962 resultados para IMPLANTED LINBO3


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Deep brain stimulation (DBS) is recognized as an effective treatment for movement disorders. We recently changed our technique, limiting the number of brain penetrations to three per side. OBJECTIVES: The first aim was to evaluate the electrode precision on both sides of surgery since we implemented this surgical technique. The second aim was to analyse whether or not the electrode placement was improved with microrecording and macrostimulation. METHODS: We retrospectively reviewed operation protocols and MRIs of 30 patients who underwent bilateral DBS. For microrecording and macrostimulation, we used three parallel channels of the 'Ben Gun' centred on the MRI-planned target. Pre- and post-operative MRIs were merged. The distance between the planned target and the centre of the implanted electrode artefact was measured. RESULTS: There was no significant difference in targeting precision on both sides of surgery. There was more intra-operative adjustment of the second electrode positioning based on microrecording and macrostimulation, which allowed to significantly approach the MRI-planned target on the medial-lateral axis. CONCLUSION: There was more electrode adjustment needed on the second side, possibly in relation with brain shift. We thus suggest performing a single central track with electrophysiological and clinical assessment, with multidirectional exploration on demand for suboptimal clinical responses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In vitro differentiation of mesenchymal stromal cells (MSC) into osteocytes (human differentiated osteogenic cells, hDOC) before implantation has been proposed to optimize bone regeneration. However, a deep characterization of the immunological properties of DOC, including their effect on dendritic cell (DC) function, is not available. DOC can be used either as cellular suspension (detached, Det-DOC) or as adherent cells implanted on scaffolds (adherent, Adh-DOC). By mimicking in vitro these two different routes of administration, we show that both Det-DOC and Adh-DOC can modulate DC functions. Specifically, the weak downregulation of CD80 and CD86 caused by Det-DOC on DC surface results in a weak modulation of DC functions, which indeed retain a high capacity to induce T-cell proliferation and to generate CD4(+)CD25(+)Foxp3(+) T cells. Moreover, Det-DOC enhance the DC capacity to differentiate CD4(+)CD161(+)CD196(+) Th17-cells by upregulating IL-6 secretion. Conversely, Adh-DOC strongly suppress DC functions by a profound downregulation of CD80 and CD86 on DC as well as by the inhibition of TGF-β production. In conclusion, we demonstrate that different types of DOC cell preparation may have a different impact on the modulation of the host immune system. This finding may have relevant implications for the design of cell-based tissue-engineering strategies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: Repair of the right ventricular outflow tract (RVOT) in paediatric cardiac surgery remains challenging due to the high reoperation rate. Intimal hyperplasia and consequent arteriosclerosis is one of the most important limitation factors for graft durability. Since local shear stress and pressure are predictive elements for intimal hyperplasia and wall degeneration, we sought to determine in an oversized 12-mm RVOT model, with computed fluid dynamics simulation, the local haemodynamical factors that may explain intimal hyperplasia. This was done with the aim of identifying the optimal degree of oversizing for a 12-mm native RVOT. METHODS: Twenty domestic pigs, with a weight of 24.6 ± 0.89 kg and a native RVOT diameter of 12 ± 1.7 mm, had valve conduits of 12, 16, 18 and 20 mm implanted. Pressure and flow were measured at 75, 100 and 125% of normal flow at RVOT at the pulmonary artery, pulmonary artery bifurcation and at the left and right pulmonary arteries. Three-dimensional computed fluid dynamics (CFD) simulation in all four geometries in all flow modalities was performed. Local shear stress and pressure conditions were investigated. RESULTS: Corresponding to 75, 100 and 125% of steady-state flow, three inlet velocity profiles were obtained, 0.2, 0.29 and 0.36 m/s, respectively. At inflow velocity profiles, low shear stress areas, ranged from 0 to 2 Pa, combined with high-pressure areas ranging from 11.5 to 12.1 mmHg that were found at distal anastomosis, at bifurcation and at the ostia of the left and right pulmonary arteries in all geometries. CONCLUSIONS: In all three oversized geometries, the local reparation of shear stress and pressure in the 16-mm model showed a similar local profile as in the native 12 mm RVOT. According to these findings, we suggest oversizing the natural 12-mm RVOT by not more than 4 mm. The elements responsible for wall degeneration and intimal hyperplasia remain very similar to the conditions present in native RVOT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Blood pressure (BP) is known to aggregate in families. Yet, heritability estimates are population-specific and no Swiss data have been published so far. We estimated the heritability of ambulatory and office BP in a Swiss population-based sample. METHODS: The Swiss Kidney Project on Genes in Hypertension is a population-based family study focusing on BP genetics. Office and ambulatory BP were measured in 1009 individuals from 271 nuclear families. Heritability was estimated for SBP, DBP, and pulse pressure using a maximum likelihood method implanted in the Statistical Analysis in Genetic Epidemiology software. RESULTS: The 518 women and 491 men included in this analysis had a mean (±SD) age of 48.3 (±17.4) and 47.3 (±17.7) years, and a mean BMI of 23.8 (±4.2) and 25.9 (±4.1) kg/m, respectively. Narrow-sense heritability estimates (±standard error) for ambulatory SBP, DBP, and pulse pressure were 0.37 ± 0.07, 0.26 ± 0.07, and 0.29 ± 0.07 for 24-h BP; 0.39 ± 0.07, 0.28 ± 0.07, and 0.27 ± 0.07 for day BP; and 0.25 ± 0.07, 0.20 ± 0.07, and 0.30 ± 0.07 for night BP, respectively (all P < 0.001). Heritability estimates for office SBP, DBP, and pulse pressure were 0.21 ± 0.08, 0.25 ± 0.08, and 0.18 ± 0.07 (all P < 0.01). CONCLUSIONS: We found significant heritability estimates for both ambulatory and office BP in this Swiss population-based study. Our findings justify the ongoing search for the genetic determinants of BP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360º, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water-based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verifica tion in a more relevant phantom is required in order to foresee the real potential of this approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Recently, it has been suggested that the type of stent used in primary percutaneous coronary interventions (pPCI) might impact upon the outcomes of patients with acute myocardial infarction (AMI). Indeed, drug-eluting stents (DES) reduce neointimal hyperplasia compared to bare-metal stents (BMS). Moreover, the later generation DES, due to its biocompatible polymer coatings and stent design, allows for greater deliverability, improved endothelial healing and therefore less restenosis and thrombus generation. However, data on the safety and performance of DES in large cohorts of AMI is still limited. AIM: To compare the early outcome of DES vs. BMS in AMI patients. METHODS: This was a prospective, multicentre analysis containing patients from 64 hospitals in Switzerland with AMI undergoing pPCI between 2005 and 2013. The primary endpoint was in-hospital all-cause death, whereas the secondary endpoint included a composite measure of major adverse cardiac and cerebrovascular events (MACCE) of death, reinfarction, and cerebrovascular event. RESULTS: Of 20,464 patients with a primary diagnosis of AMI and enrolled to the AMIS Plus registry, 15,026 were referred for pPCI and 13,442 received stent implantation. 10,094 patients were implanted with DES and 2,260 with BMS. The overall in-hospital mortality was significantly lower in patients with DES compared to those with BMS implantation (2.6% vs. 7.1%,p < 0.001). The overall in-hospital MACCE after DES was similarly lower compared to BMS (3.5% vs. 7.6%, p < 0.001). After adjusting for all confounding covariables, DES remained an independent predictor for lower in-hospital mortality (OR 0.51,95% CI 0.40-0.67, p < 0.001). Since groups differed as regards to baseline characteristics and pharmacological treatment, we performed a propensity score matching (PSM) to limit potential biases. Even after the PSM, DES implantation remained independently associated with a reduced risk of in-hospital mortality (adjusted OR 0.54, 95% CI 0.39-0.76, p < 0.001). CONCLUSIONS: In unselected patients from a nationwide, real-world cohort, we found DES, compared to BMS, was associated with lower in-hospital mortality and MACCE. The identification of optimal treatment strategies of patients with AMI needs further randomised evaluation; however, our findings suggest a potential benefit with DES.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since the first implantation of an endograft in 1991, endovascular aneurysm repair (EVAR) rapidly gained recognition. Historical trials showed lower early mortality rates but these results were not maintained beyond 4 years. Despite newer-generation devices, higher rates of reintervention are associated with EVAR during follow-up. Therefore, the best therapeutic decision relies on many parameters that the physician has to take in consideration. Patient's preferences and characteristics are important, especially age and life expectancy besides health status. Aneurysmal anatomical conditions remain probably the most predictive factor that should be carefully evaluated to offer the best treatment. Unfavorable anatomy has been observed to be associated with more complications especially endoleak, leading to more re-interventions and higher risk of late mortality. Nevertheless, technological advances have made surgeons move forward beyond the set barriers. Thus, more endografts are implanted outside the instructions for use despite excellent results after open repair especially in low-risk patients. When debating about AAA repair, some other crucial points should be analysed. It has been shown that strict surveillance is mandatory after EVAR to offer durable results and prevent late rupture. Such program is associated with additional costs and with increased risk of radiation. Moreover, a risk of loss of renal function exists when repetitive imaging and secondary procedures are required. The aim of this article is to review the data associated with abdominal aortic aneurysm and its treatment in order to establish selection criteria to decide between open or endovascular repair.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The primary end points of this study were safety and efficacy of early cannulation of the Flixene graft (Maquet-Atrium Medical, Hudson, NH). Secondary end points were complications and patency. METHODS: This is a prospective single-center nonrandomized study. Study data included patient characteristics; history of vascular access; operative technique; interval between implantation and initial cannulation; complications; and patency at 1 month, 3 months, and every 6 months. Patency rates were estimated by the Kaplan-Meier method. RESULTS: Between January 2011 and September 2013, a total of 46 Flixene grafts were implanted in 44 patients (27 men) with a mean age of 63 years. The implantation site was the upper arm in 67% of cases, the forearm in 11%, and the thigh in 22%. Seven grafts were never cannulated during the study period. Of the remaining 39 grafts, 32 (82%) were successfully cannulated within the first week after implantation, including 16 (41%) on the first day. The median interval from implantation to initial cannulation was 2 days (interquartile range, 1-3 days). The median follow-up was 223.5 days (interquartile range, 97-600 days). Five hematomas occurred, but only one required surgical revision. Primary assisted and secondary patency rates were 65% and 86%, respectively, at 6 months and 56% and 86%, respectively, at 1 year. CONCLUSIONS: This study suggests that cannulation of the Flixene graft within 1 week after implantation is safe and effective. Early cannulation avoids or shortens the need for a temporary catheter. One-year patency rates appeared to be comparable to those achieved with conventional grafts, but long-term follow-up and randomized controlled studies will be needed to confirm this finding.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: Transapical transcatheter valve procedures are performed through a left minithoracotomy and require apical sutures to seal the apical access site. The use of large-calibre devices compromises any attempt to fully perform the procedure with a thoracoscopic approach or percutaneously. We report our preliminary experience in animals with a new sutureless self-expandable apical occluder, engineered to perform transapical access site closure in a minimally invasive setting with large-size introducer sheaths. METHODS: The apical occluder with extendable waist was implanted in six young pigs during an acute animal study. Under general anaesthesia, animals (mean weight: 62 ± 8 kg) received full heparinization (heparin: 100 UI/kg; activated clotting time above 250 s). Through a median sternotomy, a 21-Fr Certitude? introducer sheath (outer diameter: 25 Fr) was placed over the wire into the cardiac apex. The delivery catheter carrying the constrained apical plug was inserted into the sheath and deployed under fluoroscopic control, whereas the Certitude? was retrieved. After protamine infusion, we observed and recorded the 1-h bleeding with standard haemodynamic parameters. Animals were sacrificed, and hearts analysed. RESULTS: Six apical closure devices were successfully introduced and deployed in six pig hearts through large-size apical sheaths at first attempt. In all animals, the plugs guaranteed immediate apical sealing and traces of blood were collected in the pericardium during the 1-h observational period (mean of 16 ± 3.4 ml of blood loss per animal). Haemodynamic parameters remained stable during the entire study period and no plug dislodgement was detected with normal systemic blood pressure (mean arterial mean blood pressure: 65 ± 7 mmHg). Post-mortem analysis confirmed the full deployment and good fixation of all plugs, without macroscopic damages to the surrounding myocardium. CONCLUSIONS: This sutureless self-expandable apical occluder is a simple device capable of sealing large-size apical access sites (20-35 Fr) in an acute animal study. This approach is a step further towards less invasive transapical valve procedures in the clinical setting, and further animal tests will be performed to confirm the long-term efficacy and safety of this device.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Prosthetic joint replacement is one of the most successful surgical procedures of the last century and the number of implanted artificial joints is rapidly growing. While the result of the procedure is generally positive, infections may occur leading to patient suffering, surgeon's frustration and important costs to the health system. Infection after prosthetic joint replacement is thus a feared complication as healing rates can be low, functional result poor and satisfaction of the patient abysmal. However, if a patient-adapted treatment of infected total joints is used, an overall success rate of above 90 % can be obtained. The patient-adapted treatment concept is based on five strong pillars: teamwork, understanding biofilm, proper diagnostics, proper definition and classification and patient-tailored treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hip joint replacement is 1 of the most successful surgical procedures of the last century and the number of replacements implanted is steadily growing. An infected hip arthroplasty is a disaster, it leads to patient suffering, surgeon's frustration and significant costs to the health system. The treatment of an infected hip replacement is challenging, healing rates can be low, functional results poor with decreased patient satisfaction. However, if a patient-adapted treatment of infected hip joints is used a success rate of above 90% can be obtained.Patient-adapted treatment is based on 5 important concepts: teamwork; understanding the biofilm; diagnostic accuracy; correct definition and classification of PJI; and patient-tailored treatment.This review presents a patient-adapted treatment strategy to prosthetic hip infection. It incorporates the best aspects of the single and staged surgical strategies and promotes the short interval philosophy for the 2-stage approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Concomitant aortic and mitral valve replacement or concomitant aortic valve replacement and mitral repair can be a challenge for the cardiac surgeon: in particular, because of their structure and design, two bioprosthetic heart valves or an aortic valve prosthesis and a rigid mitral ring can interfere at the level of the mitroaortic junction. Therefore, when a mitral bioprosthesis or a rigid mitral ring is already in place and a surgical aortic valve replacement becomes necessary, or when older high-risk patients require concomitant mitral and aortic procedures, the new 'fast-implantable' aortic valve system (Intuity valve, Edwards Lifesciences, Irvine, CA, USA) can represent a smart alternative to standard aortic bioprosthesis. Unfortunately, this is still controversial (risk of interference). However, transcatheter aortic valve replacements have been performed in patients with previously implanted mitral valves or mitral rings. Interestingly, we learned that there is no interference (or not significant interference) among the standard valve and the stent valve. Consequently, we can assume that a fast-implantable valve can also be safely placed next to a biological mitral valve or next to a rigid mitral ring without risks of distortion, malpositioning, high gradient or paravalvular leak. This paper describes two cases: a concomitant Intuity aortic valve and bioprosthetic mitral valve implantation and a concomitant Intuity aortic valve and mitral ring implantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: The treatment of Candida implant-associated infections remains challenging. We investigated the antifungal activity against planktonic and biofilm Candida albicans in a foreign-body infection model. METHODS: Teflon cages were subcutaneously implanted in guinea pigs, infected with C. albicans (ATCC 90028). Animals were treated intraperitoneally 12 h after infection for 4 days once daily with saline, fluconazole (16 mg/kg), amphotericin B (2.5 mg/kg), caspofungin (2.5 mg/kg) or anidulafungin (20 mg/kg). Planktonic Candida was quantified, the clearance rate and cure rate determined. RESULTS: In untreated animals, planktonic Candida was cleared from cage fluid in 25% (infected with 4.5 × 10(3) CFU/cage), 8% (infected with 4.8 × 10(4) CFU/cage) and 0% (infected with 6.2 × 10(5) CFU/cage). Candida biofilm persisted on all explanted cages. Compared to untreated controls, caspofungin reduced the number of planktonic C. albicans to 0.22 and 0.0 CFU/ml, respectively, and anidulafungin to 0.11 and 0.13 CFU/ml, respectively. Fluconazole cured 2/12 cages (17%), amphotericin B and anidulafungin 1/12 cages (8%) and caspofungin 3/12 cages (25%). CONCLUSION: Echinocandins showed superior activity against planktonic C. albicans. Caspofungin showed the highest cure rate of C. albicans biofilm. However, no antifungal exceeded 25% cure rate, demonstrating the difficulty of eradicating Candida biofilms from implants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patients with chronic heart failure who are not eligible for heart transplant and whose life expectancy depends mainly on the heart disease may benefit from mechanical circulatory support. Mechanical circulatory support restores adequate cardiac output and organ perfusion and eventually improves patients' clinical condition, quality of life and life expectancy. This treatment is called destination therapy (DT) and we estimate that in Switzerland more than 120 patients per year could benefit from it. In the last 10 years, design of the devices, implantation techniques and prognoses have changed dramatically. The key to successful therapy with a left ventricular assist device is appropriate patient selection, although we are still working on the definition of reliable inclusion and exclusion criteria and optimal timing for surgical implantation. Devices providing best long-term results are continuous flow, rotary or axial blood pumps implanted using minimally invasive techniques on a beating heart. These new devices (Thoratec HeartMate II and HeartWare HVAD) have only a single moving part, and have improved durability with virtually 10 years freedom from mechanical failure. In selected patients, the overall actuarial survival of DT patients is 75% at 1 year and 62% at 2 years, with a clear improvement in quality of life compared with medical management only. Complications include bleeding and infections; their overall incidence is significantly lower than with previous devices and their management is well defined. DT is evolving into an effective and reasonably cost-effective treatment option for a growing population of patients not eligible for heart transplant, showing encouraging survival rates at 2 years and providing clear improvement in quality of life. The future is bright for people suffering from chronic heart failure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

High-dose carbon-ion-implanted Si samples have been analyzed by infrared spectroscopy, Raman scattering, and x-ray photoelectron spectroscopy (XPS) correlated with transmission electron microscopy. Samples were implanted at room temperature and 500°C with doses between 1017 and 1018 C+/cm2. Some of the samples were implanted at room temperature with the surface covered by a capping oxide layer. Implanting at room temperature leads to the formation of a surface carbon-rich amorphous layer, in addition to the buried implanted layer. The dependence of this layer on the capping oxide suggests this layer to be determined by carbon migration toward the surface, rather than surface contamination. Implanting at 500°C, no carbon-rich surface layer is observed and the SiC buried layer is formed by crystalline ßSiC precipitates aligned with the Si matrix. The concentration of SiC in this region as measured by XPS is higher than for the room-temperature implantation.