997 resultados para LIQUID NORMAL-ALKANES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanotechnology plays a central role in ‘tailoring’ materials’ properties and thus improving its performances for a wide range of applications. Coupling nature nano-objects with nanotechnology results in materials with enhanced functionalities. The main objective of this master thesis was the synthesis of nanocrystalline cellulose (NCCs) and its further incorporation in a cellulosic matrix, in order to produce a stimuli-responsive material to moisture. The induced behaviour (bending/unbending) of the samples was deeply investigated, in order to determine relationships between structure/properties. Using microcrystalline cellulose as a starting material, acid hydrolysis was performed and the NCC was obtained. Anisotropic aqueous solutions of HPC and NCC were prepared and films with thicknesses ranging from 22μm to 61μm were achieved, by using a shear casting technique. Microscopic and spectroscopic techniques as well as mechanical and rheological essays were used to characterize the transparent and flexible films produced. Upon the application of a stimulus (moisture), the bending/unbending response times were measured. The use of NCC allowed obtaining films with response times in the order of 6 seconds for the bending and 5 seconds for the unbending, improving the results previously reported. These promising results open new horizons for building up improved soft steam engines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the field of energy, natural gas is an essential bridge to a clean, low carbon, renewable energy era. However, natural gas processing and transportation regulation require the removal of contaminant compounds such as carbon dioxide (CO2). Regarding clean air, the increasing atmospheric concentrations of greenhouse gases, specifically CO2, is of particular concern. Therefore, new costeffective, high performance technologies for carbon capture have been researched and the design of materials with the ability to efficiently separate CO2 from other gases is of vital importance.(...)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: Morte súbita representa a principal causa de óbito em chagásicos. Eventos fatais em pacientes saudáveis, com anormalidades contráteis, foram documentados. O objetivo deste trabalho é determinar a associação entre alteração contrátil e arritmias ventriculares complexas em pacientes chagásicos, classe funcional I, eletrocardiograma normal ou borderline e função ventricular preservada. MÉTODOS: Quarenta e nove pacientes com doença de Chagas e eletrocardiograma normal ou borderline realizaram ecocardiograma, teste ergométrico e Holter. Avaliou-se a contratilidade global e segmentar dos ventrículos e a presença de arritmias ventriculares complexas induzidas no esforço e espontâneas, respectivamente. A análise estatística foi feita pelo modelo Log-Linear geral. RESULTADOS: Idade média de 56 anos; 55% mulheres. Alterações contráteis segmentares em 24,5% dos pacientes; 12% dos Holter e 18% dos testes ergométricos positivos. Houve associação entre arritmia e alteração segmentar condicionada à presença da disfunção sistólica leve do ventrículo esquerdo. CONCLUSÕES: Alterações contráteis, na presença de disfunção global leve, indicam pacientes sob maior risco de arritmias complexas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A thermal Energy Storage Unit (ESU) could be used to attenuate inherent temperature fluctuations of a cold finger, either from a cryocooler working or due to sudden income heat bursts. An ESU directly coupled to the cold source acts as a thermal buffer temporarily increasing its cooling capacity and providing a better thermal stability of the cold finger (“Power Booster mode”). The energy storage units presented here use an enthalpy reservoir based on the high latent heat of the liquid-vapour transition of neon in the temperature range 38 - 44 K to store up to 900 J, and that uses a 6 liters expansion volume at RT in order to work as a closed system. Experimental results in the power booster mode will be described: in this case, the liquid neon cell was directly coupled to the cold finger of the working cryocooler, its volume (12 cm3) allowing it to store 450 J at around 40 K. 10 W heat bursts were applied, leading to liquid evaporation, with quite reduced temperature changes. The liquid neon reservoir can also work as a temporary cold source to be used after stopping the cryocooler, allowing for a vibration-free environment. In this case the enthalpy reservoir implemented (24 cm3) was linked to the cryocooler cold finger through a gas gap heat switch for thermal coupling/decoupling of the cold finger. We will show that, by controlling the enthalpy reservoir’s pressure, 900 J can be stored at a constant temperature of 40 K as in a triple-point ESU.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryocoolers have been progressively replacing the use of the stored cryogens in cryogenic chains used for detector cooling, thanks to their higher and higher reliability. However, the mechanical vibrations, the electromagnetic interferences and the temperature fluctuations inherent to their functioning could reduce the sensor’s sensitivity. In order to minimize this problem, compact thermal energy storage units (ESU) are studied, devices able to store thermal energy without significant temperature increase. These devices can be used as a temporary cold source making it possible to turn the cryocooler OFF providing a proper environment for the sensor. A heat switch is responsible for the thermal decoupling of the ESU from the cryocooler’s temperature that increases when turned OFF. In this work, several prototypes working around 40 K were designed, built and characterized. They consist in a low temperature cell that contains the liquid neon connected to an expansion volume at room temperature for gas storage during the liquid evaporation phase. To turn this system insensitive to the gravity direction, the liquid is retained in the low temperature cell by capillary effect in a porous material. Thanks to pressure regulation of the liquid neon bath, 900 J were stored at 40K. The higher latent heat of the liquid and the inexistence of triple point transitions at 40 K turn the pressure control during the evaporation a versatile and compact alternative to an ESU working at the triple point transitions. A quite compact second prototype ESU directly connected to the cryocooler cold finger was tested as a temperature stabilizer. This device was able to stabilize the cryocooler temperature ((≈ 40K ±1 K) despite sudden heat bursts corresponding to twice the cooling power of the cryocooler. This thesis describes the construction of these devices as well as the tests performed. It is also shown that the thermal model developed to predict the thermal behaviour of these devices, implemented as a software,describes quite well the experimental results. Solutions to improve these devices are also proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryocoolers have been progressively replacing the use of the stored cryogens in cryogenic chains used for detector cooling, thanks to their higher and higher reliability. However, the mechanical vibrations, the electromagnetic interferences and the temperature fluctuations inherent to their functioning could reduce the sensor’s sensitivity. In order to minimize this problem, compact thermal energy storage units (ESU) are studied, devices able to store thermal energy without significant temperature increase. These devices can be used as a temporary cold source making it possible to turn the cryocooler OFF providing a proper environment for the sensor. A heat switch is responsible for the thermal decoupling of the ESU from the cryocooler’s temperature that increases when turned OFF. In this work, several prototypes working around 40 K were designed, built and characterized. They consist in a low temperature cell that contains the liquid neon connected to an expansion volume at room temperature for gas storage during the liquid evaporation phase. To turn this system insensitive to the gravity direction, the liquid is retained in the low temperature cell by capillary effect in a porous material. Thanks to pressure regulation of the liquid neon bath, 900 J were stored at 40K. The higher latent heat of the liquid and the inexistence of triple point transitions at 40 K turn the pressure control during the evaporation a versatile and compact alternative to an ESU working at the triple point transitions. A quite compact second prototype ESU directly connected to the cryocooler cold finger was tested as a temperature stabilizer. This device was able to stabilize the cryocooler temperature ((≈ 40K ±1 K) despite sudden heat bursts corresponding to twice the cooling power of the cryocooler. This thesis describes the construction of these devices as well as the tests performed. It is also shown that the thermal model developed to predict the thermal behaviour of these devices,implemented as a software, describes quite well the experimental results. Solutions to improve these devices are also proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We are constantly immersed in stimuli. Upon reaching our senses, stimuli are processed within various brain systems along various pathways into the brain, and eventually turned into a percept. However, there are percepts that do not result from responses to external source stimuli. A particular case of this situation is the auditory percept known as tinnitus. Tinnitus can be seen as a task-irrelevant auditory percept, commonly reported to interfere with normal daily tasks. This is known from reports made by tinnitus sufferers that refer to their phantom percept as distracting, and that it diverts their focus from the task-relevant stimuli.(...)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Approximately 30% of hepatitis C virus (HCV) monoinfected patients present persistently normal alanine aminotransferase (ALT) levels. Most of these patients have a slow progression of liver fibrosis. Studies have demonstrated the rate of liver fibrosis progression in hepatitis C virus-human immunodeficiency virus (HCV-HIV) coinfected patients is faster than in patients infected only by HCV. Few studies have evaluated the histological features of chronic hepatitis C in HIV-infected patients with normal ALT levels. METHODS: HCV-HIV coinfected patients (HCV-RNA and anti-HIV positive) with known time of HCV infection (intravenous drugs users) were selected. Patients with hepatitis B surface antigen (HBsAg) positive or hepatitis C treatment before liver biopsy were excluded. Patients were considered to have a normal ALT levels if they had at least 3 normal determinations in the previous 6 months prior to liver biopsy. All patients were submitted to liver biopsy and METAVIR scale was used. RESULTS: Of 50 studied patients 40 (80%) were males. All patients were treated with antiretroviral therapy. The ALT levels were normal in 13 (26%) patients. HCV-HIV co-infected patients with normal ALT levels had presented means of the liver fibrosis stages (0.77±0.44 versus 1.86±1.38; p<0.001) periportal inflammatory activity (0.62±0.77 versus 2.24±1.35; p<0.001) and liver fibrosis progression rate (0.058±0.043 fibrosis unit/year versus 0.118±0.102 fibrosis unit/year) significantly lower as compared to those with elevated ALT. CONCLUSIONS: HCV-HIV coinfected patients with persistently normal ALTs showed slower progression of liver fibrosis. In these patients the development of liver cirrhosis is improbable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Snake bite, a problem in public health, generally occurs where there is no electric power. METHODS: A comparative clinical study was conducted with 102 victims of Bothrops snake bite, from the state of Amazonas, Brazil; 58 victims were treated with liofilizated trivalent antivenom serum (SATL) and 44 victims treated with liquid bivalent and monovalent antivenom serum (SAMBL). RESULTS: 17% (10/58) of patients presented adverse effects with the SATL and 25% (11/44) with the SAMBL. CONCLUSIONS: There was no statistic difference in number of adverse effects between the two types of snake bite antivenom.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Master’s Double Degree in Finance from Maastricht University and NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O estado de degradação de edifícios em Portugal tem aumentado significativamente ao longo dos últimos anos, devido, entre outros aspectos, ao envelhecimento e à falta de manutenção. Estes factores aceleram o processo de deterioração dos edifícios, motivando o aparecimento de anomalias. No entanto, existem diversas ferramentas para o levantamento dessas anomalias e para avaliação do estado de conservação de edifícios. Em 2006, foi desenvolvido no Laboratório Nacional de Engenharia Civil (LNEC), o Método de Avaliação do Estado de Conservação de imóveis (MAEC), que permite determinar, de forma expedita, o estado de conservação de edifícios, através da realização de inspecções visuais ao local por técnicos qualificados. Contudo, algumas situações que possam causar riscos na utilização corrente dos edifícios, caso não derivem de anomalias físicas construtivas, não são tomadas em consideração para efeitos de definição de intervenções de reabilitação. Considera-se importante que no momento do levantamento das condições de degradação física, a avaliação da segurança ao uso normal tenha igual relevância, através da identificação de alguns perigos. Em países como o Reino Unido e França são utilizadas metodologias de avaliação que integram em simultâneo estas duas dimensões. Neste sentido, o MAEC poderá ser complementado de forma a concretizar e a viabilizar este tipo de avaliações. Assim, o estudo visa desenvolver uma ferramenta aplicável em inspecções para avaliação das condições de segurança dos imóveis (MACS), integrando o MAEC neste processo de intervenção. Para isso analisaram-se outros métodos de avaliação (nacional e estrangeiros) que serviram de apoio ao desenvolvimento da proposta. Para testar a viabilidade do novo método foi avaliada uma amostra de imóveis no âmbito do MAEC e do MACS, através da inspecção de edifícios de uso habitacional, com épocas construtivas distintas. De uma forma geral, concluiu-se que a metodologia permitiu criar padrões actuais de risco, e a sua aplicação possibilitou a comparação das condições de segurança de diferentes edifícios. Também foi possível identificar os perigos com maior risco de ocorrência de acidentes, permitindo a definição de níveis de urgência de intervenção das situações consideradas perigosas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Hyperhomocyst(e)inaemia is an important risk factor for atherosclerosis, which is currently a major cause of death in renal transplant patients. The aim of this study was to assess the influence of immunosuppressive therapy on homocyst(e)inemia in renal transplant recipients. METHODS: Total serum homocysteine (by high performance liquid chromatography), creatinine, lipid profile, folic acid (by radioimmunoassay-RIA) and vitamin B12 (by RIA) concentrations were measured in 3 groups. Group I patients (n=20) were under treatment with cyclosporine, azathioprine, and prednisone; group II (n=9) were under treatment with azathioprine and prednisone; and group III (n=7) were composed of renal graft donors for groups I and II. Creatinine, estimated creatinine clearance, cyclosporine trough level, lipid profile, folic acid, and vitamin B12 concentrations and clinical characteristics of patients were assessed with the aim of ascertaining determinants of hyperhomocyst(e)inemia. RESULTS: Patient ages were 48.8 ± 15.1 yr (group I), 43.3 ± 11.3 yr (group II); and 46.5 ± 14.8 yr (group III). Mean serum homocyst(e)ine (tHcy) concentrations were 18.07 ± 8.29 mmol/l in renal transplant recipients; 16.55 ± 5.6 mmol/l and 21.44 ± 12.1 mmol/l respectively for group I (with cyclosporine) and group II (without cyclosporine) (NS). In renal donors, tHcy was significantly lower (9.07 ± 3.06 mmol/l; group I + group II vs. group III, p<0.008). There was an unadjusted correlation (p<0.10) between age (r=0.427; p<0.005) body weight (r=0.412; p<0.05), serum creatinine (r=0.427; p<0.05), estimated creatinine clearance (r=0.316; p<0.10), and tHcy in renal recipients (group I +II). Independent regressors (r²=0.46) identified in the multiple regression model were age (coefficient= 0.253; p=0.009) and serum creatinine (coefficient=8.07; p=0.045). We found no cases of hyperhomocyst(e)inemia in the control group. In contrast, 38% of renal recipients had hyperhomocyst(e)inemia: 7 cases (35%) on cyclosporine and 4 (45%) without cyclosporine, based on serum normal levels. CONCLUSIONS: Renal transplant recipients frequently have hyperhomocyst(e)inemia. Hyperhomocyst(e)inemia in renal transplant patients is independent of the scheme of immunosuppression they are taking. The older the patients are and the higher are their serum creatinine levels, the more susceptible they are to hyperhomocyst(e)inemia following renal transplantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone is an androgen-dependent tissue, but it is not clear whether the androgen action in bone depends on testosterone or on dihydrotestosterone. Patients with 5alpha-reductase 2 deficiency present normal levels of testosterone and low levels of dihydrotestosterone, providing an in vivo human model for the analysis of the effect of testosterone on bone. OBJECTIVE: To analyze bone mineral density in 4 adult patients with male pseudohermaphroditism due to 5alpha-reductase 2 deficiency. RESULTS: Three patients presented normal bone mineral density of the lumbar column (L1-L4) and femur neck, and the other patient presented a slight osteopenia in the lumbar column. CONCLUSION: Patients with dihydrotestosterone deficiency present normal bone mineral density, suggesting that dihydrotestosterone is not the main androgen acting in bone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Peak and trough serum concentrations of vancomycin were determined in term newborn infants with confirmed or suspected Staphylococcus sp sepsis by high performance liquid chromatography and flourescence polarization immunoassay. OBJECTIVE: To statistically compare the results of the high performance liquid chromatography and flourescence polarization immunoassay techniques for measuring serum vancomycin concentrations. METHODS: Eighteen peak and 20 trough serum samples were assayed for vancomycin concentrations using high performance liquid chromatography and flourescence polarization immunoassay from October 1995 to October 1997. RESULTS: The linear correlation coefficients for high performance liquid chromatography and flourescence polarization immunoassay were 0.27 (peak, P = 0.110) and 0.26 (trough, P = 0.1045) respectively, which were not statistically significant. CONCLUSION: There was wide variation in serum vancomycin concentrations determined by high performance liquid chromatography as compared with those determined by flourescence polarization immunoassay. There was no recognizable pattern in the variability; in an apparently random fashion, the high performance liquid chromatography measurement was sometimes substantially higher than the flourescence polarization immunoassay measurement, and at other times it was substantially lower.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cystic fibrosis is a genetic disease usually diagnosed by abnormal sweat testing. We report a case of an 18-year-old female with bronchiectasis, chronic P. aeruginosa infection, and normal sweat chloride concentrations who experienced rapid decrease of lung function and clinical deterioration despite treatment. Given the high suspicion ofcystic fibrosis, broad genotyping testing was performed, showing a compound heterozygous with deltaF508 and 3849+10kb C->T mutations, therefore confirming cystic fibrosis diagnosis. Although the sweat chloride test remains the gold standard for the diagnosis of cystic fibrosis, alternative diagnostic tests such as genotyping and electrophysiologic measurements must be performed if there is suspicion of cystic fibrosis, despite normal or borderline sweat chloride levels.