819 resultados para END-FUNCTIONALIZATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the effect of transient and sustained variations in cardiac load on the values of the end-systolic pressure-diameter relation (ESPDR) of the left ventricle. METHODS: We studied 13 dogs under general anesthesia and autonomic blockade. Variations of cardiac loads were done by elevation of blood pressure by mechanical constriction of the aorta. Two protocols were used in each animal: gradual peaking and decreasing pressure variation, the transient arterial hypertension protocol (TAH), and a quick and 10 min sustained elevation, the sustained arterial hypertension protocol(SAH). Then, we compared the ESDR in these two situations. RESULTS: Acute elevation of arterial pressure, being it transitory or sustained, did not alter the heart frequency and increased similarly the preload and after load. However, they acted differently in end systolic pressure-diameter relation. It was greater in the SAH than TAH protocol, 21.0±7.3mmHg/mm vs. 9.2±1.2mmHg/mm (p<0.05). CONCLUSION: The left ventricular ESPDR values determined during sustained pressure elevations were higher than those found during transient pressure elevations. The time-dependent activation of myocardial contractility associated with the Frank-Starling mechanism is the major factor in inotropic stimulation during sustained elevations of blood pressure, determining an increase in the ESPDR values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVOS: Comparar a neurorrafia término-lateral com epineuro versus sem epineuro. DESENHO: Foram operados 20 ratos. O nervo fibular foi seccionado e seu coto distal suturado na face lateral do nervo tibial. do lado direito nós removemos janela de epineuro e no lado esquerdo o epineuro foi deixado intacto. Depois de seis meses, os 14 animais sobreviventes foram submetidos a testes eletrofisiológicos, sacrificados e os nervos e músculos removidos para exames histológicos. O teste eletrofisiológico foi realizado mediante estímulo elétrico fornecido por um neuro-estimulador (LHM-110) com 2 milisegundos de duração, num modo repetido e 30 Hz. O estímulo foi aumentado progressivamente partindo de zero até atingir 1 volt. LOCAL: Faculdade de Medicina de Botucatu. RESULTADOS: No lado direito, os músculos que tiveram resposta positiva necessitaram uma média de 258,89 mv (±92,31) de estímulo elétrico para apresentar uma resposta e no lado esquerdo uma média de 298,34 mV (±139,32). O músculo tibial cranial apresentou peso médio para o lado direito de 0,47 g (±0,18) e para o lado esquerdo de 0,45 g (±0,15). O coto distal do nervo fibular apresentou uma média 310 fibras nervosas (±191,34) para o lado direito e 287,71 (±183,60) para o lado esquerdo. O nervo tibial acima da neurorrafia mostrou médias de 939,46 (±223,51) fibras nervosas para o lado direito e 959,46 (±327,48) para o lado esquerdo. O nervo tibial abaixo da neurorrafia mostrou médias de 935,17 (±298,65) fibras nervosas para o lado direito e 755,31 (±323,26) para o lado esquerdo. As fibras do músculo tibial cranial do lado direito apresentaram uma área média de 0,0162 (±0,008) m2 depois de 230 vezes de magnificação e 0,0152 (±0,0064) para as fibras do músculo tibial cranial do lado esquerdo. O aspecto histológico do músculo tibial cranial, tomando-se o normal como 100% foi de 78,21 (±20,75) para o lado direito e 82,14 (±15,89) para o lado esquerdo. A análise estatística (testetde Student) não mostrou diferenças (p>0,05) entre os lados esquerdo e direito para todas as variáveis. CONCLUSÕES: Ambas as neurorrafias (com e sem epineuro) não mostraram diferenças relacionadas aos aspectos morfológicos e eletrofisiológicos estudados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Through the text presented we intend to outline the debate that occurred in Portugal in the transition from the 19th to the 20th centuries. At the time, the imperatives of scientific development had reached education as a basis for the national prosperity. It was believed that Portugal had fallen behind in comparison to the other European countries because it was not capable of constructing a civilization directed by scientific criteria, through the expansion and spreading of culture. The debate over the extension of schools to increasingly broader segments of the population acquires a different meaning when the theorist of Education make use of language from several other areas of knowledge in order to create a mosaic of what has become known, since that time, as the Science of Education.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have studied a new type of end-to-side nerve repair in rats. The healthy (donor) nerve was not divided but an epineural window was created. In our experiment, a nerve graft bridged the tibial nerve to the distal end of the divided peroneal nerve. Electrophysiological studies showed electrical impulses conducted through both end-to-side nerve junctions. Histological studies demonstrated axons leaving the lateral surface of the healthy (donor) nerve. Based on these observations, we suggest that end-to-side neurorrhaphy from a healthy nerve may bridge a neural deficit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The end magnets of the IFUSP race-track microtron booster, second stage of the electron accelerator under construction at the Linear Accelerator Laboratory, are presented. They deflect, focus and return the beam to the accelerating section. Details about the project are discussed, Poisson code was used to give the final geometry of the end magnets. The end magnets incorporate auxiliary pole pieces (clamps) which create a reverse fringe field region that avoids the beam vertical defocusing and reduces the horizontal displacement produced by extended fringe fields (EFF). The small gap height used for the clamps provided reverse field distributions with fringe fields of short extensions, avoiding the traditional use of inactive clamps. Measurements and calculations concerning particle trajectories and reverse field distribution are presented. The floating wire technique, employing an original procedure to register orbits, was used to corroborate the calculated beam trajectories and represents a good experimental option in the lack of the accelerator beam. The experimental results showed agreement of about 0.1% with the calculations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The objective of this study was to evaluate periapical repair following retrograde filling using different root-end filling materials.Study design. After induction of periapical lesions, 48 root canals from do teeth were partially filled. Endodontic surgery was performed and 3 different materials were used for root-end filling: Sealer 26, Sealapex plus zinc oxide, or mineral trioxide aggregate (NITA). No additional procedures were performed in the control group after partial filling of the root canal. After 180 days, the animals were killed, the rnaxillas and mandibles were removed, and specimens were submitted for histologic processing.Results. Histopathologic analysis revealed similar periapical repair for the groups in which Sealer 26, Sealapex plus zinc oxide, and MTA were used (P >.05). The control group showed unsatisfactory periapical repair W <.05).Conclusion. There was no difference in periapical tissue healing alter retrograde filling with the tested materials, which indicates that these 3 root-end filling materials are equally useful.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spongiolite from Mato Grosso do Sul (Brazil), natural inorganic composite constituted of silica needles, was treated with concentrated phosphoric acid at high temperatures. Superficial coating of the needles was proved to be constituted of silicon diphosphate, a compound offering six-coordinated silicon sites. Owing to the affinity of three charged ions to phosphate groups, this coating acts as specific adsorbent for the rare earth elements which prefer octahedral coordination (starting from samarium, yttrium included). The uptake of lanthanum and neodymium are significantly lower due to different coordination tendencies. Lanthanide fixation upon silica with PO4 groups anchored on its surface may be useful in the manufacturing of special phosphate-silicate glasses. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We will present measurements and calculations related to the antisymmetric perturbations, and comparisons with the symmetric ones, of the IFUSP race-track microtron booster accelerator end magnets. These perturbations were measured in planes situated at +/-12 mm of the middle plane, in a gap height of 4 cm, for a field distribution of about 0.1 T. The measurements were done in 1170 points, separated by a distance of 8 mm, using an automated system with a +/-1.5 mu T differential Hall probe. The race-track microtron booster is the second stage of the 30.0 MeV electron accelerator under construction at the Linear Accelerator Laboratory in which the required uniformity for the magnetic field is of about 10(-3). The method of correction employed to homogenize the IFUSP race-track microtron booster accelerator magnets assures uniformity of 10(-5) in an average field of 0.1 T, over an area of 700 cm(2). This method uses the principle of attaching to the pole pieces correction coils produced by etching techniques, with copper leads shaped like the isofield lines of the normal component of the magnetic field measured. The ideal planes, in which these measurements are done, are calculated and depend on the behavior of the magnetic field perturbations: symmetric or antisymmetric with reference to the middle plane of the magnet gap. These calculations are presented in this work and show that for antisymmetric perturbations there is no ideal plane for the correction of the magnetic field; for the symmetric one, these planes are at +/-60% of the half gap height, from the middle plane. So this method of correction is not feasible for antisymmetric perturbations, as will be shown. Besides, the correction of the symmetric portion of the field distribution does not influence the antisymmetric one, which almost does not change, and corroborates the theoretical predictions. We found antisymmetric perturbations of small intensity only in one of the two end magnets. However, they are not detected at +/- 1 mm of the middle plane and will not damage the electron beam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim To assess the histological response associated with grey mineral trioxide aggregate (GMTA) and zinc oxide eugenol (ZOE) as root-end filling materials in teeth where the root canals were not filled and the coronal access cavities were not restored.Methodology Periapical lesions were developed in 24 premolar teeth in three dogs. The root canals were prepared and half of them were dried, filled and the coronal access restored (closed). The remaining teeth were not root filled and no coronal restoration was placed (open). Apical root-end resections were performed 3 mm from the apex, and root-end cavities were prepared with ultrasonic tips. These were randomly filled with either ZOE or GMTA in the same number of specimens using MAPSYSTEM device. After 180 days the animals were killed and blocks of tissues removed and processed for histological examination. Periradicular tissue reaction was evaluated, including severity of inflammation and cementum formation. Statistical analysis was performed using ANOVA analysis and Tukey's test.Results A significant difference was found between the levels of inflammation in the periradicular tissues of the GMTA/closed group, compared with the ZOE/open and ZOE/closed groups (P < 0.05) but not between GMTA/closed and GMTA/open groups. Cementum formation was not found over any ZOE specimens but over MTA in all specimens. No microorganisms were found in the interface between the material and the dentinal walls.Conclusions GMTA was associated with less periapical inflammation and tissue response when used as a root-end filling material, even when no root filling or coronal restoration was present.