890 resultados para Input bias
Resumo:
The adaptor protein-2 sigma subunit (AP2sigma;2) is pivotal for clathrin-mediated endocytosis of plasma membrane constituents such as the calcium-sensing receptor (CaSR). Mutations of the AP2sigma;2 Arg15 residue result in familial hypocalciuric hypercalcaemia type 3 (FHH3), a disorder of extracellular calcium (Ca<inf>o</inf><sup>2+</sup>) homeostasis. To elucidate the role of AP2sigma;2 in Ca<inf>o</inf><sup>2+</sup> regulation, we investigated 65 FHH probands, without other FHH-associated mutations, for AP2sigma;2 mutations, characterized their functional consequences and investigated the genetic mechanisms leading to FHH3. AP2sigma;2 mutations were identified in 17 probands, comprising 5 Arg15Cys, 4 Arg15His and 8 Arg15Leu mutations. A genotype-phenotype correlation was observed with the Arg15Leu mutation leading to marked hypercalcaemia. FHH3 probands harboured additional phenotypes such as cognitive dysfunction. All three FHH3-causing AP2sigma;2 mutations impaired CaSR signal transduction in a dominant-negative manner. Mutational bias was observed at the AP2sigma;2 Arg15 residue as other predicted missense substitutions (Arg15Gly, Arg15Pro and Arg15Ser), which also caused CaSR loss-of-function, were not detected in FHH probands, and these mutations were found to reduce the numbers of CaSR-expressing cells. FHH3 probands had significantly greater serum calcium (sCa) and magnesium (sMg) concentrations with reduced urinary calcium to creatinine clearance ratios (CCCR) in comparison with FHH1 probands with CaSR mutations, and a calculated index of sCa × sMg/100 × CCCR, which was ≥ 5.0, had a diagnostic sensitivity and specificity of 83 and 86%, respectively, for FHH3. Thus, our studies demonstrate AP2sigma;2 mutations to result in a more severe FHH phenotype with genotype-phenotype correlations, and a dominant-negative mechanism of action with mutational bias at the Arg15 residue.
Resumo:
The non-covalent incorporation of responsive luminescent lanthanide, Ln(iii), complexes with orthogonal outputs from Eu(iii) and Tb(iii) in a gel matrix allows for in situ logic operation with colorimetric outputs. Herein, we report an exemplar system with two inputs ([H(+)] and [F(-)]) within a p(HEMA-co-MMA) polymer organogel acting as a dual-responsive device and identify future potential for such systems.
Resumo:
Background and objectives: Cognitive models suggest that attentional biases are integral in the maintenance of obsessive-compulsive symptoms (OCS). Such biases have been established experimentally in anxiety disorders; however, the evidence is unclear in Obsessive Compulsive disorder (OCD). In the present study, an eye-tracking methodology was employed to explore attentional biases in relation to OCS.
Methods: A convenience sample of 85 community volunteers was assessed on OCS using the Yale-Brown Obsessive Compulsive Scale-self report. Participants completed an eye-tracking paradigm where they were exposed to OCD, Aversive and Neutral visual stimuli. Indices of attentional bias were derived from the eye-tracking data.
Results: Simple linear regressions were performed with OCS severity as the predictor and eye-tracking measures of the different attentional biases for each of the three stimuli types were the criterion variables. Findings revealed that OCS severity moderately predicted greater frequency and duration of fixations on OCD stimuli, which reflect the maintenance attentional bias. No significant results were found in support of other biases.
Limitations: Interpretations based on a non-clinical sample limit the generalisability of the conclusions, although use of such samples in OCD research has been found to be comparable to clinical populations. Future research would include both clinical and sub-clinical participants.
Conclusions: Results provide some support for the theory of maintained attention in OCD attentional biases, as opposed to vigilance theory. Individuals with greater OCS do not orient to OCD stimuli any faster than individuals with lower OCS, but once a threat is identified, these individuals allocate more attention to OCS-relevant stimuli.
Resumo:
The KongTM ball test has been used extensively to assess lateral bias in the domestic dog. Implicit in this challenge is the assumption that dogs use their dominant paw to stabilise the ball. This study examined whether or not this is the case. A comparative approach was adopted, exploring limb use in dogs and humans. In Experiment 1, the paw preference of 48 dogs was assessed on the KongTM ball test. Analysis revealed an equal distribution of paw use, although significantly more dogs were paw-preferent than ambilateral. Significantly more male dogs were classified as right-pawed, while more females were ambilateral. There was no significant effect of canine sex or castration status on the dogs’ paw preferences. In Experiment 2, 94 adult humans were assessed on their ability to remove a piece of paper from a KongTM ball with their mouth, using their left, right or both hands to stabilise the ball. 76% of the right-handed people used their left hand, and 82% of the left-handed participants used their right hand, to hold the KongTM steady. It is concluded that dogs, like humans, are most likely using their non-dominant limb to stabilise the KongTM ball and their dominant side for postural support. This has potential applied implications from an animal welfare perspective.
Resumo:
Research points to a relationship between lateralization and emotional functioning in humans and many species of animal. The present study explored the association between paw preferences and emotional functioning, specifically temperament, in a species thus far overlooked in this area, the domestic cat. Thirty left-pawed, 30 right-pawed, and 30 ambilateral pet cats were recruited following an assessment of their paw preferences using a food-reaching challenge. The animals’ temperament was subsequently assessed using the Feline Temperament Profile (FTP). Cats’ owners also completed a purpose-designed cat temperament (CAT) scale. Analysis revealed a significant relationship between lateral bias and FTP and CAT scale scores. Ambilateral cats had lower positive (FTP+) scores, and were perceived as less affectionate, obedient, friendly, and more aggressive, than left or right-pawed animals. Left and right pawed cats differed significantly on 1 trait on the CAT scale, namely playfulness. The strength of the cats’ paw preferences was related to the animals’ FTP and CAT scores. Cats with a greater strength of paw preference had higher FTP + scores than those with a weaker strength of paw preference. Animals with stronger paw preferences were perceived as more confident, affectionate, active, and friendly than those with weaker paw preferences. Results suggest that motor laterality in the cat is strongly related to temperament and that the presence or absence of lateralization has greater implications for the expression of emotion in this species than the direction of the lateralized bias.
Resumo:
Letter to the Editor
Resumo:
Several alternative approaches have been discussed: Levenberg-Marquardt - no satisfactory convergence speed + local minimum, Bacterial algorithm - problems with large dimensionality (speed), Clustering - no safe criterion for number of clusters + dimentionality problem.
Resumo:
This paper presents a new design approach for a rail-to-rail bulk-driven input stage using a standard single-well (n-well in this paper) CMOS technology. This input stage can provide nearly constant transconductance and constant slew rate over the entire input common-mode voltage, operating with a wide supply voltage ranging from sub 1-volt (V/sub T0/+ 3V/sub DSsat/) to the maximum allowed for the CMOS process, as well as preventing latch-up.
Resumo:
This paper presents a comparative study of complex single-bit and multi-bit sigma-delta modulators that are capable of providing concurrent multiple-band noise-shaping for multi-tone narrow-band input signals. The concepts applied for the three design methodologies are based on the noise transfer functions of complex comb, complex slink and complex multi-notch filters.
Resumo:
The purpose of this paper is to analyse the issues related to home bias and foreign direct investments (FDIs). We study the role of physical, cultural, and institutional distances from home on FDI decisions taken by corporations to assess whether the globalization of the past two decades has reduced their influence. Using the ‘home bias’ framework from the finance literature and the gravity model from the economics literature, we utilize a large sample of both developed and emerging markets, using FDI flows of 6263 unique bilateral country pairs over a 30-year period. We find strong empirical evidence of persistent home bias in FDI outflows, and we show that not only physical distance but also cultural and institutional similarities between host and source countries remain a decisive factor in foreign corporate investment decisions. We also show that such home bias is persistent over time and is observed around the world.
Resumo:
Job-irrelevant discrimination seems as ubiquitous as the performance appraisals in which it is commonly detected. This paper explores both compliance-based and more proactive approaches that deal with the various possible sources of discrimination in performance appraisal ratings. The suggestions lead to a code of practice for performance management in firms across cultures and national boundaries.
Resumo:
This paper presents the application of multidimensional scaling (MDS) analysis to data emerging from noninvasive lung function tests, namely the input respiratory impedance. The aim is to obtain a geometrical mapping of the diseases in a 3D space representation, allowing analysis of (dis)similarities between subjects within the same pathology groups, as well as between the various groups. The adult patient groups investigated were healthy, diagnosed chronic obstructive pulmonary disease (COPD) and diagnosed kyphoscoliosis, respectively. The children patient groups were healthy, asthma and cystic fibrosis. The results suggest that MDS can be successfully employed for mapping purposes of restrictive (kyphoscoliosis) and obstructive (COPD) pathologies. Hence, MDS tools can be further examined to define clear limits between pools of patients for clinical classification, and used as a training aid for medical traineeship.
Resumo:
In this paper we present results about the functioning of a multilayered a-SiC:H heterostructure as a device for wavelength-division demultiplexing of optical signals. The device is composed of two stacked p-i-n photodiodes, both optimized for the selective collection of photogenerated carriers. Band gap engineering was used to adjust the photogeneration and recombination rates profiles of the intrinsic absorber regions of each photodiode to short and long wavelength absorption and carrier collection in the visible spectrum. The photocurrent signal using different input optical channels was analyzed at reverse and forward bias and under steady state illumination. This photocurrent is used as an input for a demux algorithm based on the voltage controlled sensitivity of the device. The device functioning is explained with results obtained by numerical simulation of the device, which permit an insight to the internal electric configuration of the double heterojunction.These results address the explanation of the device functioning in the frequency domain to a wavelength tunable photocapacitance due to the accumulation of space charge localized at the internal junction. The existence of a direct relation between the experimentally observed capacitive effects of the double diode and the quality of the semiconductor materials used to form the internal junction is highlighted.
Resumo:
The amorphous silicon photo-sensor studied in this thesis, is a double pin structure (p(a-SiC:H)-i’(a-SiC:H)-n(a-SiC:H)-p(a-SiC:H)-i(a-Si:H)-n(a-Si:H)) sandwiched between two transparent contacts deposited over transparent glass thus with the possibility of illumination on both sides, responding to wave-lengths from the ultra-violet, visible to the near infrared range. The frontal il-lumination surface, glass side, is used for light signal inputs. Both surfaces are used for optical bias, which changes the dynamic characteristics of the photo-sensor resulting in different outputs for the same input. Experimental studies were made with the photo-sensor to evaluate its applicability in multiplexing and demultiplexing several data communication channels. The digital light sig-nal was defined to implement simple logical operations like the NOT, AND, OR, and complex like the XOR, MAJ, full-adder and memory effect. A pro-grammable pattern emission system was built and also those for the validation and recovery of the obtained signals. This photo-sensor has applications in op-tical communications with several wavelengths, as a wavelength detector and to execute directly logical operations over digital light input signals.
Resumo:
Background : In the present article, we propose an alternative method for dealing with negative affectivity (NA) biases in research, while investigating the association between a deleterious psychosocial environment at work and poor mental health. First, we investigated how strong NA must be to cause an observed correlation between the independent and dependent variables. Second, we subjectively assessed whether NA can have a large enough impact on a large enough number of subjects to invalidate the observed correlations between dependent and independent variables.Methods : We simulated 10,000 populations of 300 subjects each, using the marginal distribution of workers in an actual population that had answered the Siegrist's questionnaire on effort and reward imbalance (ERI) and the General Health Questionnaire (GHQ).Results : The results of the present study suggested that simulated NA has a minimal effect on the mean scores for effort and reward. However, the correlations between the effort and reward imbalance (ERI) ratio and the GHQ score might be important, even in simulated populations with a limited NA.Conclusions : When investigating the relationship between the ERI ratio and the GHQ score, we suggest the following rules for the interpretation of the results: correlations with an explained variance of 5% and below should be considered with caution; correlations with an explained variance between 5% and 10% may result from NA, although this effect does not seem likely; and correlations with an explained variance of 10% and above are not likely to be the result of NA biases. [Authors]