913 resultados para Load flow with step size optimization


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, rapid, selective and specific high performance liquid chromatographic (HPLC) method for quantitative analysis of the triamcinolone in polylactide-co-glycolide acid (PLGA) microparticles was developed. The chromatographic parameters were reversed-phase C18 column, 250mm x 4.6mm, with particle size 5 μm. The column oven was thermostated at 35°C ± 2°C. The mobile phase was methanol/water 45:55 (v/v) and elution was isocratic at a flow-rate of 1 mL.mL-1. The determinations were performed using a UV-Vis detector at 239 nm. The injected sample volume was 10 μL. The standard curve was linear (r2 > 0.999) in the concentration range 100-2500 ng.mL-1. The method showed adequate precision, with a relative standard deviation (RSD) was smaller than 3%. The accuracy was analyzed by adding a standard drug and good recovery values were obtained for all drug concentrations used. The method showed specificity and selectivity with linearity in the working range and good precision and accuracy, making it very suitable for quantitation of triamcinolone in PLGA microparticles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is a case report of a 39-year-old black woman, nulliparous, married who presented a heavy menstrual flow with clots and dysmenorrhea. Gynaecological examination of the uterus revealed RVF, mobility, no pain, slight enlargement, and right displacement. Magnetic resonance imaging (MRI) of the pelvis showed a 40 mm submucous fibroid with intramural component less than 50%, type 1, with a 3 mm distance from serosa. In an office hysteroscopy, it was noted a 40 mm submucous fibroid with an intramural component with less than 50%, type 1, classified in STEP-W submucous fibroids classification as a Score 6, Group II. The patient was submitted to partial hysteroscopic myomectomy, removing 60% of the fibroid volume in a 48.75-minute surgery. GnRH analogue was indicated for 3 months before another intervention. In the second evaluation MRI revealed a 22 mm-fibroid with intramural component more than 50%, type 2, with a 7 mm distance from serosa. Hysteroscopy found a 20 mm submucous fibroid, with intramural component more than 50%, type 2, Score 4, Group I on STEP-W classification. The patient was submitted to a second hysteroscopic myomectomy with complete removal and 10.5 minutes operating time, without complications. © 2006 Springer-Verlag.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is a case report of a 27-year-old white woman, nuliparous, single, who presented a heavy menstrual flow with clots, dysmenorrhoea and anaemia. Gynaecological examination of the uterus revealed anteverted position, mobility, no pain, slight enlargement and right displacement. Magnetic resonance imaging of the pelvis showed a 29-mm submucous fibroid with intramural component more than 50%, type 2, in the posterior wall, with a 5-mm distance from serosa. In office hysteroscopy, a 30-mm submucous fibroid with an intramural component with more than 50%, type 2, near around 5 mm from left tubal ostia, classified in STEP-W submucous fibroids classification as score 6, group II, was noted. GnRH analogue was indicated for 3 months before intervention to treat anaemia. The patient was submitted to hysteroscopic myomectomy with direct mobilisation technique, with the fibroid completely removed without complications in a surgery which lasted for 52 min and 20 s. © 2008 Springer-Verlag.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper deals with results of a research and development (R&D) project in cooperation with Electric Power Distribution Company in São Paulo (Brazil) regarding the development and experimental analysis of a new concept of power drive system suitable for application in traction systems of electrical vehicles pulled by electrical motors, which can be powered by urban DC or AC distribution networks. The proposed front-end structure is composed by five boost power cells in interleaving connection, operating in discontinuous conduction mode as AC-DC converter, or as DC-DC converter, in order to provide the proper DC output voltage range required by DC or AC adjustable speed drivers. Therefore, when supplied by single-phase AC distribution networks, and operating as AC-DC converter, it is capable to provide high power factor, reduced harmonic distortion in the input current, complying with the restrictions imposed by the IEC 61000-3-4 standards resulting in significant improvements for the trolleybuses systems efficiency and for the urban distribution network costs. Considering the compliance with input current restrictions imposed by IEC 61000-3-4 standards, two digital control strategies were evaluated. The digital controller has been implemented using a low cost FPGA (XC3S200) and developed totally using a hardware description language VHDL and fixed point arithmetic. Experimental results from a 15 kW low power scale prototype operating in DC and AC conditions are presented, in order to verify the feasibility and performance of the proposed system. © 2009 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, the calculation of the steady-state operation of a radial/meshed electrical distribution system (EDS) through solving a system of linear equations (non-iterative load flow) is presented. The constant power type demand of the EDS is modeled through linear approximations in terms of real and imaginary parts of the voltage taking into account the typical operating conditions of the EDS's. To illustrate the use of the proposed set of linear equations, a linear model for the optimal power flow with distributed generator is presented. Results using some test and real systems show the excellent performance of the proposed methodology when is compared with conventional methods. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In canine visceral leishmaniasis (CVL), the abnormalities most commonly observed in clinical examination on the animals are lymphadenomegaly and skin lesions. Dogs are the main domestic reservoir for the protozoon Leishmania (L.) chagasi and the skin is the main site of contamination by the vector insect. Some protozoa use apoptosis as an immunological escape mechanism. The aim of this study was to correlate the presence of apoptosis with the parasite load and with the inflammatory response in the skin and lymph nodes of dogs naturally infected with Leishmania (L.) chagasi. Thirty-three dogs from the municipality of Araçatuba (São Paulo, Brazil) were used, an endemic area for CVL. Muzzle, ear and abdominal skin and the popliteal, subscapular, iliac and mesenteric lymph nodes of symptomatic (S), oligosymptomatic (O) and asymptomatic (A) dogs were analyzed histologically. The parasite load and percentage apoptosis were evaluated using an immunohistochemical technique. Microscopically, the lymph nodes presented chronic lymphadenitis and the skin presented plasmacytic infiltrate and granulomatous foci in the superficial dermis, especially in the ear and muzzle regions. The inflammation was most severe in group S. The parasite load and apoptotic cell density were also greatest in this group. The cause of the lymphoid atrophy in these dogs was correlated with T lymphocyte apoptosis, thus leaving the dogs more susceptible to CVL. The peripheral lymph nodes presented the greatest inflammatory response. Independent of the clinical picture, the predominant inflammatory response was granulomatous and plasmacytic, both in the skin and in the peripheral lymph nodes. The ear skin presented the greatest intensity of inflammation and parasite load, followed by the muzzle skin, in group S. The ear skin area presented a non-significant difference in cell profile, with predominance of macrophages, and a significant difference from group A to groups O and S. It was seen that in these areas, there were high densities of parasites and cells undergoing apoptosis, in group S. The association between apoptosis and parasite load was not significant in the lymph nodes, but in the muzzle regions and at the ear tips, a positive correlation was seen between the parasite load and the density of cells undergoing apoptosis. The dogs in group S had the highest parasite load and the greatest number of apoptotic cells, thus suggesting that the parasite had an immune evasion mechanism, which could be proven statistically in the skin. © 2012 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An algorithm for real-time and onboard orbit determination applying the Extended Kalman Filter (EKF) method is developed. Aiming at a very simple and still fairly accurate orbit determination, an analysis is performed to ascertain an adequacy of modeling complexity versus accuracy. The minimum set of to-be-estimated states to reach the level of accuracy of tens of meters is found to have at least the position, velocity, and user clock offset components. The dynamical model is assessed through several tests, covering force model, numerical integration scheme and step size, and simplified variational equations. The measurement model includes only relevant effects to the order of meters. The EKF method is chosen to be the simplest real-time estimation algorithm with adequate tuning of its parameters. In the developed procedure, the obtained position and velocity errors along a day vary from 15 to 20 m and from 0.014 to 0.018 m/s, respectively, with standard deviation from 6 to 10 m and from 0.006 to 0.008 m/s, respectively, with the SA either on or off. The results, as well as analysis of the final adopted models used, are presented in this work. © 2013 Ana Paula Marins Chiaradia et al.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We examined the effects of meal size on the postprandial metabolic response of the lancehead Bothrops alternatus (Duméril, Bibron & Duméril, 1894), fed mice equaling to 5, 10, 20, and 40% of the snake's body mass. The maximum O2 consumption rates measured during digestion increased with meal size, reaching levels up to 2.8-7.8-fold higher than the metabolic rate measured during fasting. Specific Dynamic Action (SDA) duration also increased with meal size, lasting from 54 to 212 hours to complete. Under our experimental conditions, 30°C, the majority of our snakes failed to completely digest prey with a relative size of 40%. The SDA coefficient ranged from 17 to 27% of the energy content of the meal and was not affected by meal size. © 2013 Sociedade Brasileira de Zoologia All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper provides a contribution to the contingency analysis of electric power systems under steady state conditions. An alternative methodology is presented for static contingency analyses that only use continuation methods and thus provides an accurate determination of the loading margin. Rather than starting from the base case operating point, the proposed continuation power flow obtains the post-contingency loading margins starting from the maximum loading and using a bus voltage magnitude as a parameter. The branch selected for the contingency evaluation is parameterised using a scaling factor, which allows its gradual removal and assures the continuation power flow convergence for the cases where the method would diverge for the complete transmission line or transformer removal. The applicability and effectiveness of the proposed methodology have been investigated on IEEE test systems (14, 57 and 118 buses) and compared with the continuation power flow, which obtains the post-contingency loading margin starting from the base case solution. In general, for most of the analysed contingencies, few iterations are necessary to determine the post-contingency maximum loading point. Thus, a significant reduction in the global number of iterations is achieved. Therefore, the proposed methodology can be used as an alternative technique to verify and even to obtain the list of critical contingencies supplied by the electric power systems security analysis function. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)