979 resultados para Forced Swim
Resumo:
Purpose: To compare image quality and effective dose when the 10 kVp rule is applied with manual and AEC mode in PA chest X-ray. Methods and Materials: A total of 68 images (with and without lesions) were acquired of an anthropomorphic chest phantom in a Wolverson Arcoma X-ray unit. The images were evaluated against a reference image using image quality criteria and the 2 alternative forced choice (2 AFC) method by five radiographers. The effective dose was calculated using PCXMC software using the exposure parameters and DAP. The exposure index (lgM) was recorded. Results: Exposure time decreases considerably when applying the 10 kVp rule in manual mode (50%-28%) compared to AEC mode (36%-23%). Statistical differences for effective dose between several AEC modes were found (p=0.002). The effective dose is lower when using only the right AEC ionization chamber. Considering image quality, there are no statistical differences (p=0.348) between the different AEC modes for images with no lesions. Using a higher kVp value the lgM values will also increase. The lgM values showed significant statistical differences (p=0.000). The image quality scores did not present statistically significant differences (p=0.043) for the images with lesions when comparing manual with AEC modes. Conclusion: In general, the dose is lower in the manual mode. By using the right AEC ionising chamber the effective dose will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the detectability of the lesions.
Resumo:
OBJECTIVE To describe the health status and access to care of forced-return Mexican migrants deported through the Mexico-United States border and to compare it with the situation of voluntary-return migrants. METHODS Secondary data analysis from the Survey on Migration in Mexico’s Northern Border from 2012. This is a continuous survey, designed to describe migration flows between Mexico and the United States, with a mobile-population sampling design. We analyzed indicators of health and access to care among deported migrants, and compare them with voluntary-return migrants. Our analysis sample included 2,680 voluntary-return migrants, and 6,862 deportees. We employ an ordinal multiple logistic regression model, to compare the adjusted odds of having worst self-reported health between the studied groups. RESULTS As compared to voluntary-return migrants, deportees were less likely to have medical insurance in the United States (OR = 0.05; 95%CI 0.04;0.06). In the regression model a poorer self-perceived health was found to be associated with having been deported (OR = 1.71, 95%CI 1.52;1.92), as well as age (OR = 1.03, 95%CI 1.02;1.03) and years of education (OR = 0.94 95%CI 0.93;0.95). CONCLUSIONS According to our results, deportees had less access to care while in the United States, as compared with voluntary-return migrants. Our results also showed an independent and statistically significant association between deportation and having poorer self-perceived health. To promote the health and access to care of deported Mexican migrants coming back from the United States, new health and social policies are required.
Resumo:
The self similar branching arrangement of the airways makes the respiratory system an ideal candidate for the application of fractional calculus theory. The fractal geometry is typically characterized by a recurrent structure. This study investigates the identification of a model for the respiratory tree by means of its electrical equivalent based on intrinsic morphology. Measurements were obtained from seven volunteers, in terms of their respiratory impedance by means of its complex representation for frequencies below 5 Hz. A parametric modeling is then applied to the complex valued data points. Since at low-frequency range the inertance is negligible, each airway branch is modeled by using gamma cell resistance and capacitance, the latter having a fractional-order constant phase element (CPE), which is identified from measurements. In addition, the complex impedance is also approximated by means of a model consisting of a lumped series resistance and a lumped fractional-order capacitance. The results reveal that both models characterize the data well, whereas the averaged CPE values are supraunitary and subunitary for the ladder network and the lumped model, respectively.
Resumo:
This contribution presents novel concepts for analysis of pressure–volume curves, which offer information about the time domain dynamics of the respiratory system. The aim is to verify whether a mapping of the respiratory diseases can be obtained, allowing analysis of (dis)similarities between the dynamical pattern in the breathing in children. The groups investigated here are children, diagnosed as healthy, asthmatic, and cystic fibrosis. The pressure–volume curves have been measured by means of the noninvasive forced oscillation technique during breathing at rest. The geometrical fractal dimension is extracted from the pressure–volume curves and a power-law behavior is observed in the data. The power-law model coefficients are identified from the three sets and the results show that significant differences are present between the groups. This conclusion supports the idea that the respiratory system changes with disease in terms of airway geometry, tissue parameters, leading in turn to variations in the fractal dimension of the respiratory tree and its dynamics.
Resumo:
Purpose: To investigate whether standard X-ray acquisition factors for orbital radiographs are suitable for the detection of ferromagnetic intra-ocular foreign bodies in patients undergoing MRI. Method: 35 observers, at varied levels of education in radiography, attending a European Dose Optimisation EURASMUS Summer School were asked to score 24 images of varying acquisition factors against a clinical standard (reference image) using two alternative forced choice. The observers were provided with 12 questions and a 5 point Likert scale. Statistical tests were used to validate the scale, and scale reliability was also measured. The images which scored equal to, or better than, the reference image (36) were ranked alongside their corresponding effective dose (E), the image with the lowest dose equal to or better than the reference is considered the new optimum acquisition factors. Results: Four images emerged as equal to, or better than, the reference in terms of image quality. The images were then ranked in order of E. Only one image that scored the same as the reference had a lower dose. The reference image had a mean E of 3.31μSv, the image that scored the same had an E of 1.8μSv. Conclusion: Against the current clinical standard exposure factors of 70kVp, 20mAs and the use of an anti- scatter grid, one image proved to have a lower E whilst maintaining the same level of image quality and lesion visibility. It is suggested that the new exposure factors should be 60kVp, 20mAs and still include the use of an anti-scatter grid.
Resumo:
Purpose: To determine whether using different combinations of kVp and mAs with additional filtration can reduce the effective dose to a paediatric phantom whilst maintaining diagnostic image quality. Methods: 27 images of a paediatric AP pelvis phantom were acquired with different kVp, mAs and additional copper filtration. Images were displayed on quality controlled monitors with dimmed lighting. Ten diagnostic radiographers (5 students and 5 experienced radiographers) had eye tests to assess visual acuity before rating the images. Each image was rated for visual image quality against a reference image using 2 alternative forced choice software using a 5-point Likert scale. Physical measures (SNR and CNR) were also taken to assess image quality. Results: Of the 27 images rated, 13 of them were of acceptable image quality and had a dose lower than the image with standard acquisition parameters. Two were produced without filtration, 6 with 0.1mm and 5 with 0.2mm copper filtration. Statistical analysis found that the inter-rater and intra-rater reliability was high. Discussion: It is possible to obtain an image of acceptable image quality with a dose that is lower than published guidelines. There are some areas of the study that could be improved. These include using a wider range of kVp and mAs to give an exact set of parameters to use. Conclusion: Additional filtration has been identified as amajor tool for reducing effective dose whilst maintaining acceptable image quality in a 5 year old phantom.
Resumo:
A new data set of daily gridded observations of precipitation, computed from over 400 stations in Portugal, is used to assess the performance of 12 regional climate models at 25 km resolution, from the ENSEMBLES set, all forced by ERA-40 boundary conditions, for the 1961-2000 period. Standard point error statistics, calculated from grid point and basin aggregated data, and precipitation related climate indices are used to analyze the performance of the different models in representing the main spatial and temporal features of the regional climate, and its extreme events. As a whole, the ENSEMBLES models are found to achieve a good representation of those features, with good spatial correlations with observations. There is a small but relevant negative bias in precipitation, especially in the driest months, leading to systematic errors in related climate indices. The underprediction of precipitation occurs in most percentiles, although this deficiency is partially corrected at the basin level. Interestingly, some of the conclusions concerning the performance of the models are different of what has been found for the contiguous territory of Spain; in particular, ENSEMBLES models appear too dry over Portugal and too wet over Spain. Finally, models behave quite differently in the simulation of some important aspects of local climate, from the mean climatology to high precipitation regimes in localized mountain ranges and in the subsequent drier regions.
Resumo:
Balanced nesting is the most usual form of nesting and originates, when used singly or with crossing of such sub-models, orthogonal models. In balanced nesting we are forced to divide repeatedly the plots and we have few degrees of freedom for the first levels. If we apply stair nesting we will have plots all of the same size rendering the designs easier to apply. The stair nested designs are a valid alternative for the balanced nested designs because we can work with fewer observations, the amount of information for the different factors is more evenly distributed and we obtain good results. The inference for models with balanced nesting is already well studied. For models with stair nesting it is easy to carry out inference because it is very similar to that for balanced nesting. Furthermore stair nested designs being unbalanced have an orthogonal structure. Other alternative to the balanced nesting is the staggered nesting that is the most popular unbalanced nested design which also has the advantage of requiring fewer observations. However staggered nested designs are not orthogonal, unlike the stair nested designs. In this work we start with the algebraic structure of the balanced, the stair and the staggered nested designs and we finish with the structure of the cross between balanced and stair nested designs.
Resumo:
Dissertação apresentada à Escola Superior de Educação de Lisboa para obtenção de grau de mestre em Ciências da Educação, especialidade Supervisão em Educação
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Estruturas
Resumo:
Relatório de estágio apresentado à Escola Superior de Educação de Lisboa para obtenção de grau de mestre em Ensino do 1.º e do 2.º Ciclo do Ensino Básico
Resumo:
In this paper a modified version of the classical Van der Pol oscillator is proposed, introducing fractional-order time derivatives into the state-space model. The resulting fractional-order Van der Pol oscillator is analyzed in the time and frequency domains, using phase portraits, spectral analysis and bifurcation diagrams. The fractional-order dynamics is illustrated through numerical simulations of the proposed schemes using approximations to fractional-order operators. Finally, the analysis is extended to the forced Van der Pol oscillator.
Resumo:
Dissertação apresentada ao Instituto Politécnico do Porto para obtenção do Grau de Mestre em Gestão das Organizações, Ramo de Gestão de Empresas Orientada pelo Professor Doutor José Freitas Santos
Resumo:
A elaboração deste trabalho surge no âmbito da unidade curricular de Tese/Dissertação, pertencente ao Mestrado em Engenharia Eletrotécnica e Computadores, ramo de Automação e Sistemas, do Instituto Superior de Engenharia do Porto (ISEP). Este trabalho enquadra-se no âmbito da robótica de inspiração biológica no meio aquático. Pretendeu-se com este trabalho desenvolver e implementar um robô nadador de inspiração biológica. Inicialmente foi realizado um estudo acerca da locomoção dos peixes, para perceber a sua forma de se movimentar. Foi ainda efetuado um estudo acerca dos robôs nadadores existentes, de forma a verificar a sua constituição e formas de locomoção. Numa fase inicial foi desenvolvido um protótipo e, de seguida, procedeu-se à implementação do robô de uma forma sequencial. Implementou-se a estrutura do robô, com o objetivo de se assemelhar o mais possível com um peixe biológico. Foram utilizados servomotores para a locomoção do robô. Para que o robô possua a capacidade de se movimentar numa determinada direção recorreu-se à utilização de uma bússola digital. Posteriormente introduziu-se um emissor/recetor de radiofrequência (RF) para ligar/desligar o robô. Numa fase final procederam-se aos testes da locomoção do robô. Nos ensaios realizados verificou-se que o robô conseguiu nadar com estabilidade e com sentido de direção.
Resumo:
“Cork taint” is a major problem in wine industry and is caused by contamination of wines. This contamination is usually attributed to wine cork stoppers and 2,4,6-trichloroanisole (2,4,6-TCA) is one of the compounds mostly associated to this off-flavour. In this work, a consumer panel performed “forced choice” triangular tests in order to measure Odour Detection Thresholds (ODT) and Taste Detection Thresholds (TDT) of 2,4,6-TCA in water, hydro-alcoholic solutions (11.5% and 18% ethanol) and white and red wines. A paired preference test was also performed by the panel in order to measure Odour Rejection Threshold (ORT) in white and red wine spiked with 2,4,6-TCA. Results obtained show that the ODT and the TDT for 2,4,6-TCA in water were 0.2 and 0.3 ng/L, respectively. In hydro-alcoholic solutions with 11.5% and 18% ethanol the ODT were 4 and 10 ng/L respectively. In red wine the ODT and the TDT were 0.9 and 1.7 ng/L and in white wine were 1.5 and 1.0 ng/L respectively. ORT for white was 10.4 ng/L and for red wines 16.0 ng/L. These results suggest that although this group of consumers detected very low concentrations of 2,4,6-TCA in wines, they did not reject the wine at these low concentration values.