900 resultados para L., Sarah (Sarah Lucas)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report the long term outcome of the flangeless, cemented all polyethylene Exeter cup at a mean of 14.6 years (range 10-17) after operation. Of the 263 hips in 243 patients, 122 hips are still in situ, 112 patients (119 hips) have died, eighteen hips were revised, and three patients (four hips) had moved abroad and were lost to follow-up (1.5%). Radiographs demonstrated two sockets had migrated and six more had radiolucent lines in all three zones. The Kaplan Meier survivorship at 15 years with endpoint revision for all causes is 89.9% (95% CI 84.6 to 95.2%) and for aseptic cup loosening or lysis 91.7% (CI 86.6 to 96.8%). In 210 hips with a diagnosis of primary osteoarthritis survivorship for all causes is 93.2% (95% CI 88.1 to 98.3%), and for aseptic cup loosening 95.0% (CI 90.3 to 99.7%). The cemented all polyethylene Exeter cup has an excellent long-term survivorship.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim was to construct and advise on the use of a cost-per-wear model based on contact lens replacement frequency, to form an equitable basis for cost comparison. ---------- Methods: The annual cost of professional fees, contact lenses and solutions when wearing daily, two-weekly and monthly replacement contact lenses is determined in the context of the Australian market for spherical, toric and multifocal prescription types. This annual cost is divided by the number of times lenses are worn per year, resulting in a ‘cost-per-wear’. The model is presented graphically as the cost-per-wear versus the number of times lenses are worn each week for daily replacement and reusable (two-weekly and monthly replacement) lenses.---------- Results: The cost-per-wear for two-weekly and monthly replacement spherical lenses is almost identical but decreases with increasing frequency of wear. The cost-per-wear of daily replacement spherical lenses is lower than for reusable spherical lenses, when worn from one to four days per week but higher when worn six or seven days per week. The point at which the cost-per-wear is virtually the same for all three spherical lens replacement frequencies (approximately AUD$3.00) is five days of lens wear per week. A similar but upwardly displaced (higher cost) pattern is observed for toric lenses, with the cross-over point occurring between three and four days of wear per week (AUD$4.80). Multifocal lenses have the highest price, with cross-over points for daily versus two-weekly replacement lenses at between four and five days of wear per week (AUD$5.00) and for daily versus monthly replacement lenses at three days per week (AUD$5.50).---------- Conclusions: This cost-per-wear model can be used to assist practitioners and patients in making an informed decision in relation to the cost of contact lens wear as one of many considerations that must be taken into account when deciding on the most suitable lens replacement modality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The standard treatment for a non-union of the hallux metatarsophalangeal joint fusion has been to revise the fusion. Revision fusion is technically more demanding, often involving bone grafting, more substantial fixation and prolonged period of immobilization postoperatively. We present data to suggest that removal of hardware and debridement alone is an alternative treatment option. ---------- MATERIALS AND METHODS: A case note review identified patients with a symptomatic non-union after hallux metatarsophalangeal joint (MTPJ) fusion. It is our practice to offer these patients revision fusion or removal of hardware and debridement. For the seven patients that chose hardware removal and were left with a pseudarthrosis, a matched control group was selected from patients who had had successful fusions. Three outcome scores were used. Hallux valgus and dorsiflexion angles were recorded.---------- RESULTS: One hundred thirty-nine hallux MTPJ arthrodeses were carried out. Fourteen non-unions were identified. The rate of non-union in males and following previous hallux MTPJ surgery was 19% and 24%, respectively. In females undergoing a primary MTPJ fusion, the rate was 2.4%. Twelve non-union patients were reviewed at 27 months (mean). Eleven patients had elected to undergo removal of hardware and debridement. Four patients with pseudarthrosis were unhappy with the results and proceeded to either revision fusion or MTPJ replacement. Seven non-union patients, who had removal of hardware alone, had outcome scores marginally worse compared to those with successful fusions.---------- CONCLUSION: Removal of hardware alone is a reasonable option to offer as a relatively minor procedure following a failed arthrodesis of the first MTPJ. This must be accepted on the proviso that in this study four out of 11 (36%) patients proceeded to a revision first MTPJ fusion or first MTPJ replacement. We also found that the rate of non-union in primary first MTPJ fusion was significantly higher in males and those patients who had undergone previous surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Monitoring and enhancing patient compliance with peritoneal dialysis (PD) is a recurring and problematic theme in the renal literature. A growing body of literature also argues that a failure to understand the patient's perspective of compliance may be contributing to these problems. The aim of this study was to understand the concept of compliance with PD from the patient's perspective. Using the case study approach recommended by Stake (1995), five patients on PD consented to in-depth interviews that explored the meaning of compliance in the context of PD treatment and lifestyle regimens recommended by health professionals. Participants also discussed factors that influenced their choices to follow, disregard, or refine these regimens. Results indicate that health professionals acting in alignment with individual patient needs and wishes, and demonstrating an awareness of the constraints under which patients operate and the strengths they bring to their treatment, may be the most significant issues to consider with respect to definitions of PD compliance and the development of related compliance interventions. Aspects of compliance that promoted relative normality were also important to the participants in this study and tended to result in greater concordance with health professionals' advice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The pervasiveness of technology in the 21st Century has meant that adults and children live in a society where digital devices are integral to their everyday lives and participation in society. How we communicate, learn, work, entertain ourselves, and even shop is influenced by technology. Therefore, before children begin school they are potentially exposed to a range of learning opportunities mediated by digital devices. These devices include microwaves, mobile phones, computers, and console games such as Playstations® and iPods®. In Queensland preparatory classrooms and in the homes of these children, teachers and parents support and scaffold young children’s experiences, providing them with access to a range of tools that promote learning and provide entertainment. This paper examines teachers’ and parents’ perspectives and considers whether they are techno-optimists who advocate for and promote the inclusion of digital technology, or whether they are they techno-pessimists, who prefer to exclude digital devices from young children’s everyday experiences. An exploratory, single case study design was utilised to gather data from three teachers and ten parents of children in the preparatory year. Teacher data was collected through interviews and email correspondence. Parent data was collected from questionnaires and focus groups. All parents who responded to the research invitation were mothers. The results of data analysis identified a misalignment among adults’ perspectives. Teachers were identified as techno-optimists and parents were identified as techno-pessimists with further emergent themes particular to each category being established. This is concerning because both teachers and mothers influence young children’s experiences and numeracy knowledge, thus, a shared understanding and a common commitment to supporting young children’s use of technology would be beneficial. Further research must investigate fathers’ perspectives of digital devices and the beneficial and detrimental roles that a range of digital devices, tools, and entertainment gadgets play in 21st Century children’s lives.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and purpose: The appropriate fixation method for hemiarthroplasty of the hip as it relates to implant survivorship and patient mortality is a matter of ongoing debate. We examined the influence of fixation method on revision rate and mortality.----- ----- Methods: We analyzed approximately 25,000 hemiarthroplasty cases from the AOA National Joint Replacement Registry. Deaths at 1 day, 1 week, 1 month, and 1 year were compared for all patients and among subgroups based on implant type.----- ----- Results: Patients treated with cemented monoblock hemiarthroplasty had a 1.7-times higher day-1 mortality compared to uncemented monoblock components (p < 0.001). This finding was reversed by 1 week, 1 month, and 1 year after surgery (p < 0.001). Modular hemiarthroplasties did not reveal a difference in mortality between fixation methods at any time point.----- ----- Interpretation: This study shows lower (or similar) overall mortality with cemented hemiarthroplasty of the hip.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The pervasiveness of technology in the 21st Century has meant that adults and children live in a society where digital devices are integral to their everyday lives and participation in society. How we communicate, learn, work, entertain ourselves, and even shop is influenced by technology. Therefore, before children begin school they are potentially exposed to a range of learning opportunities mediated by digital devices. These devices include microwaves, mobile phones, computers, and console games such as Playstations® and iPods®. In Queensland preparatory classrooms and in the homes of these children, teachers and parents support and scaffold young children’s experiences, providing them with access to a range of tools that promote learning and provide entertainment. This paper examines teachers’ and parents’ perspectives and considers whether they are techno-optimists who advocate for and promote the inclusion of digital technology, or whether they are they techno-pessimists, who prefer to exclude digital devices from young children’s everyday experiences. An exploratory, single case study design was utilised to gather data from three teachers and ten parents of children in the preparatory year. Teacher data was collected through interviews and email correspondence. Parent data was collected from questionnaires and focus groups. All parents who responded to the research invitation were mothers. The results of data analysis identified a misalignment among adults’ perspectives. Teachers were identified as techno-optimists and parents were identified as techno-pessimists with further emergent themes particular to each category being established. This is concerning because both teachers and mothers influence young children’s experiences and numeracy knowledge, thus, a shared understanding and a common commitment to supporting young children’s use of technology would be beneficial. Further research must investigate fathers’ perspectives of digital devices and the beneficial and detrimental roles that a range of digital devices, tools, and entertainment gadgets play in 21st Century children’s lives.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Between 1987 and 1999, 540 revision total hip replacements in 487 patients were performed at our institution with the femoral impaction grafting technique with a cemented femoral stem. All patients were prospectively followed for 2-15years post-operatively with no loss to follow-up. 494 hips remained successfully in situ at an average 6.7years. The ten year survival rate was 98.0% (95% CI 96.2 to 99.8) with aseptic loosening as the endpoint and 84.2% (95% CI 78.5 to 89.9) for re-operation for any reason. Indication for surgery and the use of any kind of reinforcement significantly influenced outcome (p<0.001). This is the largest known series of revision THR with femoral impaction grafting and the results support continued use of this technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe a scaling method for templating digital radiographs using conventional acetate templates independent of template magnification without the need for a calibration marker. The mean magnification factor for the radiology department was determined (119.8%, range117%-123.4%). This fixed magnification factor was used to scale the radiographs by the method described. 32 femoral heads on postoperative THR radiographs were then measured and compared to the actual size. The mean absolute accuracy was within 0.5% of actual head size (range 0 to 3%) with a mean absolute difference of 0.16mm (range 0-1mm, SD 0.26mm). Intraclass Correlation Coefficient (ICC) showed excellent reliability for both inter and intraobserver measurements with ICC scores of 0.993 (95% CI 0.988-0.996) for interobserver measurements and intraobserver measurements ranging between 0.990-0.993 (95% CI 0.980-0.997).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and purpose: Acetabular impaction grafting has been shown to have excellent results, but concerns regarding its suitability for larger defects have been highlighted. We report the use of this technique in a large cohort of patients with the aim of better understanding the limitations of the technique. Methods: We investigated a consecutive group of 339 cases of impaction grafting of the cup with morcellised impacted allograft bone for survivorship and mechanisms for early failure. Results: Kaplan Meier survival was 89.1% (95% CI 83.2 to 95.0%) at 5.8 years for revision for any reason, and 91.6% (95% CI 85.9 to 97.3%) for revision for aseptic loosening of the cup. Of the 15 cases revised for aseptic cup loosening, nine were large rim mesh reconstructions, two were fractured Kerboull-Postel plates, two were migrating cages, one medial wall mesh failure and one impaction alone failed. Interpretation: In our series, results were disappointing where a large rim mesh or significant reconstruction was required. In light of these results, our technique has changed in that we now use predominantly larger chips of purely cancellous bone, 8-10 mm3 in size, to fill the cavity and larger diameter cups to better fill the mouth of the reconstructed acetabulum. In addition we now make greater use of i) implants made of a highly porous in-growth surface to constrain allograft chips and ii) bulk allografts combined with cages and morcellised chips in cases with very large segmental and cavitary defects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract OBJECTIVE: Depression, anxiety and alcohol misuse frequently co-occur. While there is an extensive literature reporting on the efficacy of psychological treatments that target depression, anxiety or alcohol misuse separately, less research has examined treatments that address these disorders when they co-occur. We conducted a systematic review to determine whether psychological interventions that target alcohol misuse among people with co-occurring depressive or anxiety disorders are effective. DATA SOURCES: We systematically searched the PubMed and PsychINFO databases from inception to March 2010. Individual searches in alcohol, depression and anxiety were conducted, and were limited to 'human' published 'randomized controlled trials' or 'sequential allocation' articles written in English. STUDY SELECTION: We identified randomized controlled trials that compared manual guided psychological interventions for alcohol misuse among individuals with depressive or anxiety disorders. Of 1540 articles identified, eight met inclusion criteria for the review. DATA EXTRACTION: From each study, we recorded alcohol and mental health outcomes, and other relevant clinical factors including age, gender ratio, follow-up length and drop-out rates. Quality of studies was also assessed. DATA SYNTHESIS: Motivational interviewing and cognitive-behavioral interventions were associated with significant reductions in alcohol consumption and depressive and/or anxiety symptoms. Although brief interventions were associated with significant improvements in both mental health and alcohol use variables, longer interventions produced even better outcomes. CONCLUSIONS: There is accumulating evidence for the effectiveness of motivational interviewing and cognitive behavior therapy for people with co-occurring alcohol and depressive or anxiety disorders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: This prospective study investigates the use of intraoperative fluoroscopy in 28 consecutive cases undergoing hallux valgus surgery. To our knowledge there have been no studies validating the use of intraoperative fluoroscopy in hallux valgus surgery. Methods: We performed a prospective investigation of 28 consecutive cases undergoing hallux valgus surgery. Fluoroscopic images were examined intraoperatively and any significant unforseen findings documented. A comparison was made between the fluoroscopic images and weight bearing films taken 6 weeks postoperatively to examine whether the intraoperative images are an accurate representation of the standard films obtained post-operatively. We excluded those patients that went on to have an Akin osteotomy. Results: There were no unforeseen intraoperative events that were revealed by the use of fluoroscopy and no surgical modifications were made as a result of the intraoperative images. The intraoperative films were found to be a reliable representation of the postoperative weight bearing films but a small increase in the hallux valgus angle was noted at six weeks and this is thought to be due to stretching of the medial soft tissue repair. Conclusions: Intraoperative fluoroscopy is a reliable technique. This study was performed at a centre which performs approximately 100 hallux valgus operations per year and that should be taken into consideration when reviewing our findings. We conclude that there may be a role for fluoroscopy for surgeons in the early stages of the surgical learning curve and for those that infrequently perform hallux valgus surgery. We cannot however recommend that fluoroscopy be used routinely in hallux valgus surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

NICE guidelines have stated that patients undergoing elective hip surgery are at increased risk for venous thromboembolic events (VTE) following surgery and have recommended thromboprophylaxis for 28-35 days1, 2. However the studies looking at the new direct thrombin inhibitors have only looked at major bleeding. We prospectively looked at wound discharge in patients who underwent hip arthroplasty and were given dabigatran postoperatively between March 2010 and April 2010 (n=56). We retrospectively compared these results to a matched group of patients who underwent similar operations six months earlier when all patients were given dalteparin routinely postoperatively until discharge, and discharged home on 150mg aspirin daily for 6 weeks (n=67). Wound discharge after 5 days was significantly higher in the patients taking dabigatran (32% dabigatran n=18, 10% dalteparin n=17, p=0.003) and our rate of delayed discharges due to wound discharge significantly increased from 7% in the dalteparin group (n=5) to 27% for dabigatran (n=15, p=0.004). Patients who received dabigatran were more than five times as likely to return to theatre with a wound complication as those who received dalteparin (7% dabigatran n=4, vs. 1% dalteparin n=1), however, this was not statistically significant (p=0.18). The significantly higher wound discharge and return to theatre rates demonstrated in this study have meant that we have changed our practice to administering dalteparin until the wound is dry and then starting dabigatran. Our study demonstrates the need for further clinical studies regarding wound discharge and dabigatran.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Membranes prepared from a protein, fibroin, isolated from domesticated silkworm (Bombyx mori) silk, support the cultivation of human limbal epithelial (HLE) cells and thus display significant potential as biomaterials for ocular surface reconstruction. We presently extend this promising avenue of research by directly comparing the attachment, morphology and phenotype of primary HLE cell cultures grown on fibroin to that observed on donor amniotic membrane (AM), the current clinical standard substrate for HLE transplantation. Fibroin membranes measuring 6.3 ± 0.5 μm (mean ± sd) in thickness and permeable to FITC dextran of a molecular weight up to 70 kDa, were used. Attachment of HLE cells to fibroin was similar to that supported by tissue culture plastic but approximately 6-fold less than that observed on AM. Nevertheless, epithelia constructed from HLE on fibroin maintained evidence of corneal phenotype (K3/K12 expression) and displayed a comparable number and distribution of ΔNp63+ progenitor cells to that seen in cultures grown on AM. These results support the suitability of membranes constructed from Bombyx mori silk fibroin as substrata for HLE cultivation and encourage progression to studies of efficacy in preclinical models.