952 resultados para M2-m3 Loop


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The purpose of this study was to use photoelastic analysis to compare the system of forces generated by retraction T-loop springs made with stainless steel and titanium-molybdenum alloy (TMA) (Ormco, Glendora, Calif) with photoelastic analysis. Methods: Three photoelastic models were used to evaluate retraction T-loop springs with the same preactivations in 2 groups. In group 1, the loop was constructed with a stainless steel wire, and 2 helicoids were incorporated on top of the T-loop; in group 2, it was made with TMA and no helicoids. Results: Upon using the qualitative analysis of the fringe order in the photoelastic model, it was observed that the magnitude of force generated by the springs in group 1 was significantly higher than that in group 2. However, both had symmetry for the active and reactive units related to the system of force. Conclusions: Both springs had the same mechanical characteristics. TMA springs showed lower force levels. (Am J Orthod Dentofacial Orthop 2011;140:e123-e128)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare the system of forces acting on curvature and preactivated V-bends in titanium T-loop springs (TTLSs) made of 0.017- X 0.025-inch TMA (titanium molibdenium alloy) wire.Materials and Methods: Pictures of TTLSs preactivated by curvature and V-bends were inserted in the LOOP software program to design both TTLSs. Symmetry was assured using the program. Both TTLSs used the same amount (length) of wire and had the same angulation between their anterior and posterior extremities when passive. The loops were activated 7 mm, and forces and moments were registered after each 0.5 mm of deactivation. The brackets were at the same height, separated by 23 mm and angulated 0 degrees.Results: The preactivated curvature TTLS delivered horizontal forces ranging from 34 gF to 456 gF, while the TTLS preactivated by V-bends delivered forces ranging from 54 gF to 517 gF. The forces decreased more (30 gF vs 33 gF) with every 0.5 mm of activation on the preactivated V-bend TTLS than on the preactivated curvature TTLS. Vertical forces were low and clinically insignificant for both TTLSs. The moment to force (MF) ratios were systematically higher on the preactivated curvature than on the preactivated V-bend TTLS (from 5.8 mm to 38.8 mm vs 4.7 mm to 28.3 mm).Conclusions: Although both loops show symmetrical moments in their anterior and posterior extremities and can be used for group B anchorage, the curvature preactivated TTLS delivers lower horizontal forces and higher MF ratios than the acute preactivated V-bend TTLS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ATMA (Ormco Corp, Glendora, Calif) T-loop spring (TTLS), preactivated with a gable bend distal to the loop, holds promise for producing controlled tipping of the canines and translation of the posterior segment. However, there is currently no consensus as to where the preactivated gable bend or the loop should be placed, what the height of the loop should be, or how the interbracket distance changes the moments produced. Using the Loop software program (dHal, Athens, Greece), we systematically modified a .017 x .025-in TTLS (10 x 6 mm) that was preactivated with a 45 degrees gable bend distal to the loop, and simulated the effects. As the gable bend was moved posteriorly, the moment increased at the posterior bracket more than it decreased at the anterior bracket. As the loop was brought closer to the anterior bracket, the posterior moment decreased at the same rate that it increased anteriorly. As the loop was increased in size, the moments increased both posteriorly and anteriorly. As the interbracket distance increased, the posterior moment decreased, and the anterior moment remained constant. We concluded that the size of the loop should be slightly increased, to 10 x 7 mm, and it should be placed 2 mm from the anterior bracket, with a preactivation bend of 45 degrees, 4 to 5 mm from the posterior bracket (after 4 mm of activation).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Objectives - A controversy exists in the literature regarding the effects of the acute administration of magnesium on the cardiovascular system of animals and humans. The purpose of this study was to evaluate the effects of hypermagnesemia on the cardiovascular hemodynamics of dogs. Methods - Sixteen mongrel dogs were anesthetized with pentobarbitone 30 mg.kg-1 and submitted to volume expansion with Ringer's solution (0.4 ml.kg-1.min-1 and mechanical ventilation with room air. In this model, the hemodynamic repercussions of the following drugs and doses were studied. pentobarbitone 5 mg.kg-1 Group 1, control - and the association of pentobarbitone and magnesium sulphate (MS), at the dose of 140 mg.kg-1 injected in 15 minutes, followed by an infusion of 80 mg.kg-1.h-1 - Group 2. The parameters studied were: heart rate, blood pressure, inferior vena cava pressure, cardiac index, systolic index and peripheral resistance index, evaluated at 5 different moments: 15(M1), 30(M2), 60(M3) and 75(M4) minutes after the first suppplementary dose of pentobarbitone and 15 minutes (M5) after the second supplementary dose. In Group 2, the moments M3, M4, M5 corresponded to 15, 30 and 60 minutes after the priming dose of magnesium sulphate. Results - Group 1 animals exhibited tachycardia since the beginning of the experiment. There was a decrease in the cardiac index, in the systolic index and an increase in the inferior vena cava pressure. Group 2 animals also exhibited tachycardia, but heart rate decreased after MS infusion. The blood pressure and the peripheral resistance index decreased. The systolic index increased and the cardiac index decreased only at the end of the experiment. Conclusions: The antiadrenergic effects of MS could have been responsible for the decrease in heart rate. The vasodilating effects of the magnesium induced the decrease in the peripheral resistance index. The systolic index increased, showing that myocardial depression did not occur.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and objectives - The use of magnesium sulphate for the prevention of seizures in pre-eclampsia may induce hypermagnesemia. Clinical and experimental studies are not in agreement about the effects of magnesium on the renal hemodynamics and function. We therefore studied the effects of hypermagnesemia on the renal hemodynamics and function of dogs anesthetized with pentobarbitone. Methods - Sixteen mongrel dogs were anesthetized with pentobarbitone 30 mg.kg-1 and submitted to extracellular ) and mechanical ventilation with room air. The dogs were volume expansion with Ringer's solution (0.4 ml.kg.min allocated into two groups of 8 animals, for the study of renal hemodynamics and function following the administration of 5 mg.kg-1 of pentobarbitone (Group 1 - control or of pentobarbitone associated with magnesium sulphate in the dose (Group 2). The parameters studied were: PAH of 140 mg.kg, administered in 15 minutes, followed by 80 mg.kg-1.h-1 clearance, creatinine clearance, osmolar clearance, free water clearance, renal blood flow, renal vascular resistance, filtration fraction, urinary volume, plasmatic and urinary osmolarity, urinary and fractionary excretion of sodium and potassium, measured at five moments: 15 (M1), 30 (M2), 60 (M3) and 75 (M4) minutes after the first supplementary dose of pentobarbitone and 15 minutes (M5) after the second supplementary dose in Group 1. In Group 2, the moments M3, M4, M5 were 15, 30 and 60 minutes after the priming dose of magnesium sulphate and during the maintenance dose. Results - In Group I no significant changes were observed in renal hemodynamic parameters and creatinine clearance. The extracellular volume expansion increased urinary volume and decreased urinary osmolarity as a consequence of sodium, potassium and free water clearance. The fractionary excretion of sodium was maintained. The plasmatic osmolarity increased. In Group 2, renal hemodynamic parameters and creatinine clearance were also maintained. There was an increase in renal sodium clearance, as detected by the increase in the fractionary excretion of sodium. Conclusions - Magnesium sulphate did not produce significant changes in renal hemodynamics and facilitated the renal excretion of sodium in dogs anesthetized with pentobarbitone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we calculate two two-loop massless Feynman integrals pertaining to self-energy diagrams using NDIM (Negative Dimensional Integration Method). We show that the answer we get is 36-fold degenerate. We then consider special cases of exponents for propagators and the outcoming results compared with known ones obtained via traditional methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The negative-dimensional integration method (NDIM) seems to be a very promising technique for evaluating massless and/or massive Feynman diagrams. It is unique in the sense that the method gives solutions in different regions of external momenta simultaneously. Moreover, it is a technique whereby the difficulties associated with performing parametric integrals in the standard approach are transferred to a simpler solving of a system of linear algebraic equations, thanks to the polynomial character of the relevant integrands. We employ this method to evaluate a scalar integral for a massless two-loop three-point vertex with all the external legs off-shell, and consider several special cases for it, yielding results, even for distinct simpler diagrams. We also consider the possibility of NDIM in non-covariant gauges such as the light-cone gauge and do some illustrative calculations, showing that for one-degree violation of covariance (i.e. one external, gauge-breaking, light-like vector n μ) the ensuing results are concordant with the ones obtained via either the usual dimensional regularization technique, or the use of the principal value prescription for the gauge-dependent pole, while for two-degree violation of covariance - i.e. two external, light-like vectors n μ, the gauge-breaking one, and (its dual) n * μ - the ensuing results are concordant with the ones obtained via causal constraints or the use of the so-called generalized Mandelstam-Leibbrandt prescription. © 1999 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, many researchers in the field of biomedical sciences have made successful use of mathematical models to study, in a quantitative way, a multitude of phenomena such as those found in disease dynamics, control of physiological systems, optimization of drug therapy, economics of the preventive medicine and many other applications. The availability of good dynamic models have been providing means for simulation and design of novel control strategies in the context of biological events. This work concerns a particular model related to HIV infection dynamics which is used to allow a comparative evaluation of schemes for treatment of AIDS patients. The mathematical model adopted in this work was proposed by Nowak & Bangham, 1996 and describes the dynamics of viral concentration in terms of interaction with CD4 cells and the cytotoxic T lymphocytes, which are responsible for the defense of the organism. Two conceptually distinct techniques for drug therapy are analyzed: Open Loop Treatment, where a priori fixed dosage is prescribed and Closed Loop Treatment, where the doses are adjusted according to results obtained by laboratory analysis. Simulation results show that the Closed Loop Scheme can achieve improved quality of the treatment in terms of reduction in the viral load and quantity of administered drugs, but with the inconvenience related to the necessity of frequent and periodic laboratory analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the possibility that four-fermion contact interactions give rise to the observed deviation from the standard model prediction for the weak charge of cesium, through one-loop contributions. We show that the presence of loops involving the third generation quarks can explain such a deviation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We apply the negative dimensional integration method (NDIM) to three outstanding gauges: Feynman, light-cone, and Coulomb gauges. Our aim is to show that NDIM is a very suitable technique to deal with loop integrals, regardless of which gauge choice that originated them. In the Feynman gauge we perform scalar two-loop four-point massless integrals; in the light-cone gauge we calculate scalar two-loop integrals contributing to two-point functions without any kind of prescriptions, since NDIM can abandon such devices - this calculation is the first test of our prescriptionless method beyond one-loop order; and finally, for the Coulomb gauge we consider a four-propagator massless loop integral, in the split-dimensional regularization context. © 2001 Academic Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is proven that the pure spinor superstring in an AdS5 × S5 background remains conformally invariant at one loop level in the sigma model perturbation theory. © SISSA/ISAS 2003.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: Pressure controlled ventilation (PCV) is available in anesthesia machines, but there are no studies on its use during CO 2 pneumoperitoneum (CPP). This study aimed at evaluating pressure-controlled ventilation and hemodynamic and ventilatory changes during CPP, as compared to conventional volume controlled ventilation (VCV). METHODS: This study involved 16 dogs anesthetized with thiopental, fentanyl and pancuronium, which were randomly assigned to two groups: VC - volume controlled ventilation (n=8) and PC - pressure controlled ventilation (n=8). Hemodynamic and ventilatory parameters were monitored and recorded in 4 moments: M1 (before CPP), M2 (30 minutes after CPP = 10 mmHg), M3 (30 minutes after CPP=15 mmHg) and M4 (30 minutes after deflation). RESULTS: With CPP, there has been significant increase in tidal volume in PC group; there has been increase in airway pressures (peak and plateau), decrease in compliance with increase in CPP pressure, increase in heart rate, maintenance of mean blood pressure with higher values in the VC group in all stages; there was also increase in right atrium pressure with significant decrease after deflation, decrease in arterial pH with minor variations in PC group, greater arterial pCO 2 stability in PC group, and no significant changes in arterial pO 2. CONCLUSIONS: There were some differences in hemodynamic and ventilatory data between both ventilation control modes (VC and PC). It is possible to use pressure controlled ventilation during CPP, but the anesthesiologist must monitor and take a close look at alveolar ventilation, adjusting inspiratory pressure to ensure proper CO 2 elimination and oxygenation. © Sociedade Brasileira de Anestesiologia, 2005.