954 resultados para FREE-TRYPTOPHAN


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract We introduce a label-free technology based on digital holographic microscopy (DHM) with applicability for screening by imaging, and we demonstrate its capability for cytotoxicity assessment using mammalian living cells. For this first high content screening compatible application, we automatized a digital holographic microscope for image acquisition of cells using commercially available 96-well plates. Data generated through both label-free DHM imaging and fluorescence-based methods were in good agreement for cell viability identification and a Z'-factor close to 0.9 was determined, validating the robustness of DHM assay for phenotypic screening. Further, an excellent correlation was obtained between experimental cytotoxicity dose-response curves and known IC values for different toxic compounds. For comparable results, DHM has the major advantages of being label free and close to an order of magnitude faster than automated standard fluorescence microscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We introduce a microscopic method that determines quantitative optical properties beyond the optical diffraction limit and allows direct imaging of unstained living biological specimens. In established holographic microscopy, complex fields are measured using interferometric detection, allowing diffraction-limited phase measurements. Here, we show that non-invasive optical nanoscopy can achieve a lateral resolution of 90 nm by using a quasi-2 pi-holographic detection scheme and complex deconvolution. We record holograms from different illumination directions on the sample plane and observe subwavelength tomographic variations of the specimen. Nanoscale apertures serve to calibrate the tomographic reconstruction and to characterize the imaging system by means of the coherent transfer function. This gives rise to realistic inverse filtering and guarantees true complex field reconstruction. The observations are shown for nanoscopic porous cell frustule (diatoms), for the direct study of bacteria (Escherichia coil), and for a time-lapse approach to explore the dynamics of living dendritic spines (neurones).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Object: The authors sought to establish whether the safety-efficacy of Gamma Knife radiosurgery (GKRS) as a second treatment for intractable trigeminal neuralgia (ITN) are influenced by prior microvascular decompression (MVD) which remains, for some of the authors, the reference technique. Methods: Between July 1992 and November 2010, 737 patients have been operated with GKRS for ITN and prospectively evaluated in Timone University Hospital in Marseille, France. Among these, 54 patients had a previous MVD history. Radiosurgery using a Gamma Knife (model B or C or Perfexion) was performed relying on both MR and CT targeting. A single 4 mm isocenter was positioned in the cisternal portion of the trigeminal nerve at a median distance of 7.6 mm (range 3.9- 11.9) anteriorly to the emergence of the nerve (retrogasserian target). A median maximum dose of 85 Gy (range 70-90) was delivered. Are further analyzed only 45 patients with previous MVD and a follow-up longer than one year (the patients with megadolichobasilar artery compression and multiple sclerosis were excluded). Results: The median age in this series was 56.75 years (range 28.09-82.39). The median follow-up period was 39.48 months (range 14.10-144.65). All the patients had a past history of surgery, with at least one previous failed MVD, but also a radiofrequency lesion (RFL) in 16 (35.6%) patients, balloon microcompression in 7 (15.6%) patients and glycerol rhizotomy in 1 case (2.2%). Thirty-five patients (77.8%) were initially pain free in a median time of 14 days (range 0, 180). Patients from this group had less probability of being pain free compared to our global population of essential trigeminal neuralgia without previous MVD history (p=0.010, hazard ratio of 0.64). Their probability of remaining pain free at 3, 5, 7 and 10 years was 66.5%, 59.1%, 59.1% and 44.3%, respectively. Twelve patients (34.3%) initially pain free experienced a recurrence with a median delay of 31.21 months (range 3.40-89.93). The hypoesthesia actuarial rate at 1 year was 9.1% and remained stable till 12 years with a median delay of onset of 8 months (range 8-8). Conclusions: Retrogasserian GKRS proofed to be safe and effective on the long-term basis even after failed previous MVD. Even if the initial result of pain free was of only 77.8%, the toxicity was low with only 9.1% hypoesthesia. No patient reported a bothersome hypoesthesia. The probability of maintaining pain relief in long-term was of 44.3% at 10 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Coronary in-stent restenosis cannot be directly assessed by magnetic resonance angiography (MRA) because of the local signal void of currently used stainless steel stents. The aim of this study was to investigate the potential of a new, dedicated, coronary MR imaging (MRI) stent for artifact-free, coronary MRA and in-stent lumen and vessel wall visualization. METHODS AND RESULTS: Fifteen prototype stents were deployed in coronary arteries of 15 healthy swine and investigated with a double-oblique, navigator-gated, free-breathing, T2-prepared, 3D cartesian gradient-echo sequence; a T2-prepared, 3D spiral gradient-echo sequence; and a T2-prepared, 3D steady-state, free-precession coronary MRA sequence. Furthermore, black-blood vessel wall imaging by a dual-inversion-recovery, turbo spin-echo sequence was performed. Artifacts of the stented vessel segment and signal intensities of the coronary vessel lumen inside and outside the stent were assessed. With all investigated sequences, the vessel lumen and wall could be visualized without artifacts, including the stented vessel segment. No signal intensity alterations inside the stent when compared with the vessel lumen outside the stent were found. CONCLUSIONS: The new, coronary MRI stent allows for completely artifact-free coronary MRA and vessel wall imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite increasing numbers of women attaining higher level academic degrees, gender disparities remain among higher education and among university faculties. Some have posited that this may stem from inadequate academic identity development of women at the doctoral level. While existing gender differences may stem from multiple and variable origins, mentoring has been proposed as a viable means to promote academic identity development and address these gender gaps. This study used a qualitative, narrative case study design to evaluate "StartingDoc" a structured mentoring program launched among Swiss Universities aimed at promoting networking and academic identity development among female doctoral students. Herein we describe the 9 emergent themes which arose from the small-group mentoring program and suggest that such an approach is both feasible and beneficial for young female academics. Further work is needed to elucidate the most effective strategies for developing and retaining women in academia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This letter discusses the detection and correction ofresidual motion errors that appear in airborne synthetic apertureradar (SAR) interferograms due to the lack of precision in the navigationsystem. As it is shown, the effect of this lack of precision istwofold: azimuth registration errors and phase azimuth undulations.Up to now, the correction of the former was carried out byestimating the registration error and interpolating, while the latterwas based on the estimation of the phase azimuth undulations tocompensate the phase of the computed interferogram. In this letter,a new correction method is proposed, which avoids the interpolationstep and corrects at the same time the azimuth phase undulations.Additionally, the spectral diversity technique, used to estimateregistration errors, is critically analyzed. Airborne L-bandrepeat-pass interferometric data of the German Aerospace Center(DLR) experimental airborne SAR is used to validate the method

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors developed a free-breathing black-blood coronary magnetic resonance (MR) angiographic technique with a potential for exclusive visualization of the coronary blood pool. Results with the MR angiographic technique were evaluated in eight healthy subjects and four patients with coronary disease identified at conventional angiography. This MR angiographic technique accurately depicted luminal disease in the patients and permitted visualization of extensive continuous segments of the native coronary tree in both the healthy subjects and the patients. Black-blood coronary MR angiography provides an alternative source of contrast enhancement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Three-dimensional (3D) navigator-gated and prospectively corrected free-breathing coronary magnetic resonance angiography (MRA) allows for submillimeter image resolution but suffers from poor contrast between coronary blood and myocardium. Data collected over >100 ms/heart beat are also susceptible to bulk cardiac and respiratory motion. To address these problems, we examined the effect of a T2 preparation prepulse (T2prep) for myocardial suppression and a shortened acquisition window on coronary definition. METHODS AND RESULTS: Eight healthy adult subjects and 5 patients with confirmed coronary artery disease (CAD) underwent free-breathing 3D MRA with and without T2prep and with 120- and 60-ms data-acquisition windows. The T2prep resulted in a 123% (P<0. 001) increase in contrast-to-noise ratio (CNR). Coronary edge definition was improved by 33% (P<0.001). Acquisition window shortening from 120 to 60 ms resulted in better vessel definition (11%; P<0.001). Among patients with CAD, there was a good correspondence with disease. CONCLUSIONS: Free-breathing, T2prep, 3D coronary MRA with a shorter acquisition window resulted in improved CNR and better coronary artery definition, allowing the assessment of coronary disease. This approach offers the potential for free-breathing, noninvasive assessment of the major coronary arteries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate morbidity associated with the radial forearm free flap donor site and to compare functional and aesthetic outcomes of ulnar-based transposition flap (UBTF) vs split-thickness skin graft (STSG) closure of the donor site.¦DESIGN: Case-control study.¦SETTING: Tertiary care institution.¦PATIENTS: The inclusion criteria were flap size not exceeding 30 cm(2), patient availability for a single follow-up visit, and performance of surgery at least 6 months previously. Forty-four patients were included in the study and were reviewed. Twenty-two patients had UBTF closure, and 22 had STSG closure.¦MAIN OUTCOME MEASURES: Variables analyzed included wrist mobility, Michigan Hand Outcomes Questionnaire scores, pinch and grip strength (using a dynamometer), and hand sensitivity (using monofilament testing over the radial nerve distribution). In analyses of operated arms vs nonoperated arms, variables obtained only for the operated arms included Vancouver Scar Scale scores and visual analog scale scores for Aesthetics and Overall Arm Function.¦RESULTS: The mean (SD) wrist extension was significantly better in the UBTF group (56.0° [10.4°] for nonoperated arms and 62.0° [9.7°] for operated arms) than in the STSG group (59.0° [7.1°] for nonoperated arms and 58.4° [12.1°] for operated arms) (P = .02). The improvement in wrist range of motion for the UBTF group approached statistical significance (P = .07). All other variables (Michigan Hand Outcomes Questionnaire scores, pinch and grip strength, hand sensitivity, and visual analog scale scores) were significantly better for nonoperated arms vs operated arms, but no significant differences were observed between the UBTF and STSG groups.¦CONCLUSIONS: The radial forearm free flap donor site carries significant morbidity. Donor site UBTF closure was associated with improved wrist extension and represents an alternative method of closure for small donor site defects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Diaphragmatic navigators are frequently used in free-breathing coronary MR angiography, either to gate or prospectively correct slice position or both. For such approaches, a constant relationship between coronary and diaphragmatic displacement throughout the respiratory cycle is assumed. The purpose of this study was to evaluate the relationship between diaphragmatic and coronary artery motion during free breathing. SUBJECTS AND METHODS: A real-time echoplanar MR imaging sequence was used in 12 healthy volunteers to obtain 30 successive images each (one per cardiac cycle) that included the left main coronary artery and the domes of both hemidiaphragms. The coronary artery and diaphragm positions (relative to isocenter) were determined and analyzed for effective diaphragmatic gating windows of 3, 5, and 7 mm (diaphragmatic excursions of 0-3, 0-5, and 0-7 mm from the end-expiratory position, respectively). RESULTS: Although the mean slope correlating the displacement of the right diaphragm and the left main coronary artery was approximately 0.6 for all diaphragmatic gating windows, we also found great variability among individual volunteers. Linear regression slopes varied from 0.17 to 0.93, and r2 values varied from .04 to .87. CONCLUSION: Wide individual variability exists in the relationship between coronary and diaphragmatic respiratory motion during free breathing. Accordingly, coronary MR angiographic approaches that use diaphragmatic navigator position for prospective slice correction may benefit from patient-specific correction factors. Alternatively, coronary MR angiography may benefit from a more direct assessment of the respiratory displacement of the heart and coronary arteries, using left ventricular navigators.