PURPOSE: To examine the impact of spatial resolution and respiratory motion on the ability to accurately measure atherosclerotic plaque burden and to visually identify atherosclerotic plaque composition. MATERIALS AND METHODS: Numerical simulations of the Bloch equations and vessel wall phantom studies were performed for different spatial resolutions by incrementally increasing the field of view. In addition, respiratory motion was simulated based on a measured physiologic breathing pattern. RESULTS: While a spatial resolution of > or = 6 pixels across the wall does not result in significant errors, a resolution of < or = 4 pixels across the wall leads to an overestimation of > 20%. Using a double-inversion T2-weighted turbo spin echo sequence, a resolution of 1 pixel across equally thick tissue layers (fibrous cap, lipid, smooth muscle) and a respiratory motion correction precision (gating window) of three times the thickness of the tissue layer allow for characterization of the different coronary wall components. CONCLUSIONS: We found that measurements in low-resolution black blood images tend to overestimate vessel wall area and underestimate lumen area.
Resumo:
PURPOSE: To prospectively compare various parameters of vessels imaged at 3 T by using time-of-flight (TOF) and T2-prepared magnetic resonance (MR) angiography in a rabbit model of hind limb ischemia. MATERIALS AND METHODS: Experiments were approved by the institutional animal care and use committee. Endovascular occlusion of the left superficial femoral artery was induced in 14 New Zealand white rabbits. After 2 weeks, MR angiography and conventional (x-ray) angiography were performed. Vessel sharpness was evaluated visually in the ischemic and nonischemic limbs, and the presence of small collateral vessels was evaluated in the ischemic limbs. Vessel sharpness was also quantified by evaluating the magnitude of signal intensity change at the vessel borders. RESULTS: The sharpness of vessels in the nonischemic limbs was similar between the TOF and the T2-prepared images. In the ischemic limbs, however, T2-prepared imaging, as compared with TOF imaging, generated higher vessel sharpness in arteries with diminished blood flow (mean vessel sharpness: 44% vs 30% for popliteal arteries, 45% vs 28% for saphenous arteries; P < .001 for both comparisons) and enabled better detection of small collateral vessels (93% vs 36% of vessels, P < .001). CONCLUSION: T2-prepared imaging can facilitate high-spatial-resolution MR angiography of small vessels with low blood flow and thus has potential as a tool for noninvasive evaluation of arteriogenic therapies, without use of contrast material. Supplemental material: http://radiology.rsnajnls.org/cgi/content/full/2452062067/DC1.
Resumo:
BACKGROUND: The Advisa MRI system is designed to safely undergo magnetic resonance imaging (MRI). Its influence on image quality is not well known. OBJECTIVE: To evaluate cardiac magnetic resonance (CMR) image quality and to characterize myocardial contraction patterns by using the Advisa MRI system. METHODS: In this international trial with 35 participating centers, an Advisa MRI system was implanted in 263 patients. Of those, 177 were randomized to the MRI group and 150 underwent MRI scans at the 9-12-week visit. Left ventricular (LV) and right ventricular (RV) cine long-axis steady-state free precession MR images were graded for quality. Signal loss along the implantable pulse generator and leads was measured. The tagging CMR data quality was assessed as the percentage of trackable tagging points on complementary spatial modulation of magnetization acquisitions (n=16) and segmental circumferential fiber shortening was quantified. RESULTS: Of all cine long-axis steady-state free precession acquisitions, 95% of LV and 98% of RV acquisitions were of diagnostic quality, with 84% and 93%, respectively, being of good or excellent quality. Tagging points were trackable from systole into early diastole (360-648 ms after the R-wave) in all segments. During RV pacing, tagging demonstrated a dyssynchronous contraction pattern, which was not observed in nonpaced (n = 4) and right atrial-paced (n = 8) patients. CONCLUSIONS: In the Advisa MRI study, high-quality CMR images for the assessment of cardiac anatomy and function were obtained in most patients with an implantable pacing system. In addition, this study demonstrated the feasibility of acquiring tagging data to study the LV function during pacing.
Local re-inversion coronary MR angiography: arterial spin-labeling without the need for subtraction.
Resumo:
PURPOSE: To implement a double-inversion bright-blood coronary MR angiography sequence using a cylindrical re-inversion prepulse for selective visualization of the coronary arteries. MATERIALS AND METHODS: Local re-inversion bright-blood magnetization preparation was implemented using a nonselective inversion followed by a cylindrical aortic re-inversion prepulse. After an inversion delay that allows for in-flow of the labeled blood-pool into the coronary arteries, three-dimensional radial steady-state free-precession (SSFP) imaging (repetition/echo time, 7.2/3.6 ms; flip angle, 120 degrees, 16 profiles per RR interval; field of view, 360 mm; matrix, 512, twelve 3-mm slices) is performed. Coronary MR angiography was performed in three healthy volunteers and in one patient on a commercial 1.5 Tesla whole-body MR System. RESULTS: In all subjects, coronary arteries were selectively visualized with positive contrast. In addition, a middle-grade stenosis of the proximal right coronary artery was seen in one patient. CONCLUSION: A novel T1 contrast-enhancement strategy is presented for selective visualization of the coronary arteries without extrinsic contrast medium application. In comparison to former arterial spin-labeling schemes, the proposed magnetization preparation obviates the need for a second data set and subtraction.
Resumo:
Référence bibliographique : Rol, 55781
Resumo:
The prognostic significance of magnetic resonance imaging (MRI) in the neonatal period was studied prospectively in 43 term infants with perinatal asphyxia. MRI was performed between 1 and 14 days after birth with a high field system (2.35 Tesla). Neurodevelopmental outcome was assessed by a standardized neurological examination and the Griffiths developmental test at a mean age of 18.9 months. The predictive value of the various MRI patterns was as follows: Severe diffuse brain injury (pattern AII+III; n = 7) and lesions of thalamus and basal ganglia (pattern C; n = 5) were strongly associated with poor outcome and greatly reduced head growth. Mild diffuse brain injury (pattern AI; n = 7), parasagittal lesions (B; n = 7), periventricular hyperintensity (D; n = 2), focal brain necrosis and hemorrhage (E; n = 3) and periventricular hypointense stripes (on T2-weighted images; F; n = 3) led in one third of the infants to minor neurological disturbances and mild developmental delay. Infants with normal MRI findings (G; n = 9) developed normally with the exception of one infant who was mildly delayed at 18 months. The results indicate that MRI examination during the first two weeks of life is of prognostic significance in term infants suffering from perinatal asphyxia. Severe hypoxic-ischemic brain lesions were associated highly significantly with poor neuro-developmental outcome, whereas infants with inconspicuous MRI developed normally.
Resumo:
For the development and evaluation of cardiac magnetic resonance (MR) imaging sequences and methodologies, the availability of a periodically moving phantom to model respiratory and cardiac motion would be of substantial benefit. Given the specific physical boundary conditions in an MR environment, the choice of materials and power source of such phantoms is heavily restricted. Sophisticated commercial solutions are available; however, they are often relatively costly and user-specific modifications may not easily be implemented. We therefore sought to construct a low-cost MR-compatible motion phantom that could be easily reproduced and had design flexibility. A commercially available K'NEX construction set (Hyper Space Training Tower, K'NEX Industries, Inc., Hatfield, PA) was used to construct a periodically moving phantom head. The phantom head performs a translation with a superimposed rotation, driven by a motor over a 2-m rigid rod. To synchronize the MR data acquisition with phantom motion (without introducing radiofrequency-related image artifacts), a fiberoptic control unit generates periodic trigger pulses synchronized to the phantom motion. Total material costs of the phantom are US$ < 200.00, and a total of 80 man-hours were required to design and construct the original phantom. With schematics of the present solution, the phantom reproduction may be achieved in approximately 15 man-hours. The presented MR-compatible periodically moving phantom can easily be reproduced, and user-specific modifications may be implemented. Such an approach allows a detailed investigation of motion-related phenomena in MR images.
Resumo:
Aim. Several software packages (SWP) and models have been released for quantification of myocardial perfusion (MP). Although they all are validated against something, the question remains how well their values agree. The present analysis focused on cross-comparison of three SWP for MP quantification of 13N-ammonia PET studies. Materials & Methods. 48 rest and stress MP 13N-ammonia PET studies of hypertrophic cardiomyopathy (HCM) patients (Sciagrà et al., 2009) were analysed with three SW packages - Carimas, PMOD, and FlowQuant - by three observers blinded to the results of each other. All SWP implement the one-tissue-compartment model (1TCM, DeGrado et al. 1996), and first two - the two-tissue-compartment model (2TCM, Hutchins et al. 1990) as well. Linear mixed model for the repeated measures was fitted to the data. Where appropriate we used Bland-Altman plots as well. The reproducibility was assessed on global, regional and segmental levels. Intraclass correlation coefficients (ICC), differences between the SWPs and between models were obtained. ICC≥0.75 indicated excellent reproducibility, 0.4≤ICC<0.75 indicated fair to good reproducibility, ICC<0.4 - poor reproducibility (Rosner, 2010). Results. When 1TCM MP values were compared, the SW agreement on global and regional levels was excellent, except for Carimas vs. PMOD at RCA: ICC=0.715 and for PMOD vs. FlowQuant at LCX:ICC=0.745 which were good. In segmental analysis in five segments: 7,12,13, 16, and 17 the agreement between all SWP was excellent; in the remaining 12 segments the agreement varied between the compared SWP. Carimas showed excellent agreement with FlowQuant in 13 segments and good in four - 1, 5, 6, 11: 0.687≤ICCs≤0.73; Carimas had excellent agreement with PMOD in 11 segments, good in five_4, 9, 10, 14, 15: 0.682≤ICCs≤0.737, and poor in segment 3: ICC=0.341. PMOD had excellent agreement with FlowQuant in eight segments and substantial-to-good in nine_1, 2, 3, 5, 6,8-11: 0.585≤ICCs≤0.738. Agreement between Carimas and PMOD for 2TCM was good at a global level: ICC=0.745, excellent at LCX (0.780) and RCA (0.774), good at LAD (0.662); agreement was excellent for ten segments, fair-to-substantial for segments 2, 3, 8, 14, 15 (0.431≤ICCs≤0.681), poor for segments 4 (0.384) and 17 (0.278). Conclusions. The three SWP used by different operators to analyse 13N-ammonia PET MP studies provide results that agree well at a global level, regional levels, and mostly well even at a segmental level. Agreement is better for 1TCM. Poor agreement at segments 4 and 17 for 2TCM needs further clarification.
Resumo:
This paper presents a validation study on statistical nonsupervised brain tissue classification techniques in magnetic resonance (MR) images. Several image models assuming different hypotheses regarding the intensity distribution model, the spatial model and the number of classes are assessed. The methods are tested on simulated data for which the classification ground truth is known. Different noise and intensity nonuniformities are added to simulate real imaging conditions. No enhancement of the image quality is considered either before or during the classification process. This way, the accuracy of the methods and their robustness against image artifacts are tested. Classification is also performed on real data where a quantitative validation compares the methods' results with an estimated ground truth from manual segmentations by experts. Validity of the various classification methods in the labeling of the image as well as in the tissue volume is estimated with different local and global measures. Results demonstrate that methods relying on both intensity and spatial information are more robust to noise and field inhomogeneities. We also demonstrate that partial volume is not perfectly modeled, even though methods that account for mixture classes outperform methods that only consider pure Gaussian classes. Finally, we show that simulated data results can also be extended to real data.
Resumo:
[Traditions. Asie. Inde]
Resumo:
Background: It is unknown whether cerebral perfusion in geriatric and younger patients under general anaesthesia differs. Methods: We compared 2 groups of patients undergoing elective major non-cardiac surgery under standardized general anaesthesia (thiopental, sevoflurane, fentanyl, atracurium). Group 1: 18-40 yrs (n = 20), Group 2: >65 yrs (n = 37). Cerebral perfusion was investigated with transcranial Doppler and near-infrared spectroscopy (NIRS). Arterial blood pressure was monitored continuously with a Finapres device. Mx, an index allowing continuous monitoring of cerebrovascular autoregulation based on the changes in mean arterial blood pressure (MAP) and cerebral blood flow velocity was calculated. Data are shown as mean } SD. Results: MAP (86 } 9.6 vs 79 } 10.9 mm Hg, p = 0.02), end-tidal concentration of sevoflurane (1.9 } 0.3 vs 1.6 } 0.3%, p <0.01), and the cerebral tissue oxygenation index measured by NIRS (72 } 4 vs 68 } 5%, p = 0.01), were significantly lower in Group 2. The end-tidal concentration of O2 was significantly higher in Group 2 (46 } 4 vs 48 } 4% p = 0.04). There were no significant differences between Group 1 and 2 for cerebral blood flow velocity (41 } 10 vs 43 } 18 cm/s), end tidal CO2 (4.7 } 0.3 vs 4.6 } 0.3 kPa) and cerebrovascular autoregulation (Mx 0.42 } 0.2 vs 0.48 } 0.2). In Group 1 35% and in Group 2 43% of the patients had an index of autoregulation suggesting disturbed cerebrovascular autoregulation (p = n.s.). Conclusions: In elderly patients under general anaesthesia with sevoflurane the cerebral tissue oxygenation index was significantly lower than in younger patients despite higher end-tidal oxygen concentrations. Our data suggest subtle differences in cerebral perfusion between geriatric and younger