876 resultados para Load voltage maximization
Resumo:
A high-frequency cyclonverter acts as a direct ac-to-ac power converter circuit that does not require a diode bidge rectifier. Bridgeless topology makes it possible to remove forward voltage drop losses that are present in a diode bridge. In addition, the on-state losses can be reduced to 1.5 times the on-state resistance of switches in half-bridge operation of the cycloconverter. A high-frequency cycloconverter is reviewed and the charging effect of the dc-capacitors in ``back-to-back'' or synchronous mode operation operation is analyzed. In addition, a control method is introduced for regulating dc-voltage of the ac-side capacitors in synchronous operation mode. The controller regulates the dc-capacitors and prevents switches from reaching overvoltage level. This can be accomplished by variating phase-shift between the upper and the lower gate signals. By adding phase-shift between the gate signal pairs, the charge stored in the energy storage capacitors can be discharged through the resonant load and substantially, the output resonant current amplitude can be improved. The above goals are analyzed and illustrated with simulation. Theory is supported with practical measurements where the proposed control method is implemented in an FPGA device and tested with a high-frequency cycloconverter using super-junction power MOSFETs as switching devices.
Resumo:
The effect of the skin secretion of the amphibian Siphonops paulensis was investigated by monitoring the changes in conductance of an artificial planar lipid bilayer. Skin secretion was obtained by exposure of the animals to ether-saturated air, and then rinsing the animals with distilled water. Artificial lipid bilayers were obtained by spreading a solution of azolectin over an aperture of a Delrin cup inserted into a cut-away polyvinyl chloride block. In 9 of 12 experiments, the addition of the skin secretion to lipid bilayers displayed voltage-dependent channels with average unitary conductance of 258 ± 41.67 pS, rather than nonspecific changes in bilayer conductance. These channels were not sensitive to 4-acetamido-4'-isothiocyanatostilbene-2,2'-disulfonic acid or tetraethylammonium ion, but the experimental protocol used does not permit us to specify their characteristics.
Resumo:
The aim of the present study was to assess the spectral behavior of the erector spinae muscle during isometric contractions performed before and after a dynamic manual load-lifting test carried out by the trunk in order to determine the capacity of muscle to perform this task. Nine healthy female students participated in the experiment. Their average age, height, and body mass (± SD) were 20 ± 1 years, 1.6 ± 0.03 m, and 53 ± 4 kg, respectively. The development of muscle fatigue was assessed by spectral analysis (median frequency) and root mean square with time. The test consisted of repeated bending movements from the trunk, starting from a 45º angle of flexion, with the application of approximately 15, 25 and 50% of maximum individual load, to the stand up position. The protocol used proved to be more reliable with loads exceeding 50% of the maximum for the identification of muscle fatigue by electromyography as a function of time. Most of the volunteers showed an increase in root mean square versus time on both the right (N = 7) and the left (N = 6) side, indicating a tendency to become fatigued. With respect to the changes in median frequency of the electromyographic signal, the loads used in this study had no significant effect on either the right or the left side of the erector spinae muscle at this frequency, suggesting that a higher amount and percentage of loads would produce more substantial results in the study of isotonic contractions.
Resumo:
the response to an oral calcium load test was assessed in 17 hypercalciuric nephrolithiasis patients who presented elevated parathyroid hormone (PTH) irrespective of the ionized calcium (sCa2+) levels. Blood samples were collected at baseline (0 min) and at 60 and 180 min after 1 g calcium load for serum PTH, total calcium, sCa2+, and 1.25(OH)2D3 determinations. According to the sCa2+ level at baseline, patients were classified as normocalcemic (N = 9) or hypercalcemic (N = 8). Six healthy subjects were also evaluated as controls. Bone mineral density was reduced in 14/17 patients. In the normocalcemic group, mean PTH levels at 0, 60 and 180 min (95 ± 76, 56 ± 40, 57 ± 45 pg/ml, respectively) did not differ from the hypercalcemic group (130 ± 75, 68 ± 35, 80 ± 33 pg/ml) but were significantly higher compared to healthy subjects despite a similar elevation in sCa2+ after 60 and 180 min vs baseline in all 3 groups. Mean total calcium and 1.25(OH)2D3 were similar in the 3 groups. Additionally, we observed that 5 of 9 normocalcemic patients presented a significantly higher concentration-time curve for serum PTH (AUC0',60',180') than the other 4 patients and the healthy subjects, suggesting a primary parathyroid dysfunction. These data suggest that the individual response to an oral calcium load test may be a valuable dynamic tool to disclose a subtle primary hyperparathyroidism in patients with high PTH and fluctuating sCa2+ levels, avoiding repeated measurements of both parameters.
Resumo:
To evaluate the human T-cell lymphotropic virus type I (HTLV-I) proviral DNA load among asymptomatic HTLV-I-infected carriers and patients with HTLV-I-associated myelopathy/tropical spastic paraparesis (HAM/TSP), real time PCR using TaqMan probes for the pol gene was performed in two million peripheral blood mononuclear cells (PBMC). The albumin gene was the internal genomic control and MT2 cells were used as positive control. The results are reported as copies/10,000 PBMC, and the detection limit was 10 copies. A total of 89 subjects (44 HAM/TSP and 45 healthy HTLV-I-infected carriers) followed up at the Institute of Infectious Diseases "Emilio Ribas" and in the Neurology Division of Hospital of Clínicas were studied. The asymptomatic HTLV-I-infected carriers had a median number of 271 copies (ranging from 5 to 4756 copies), whereas the HAM/TSP cases presented a median of 679 copies (5-5360 copies) in 10,000 PBMC. Thus, HAM/TSP patients presented a significantly higher HTLV-I proviral DNA load than healthy HTLV-I carriers (P = 0.005, one-way Mann-Whitney test). As observed in other persistent infections, proviral DNA load quantification may be an important tool for monotoring HTLV-I-infected subjects. However, long-term follow-up is necessary to validate this assay in the clinical setting.
Resumo:
This thesis is made in cooperation with Laboratory of Steel Structures and the steel company SSAB. Maximization of the benefits of high-strength steel usually requires the usage of thin wall thicknesses. This means the failures related to buckling, distortion and warping stand out. One must be aware of these phenomena to design thin-walled structures stressed with forces such as torsional loading. It is also important to take into account small stress ranges when evaluating the accurate fatigue strength of structures. The objective of this thesis is to clarify the theory of the uniform and non-uniform torsion. This paper focuses on warping due to the non-uniform torsion in double symmetric box girder and structural hollow section. The arisen stress states are explained and researched using the finite element method. Another research target is the distortion in double symmetric box girder due to torsion, and the restraining effect of transverse diaphragms at the load end. Multiple transverse diaphragms are used to study more efficient restraining against warping and distortion than a common one end plate structure.
Resumo:
Medium-voltage motor drives extend the power rating of AC motor drives in industrial applications. Multilevel converters are gaining an ever-stronger foothold in this field. This doctoral dissertation introduces a new topology to the family of modular multilevel converters: the modular double-cascade converter. The modularity of the converter is enabled by the application of multiwinding mediumfrequency isolation transformers. Owing to the innovative transformer link, the converter presents many advantageous properties at a concept level: modularity, high input and output power quality, small footprint, and wide variety of applications, among others. Further, the research demonstrates that the transformer link also plays a key role in the disadvantages of the topology. An extensive simulation study on the new converter is performed. The focus of the simulation study is on the development of control algorithms and the feasibility of the topology. In particular, the circuit and control concepts used in the grid interface, the coupling configurations of the load inverter, and the transformer link operation are thoroughly investigated. Experimental results provide proof-of-concept results on the operation principle of the converter. This work concludes a research collaboration project on multilevel converters between LUT and Vacon Plc. The project was active from 2009 until 2014.
Resumo:
Salvador (BA, Brazil) is an endemic area for human T-cell lymphotrophic virus type 1 (HTLV-1). The overall prevalence of HTLV-1 infection in the general population has been estimated to be 1.76%. HTLV-1 carriers may develop a variety of diseases such as adult T-cell leukemia/lymphoma, HTLV-1-associated myelopathy/tropical spastic paraparesis (HAM/TSP) and infective dermatitis associated with HTLV-1 (IDH). IDH is a chronic and severe form of childhood exudative and infective dermatitis involving mainly the scalp, neck and ears. It has recently been observed that 30% of patients with IDH develop juvenile HAM/TSP. The replication of HTLV-1 has been reported to be greater in adult HAM/TSP patients than in asymptomatic HTLV-1 carriers. In the current study, the proviral load of 28 children and adolescents with IDH not associated with HAM/TSP was determined and the results were compared to those obtained in 28 HTLV-1 adult carriers and 28 adult patients with HAM/TSP. The proviral load in IDH patients was similar to that of patients with HAM/TSP and much higher than that found in HTLV-1 carriers. The high levels of proviral load in IDH patients were not associated with age, duration of illness, duration of breast-feeding, or activity status of the skin disease. Since proviral load is associated with neurological disability, these data support the view that IDH patients are at high risk of developing HAM/TSP.
Resumo:
The growing population in cities increases the energy demand and affects the environment by increasing carbon emissions. Information and communications technology solutions which enable energy optimization are needed to address this growing energy demand in cities and to reduce carbon emissions. District heating systems optimize the energy production by reusing waste energy with combined heat and power plants. Forecasting the heat load demand in residential buildings assists in optimizing energy production and consumption in a district heating system. However, the presence of a large number of factors such as weather forecast, district heating operational parameters and user behavioural parameters, make heat load forecasting a challenging task. This thesis proposes a probabilistic machine learning model using a Naive Bayes classifier, to forecast the hourly heat load demand for three residential buildings in the city of Skellefteå, Sweden over a period of winter and spring seasons. The district heating data collected from the sensors equipped at the residential buildings in Skellefteå, is utilized to build the Bayesian network to forecast the heat load demand for horizons of 1, 2, 3, 6 and 24 hours. The proposed model is validated by using four cases to study the influence of various parameters on the heat load forecast by carrying out trace driven analysis in Weka and GeNIe. Results show that current heat load consumption and outdoor temperature forecast are the two parameters with most influence on the heat load forecast. The proposed model achieves average accuracies of 81.23 % and 76.74 % for a forecast horizon of 1 hour in the three buildings for winter and spring seasons respectively. The model also achieves an average accuracy of 77.97 % for three buildings across both seasons for the forecast horizon of 1 hour by utilizing only 10 % of the training data. The results indicate that even a simple model like Naive Bayes classifier can forecast the heat load demand by utilizing less training data.
Resumo:
With the new age of Internet of Things (IoT), object of everyday such as mobile smart devices start to be equipped with cheap sensors and low energy wireless communication capability. Nowadays mobile smart devices (phones, tablets) have become an ubiquitous device with everyone having access to at least one device. There is an opportunity to build innovative applications and services by exploiting these devices’ untapped rechargeable energy, sensing and processing capabilities. In this thesis, we propose, develop, implement and evaluate LoadIoT a peer-to-peer load balancing scheme that can distribute tasks among plethora of mobile smart devices in the IoT world. We develop and demonstrate an android-based proof of concept load-balancing application. We also present a model of the system which is used to validate the efficiency of the load balancing approach under varying application scenarios. Load balancing concepts can be apply to IoT scenario linked to smart devices. It is able to reduce the traffic send to the Cloud and the energy consumption of the devices. The data acquired from the experimental outcomes enable us to determine the feasibility and cost-effectiveness of a load balanced P2P smart phone-based applications.
Resumo:
Energy efficiency is an important topic when considering electric motor drives market. Although more efficient electric motor types are available, the induction motor remains as the most common industrial motor type. IEC methods for determining losses and efficiency of converter-fed induction motors were introduced recently with the release of technical specification IEC/TS 60034-2-3. Determining the induction motor losses with IEC/TS 60034-2-3 method 2-3-A and assessing the practical applicability of the method are the main interests of this study. The method 2-3-A introduces a specific test converter waveform to be used in the measurements. Differences between the induction motor losses with a test converter supply, and with a DTC converter supply are investigated. In the IEC methods, the tests are run at motor rated fundamental voltage, which, in practice, requires the frequency converter to be fed with a risen input voltage. In this study, the tests are run on both frequency converters with artificially risen converter input voltage, resulting in rated motor fundamental input voltage as required by IEC. For comparison, the tests are run with both converters on normal grid input voltage supply, which results in lower motor fundamental voltage and reduced flux level, but should be more relevant from practical point of view. According to IEC method 2-3-A, tests are run at rated motor load, and to ensure comparability of the results, the rated load is used in the grid-fed converter measurements, although motor is overloaded while producing the rated torque at reduced flux level. The IEC 2-3-A method requires also sinusoidal supply test results with IEC method 2-1-1B. Therefore, the induction motor losses with the recently updated IEC 60034-2-1 method 2-1-1B are determined at the motor rated voltage, but also at two lower motor voltages, which are according to the output fundamental voltages of the two network-supplied converters. The method 2-3-A was found to be complex to apply but the results were stable. According to the results, the method 2-3-A and the test converter supply are usable for comparing losses and efficiency of different induction motors at the operating point of rated voltage, rated frequency and rated load, but the measurements do not give any prediction of the motor losses at final application. One might therefore strongly criticize the method’s main principles. It seems, that the release of IEC 60034-2-3 as a technical specification instead of a final standard for now was justified, since the practical relevance of the main method is questionable.
Resumo:
F/A-18-monitoimihävittäjän ohjaajan tehtävän kognitiiviset vaatimukset ovat korkeat. Kognitiivisen kuormituksen taso vaikuttaa hävittäjäohjaajan suoritustasoon ja subjektiivisiin tun-temuksiin. Yerkesin ja Dodsonin periaatteen mukaisesti erittäin matala tai erittäin korkea kuormituksen taso laskee suoritustasoa. Optimaalinen kuormituksen taso ja suoritustaso saa-vutetaan jossain ääripäiden välillä. Hävittäjäohjaajan kognitiivisen kuormituksen tasoon vaikuttaa lentotehtävän suorittamiseen vaadittava henkinen ponnistelu. Vaadittavan ponnistelun taso riippuu tehtävien vaatimustasosta ja määrästä, tehtäviin käytettävissä olevasta ajasta sekä yksilöllisistä ominaisuuksista. Tutkimuksessa mitattiin kognitiivisen kuormituksen tasoa subjektiivisen arvioinnin menetelmällä NASA-TLX (National Aeronautics and Space Administration - Task Load Index) ja MCH (Modified Cooper-Harper) -mittareilla. Tutkimuksessa selvitettiin mittareiden havaintoarvojen muutosta, sensitiivisyyttä ja yhdenmukaisuutta kognitiivisen kuormituksen tason muuttuessa. Tutkimuksen mittauksiin osallistui 35 Suomen ilmavoimien aktiivisessa palveluksessa olevaa F/A-18-monitoimihävittäjäohjaajaa. Koehenkilöiden lentotuntien keskiarvo F/A-18-monitoimihävittäjällä oli 598 tuntia ja keskihajonta 445 tuntia. Koehenkilöiden tehtävänä oli lentää F/A-18-virtuaalisimulaattorilla 11 ILS (Instrument Landing System) -mittarilähestymistä eri aloitusetäisyyksiltä kiitotien kynnyksestä. Kognitiivisesti kuormitta-van mittarilähestymistehtävän aikana kuormituksen tasoa nostettiin lisätehtävillä ja vähentä-mällä tehtäviin käytettävissä olevaa aikaa. Koehenkilöitä pyydettiin ponnistelemaan mahdollisimman paljon tehtävien suorittamisen aikana hyvän suoritustason ylläpitämiseksi. Tulosten perusteella mittareiden havaintoarvot muuttuivat kognitiivisen kuormituksen tason muuttuessa. Käytettävissä olevan ajan vaikutus kognitiivisen kuormituksen tasoon oli tilastollisesti erittäin merkitsevä. Mittarit olivat sensitiivisiä kognitiivisen kuormituksen tason muutokselle ja antoivat yhdenmukaisia havaintoarvoja.
Resumo:
Kotkan jakelualueella käytetään historiallisista syistä keskijänniteverkossa kahta jänniteta-soa, 10 kV ja 20 kV. Eri jännitetasojen lisäksi Kotkan jakelualueen 110/20 päämuuntajien kytkentäryhmänä on käytössä YNyn0, kun taas muualla verkossa käytetään YNd11 kyt-kentäryhmää. Jännitetasoista ja kytkentäryhmistä johtuen Kotkan jakeluverkon yhteenkyt-kettävyys ympäröivän verkon kanssa on haastavaa. Työn tavoitteena on selvittää Kotkan kaupungin keskijänniteverkon nykytila ja käytettä-vyys häiriötilanteissa pahimpana mahdollisena aikana, sekä löytää mahdolliset ongelma-kohdat. Verkon nykytila tarkasteltiin verkkotietojärjestelmän avulla käyttäen laskennallisia tuloksia, jotka skaalattiin vastaamaan kovemman pakkastalven kuormitusta. Skaalaus teh-tiin useamman vuoden takaiseen tilanteeseen, jolloin yleinen taloustilanne oli parempi ja verkon kuormitus suurempi, jolloin verkko ei tule alimitoitetuksi taloustilanteen parantuessa. Tulevaisuuden varalta muodostettiin alueen tulevaisuuden kuormitusennusteet käyttämällä historiatietoja sekä tulevaisuuden näkymiä apuna. Työn keskeisimmäksi sisällöksi muodostui selvittää tarve usean käyttöjännitteen säilyttä-miselle sekä erilaisten kytkentäryhmien ylläpitämiseen ja kosketusjänniteongelman ratkai-seminen. Alueen sähköverkon kehittämiseksi tehtiin useita eri vaihtoehtoja, joita vertailtiin elinkaarikustannusperiaatteella toisiinsa. Vertailun pohjalta saatiin investointistrategia ehdo-tukset, joiden pohjalta verkkoyhtiö voi tehdä tulevaisuuteen sijoittuvia ratkaisuja.
Resumo:
The objective was to determine the glycemic index and glycemic load of tropical fruits and the potential risk for chronic diseases. Nine fruits were investigated: coconut water (for the purpose of this study, coconut water was classified as a “fruit”), guava, tamarind, passion fruit, custard apple, hog plum, cashew, sapodilla, and soursop. The GI and GL were determined according to the Food and Agriculture Organization protocol. The GL was calculated taking into consideration intake recommendation guidelines; 77.8% of the fruits had low GI although significant oscillations were observed in some graphs, which may indicate potential risks of disease. Coconut water and custard apple had a moderate GI, and all fruits had low GL. The fruits evaluated are healthy and can be consumed following the daily recommended amount. However, caution is recommended with fruits causing early glycemic peak and the fruits with moderated GI (coconut water and custard apple).
Resumo:
Effect of ultrasound treatment on carrot juice was investigated through measuring pH, electrical conductivity, viscosity, visual color, total soluble solids, total sugars, total carotenoids, ascorbic acid contents and microbial load. No significant effect (p>0.05) of ultrasound treatment on pH of carrot juice was observed. Electrical conductivity, viscosity and color values gradually increased (p<0.05) with treatment time increase. Total soluble solids, total sugars, total carotenoids and ascorbic acid contents of carrot juice were significantly improved (p<0.05) due to ultrasound treatment. Moreover, significant decrease (p<0.05) in microbial load of sonicated carrot juice was observed. Results from present study suggested that ultrasound treatment could improve quality and safety of carrot juice.