OBJECTIVETo evaluate the correlation between ultrasound-estimated bladder weight (UEBW) in patients with different degrees of bladder outlet obstruction (BOO).METHODSWe evaluated 50 consecutive non-neurogenic male patients with lower urinary tract symptoms (LUTS) referred to urodynamic study (UDS). All patients self-answered the International Prostate Score Symptoms (IPSS) questionnaire. After the UDS, the bladder was filled with 150 mL to determine UEBW.Patients with a bladder capacity under 150 mL, a previous history of prostate surgery or pelvic irradiation, an IPSS score <8, a bladder stone or urinary tract infection were excluded.After a pressure-flow study, the Schafer linear passive urethral resistance relation nomogram was plotted to determine the grade of obstruction: Grades I-II/VI were defined as mild obstruction, Grades III-IV/VI as moderate obstruction, and Grades V-VI/VI as severe obstruction.RESULTSThe UEBW was 51.7 +/- 26.9, 54.1 +/- 30.0 and 54.8 +/- 28.2 in patients with mild, moderate and severe BOO, respectively (P = 0.130). The UEBW allowed us to define four groups: (i) UEBW < 35 g; (ii) 35 g <= UEBW < 50 g; (iii) 50 g <= UEBW < 70 g; and (4) UEBW >= 70 g.We did not find any differences in age, prostate weight, IPSS, PVR, cystometric bladder capacity, presence of detrusor overactive and degree of obstruction in the aforementioned groups.CONCLUSIONDespite the fact that some studies have emphasized the value of UEBW as an efficient non-invasive method for evaluating lower urinary tract obstruction, our study suggests that UEBW does not present any individual correlation with LUTS or objective measurements of BOO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Real-time ultrasonography (RTU) was used to measure the longissimus dorsi muscle (LM) volume in vivo and to predict the carcass composition of rabbits. For this, 63 New Zealand White × Californian rabbits with 2093±63 g live weight were used. Animals were scanned between the 6th and 7th lumbar vertebrae using an RTU equipment with a 7.5 MHz probe. Measurements of LM volume were obtianed both in vivo and on carcass. Regression equations were used for the prediction of carcass composition and LM volume using the LM volume measured obtained with RTU (LMVU) as independent variable. Carcass meat, bone and total dissectible fat weights represented 780, 164 and 56 g/kg of the reference carcass weight, respectively. Regression equations showed a strong relationship between LMVU and the correspondent volume in carcass. Furthermore, LMVU was also useful in predicting the amounts of carcass tissues. It is possible to predict LM volume in the carcass using the LM volume measured in vivo by RTU. The amount of carcass tissues can be predicted by the LM volume measured in vivo by RTU.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PVC films submitted to ultrasonic irradiation presented structural changes as probed by infrared measurements. These measurements showed some infrared bands alterations attributed to the increase concentration of some conformational isomers of PVC and the presence of some new species in the macromolecular matrix. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare intrapulpal temperature increase produced by high-speed handpiece, Er:YAG laser and CVDentus ultrasound tips during cavity preparation. Thirty bovine mandibular incisors with an enamel/dentin thickness of 4 mm at buccal surface had their roots amputated and were allocated to the following groups (n=10): Group I- high-speed handpiece; Group II- noncontact Er:YAG laser (250 mJ/4Hz); and Group III- CVDentus ultrasouns tips. All devices were used with water cooling. Class V cavities were prepared to a depth of 3.5 mm, measured with a periodontal probe. A type T thermocouple was placed inside the pulp chamber to determine the temperature increase (degrees C), which was recorded by a data acquisition system ADS 2000 IP (Lynx Technology) linked to a notebook computer. Data were analyzed statistically by oneway ANOVA and Tukey's test (p=0.05). The mean temperature rises were: 1.10 degrees C ( 0.56) for Group 1, 0.84 degrees C (0.55) for Group II, and 3.00 degrees C (1.34) for Group III. There were no statistically significant differences (p > 0.05) between Groups I and II, but both of them differed significantly from Group III (p < 0.05). In conclusion, the use of Er:YAG laser and high-speed handpiece for cavity preparation resulted in similar temperature increase. Although ultrasound tips generated significantly higher intrapulpal temperature increase, it remained below the critical value of 5.5 degrees C and may be considered safe for use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the influence of dentin abrasion on the microshear bond strength of two self-etching adhesive systems, using either an ultrasound diamond bur or a high-speed diamond bur.Materials and Methods: Twenty noncarious human third molars were sectioned mesiodistally into halves. The enamel was ground to expose a flat dentin surface on both sections. The dentinal surfaces were randomly assigned to two groups, depending on the method of smear layer preparation: ultrasound diamond bur (UB) or conventional diamond bur (CB). The prepared dentin surfaces received one of two self-etching systems: Clearfil SE Bond (CF) and One-Up Bond F (OB). A composite cylinder with a 0.95-mm diameter was bonded to each specimen and the microshear bond test was performed. The results were expressed in MPa and were subjected to two-way analysis of variance (ANOVA) and Tukey's test (alpha = 0.05).Results: There was no significant difference in dentin bond strength when comparing the conventional and ultrasonic abrasion methods. When the adhesive systems were compared, Clearfil SE Bond achieved higher bond strength means than did One-Up Bond F.Conclusion: The dentin surface preparation method did not influence the microshear bond strength and the Clearfil SE Bond adhesive system, independent of bur type used, Clearfil SE Bond showed higher bond strengths than did the One-Up Bond F adhesive system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound effects on the release and activity of invertase from Aspergillus niger cultivated in a medium containing sucrose and peptone and in another with sugar-cane molasses and peptone were investigated. Irradiation was conducted for periods of 2 - 10 min. with waves of amplitude 20 and 40 using an ultrasound processor of 20 kHz. Product formation was determined as reducing equivalents formed by time units using 3,5-dinitrosalicylic acid. Total and specific activities of the culture supernatants were compared in the presence and absence of sonication. Both amplitudes promoted a significant increase of total invertase activity in the time periods investigated and the highest values were obtained with an amplitude of 20. Ultrasound irradiation caused cell disruption, thus releasing invertase and, after 4 min, activation of the enzyme also occurred. The best conditions for production, extraction and activation of invertase were in molasses medium containing peptone and irradiation with ultrasound waves at 20 for 8 min. This method showed high efficiency for the extraction and activation of invertase from A. niger as well as a great potential for use in industrial processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A paca é um roedor sul-americano cujo manejo, tranqüilização ou anestesia oferece um grande campo de pesquisa devido aos poucos artigos existentes. Doze pacas fêmeas adultas foram utilizadas, mantidas separadas em seis baias, sendo capturadas com um puçá de polipropileno e levadas a uma sala na qual se realizava a tricotomia abdominal. Após, os animais eram colocados em uma gaiola de ferro de compressão lateral. A sessão de ultra-sonografia era realizada em modo B com um transdutor setorial eletrônico de 5,0 e 7,5 MHz. Para a diminuição do estresse causado pelos procedimentos, a tranqüilização das fêmeas era realizada com diazepam e maleato de midazolam por via oral. Ambos demonstraram-se efetivos na tranqüilização das pacas previamente e durante as sessões, sendo que o maleato de midazolam proporcionou um melhor manejo dos animais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple calorimetric method was employed to study the kinetics of the hydrolysis of the solventless TMOS-water mixtures, under ultrasound stimulation, as a function of the concentration of oxalic acid. The reaction rates were obtained, in relative units, from the measured thermal peak of the reaction as a non-separated function of both the sonication time and the instantaneous temperature of the medium. For concentrations of oxalic acid below 0.01 M, polycondensation reaction starts before complete hydrolysis. For concentrations of oxalic acid above 0.01 M, hydrolysis is complete and, in addition, the inverse of the time, as measured from the starting of ultrasound action until the maximum hydrolysis heat release, was found to be a reasonable relative measure of the average hydrolysis rate constant. The average hydrolysis rate constant was found to be proportional to the square root of the molar concentration of the oxalic acid. This result is in agreement with the literature if we assume small dissociation degree for the catalyst in such a solventless alkoxyde-water medium.