878 resultados para Mean deviation
Resumo:
Examination of 40 time series of multidisciplinary environmental variables from the Pacific Ocean and the Americas, collected in 1968 to 1984, demonstrated the remarkable consistency of a major climate-related, step-like change in 1976. To combine the 40 variables (e.g., air and water temperatures, Southern Oscillation, chlorophyll, geese, salmon, crabs, glaciers, atmospheric dust, coral, carbon dioxide, winds, ice cover, Bering Strait transport) into a single time series, standard variants of individual annual values (subtracting the mean and dividing by a standard deviation) were averaged. Analysis of the resulting time series showed that the single step in 1976, separating the 1968-1975 period from the 1977-1984 period, accounted for 89% of variance within the composite time series. Apparently, one of the Earth's large ecosystems occasionally undergoes large abrupt shifts.
Resumo:
A correção de deformidades esqueléticas da face por meio de um tratamento ortodôntico-cirúrgico tornou-se uma opção segura e previsível. Os movimentos ósseos são milimetricamente calculados e executados cirurgicamente, assim como a oclusão é meticulosamente engrenada através dos movimentos ortodônticos. Os efeitos que os tecidos moles sofrem com as cirurgias ortognáticas são, no entanto, menos previsíveis, e apesar do principal objetivo da cirurgia ortognática ser uma melhora funcional, o componente estético é sem dúvida de extrema importância. Em especial, a região de base alar apresenta resultados muito variáveis, a despeito dos bons resultados esqueléticos atingidos. O objetivo deste estudo foi comparar 2 diferentes tipos de sutura utilizados na região de base do nariz, e observar qual tipo apresenta um resultado que melhor acompanhe os movimentos realizados pelo tecido esquelético. Trinta e cinco pacientes foram aleatoriamente distribuídos em 2 grupos. O grupo 1 funcionou como controle e os pacientes receberam a plicatura nasal intra-oral, que é o tipo de plicatura nasal mais descrito na literatura. Já os pacientes do grupo 2 receberam plicatura nasal extra-oral. Para análise estatística foram calculadas as médias e desvios padrões dos grupos, e a hipótese nula de que não havia diferença entre os 2 grupos foi testata com o teste T de Student. Em ambos os grupos ocorreu um alargamento da base do nariz, porém a média de alargamento do grupo 1 foi de 2,50 milímetros (mm), enquanto que a média de alargamento do grupo 2 foi de 1,26 mm. Além disso, o desvio padrão foi menor para o grupo 2, e a hipótese nula foi rejeitada (p<0,05), demonstrando que a diferença entre os grupos foi estatisticamente significativa. Pôde-se concluir que quando objetiva-se um controle mais previsível e rigoroso da base do nariz, a plicatura nasal extra-oral cumprirá melhor esta função.
Resumo:
We develop a method for performing one-loop calculations in finite systems that is based on using the WKB approximation for the high energy states. This approximation allows us to absorb all the counterterms analytically and thereby avoids the need for extreme numerical precision that was required by previous methods. In addition, the local approximation makes this method well suited for self-consistent calculations. We then discuss the application of relativistic mean field methods to the atomic nucleus. Self-consistent, one loop calculations in the Walecka model are performed and the role of the vacuum in this model is analyzed. This model predicts that vacuum polarization effects are responsible for up to five percent of the local nucleon density. Within this framework the possible role of strangeness degrees of freedom is studied. We find that strangeness polarization can increase the kaon-nucleus scattering cross section by ten percent. By introducing a cutoff into the model, the dependence of the model on short-distance physics, where its validity is doubtful, is calculated. The model is very sensitive to cutoffs around one GeV.
Resumo:
Mean velocity profiles were measured in the 5” x 60” wind channel of the turbulence laboratory at the GALCIT, by the use of a hot-wire anemometer. The repeatability of results was established, and the accuracy of the instrumentation estimated. Scatter of experimental results is a little, if any, beyond this limit, although some effects might be expected to arise from variations in atmospheric humidity, no account of this factor having been taken in the present work. Also, slight unsteadiness in flow conditions will be responsible for some scatter.
Irregularities of a hot-wire in close proximity to a solid boundary at low speeds were observed, as have already been found by others.
That Kármán’s logarithmic law holds reasonably well over the main part of a fully developed turbulent flow was checked, the equation u/ut = 6.0 + 6.25 log10 yut/v being obtained, and, as has been previously the case, the experimental points do not quite form one straight line in the region where viscosity effects are small. The values of the constants for this law for the best over-all agreement were determined and compared with those obtained by others.
The range of Reynolds numbers used (based on half-width of channel) was from 20,000 to 60,000.
Resumo:
O uso de primers autocondicionantes e de bráquetes com compósito pré-incorporado tem sido apresentado como uma alternativa para a redução de passos clínicos. O propósito deste estudo foi avaliar o efeito de um primer autocondicionante (Transbond Plus Self-Etching Primer - SEP) na resistência ao cisalhamento de bráquetes com compósito pré-incorporado colados in vivo. A amostra consistiu de 92 dentes obtidos de 23 pacientes com indicação prévia de extração de 4 pré-molares. Os dentes foram divididos em 4 grupos, sendo os bráquetes colados pelo mesmo operador, alternando os quadrantes em cada paciente: Grupo 1 (controle) - Ácido fosfórico à 37% + primer (Transbond XT Primer) + compósito (Transbond XT Adhesive Paste) + bráquete convencional; Grupo 2 - Ácido fosfórico à 37% + primer + bráquete com compósito pré-incorporado; Grupo 3 SEP + compósito + bráquete convencional; Grupo 4 - SEP + bráquete com compósito pré-incorporado. Após 30 dias os pré-molares foram extraídos, sendo submetidos ao teste de resistência ao cisalhamento através da uma Máquina de Ensaios Universal, com velocidade de 0,5mm/min. Os dados obtidos pelos grupos foram analisados com 2-way ANOVA (p<0,05). As forças médias e desvios padrão obtidos foram os seguintes: Grupo 1 = 11,35 (2,36) MPa; Grupo 2 = 9,77 (2,49) MPa; Grupo 3 = 10,89 (2,60) MPa; e Grupo 4 = 10,16 (2,75) MPa. Não foi observada diferença significativa entre o uso do SEP e o de condicionador e primer tradicionais (p = 0,948). De qualquer modo, diferenças significativas na força de adesão foram observadas quando utilizados bráquetes com compósito pré-incorporado (p = 0,032). Pode ser concluído que a combinação do primer autocondicionante com o bráquete com compósito pré-incorporado apresentou valores de força de adesão adequados, sendo promissora para uso clínico.
Resumo:
A locally integrable function is said to be of vanishing mean oscillation (VMO) if its mean oscillation over cubes in Rd converges to zero with the volume of the cubes. We establish necessary and sufficient conditions for a locally integrable function defined on a bounded measurable set of positive measure to be the restriction to that set of a VMO function.
We consider the similar extension problem pertaining to BMO(ρ) functions; that is, those VMO functions whose mean oscillation over any cube is O(ρ(l(Q))) where l(Q) is the length of Q and ρ is a positive, non-decreasing function with ρ(0+) = 0.
We apply these results to obtain sufficient conditions for a Blaschke sequence to be the zeros of an analytic BMO(ρ) function on the unit disc.
Resumo:
The Amazon river, located in northernBrazil, discharges between 80,000 and 250,000 m3s-1 of water onto the adjacent shelf, creating a plume of brackish water that extends hundreds of kilometers away from the river mouth. This river also carries a large amount of fine sediments to the ocean where fluid mud has been found in the topset and upper foreset layers of the subaqueous delta formed on the mid-shelf. One of the main goals of this dissertation is to describe how turbulence and suspended sediment concentration vary along the Northern Channel of the Amazon river. Water column measurements were carried out in October 2008 at six anchor stations (P1, P3, P5, P6, P8 e P9) located seaward of the river mouth; P1 and P9 were 125 km apart. Each station was occupied during 13 hours during which current speed and direction were continuously sampled with a 600 kHz Teledyne-RDI ADCP; hourly profiles of temperature, salinity, turbidity and depth were also obtained. Water samples were collected for determination of Suspended Particulate Matter (SPM) concentration and calibration of the turbidity sensor. Current speed reached values above 1.5 m s1 in the along-channel direction (NE-SW); a remarkable ebb-flood asymmetry was observed and flows were strongly ebb-dominated. Throughout the water column, SPM concentration at stations P1 and P3 varied between 100 and 300 mg L1 in association with the presence of freshwater. In contrast, a strong salinity gradient was observed between stations P6 and P9, coinciding with the occurrence of concentrations of SPM above 10 g L-1 (fluid mud). At stations P3, P5 and P6, interface between freshwater from the Amazon river and salt water from the continental shelf, shear stresses wereestimated through four diferents methods: Reynolds, Turbulent Kinetic Energy (TKE), modified TKE and Quadratic Law; in the nearbed region (3 mab) the computed values varied between 0 and 3 Pa. At the three stations (P3, P5 and P6) the lowest and the highest shear stress values were obtained through, respectively, the Reynolds and the TKE methods. Over the whole water column turbulence intensity was estimated through the standard deviation of the turbulent component of the along-channel current velocity (root-mean square of u); from these values, it was estimated the turbulent dissipation of energy (G), whose values at 3 mab varied between zero and 20 s1.
Resumo:
The surface temperature of Windermere has been recorded by the staff of the Freshwater Biological Association on every weekday (with a few minor exceptions) since 11 January 1933. This publication presents this information in a form which can easily be used by individual research workers. There are 43 tables (1 for each year, 1933-1975) which give the data, expressed as degree-days centigrade. The tables show for each month the number of degree-days above each temperature from 0 degree C to the highest recorded, at 1 degree C intervals. Mean temperatures are obtained by dividing the number of degree-days over 0 degree C by the relevant number of days. The advantage of degree-days rather than mean temperatures is that degree-days are additive so data for any desired periods may be combined quickly and simply. Seasonal results for spring, summer, autumn and winter are presented in tabular form, as are selected totals for comparisons between years. Further tables give the mean temperature in each month of the year, and the frequency distributions of monthly mean temperatures.
Resumo:
提出了一种基于基频分量消光的波片快轴标定方法,并利用琼斯矩阵对其标定原理进行了分析。激光器、起偏器、相位调制器、待标定1/4波片、检偏器和光电探测器构成标定光路,起偏器、检偏器的透光轴与相位调制器的振动轴分别成+45°和0°夹角。准直激光束依次经过起偏器、相位调制器、待标定1/4波片和检偏器,由光电探测器接收。理论分析表明该标定方法标定精度主要取决于检偏器的定位误差。实验验证了该标定方法的有效性,1/4波片快轴标定结果的最大偏差为0.043°,标准差为0.012°,标定精度为0.05°。
Resumo:
Trata-se de um estudo descritivo, retrospectivo, com abordagem quantitativa cujo objetivo geral foi descrever e analisar o perfil epidemiológico dos pacientes com Insuficiência Cardíaca atendidos pela Clinica de IC de um Hospital Universitário. Os objetivos específicos orientam-se para:(a)Caracterizar os casos de Insuficiência Cardíaca segundo variáveis demográficas, variáveis clínicas, de diagnóstico e co morbidades;(b)Comparar as características clínicas e demográficas dos pacientes conforme grupos etiológicos identificados e fração de ejeção;(c)Determinar a taxa de mortalidade e hospitalização dos pacientes acompanhados pela clínica. Os dados analisados neste estudo são oriundos de um banco de dados onde são alocadas informações dos pacientes em atendimento ambulatorial da referida clinica.Para a análise dos dados foi utilizada a estatística descritiva, freqüências e porcentagens assim como tabelas e gráficos para a demonstração dos dados levantados.Os mesmos foram analisados através do software SPSS v.18.0, no qual se utilizou a estatística multivariada e curvas de sobrevida de Kaplan-Meyer.Os resultados apontam para uma predominância masculina de 60,1%, com idade de 63,5 anos. Na caracterização quanto à classe funcional observa-se que a predominante é a classe funcional I e II com 73,6% do total. Os pacientes assistidos apresentam uma média de 42% da fração de ejeção do ventrículo esquerdo e 61,7% possuem etiologia não isquêmica. Em nosso estudo, descrevemos 71,8% de portadores de disfunção sistólica. Os pacientes com etiologia isquêmica tinham predomínio do sexo masculino(70,7%), e a etiologia não isquêmica com uma prevalência maior do sexo feminino(45,5%vs 29,3%;p<0,001). Além disso, os pacientes isquêmicos eram mais idosos (p<0,001), com historia familiar de DAC(p<0,041), presença de diabetes (p<0,001). A disfunção sistólica(FE<50%) era predominante no grupo de pacientes isquêmicos(77%vs 69%; p=0,048).As classes funcionais mais avançadas(III e IV) foram menos predominantes nos indivíduos isquêmicos(32,5%) em relação aos não isquêmicos(41,3%;p=0,041).O paciente de etiologia isquêmica recebeu tratamento farmacológico semelhante ao não isquêmico com exceção do uso de AAS(p<0,001).Esses indivíduos cursaram com maior numero de internações por outras causas exceto IC(p<0,001) e maior numero de óbitos(p=0,007).Em relação à fração de ejeção, observou-se que indivíduos com FE>50% tinham predomínio do sexo feminino(p=0,006),mais idosos(p<0,001),de etiologia não isquêmica(p=0,048) e classes funcionais I e II(p=0,025).Indivíduos com FE<50% eram mais graves, apresentando maior número de internações por IC(37,8%vs20%;p<0,001), e internações por outras causas(27,2%vs17,5%;p=0,018) e maior número de óbitos (18%vs8,4%;p=0,005) do que os com fração de ejeção preservada. O resultado desse estudo teve como finalidade o conhecimento do perfil de uma população própria, com o objetivo de aprimorar a assistência prestada a ela. Os enfermeiros de Clínicas de IC, juntos com os profissionais da equipe multidisciplinar, desempenham papel fundamental no acompanhamento, orientação e educação desses pacientes.
Resumo:
O período pós-parto pode ser considerado a fase em que a mulher está exposta a retenção de massa corporal (MC) e desenvolvimento da obesidade. Na maioria das situações valorizam-se mais a perda de MC e pouco se conhece a respeito dos componentes que estão sendo mobilizados. Desta forma, há interesse de se validar técnicas acessíveis, como a impedância bioelétrica (BIA), que possam ser aplicadas no acompanhamento nutricional destas mulheres. O presente estudo teve como objetivo validar diferentes modelos de impedância bioelétrica (BIA) para a determinação da composição corporal em mulheres pós-parto tendo como ?padrão ouro? a técnica de absorciometria de dupla energia de raio X(DXA). A amostra foi composta por 46 mulheres no período pós-parto com idade acima de 18anos, inicialmente recrutadas e convidadas a participar da pesquisa, logo após o parto, para posteriormente serem avaliadas. A composição corporal (CC) foi mensurada através de três aparelhos distintos de BIA: RJL , BIO e Tanita e pela DXA. Os componentes101450BC 533corporais medidos foram: massa livre de gordura (MLG), massa gorda (MG) e percentual degordura corporal (%GC). Na análise estatística foram calculadas as médias e desvio-padrãodas variáveis contínuas. A concordância entre os componentes corporais determinados pelaDXA e cada BIA foi avaliada pelo método de Bland & Altman e pelo coeficiente decorrelação de concordância (CCC). Para comparação de médias das variáveis obtidas por BIAe DXA para cada faixa de índice de massa corporal (IMC), foi aplicada a ANOVA e oadotado o teste post-hoc de Tukey. O nível de significância adotado foi de 95% (p=0,05). Amédia ( desvio padrão) de idade foi de 25,5 4,6 anos, a MC de 73,6 12,2kg, o IMC de28,7 4,3kg/m, a MG de 29,87,4kg, a MLG de 43,25,7kg e o %GC de 41,84,3%,obtidos pelo DXA. Ao comparar-se os resultados dos diferentes equipamentos com o método padrão-ouro, verificou-se que houve diferença significativa entre a DXA e as BIA para todos componentes corporais, com exceção da MG fornecida pelo RJL (27,1Kg) e TAN (27,1Kg)em relação à DXA (29,8Kg). Os resultados mostraram haver uma boa reprodutibilidade emrelação aos aparelhos de BIA TAN (r=0,74; r=0,90) e RJL (r=0,78; r=0,89) para MLG e MG.Verificou-se que os equipamentos de BIA TAN e RJL forneceram estimativas semelhantes em relação à MLG, MG e %GC. Em relação aos valores da DXA o equipamento que mais se aproximou foi a TAN e o RJL quando avaliada a MG considerando todas as mulheres, mas quando estratificadas segundo o IMC, a análise foi mais acurada em mulheres obesas.Entretanto, a concordância não foi satisfatória entre os componentes corporais fornecidos pelas BIA em relação à DXA. As BIAs avaliadas no presente estudo subestimaram o %GC e superestimaram a MLG para esse grupo de mulheres no período pós-parto. Conclui-se que as BIA avaliadas não são recomendadas para avaliação da CC neste grupo de mulheres no período pós-parto.
Resumo:
用提拉法成功地生长了6mol%的高浓度掺铒铌酸锂晶体。测量了晶体的两个非偏振方向(X和Z)以及两个偏振方向(π和δ)的吸收光谱。高浓度掺铒铌酸锂晶体的吸收系数高,有利于提高泵浦效率。根据所测的吸收光谱用Judd-Ofelt理论拟合出了Er^3+离子的强度参数Ωλ。所得的均方差结果显示偏振拟合的误差要小于非偏振拟合。利用偏振吸收数据计算了各能级跃迁的自发辐射跃迁几率(AJJ’)、辐射寿命(τ)、荧光分支比(β)和积分发射截面(σp)等参数,对计算结果进行了讨论并与其他文献的报道结果进行了比较。
Resumo:
Ichthyoplankton surveys were conducted in shelf and slope waters of the northern Gulf of Mexico during the months of May–September in 2005 and 2006 to investigate the potential role of this region as spawning and nursery habitat of sailfish (Istiophorus platypterus). During the two-year study, 2426 sailfish larvae were collected, ranging in size from 2.0 to 24.3 mm standard length. Mean density for all neuston net collections (n=288) combined was 1.5 sailfish per 1000 m2, and maximum density was observed within frontal features created by hydrodynamic convergence (2.3 sailfish per 1000 m2). Sagittal otoliths were extracted from 1330 larvae, and otolith microstructure analysis indicated that the sailfish ranged in age from 4 to 24 days after hatching (mean=10.5 d, standard deviation [SD]=3.2 d). Instantaneous growth coefficients (g) among survey periods (n=5) ranged from 0.113 to 0.127, and growth peaked during July 2005 collections when density within frontal features was highest. Daily instantaneous mortality rates (Z) ranged from 0.228 to 0.381, and Z was indexed to instantaneous weight-specific growth (G) to assess stage-specific production potential of larval cohorts. Ratios of G to Z were greater than 1.0 for all but one cohort examined, indicating that cohorts were gaining biomass during the majority of months investigated. Stage-specific production potential, in combination with catch rates and densities of larvae, indicates that the Gulf of Mexico likely represents important spawning and nursery habitat for sailfish.