890 resultados para Immobilization devices
Resumo:
The main purpose of this work is to evaluate the failure caused by electrical discharge on commercial ZnO varistor doped with oxide of Bi, Sb, Si, Cr, Co utilized in electric transmission systems. In order to observe the effect of electrical discharge over the microstructure and electrical properties of the varistors, two kinds of pulses were applied: long pulse (2000 ms) and short pulse (8/20 mu s). In both cases, a decrease in grain size and increase in micropores and leakage current were observed. The degraded samples present oxygen defficiency mainly in the grain boundary and phase tranformation from the bismuth oxide phase. (c) 2005 Springer Science+ Business Media, Inc.
Resumo:
In this paper a modified chalcogenide glass was studied by X-ray powder diffraction, differential thermal analysis, infrared and Raman scattering spectroscopies. The study of this new matrix opens new perspectives to fabricate Pr3+-doped fibers to operate as an optical amplifier in the 1.3 mum telecommunications window. The Pr3+-doped 70Ga(2)S(3)-30La(2)S(3) glass was modified through the substitution of La2S3 by La2O3, which improves the thermal stability of these glasses without any modification of phonon energy. The possibility to pull a fiber from this glass system without any devitrification is easily achieved.
Resumo:
Natural gums have been traditionally applied in cosmetics and the food industry, mainly as emulsification agents. Due to their biodegradability and excellent mechanical properties, new technological applications have been proposed involving their use with conventional polymers forming blends and composites. In this study, we take advantage of the polyelectrolyte character exhibited by the natural gum Chicha (Sterculia striata), extracted in the Northeastern region of Brazil, to produce electroactive nanocomposites. The nanocomposites were fabricated in the form of ultrathin films by combining a metallic phthalocyanine (nickel tetrasulfonated phthalocyanine, NiTsPc) and the Chicha gum in a tetralayer architecture, in conjunction with conventional polyelectrolytes. The presence of the gum led to an efficient adsorption of the phthalocyanine and enhanced the electrochemical response of the films. Upon combining the electrochemical and UV-vis absorption data, energy diagrams of the Chicha/NiTsPc-based system were obtained. Furthermore, modified electrodes based on gum/phthalocyanine films were able to detect dopamine at concentrations as low as 10(-5) M.
Resumo:
Humic acids (HAs), naturally occurring biomacromolecules, were incorporated into nanostructured polymeric films using the layer-by-layer (LbL) technique, in which HA layers were alternated with layers of poly(allylamine hydrochloride) (PAH). Atomic force microscopy (AFM) revealed very smooth films, with mean roughness varying from 0.89 to 1.19 nm for films containing 5 and 15 PAH/HA bilayers, respectively. The films displayed electroactivity, with the presence of only one reduction peak at ca. 0.675 V (vs Ag/AgCl). Such a well-defined electroactivity allowed the films to be used as highly sensitive pesticide sensors, with detection of pentachlorophenol (PCP) in solutions at concentrations as low as 10(-9) mol L(-1).
Resumo:
In the present work, electroactive grain boundaries of highly dense metal oxide SnO2-based polycrystalline varistors were determined by electrostatic force microscopy (EFM). The EFM technique was applied to identify electroactive grain boundaries and thus estimate the amount of active grain boundary, which, in the metal oxide SnO2-based varistor, was calculated at around 85%, i.e., much higher than that found in traditional metal oxide ZnO-based varistors. The mean potential barrier height value obtained from the EFM analysis was in complete agreement with the values calculated from the C-V measurements, together with a complex capacitance plane analysis that validates the methodology proposed here. (c) 2006 American Institute of Physics.
Resumo:
The purpose of this study was to determine the accuracy of mechanical torque devices in delivering target torque values in dental offices in Salvador, Brazil. A team of researchers visited 16 dental offices, and the clinicians applied torque values (20 and 32 Ncm) to electronic torque controllers. Five repetitions were completed at each torque value and data were collected. When 20 Ncm of torque was used, 62.5% of measured values were accurate (within 10% of the target value). For 32 Ncm, however, only 37.5% of these values were achieved. Several of the tested mechanical torque devices were inaccurate. Int J Prosthodont 2011;24:38-39.
Resumo:
Background. The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to 'detect occlusal caries.Methods. The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site.Results. The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy far the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly.Conclusions. For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the Sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure.Clinical Implications. When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.
Resumo:
This work presents a case study on technology assessment for power quality improvement devices. A system compatibility test protocol for power quality mitigation devices was developed in order to evaluate the functionality of three-phase voltage restoration devices. In order to validate this test protocol, the micro-DVR, a reduced power development platform for DVR (dynamic voltage restorer) devices, was tested and the results are discussed based on voltage disturbances standards. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Bacterial cellulose (BC) membranes produced by gram-negative, acetic acid bacteria (Gluconacetobacter xylinus), were used as flexible substrates for the fabrication of Organic Light Emitting Diodes (OLED). In order to achieve the necessary conductive properties indium tin oxide (ITO) thin films were deposited onto the membrane at room temperature using radio frequency (r.f) magnetron sputtering with an r.f. power of 30 W, at pressure of 8 mPa in Ar atmosphere without any subsequent thermal treatment. Visible light transmittance of about 40% was observed. Resistivity, mobility and carrier concentration of deposited ITO films were 4.90 x 10(-4) Ohm cm, 8.08 cm(2)/V-s and -1.5 x 10(21) cm(-3), respectively, comparable with commercial ITO substrates. In order to demonstrate the feasibility of devices based on BC membranes three OLEDs with different substrates were produced: a reference one with commercial ITO on glass, a second one with a SiO(2) thin film interlayer between the BC membrane and the ITO layer and a third one just with ITO deposited directly on the BC membrane. The observed OLED luminance ratio was: 1; 0.5; 0.25 respectively, with 2400 cd/m(2) as the value for the reference OLED. These preliminary results show clearly that the functionalized biopolymer, biodegradable, biocompatible bacterial cellulose membranes can be successfully used as substrate in flexible organic optoelectronic devices. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Invertase was immobilized on aminopropyl silica (APTS-SiO2) activated with humic substances (APTS-SiO2-HS) and on aminopropyl silica activated with glutaraldehyde (APTS-SiO2-GA). The resulting activity of both systems was compared. Humic substances (HS) used for the activation of the silica were extracted from soil of Cananéia, São Paulo State, Brazil, according to the procedure recommended by the International Humic Substances Society. Activity was determined by measuring the rate of formation of reduced sugars using the reaction with dinitrosalicylic acid (DNS). The amount of HS bound on the APTS-SiO2 was equal to 50 mg. The maximum amount of invertase immobilized on APTS-SiO2-HS was 15200 U/g while in the system APTS-SiO2-GA it was 13400 U/g. The experimental enzymatic activity was 3700 and 3300 U/g, for the systems APTS-SiO2-HS and APTS-SiO2-GA, respectively. Considering the increased amount and activity of immobilized enzyme compared with the glutaraldehyde method, it was concluded that this technique opens a new perspective in the preparation of supports for enzyme immobilization employing humic substances. © Springer-Verlag 2000.
Resumo:
Catecholamines act as neurotransmitters and hormones. Studies conducted to understand the synthesis and metabolism of these monoamines during stress have been the main concern of many authors. This work proposes to investigate the time course of changes in epinephrine and norepinephrine concentration in adrenal gland obtained from rats submitted to acute immobilization stress. The results of the present study indicate that acute immobilization stress during 5 and 15min did not provoke changes in epinephrine and norepinephrine concentrations in adrenal gland in relation to the control group. Such results are justified due to the short time of the stress, showing that the stress did not provoke physiological alteration. The epinephrine and norepinephrine concentrations in adrenal gland increased significantly after the immobilization session in stressed groups during 30 and 50min as compared to control group. This increase probably is due to the emotional component of the immobilization stress. In this way, we suggested that the immobilization stress provoke increase in the biosynthesis of catecholamines in the adrenal gland from rats. However, the results shows that a maximum increase is reached at 30min of immobilization stress and then a decrement of catecholamines levels starts at 50min of the experimental design. This decline in catecholamines level may be consequence of adaptation to stress situations, an increase of the activity of the uptake systems and/or metabolization of catecholamines. In conclusion, these results suggest an effective participation of the adrenal glands to maintain the homeostasis of organism to the stressful conditions. © 2003 Elsevier Ltd. All rights reserved.