells (ASC) are found in abundant quantities and can be harvested by minimally invasive procedures that should facilitate their use in such regenerative applications. We have analyzed the properties of human ASC isolated from the deep and superficial layers of abdominal fat tissue obtained during abdominoplasty procedures. Cells from the superficial layer proliferate significantly faster than those from the deep layer. In both the deep and superficial layers, ASC express the pluripotent stem cell markers oct4 and nanog and also the stro-1 cell surface antigen. Superficial layer ASC induce the significantly enhanced outgrowth of neurite-like processes from neuronal cell lines when compared with that of deep layer cells. However, analysis by reverse transcription with the polymerase chain reaction and by enzyme-linked immunosorbent assay has revealed that ASC isolated from both layers express similar levels of the following neurotrophic factors: nerve growth factor, brain-derived neurotrophic factor and glial-derived neurotrophic factor. Thus, human ASC show promising potential for the treatment of traumatic nerve injuries. In particular, superficial layer ASC warrant further analysis of their neurotrophic molecules.
Resumo:
Colorectal cancer (CRC) is the second leading cause of cancer-related death in developed countries. Early detection of CRC leads to decreased CRC mortality. A blood-based CRC screening test is highly desirable due to limited invasiveness and high acceptance rate among patients compared to currently used fecal occult blood testing and colonoscopy. Here we describe the discovery and validation of a 29-gene panel in peripheral blood mononuclear cells (PBMC) for the detection of CRC and adenomatous polyps (AP). Blood samples were prospectively collected from a multicenter, case-control clinical study. First, we profiled 93 samples with 667 candidate and 3 reference genes by high throughput real-time PCR (OpenArray system). After analysis, 160 genes were retained and tested again on 51 additional samples. Low expressed and unstable genes were discarded resulting in a final dataset of 144 samples profiled with 140 genes. To define which genes, alone or in combinations had the highest potential to discriminate AP and/or CRC from controls, data were analyzed by a combination of univariate and multivariate methods. A list of 29 potentially discriminant genes was compiled and evaluated for its predictive accuracy by penalized logistic regression and bootstrap. This method discriminated AP >1cm and CRC from controls with a sensitivity of 59% and 75%, respectively, with 91% specificity. The behavior of the 29-gene panel was validated with a LightCycler 480 real-time PCR platform, commonly adopted by clinical laboratories. In this work we identified a 29-gene panel expressed in PBMC that can be used for developing a novel minimally-invasive test for accurate detection of AP and CRC using a standard real-time PCR platform.
Resumo:
Geophysical data may provide crucial information about hydrological properties, states, and processes that are difficult to obtain by other means. Large data sets can be acquired over widely different scales in a minimally invasive manner and at comparatively low costs, but their effective use in hydrology makes it necessary to understand the fidelity of geophysical models, the assumptions made in their construction, and the links between geophysical and hydrological properties. Geophysics has been applied for groundwater prospecting for almost a century, but it is only in the last 20 years that it is regularly used together with classical hydrological data to build predictive hydrological models. A largely unexplored venue for future work is to use geophysical data to falsify or rank competing conceptual hydrological models. A promising cornerstone for such a model selection strategy is the Bayes factor, but it can only be calculated reliably when considering the main sources of uncertainty throughout the hydrogeophysical parameter estimation process. Most classical geophysical imaging tools tend to favor models with smoothly varying property fields that are at odds with most conceptual hydrological models of interest. It is thus necessary to account for this bias or use alternative approaches in which proposed conceptual models are honored at all steps in the model building process.
Resumo:
Patients with chronic heart failure who are not eligible for heart transplant and whose life expectancy depends mainly on the heart disease may benefit from mechanical circulatory support. Mechanical circulatory support restores adequate cardiac output and organ perfusion and eventually improves patients' clinical condition, quality of life and life expectancy. This treatment is called destination therapy (DT) and we estimate that in Switzerland more than 120 patients per year could benefit from it. In the last 10 years, design of the devices, implantation techniques and prognoses have changed dramatically. The key to successful therapy with a left ventricular assist device is appropriate patient selection, although we are still working on the definition of reliable inclusion and exclusion criteria and optimal timing for surgical implantation. Devices providing best long-term results are continuous flow, rotary or axial blood pumps implanted using minimally invasive techniques on a beating heart. These new devices (Thoratec HeartMate II and HeartWare HVAD) have only a single moving part, and have improved durability with virtually 10 years freedom from mechanical failure. In selected patients, the overall actuarial survival of DT patients is 75% at 1 year and 62% at 2 years, with a clear improvement in quality of life compared with medical management only. Complications include bleeding and infections; their overall incidence is significantly lower than with previous devices and their management is well defined. DT is evolving into an effective and reasonably cost-effective treatment option for a growing population of patients not eligible for heart transplant, showing encouraging survival rates at 2 years and providing clear improvement in quality of life. The future is bright for people suffering from chronic heart failure.
Resumo:
Abstract Gastrointestinal bleeding represents a common medical emergency, with considerable morbidity and mortality rates, and a prompt diagnosis is essential for a better prognosis. In such a context, endoscopy is the main diagnostic tool; however, in cases where the gastrointestinal hemorrhage is massive, the exact bleeding site might go undetected. In addition, a trained professional is not always present to perform the procedure. In an emergency setting, optical colonoscopy presents limitations connected with the absence of bowel preparation, so most of the small bowel cannot be assessed. Scintigraphy cannot accurately demonstrate the anatomic location of the bleeding and is not available at emergency settings. The use of capsule endoscopy is inappropriate in the acute setting, particularly in the emergency department at night, and is a highly expensive method. Digital angiography, despite its high sensitivity, is invasive, presents catheterization-related risks, in addition to its low availability at emergency settings. On the other hand, computed tomography angiography is fast, widely available and minimally invasive, emerging as a promising method in the diagnostic algorithm of these patients, being capable of determining the location and cause of bleeding with high accuracy. Based on a critical literature review and on their own experience, the authors propose a computed tomography angiography protocol to assess the patient with gastrointestinal bleeding.
Resumo:
Laparoscopic techniques have provided a new dimension to correct functional disorders of the esophagus, which has stimulated some investigators to recently report the use of laparoscopic cardiomyotomy in the treatment of esophageal achalasia. Now, a new instrument has been added to the current laparoscopic technique to offer a safer and easier method to proceed complete myotomy. After the dissection of the esophagogastric junction, a special catheter is introduced reaching the stomach. lt has an illuminated 10 cm extremity connected to a light source. lts withdrawal allows to visualize every muscle circular fiber by transillumination withan improved view provide by the laparoscopic optic system lens. This condition modifies the operative surgeon s attitude offering a better controlled situation over the procedure. The use of transillumination o fthe esophagogastric junction provides a good identification of the mucosa e submucosa avoiding the risk of esophageal perforation. It also helps to perform a complete myotomy preventing the ocurrence of persistent disphagia in the postoperative period. Cardiomyotomy with parcial fundoplication is possible by videolaparoscopic approach, now made easier with transillumination. This technique is safe and the functional results are similar to those observed in the literature for conventional open procedures, with the obvious advantages of the minimally invasive approach.
Resumo:
The pectus excavatum treatment has two different approaches: non-surgical techniques (modified dynamic thoracic compressor, exercises and the vacuum bell) or surgical techniques (silastic or solid silicone implant, open surgical repair like sternochondroplasty and minimally invasive repair). The introduction of Nuss procedure improved the pectus excavatum treatment, but its low acceptance was due to the high complication rate (e.g. cardiac perfuration). The thoracoscopy use for bar mediastinal passage reduced the complication rate. In comparison with sternochondroplasty, the Nuss procedure has smaller incision, less blood loss and less operative time. However, it has more reoperations, complications, longer hospital stay and more readmission rates, more time of thoracic epidural catheter for postoperative analgesia and more need for analgesic after being discharged. Although Nuss procedure has been used in children, patients under ten years must be only observed. The Nuss procedure is applicable to moderate or light symmetrical pectus excavatum, without costal protrusion, in young and adolescents patients. Furthermore, the sternochondroplasty is applicable to severe or asymmetric pectus excavatum, with or without inferior costal protrusion. Therefore, Nuss procedure and sternocondroplasty are not antagonistic procedures, and they must be used in accordance with a treatment organogram and the technique choice must be by functional and aesthetic outcome.
Resumo:
We present a case of a 54-year-old man with abdominal pain four hours after colonoscopy and upper endoscopy. Since he had had a polipectomy and an ulcer was seen in the terminal ileum, the diagnosis of appendicitis was even more difficult. The authors discuss the rarity of this situation and the minimally invasive approach to treat appendicitis.
Resumo:
The ocelot (Leopardus pardalis) is included in list of wild felid species protected by CITES and is part of conservation strategies that necessarily involve the use of assisted reproduction techniques, which requires practical and minimally invasive techniques of high reproducibility that permit the study of animal reproductive physiology. The objective of this study was to compare and validate two commercial assays: ImmuChem Double Antibody Corticosterone 125I RIA from ICN Biomedicals, Costa Mesa, CA, USA; and Coat-a-Count Cortisol 125I RIA from DPC, Los Angeles, CA, USA, for assessment of fecal glucocorticoid metabolites in ocelots submitted to ACTH (adrenocorticotropic hormone) challenge. Fecal samples were collected from five ocelots kept at the Brazilian Center of Neotropical Felines, Associação Mata Ciliar, São Paulo, Brazil, and one of the animals was chosen as a negative control. The experiment was conducted over a period of 9 days. On day 0, a total dose of 100 IU ACTH was administered intramuscularly. Immediately after collection the samples were stored at 20C in labeled plastic bags. The hormone metabolites were subsequently extracted and assayed using the two commercial kits. Previously it was performed a trial with the DPC kit to check the best extraction method for hormones metabolites. Data were analyzed with the SAS program for Windows V8 and reported as means ± SEM. The Schwarzenberger extraction method was slightly better when compared with the Wasser extraction method (103,334.56 ± 19,010.37ng/g of wet feces and 59,223.61 ± 12,725.36ng/g of wet feces respectively; P=0,0657). The ICN kit detected an increase in glucocorticoid metabolite concentrations in a more reliable manner. Metabolite concentrations (ng/g wet feces) on day 0 and day 1 were 66,956.28 ± 36,786.93 and 92,991.19 ± 28,555.63 for the DPC kit, and 205,483.32 ± 83,811.32 and 814,578.75 ± 292,150.47 for the ICN kit, respectively. The limit of detection for the ICN kit was 7.7 ng/mL for 100% B/Bo (25ng/mL for 88%B/Bo) and for the DPC kit it was 0.2ug/dL for 90.95% B/Bo (1ug/dL for 81.27% B/Bo). In conclusion it was confirmed that the Schwarzenberger extraction method and the ICN kit are superior for extracting and measuring fecal glucocorticoid metabolites in ocelot fecal samples.
Resumo:
In the last few years, the use of laparoscopy in veterinary medicine has expanded and consequently so was the need for studies that establish the advantages, disadvantages and possible complications of each procedure. The purpose of the current study was to describe a laparoscopic splenectomy technique and the alterations due to this access, and compare it to the open procedure in dogs. A total of 15 healthy female mongrel dogs were used, with mean weight of 17.4±2.5kg. The animals were distributed into three groups: Group IA of open splenectomy (laparotomy) using double ligation of the vessels of the splenic hilum with poliglicolic acid, Group IB of open splenectomy (laparotomy) with bipolar electrocoagulation of the splenic hilum, and Group II of laparoscopic access with bipolar electrocoagulation of the splenic hilum. Operative time, blood loss, size of incisions, complications during and after surgery were evaluated. Other parameters included pain scores, white blood cell (WBC) counts and postoperative serum concentrations of alanine aminotransferase (ALT), alkaline phosphatase (ALP), creatine kinase (CK), C-reactive protein (CRP), glucose and cortisol. No differences were found in the evaluation of parameters between both open splenectomy techniques employed. Laparoscopic access presented significant differences (p<0,05) when compared with open surgery: Longer operative time, smaller abdominal access, decrease in blood loss, lower concentrations of CRP, higher levels of CK and ALP, and lower scores in the pain scale. Laparoscopic surgery showed fewer complications of the surgical wound. No significant differences were observed between groups in the postoperative temperature, WBC, ALT, cortisol and glucose concentrations. In conclusion, the laparoscopic technique is useful for splenectomy in dogs, being advantageous in terms of blood loss, surgical stress and surgical wounds. However, it expends more operative time and causes transitory increase in hepatic and muscular enzymes.
Resumo:
Abstract: The concentration of heavy metals (Cr, Fe, Al, As, Cd, Cu, Pb, Mo, Ni, Se and Zn) was evaluated in the blood of nestling blue macaws (Anodorhynchus hyacinthinus) captured in the Pantanal, Mato Grosso do Sul (n=26) in 2012; this was based on the hypothesis that these birds exhibit levels of these heavy metals in their organism and that these interfere in hatching success, weight and age of the chicks. Blood samples were digested with nitric acid and hydrochloric acid and the quantification of metals was performed by ICP-OES (Optical Emission Spectroscopy and Inductively Coupled Plasma). Blood samples of nestlings showed concentrations of Cr (0.10μg/g) Fe (3.06μg/g) Al (3.46μg/g), Cd (0.25μg/g) Cu (0.74μg/g), Mo (0.33μg/g), Ni (0.61μg/g), Se (0.98μg/g), and Zn (2.08μg/g). The levels of heavy metals found were not associated with weight, age and hatching success of the chicks.
Resumo:
Measuring protein biomarkers from sample matrix, such as plasma, is one of the basic tasks in clinical diagnostics. Bioanalytical assays used for the measuring should be able to measure proteins with high sensitivity and specificity. Furthermore, multiplexing capability would also be advantageous. To ensure the utility of the diagnostic test in point-of-care setting, additional requirements such as short turn-around times, ease-ofuse and low costs need to be met. On the other hand, enhancement of assay sensitivity could enable exploiting novel biomarkers, which are present in very low concentrations and which the current immunoassays are unable to measure. Furthermore, highly sensitive assays could enable the use of minimally invasive sampling. In the development of high-sensitivity assays the label technology and affinity binders are in pivotal role. Additionally, innovative assay designs contribute to the obtained sensitivity and other characteristics of the assay as well as its applicability. The aim of this thesis was to study the impact of assay components on the performance of both homogeneous and heterogeneous assays. Applicability of two different lanthanide-based label technologies, upconverting nanoparticles and switchable lanthanide luminescence, to protein detection was explored. Moreover, the potential of recombinant antibodies and aptamers as alternative affinity binders were evaluated. Additionally, alternative conjugation chemistries for production of the labeled binders were studied. Different assay concepts were also evaluated with respect to their applicability to point-of-care testing, which requires simple yet sensitive methods. The applicability of upconverting nanoparticles to the simultaneous quantitative measurement of multiple analytes using imaging-based detection was demonstrated. Additionally, the required instrumentation was relatively simple and inexpensive compared to other luminescent lanthanide-based labels requiring time-resolved measurement. The developed homogeneous assays exploiting switchable lanthanide luminescence were rapid and simple to perform and thus applicable even to point-ofcare testing. The sensitivities of the homogeneous assays were in the picomolar range, which are still inadequate for some analytes, such as cardiac troponins, requiring ultralow limits of detection. For most analytes, however, the obtained limits of detection were sufficient. The use of recombinant antibody fragments and aptamers as binders allowed site-specific and controlled covalent conjugation to construct labeled binders reproducibly either by using chemical modification or recombinant technology. Luminescent lanthanide labels were shown to be widely applicable for protein detection in various assay setups and to contribute assay sensitivity.