453 resultados para Fabricas - Iluminação


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Advanced age may become a limiting factor for the maintenance of rhythms in organisms, reducing the capacity of generation and synchronization of biological rhythms. In this study, the influence of aging on the expression of endogenous periodicity and synchronization (photic and social) of the circadian activity rhythm (CAR) was evaluated in a diurnal primate, the marmoset (Callithrix jacchus). This study had two approaches: one with longitudinal design, performed with a male marmoset in two different phases: adult (three years) and older (9 y.o.) (study 1) and the second, a transversal approach, with 6 old (♂: 9.7 ± 2.0 y.o.) and 11 adults animals (♂: 4.2 ± 0.8 y.o.) (study 2). The evaluation of the photic synchronization involved two conditions in LD (natural and artificial illuminations). In study 1, the animal was subjected to the following stages: LD (12:12 ~ 350: ~ 2 lx), LL (~ 350 lx) and LD resynchronization. In the second study, the animals were initially evaluated in natural LD, and then the same sequence stages of study 1. During the LL stage in study 2, the vocalizations of conspecifics kept in natural LD on the outside of the colony were considered temporal cue to the social synchronization. The record of the activity was performed automatically at intervals of five minutes through infrared sensor and actimeters, in studies 1 and 2, respectively. In general, the aged showed a more fragmented activity pattern (> IV < H and > PSD, ANOVA, p < 0.05), lower levels of activity (ANOVA, p < 0.05) and shorter duration of active phase (ANOVA, p < 0.05) in LD conditions, when compared to adults. In natural LD, the aged presented phase delay pronounced for onset and offset of active phase (ANOVA, p < 0.05), while the adults had the active phase more adjusted to light phase. Under artificial LD, there was phase advance and greater adjustment of onset and offset of activity in relation to the LD in the aged (ANOVA, p < 0.05). In LL, there was a positive correlation between age and the endogenous period () in the first 20 days (Spearman correlation, p < 0.05), with prolonged  held in two aged animals. In this condition, most adults showed free-running period of the circadian activity rhythm with  < 24 h for the first 30 days and later on relative coordination mediated by auditory cues. In study 2, the cross-correlation analysis between the activity profiles of the animals in LL with control animals kept under natural LD, found that there was less social synchronization in the aged. With the resubmission to the LD, the resynchronization rate was slower in the aged (t-test; p < 0.05) and in just one aged animal there was a loss of resynchronization capability. According to the data set, it is suggested that the aging in marmosets may be related to: 1) lower amplitude and greater fragmentation of the activity, accompanied to phase delay with extension of period, caused by changes in a photic input, in the generation and behavioral expression of the CAR; 2) lower capacity of the circadian activity rhythm to photic synchronization, that can become more robust in artificial lighting conditions, possibly due to the higher light intensities at the beginning of the active phase due to the abrupt transitions between the light and dark phases; and 3) smaller capacity of non-photic synchronization for auditory cues from conspecifics, possibly due to reducing sensory inputs and responsiveness of the circadian oscillators to auditory cues, what can make the aged marmoset most vulnerable, as these social cues may act as an important supporting factor for the photic synchronization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Advanced age may become a limiting factor for the maintenance of rhythms in organisms, reducing the capacity of generation and synchronization of biological rhythms. In this study, the influence of aging on the expression of endogenous periodicity and synchronization (photic and social) of the circadian activity rhythm (CAR) was evaluated in a diurnal primate, the marmoset (Callithrix jacchus). This study had two approaches: one with longitudinal design, performed with a male marmoset in two different phases: adult (three years) and older (9 y.o.) (study 1) and the second, a transversal approach, with 6 old (♂: 9.7 ± 2.0 y.o.) and 11 adults animals (♂: 4.2 ± 0.8 y.o.) (study 2). The evaluation of the photic synchronization involved two conditions in LD (natural and artificial illuminations). In study 1, the animal was subjected to the following stages: LD (12:12 ~ 350: ~ 2 lx), LL (~ 350 lx) and LD resynchronization. In the second study, the animals were initially evaluated in natural LD, and then the same sequence stages of study 1. During the LL stage in study 2, the vocalizations of conspecifics kept in natural LD on the outside of the colony were considered temporal cue to the social synchronization. The record of the activity was performed automatically at intervals of five minutes through infrared sensor and actimeters, in studies 1 and 2, respectively. In general, the aged showed a more fragmented activity pattern (> IV < H and > PSD, ANOVA, p < 0.05), lower levels of activity (ANOVA, p < 0.05) and shorter duration of active phase (ANOVA, p < 0.05) in LD conditions, when compared to adults. In natural LD, the aged presented phase delay pronounced for onset and offset of active phase (ANOVA, p < 0.05), while the adults had the active phase more adjusted to light phase. Under artificial LD, there was phase advance and greater adjustment of onset and offset of activity in relation to the LD in the aged (ANOVA, p < 0.05). In LL, there was a positive correlation between age and the endogenous period () in the first 20 days (Spearman correlation, p < 0.05), with prolonged  held in two aged animals. In this condition, most adults showed free-running period of the circadian activity rhythm with  < 24 h for the first 30 days and later on relative coordination mediated by auditory cues. In study 2, the cross-correlation analysis between the activity profiles of the animals in LL with control animals kept under natural LD, found that there was less social synchronization in the aged. With the resubmission to the LD, the resynchronization rate was slower in the aged (t-test; p < 0.05) and in just one aged animal there was a loss of resynchronization capability. According to the data set, it is suggested that the aging in marmosets may be related to: 1) lower amplitude and greater fragmentation of the activity, accompanied to phase delay with extension of period, caused by changes in a photic input, in the generation and behavioral expression of the CAR; 2) lower capacity of the circadian activity rhythm to photic synchronization, that can become more robust in artificial lighting conditions, possibly due to the higher light intensities at the beginning of the active phase due to the abrupt transitions between the light and dark phases; and 3) smaller capacity of non-photic synchronization for auditory cues from conspecifics, possibly due to reducing sensory inputs and responsiveness of the circadian oscillators to auditory cues, what can make the aged marmoset most vulnerable, as these social cues may act as an important supporting factor for the photic synchronization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho visa analisar o potencial do sombreamento vegetal no edifício para promover conforto térmico, luminoso e eficiência energética, a partir de simulações computacionais nos softwares DesignBuilder e Daysim. Foram simuladas diferentes combinações de fator de céu visível (FCV), transparência da copa vegetal e percentual de abertura da fachada (PAF) para edificação residencial térrea em Nata/RN, a fim de quantificar os impactos e propor recomendações projetuais. Os modelos foram analisados por meio do método de conforto adaptativo indicado pela ASHRAE Standard 55 (ASHRAE, 2010), classificação do nível de eficiência energética do Regulamento Técnico da Qualidade para o Nível de Eficiência Energética de Edificações Residenciais (RTQ-R), resultados de Daylight autonomy (DA) e uniformidade da luz natural para as exigências lumínicas de 100-300-500 lux. Os resultados demonstram grande potencial para integração da vegetação na edificação, principalmente para os fatores de céu médio e grande, e falta de coerência do RTQ-R para classificar as edificações da Zona bioclimática 08 pelo método de simulação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho visa analisar o potencial do sombreamento vegetal no edifício para promover conforto térmico, luminoso e eficiência energética, a partir de simulações computacionais nos softwares DesignBuilder e Daysim. Foram simuladas diferentes combinações de fator de céu visível (FCV), transparência da copa vegetal e percentual de abertura da fachada (PAF) para edificação residencial térrea em Nata/RN, a fim de quantificar os impactos e propor recomendações projetuais. Os modelos foram analisados por meio do método de conforto adaptativo indicado pela ASHRAE Standard 55 (ASHRAE, 2010), classificação do nível de eficiência energética do Regulamento Técnico da Qualidade para o Nível de Eficiência Energética de Edificações Residenciais (RTQ-R), resultados de Daylight autonomy (DA) e uniformidade da luz natural para as exigências lumínicas de 100-300-500 lux. Os resultados demonstram grande potencial para integração da vegetação na edificação, principalmente para os fatores de céu médio e grande, e falta de coerência do RTQ-R para classificar as edificações da Zona bioclimática 08 pelo método de simulação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PEDRINI, Aldomar; SZOKOLAY, Steven. Recomendações para o desenvolvimento de uma ferramenta de suporte às primeiras decisões projetuais visando ao desempenho energético de edificações de escritório em clima quente. Ambiente Construído, Porto Alegre, v. 5, n. 1, p.39-54, jan./mar. 2005. Trimestral. Disponível em: . Acesso em: 04 out. 2010.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este estudo objetivou conhecer a incidência do evento queda e identificar a presença de seus principais fatores de risco. Estudo exploratório, realizado de março a novembro/2009, com aplicação de um formulário sobre quedas em um grupo de idosos. Os dados foram analisados por cálculo de frequências, média e desvio-padrão. Participaram 62 idosos, 41,9% relataram queda nos últimos seis meses, a maioria mulheres. Identificou-se ocorrência de agravos concomitantes: visão regular, audição boa, polifarmácia, IMC normal, forte força de preensão palmar e condições dos pés adequadas. Na maioria dos que caiu, o desequilíbrio foi apontado como principal motivo. A queda ocorreu mais no período da manhã, em local de piso áspero e seco, sem degraus, rampas ou tapetes, iluminação adequada e o tipo de calçado mais utilizado foi chinelo de borracha. Percebe-se a alta ocorrência das quedas na população idosa, fato que fundamenta a necessidade de avaliação das condições de risco envolvidas

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Sociedade da Água de Luso, S.A., localizada no concelho de Mealhada, é uma empresa do setor do engarrafamento de águas minerais naturais, de nascente e de consumo humano. Esta realiza as suas atividades, tendo em consideração a eficiência energética, ao longo do seu processo produtivo. Desta forma, o trabalho desenvolvido teve como objetivo o acompanhamento da implementação do sistema de monitorização e recolha de dados, que posteriormente foi útil na redução dos consumos energéticos (consumo de ar comprimido). Para além disto, também foi proposta uma medida de eficiência energética que visa a redução de energia elétrica na área da iluminação. O sistema de monitorização e recolha de dados e a criação de uma equipa de redução do consumo de ar comprimido permitiram a identificação das áreas de atuação, a monitorização das metas estipuladas no âmbito da equipa e a detecção de anomalias. A medida de eficiência energética aplicada incide na substituição de lâmpadas fluorescentes tubulares T8 por lâmpadas fluorescentes tubulares T5. Assim, a implementação deste sistema e a aplicação das medidas de eficiência energética na rede de ar comprimido no âmbito da equipa permitiram uma redução de 0,03 kWh/hL o que significa uma poupança de 5.600 € em quinze semanas. Ao nível da iluminação as medidas sugeridas permitem uma redução de 8.945 kWh/ano o que corresponde a uma poupança de 1.055 €/ano.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Building design is an effective way to achieve HVAC energy consumption reduction. However, this potentiality is often neglected by architects due to the lack of references to support design decisions. This works intends to propose architectural design guidelines for energy efficiency and thermal performance of Campus/UFRN buildings. These guidelines are based on computer simulations results using the software DesignBuilder. The definition of simulation models has begun with envelope variables, partially done after a field study of thirteen buildings at UFRN/Campus. This field study indicated some basic envelope patterns that were applied in simulation models. Occupation variables were identified with temperature and energy consumption monitoring procedures and a verification of illumination and equipment power, both developed at the Campus/UFRN administration building. Three simulation models were proposed according to different design phases and decisions. The first model represents early design decisions, simulating the combination of different types of geometry with three levels of envelope thermal performance. The second model, still as a part of early design phase, analyses thermal changes between circulation halls lateral and central and office rooms, as well as the heat fluxes and monthly temperatures in each circulation hall. The third model analyses the influence of middle-design and detail design decisions on energy consumption and thermal performance. In this model, different solutions of roofs, shading devices, walls and external colors were simulated. The results of all simulation models suggest a high influence of thermal loads due to the incidence of solar radiation on windows and surfaces, which highlights the importance of window shading devices, office room orientation and absorptance of roof and walls surfaces

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El presente trabajo constituye un análisis del proceso de formulación de un proyecto elaborado dentro del Régimen para la Recuperación de la Ganadería Ovina (Ley N°25.422). El objetivo es analizar y reflexionar sobre las características que asume el proceso de formulación de proyectos de desarrollo rural-urbano en el marco de programas o herramientas estatales destacando sus límites y posibilidades. Para tal fin se utilizó un abordaje cualitativo, realizando un análisis de caso instrumental, utilizando la especificidad del proyecto formulado para entrever la generalidad de la dinámica del proceso de formulación. Siempre teniendo en cuenta las diferencias entre una investigación propiamente dicha y la formulación de un proyecto donde la intervención y modificación de la realidad tienen una mayor proporción. El proyecto cuya formulación es analizada que se realizó con el objetivo inicial de diseñar una cadena agroindustrial de lana Merino apuntando a alcanzar un producto de alta calidad para el mercado nacional. Sin embargo, de cara a los hechos, y a partir de la dinámica que se produjo entre los actores que llevaron a cabo la formulación del proyecto, el mismo resultó en una prueba piloto de pequeña envergadura. A saber, un proyecto para la elaboración de carretes de hilo de lana Merino integrando una Cooperativa Agropecuaria de la provincia de Río Negro, conformada por pequeños productores ovinos, y dos Cooperativas de Trabajo (fábricas textiles recuperadas) del conurbano bonaerense destinadas al lavado y peinado de lana e hilados respectivamente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente relatório resulta de um estágio realizado no âmbito da eficiência energética assente no programa Galp 20-20-20 que tem por génese uma parceria entre a Universidade de Aveiro e a empresa de coberturas cerâmicas, CS – Coelho da Silva S.A. A Fábrica alvo de estudo é uma consumidora intensiva de energia, despendeu no ano de 2013 cerca de 3.768 tep. Devido aos seus processos de cozedura e secagem, apresenta uma elevada dependência de Gás Natural, representando pouco mais de 78% do consumo global da fábrica. Deste consumo de energia térmica, 83% respeita ao forno e os restantes 17% encontram-se alocados ao secador, pelo que as medidas de eficiência energética presentes neste relatório centram-se da redução deste vetor energético. São então propostas três medidas para a redução da dependência deste vetor. A primeira, incide na recuperação de calor residual presente nos gases de exaustão através da instalação de um permutador de calor. Esta medida permite uma redução do consumo na ordem dos 10% e conta com um payback de 2,3 anos resultante de uma economia anual de 150.000 €. Para este estudo foi desenvolvido um modelo dinâmico em excel que permite a simulação de diversos cenários. São também propostas mais duas intervenções que incidem na alteração do circuito térmico. Estas medidas têm um impacte mais reduzido no que respeita ao percentual de redução energético, ambas com menos de 1% de redução do consumo global da fábrica. Contudo são medidas bastante interessantes dada a sua simplicidade e contam com poupanças anuais na ordem dos 6.000 € que resultam num payback inferior a 2 meses. Paralelamente executaram-se dois estudos para a iluminação, o primeiro sugere a instalação de um modelador de tensão que reduz a potência de iluminação em 36%, implicando uma redução da iluminância de cerca de 5%. A redução da potência resulta numa economia energética na ordem dos 0,4% da energia global da instalação. Este equipamento poderá ser adquirido por completo ou em renting. Ao optar pela compra integral, o investimento será apenas ressarcido em 2,8 anos resultante de uma poupança anula de perto de 6.500 €. Caso seja por renting este não tem qualquer custo adicional e as economias monetárias são partilhadas entre a empresa que fornece o equipamento e a CS-Coelho da Silva, S.A. Por fim é sugerida a substituição de parte da iluminação atual da fábrica por tecnologia LED, com esta medida reduz-se o consumo global em 0,76%. Esta medida gera uma economia monetária na ordem dos 11.500 € sendo ressarcida em 2,1 anos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente relatório de projeto explicita as etapas da elaboração e os resultados obtidos através da realização de um projeto de reabilitação energética de um complexo de piscinas interiores. Esta reabilitação energética tem por objetivo a redução dos custos energéticos através da subtração de consumos supérfluos de energia ou da melhoria da eficiência energética dos equipamentos. Para alcançar estes objetivos recorreu-se à simulação dinâmica do edifício de modo a estimar múltiplas variáveis energéticas e identificar quais os setores e equipamentos que maior influência têm no consumo energético do complexo em estudo. Para a realização da simulação, recorreu-se a um software desenvolvido pelo DOE dos Estados Unidos da América, o Energy Plus, com o auxílio do Design Builder, que permite a criação e edição do modelo de forma mais fácil e acessível. Os valores retirados da simulação foram posteriormente comparados com valores reais. Com o complexo caraterizado e os principais consumidores identificados foi possível iniciar o estudo das medidas de melhoria da eficiência energética. As principais medidas estudadas incidiram na instalação de coberturas isotérmicas nas piscinas para reduzir a perda de energia através da evaporação e da radiação, a introdução de fontes de energia renovável como alternativa energética, substituição de elementos do sistema de iluminação e o aproveitamento de energia dissipada em equipamentos. Com este estudo, a entidade gestora do complexo encontra-se mais informada e pronta a tomar decisões que influenciem de forma significativa o consumo de energia no complexo, podendo optar pela instalação de alguma das medidas propostas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Public Lightning is an important part of municipality’s nighttime landscape. Lighting can be used to enhance public safety and security while improving the aesthetic appeal of the surrounding properties but with the current global financial crisis, such lighting systems must also be sustainable. Most climate policy efforts focus on the state and international level, however national governments won’t be able to meet their international commitments without local action. In Portugal, the Public Lighting is responsible for 3% of energy consumption. The problem is that the trend is to increase (about 4-5% per year) which represents very high costs for the municipal authorities. In terms of numbers are analyzed in this thesis 45 of 278 existent in Continental Portugal what represents only 16,2 % of the counties. This where the local authorities in Portugal that had a Sustainable Energy Action Plan (SEAP) that had been accepted and made available in the Covenant of Mayors website until the end of year 2013. It is important that the Covenant of Mayors will increase the local authorities awareness for energy efficiency and especially to public lighting because there is still a long way to go in terms of energy consumption reduction. In future works it would be interesting to see the payback of the EolGreen post in a real scenario due to lack of energy consumption from the grid it would allow to have a pretty high initial investment even with the maintenance that those technologies need.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A dor tem sido apontada como uma das principais causas do sofrimento humano, contribuindo para a diminuição da qualidade de vida, tanto a nível psicossocial como económico. O seu controlo no pós-operatório tem sido palco de investigação pela frequência do fenómeno e pelas consequências de sofrimento e riscos desnecessários para a pessoa que a sofre. O enfermeiro no âmbito das suas competências profissionais, encontra-se numa posição relevante para promover o bem-estar e conforto recorrendo a intervenções farmacológicas e não farmacológicas para o seu controlo. O ambiente físico da unidade de cuidados pós-cirúrgicos pode atuar como mais uma fonte de desconforto e assim contribuir para aumentar a complexidade da gestão da dor da pessoa alvo de cuidados. Assim, pretende-se analisar a influência da iluminação e da temperatura ambiente da unidade como estímulos nas manifestações de dor da pessoa em pós-operatório imediato e, a gestão das mesmas por parte do enfermeiro. É um estudo descritivo, exploratório, de natureza observacional, realizado numa unidade de cuidados pós cirúrgicos de uma unidade hospitalar. Os dados foram colhidos em 64 observações de prestação de cuidados - por dez enfermeiros - nas primeiras quatro horas após a admissão da pessoa submetida a cirurgia. Foi construída, para registos de dados, uma lista de verificação que inclui condições de temperatura ambiente, grau de sedação e indicadores não-verbais de dor. Os principais resultados obtidos demonstram que a pessoa em situação pós-cirúrgica que se encontra num ambiente em que a iluminação natural e a temperatura estão mais controladas ou ausentes apresenta um número de episódios de dor menor do que aquela que se encontra num ambiente com iluminação intensa ou ambiente térmico não controlado. A gestão da luminosidade poderá ter influenciado mais a ausência de manifestações de dor, do que a gestão da temperatura ambiente. Há recurso quase exclusivo à terapêutica farmacológica para o controlo da dor da pessoa em situação pós cirúrgica. Não se observam comportamentos intencionais de controlo das condições de iluminação e temperatura da unidade nas primeiras horas de pós-operatório.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PEDRINI, Aldomar; SZOKOLAY, Steven. Recomendações para o desenvolvimento de uma ferramenta de suporte às primeiras decisões projetuais visando ao desempenho energético de edificações de escritório em clima quente. Ambiente Construído, Porto Alegre, v. 5, n. 1, p.39-54, jan./mar. 2005. Trimestral. Disponível em: . Acesso em: 04 out. 2010.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This master thesis introduces assessment procedures of daylighting performance in office rooms with shaded opening, recommendations for Natal-RN (Latitude 05,47' S, Longitude 35,11' W). The studies assume the need of window exterior shading in hot and humid climate buildings. The daylighting performance analyses are based on simulated results for three levels of illuminance (300,500 e 1000 lux) between 08h00 e 16h00, in rooms with 2,80 m height, 6 m large and 4 m, 6 m e 8 m depths, with a centered single opening, window wall ratio (20%, 40% e 60%), four orientations (North, East, South and West), and two types of sky (clear and partially cloudy). The sky characteristics were statistically determined based on hourly data from INPE-CRN solar and daylighting weather station. The lighting performance is resulted from dynamic computer simulation of 72 models using Troplux 3.12. The simulation results were assessed using a new parameter to quantify the use of interior daylighting, the useful percentage of daylight (PULN), which corresponds to the time fraction with satisfactory light, in accordance with the illuminance design. The passive zone depths are defined based on the PULN. Despite the failures of illuminance data from the weather station, the analyses ratified the high potential of daylighting for shaded rooms. The most influential variables on the lighting performance are the opening size and the illuminance of design, while the orientation is a little influential