942 resultados para Dynamic modulus of elasticity
Resumo:
Electric-powered wheelchairs improve the mobility of people with physical disabilities, but the problem to deal with certain architectural barriers has not been resolved satisfactorily. In order to solve this problem, a stair-climbing mobility system (SCMS) was developed. This paper presents a practical dynamic control system that allows the SCMS to exhibit a successful climbing process when faced with typical architectural barriers such as curbs, ramps, or staircases. The implemented control system depicts high simplicity, computational efficiency, and the possibility of an easy implementation in a microprocessor-/microcontroller-based system. Finally, experiments are included to support theoretical results.
Resumo:
We study experimentally the dynamic properties of a fully integrated high power master-oscillator power-amplifier emitting at 1.5 μm under continuous wave and gain-switching conditions. High peak power (2.7 W) optical pulses with short duration (~ 110 ps) have been generated by gain switching the master-oscillator. We show the existence of working points at very close driving conditions with stable or unstable regimes caused by the compound cavity effects. The optical and radio-frequency spectra of stable and unstable operating points are analyzed.
Resumo:
This work is related to the output impedance improvement of a Multiphase Buck converter with Peak Current Mode Control (PCMC) by means of introducing an additional power path that virtually increases the output capacitance during transients. Various solutions that can be employed to improve the dynamic behavior of the converter system exist, but nearly all solutions are developed for a Single Phase Buck converter with Voltage Mode Control (VMC), while in the VRM applications, due to the high currents, the system is usually implemented as a Multiphase Buck Converter with Current Mode Control. The additional energy path, as presented here, is introduced with the Output Impedance Correction Circuit (OICC) based on the Controlled Current Source (CCS). The OICC is used to inject or extract a current n-1 times larger than the output capacitor current, thus virtually increasing n times the value of the output capacitance during the transients. Furthermore, this work extends the OICC concept to a Multiphase Buck Converter system while comparing proposed solution with the system that has n times bigger output capacitor. In addition, the OICC is implemented as a Synchronous Buck Converter with PCMC, thus reducing its influence on the system efficiency.
Resumo:
The interest for modelling of human actions acting on structures has been recurrent since the first accidents on suspension bridges in the nineteenth century like Broughton (1831) in the U.K. or Angers (1850) in France. Stadiums, gymnasiums are other type of structure where the human induced vibration is very important. In these structures appear particular phenomenon like the interaction person-structure (lock-in), the person-person synchronization, and the influence of the mass and damping of the people in the structure behaviour. This work focuses on the latter topic. The dynamic characteristic of a structure can be changed due to the presence of people on it. In order to evaluate these property modifications several testing have been carried out on a structure designed to be a gymnasium. For the test an electro-dynamic shaker was installed in a fixed point of the gym slab and different groups of people were located around the shaker. In each test the number of people was changed and also their posture (standing and sitting). Test data were analyzed and processed to verify modifications in the structure behaviour.
Resumo:
The interest for modelling of human actions acting on structures has been recurrent since the first accidents on suspension bridges in the nineteenth century such as Broughton (1831) in the U.K. or Angers (1850) in France. Stadiums, gymnasiums are other types of structure where human induced vibration is very important. In these structures a particular phenomenon appears such as the interaction personstructure (lock-in), the person-person synchronization, and the influence of the mass and damping of the people in the structural behaviour. This paper focuses on the latter topic. In order to evaluate these property modifications several tests have been carried out on a stand-alone building. For the test an electro-dynamic shaker was installed at a fixed point of the gym slab and different groups of people were located around the shaker. The dynamic characteristics of the structure without people inside have been calculated by two methods: using a three-dimensional finite element model of the building and by operational modal analysis. These calculated experimental and numerical values are the reference values used to evaluate the modifications in the dynamic properties of the structure.
Resumo:
En la actualidad existe un gran conocimiento en la caracterización de rellenos hidráulicos, tanto en su caracterización estática, como dinámica. Sin embargo, son escasos en la literatura estudios más generales y globales de estos materiales, muy relacionados con sus usos y principales problemáticas en obras portuarias y mineras. Los procedimientos semi‐empíricos para la evaluación del efecto silo en las celdas de cajones portuarios, así como para el potencial de licuefacción de estos suelos durantes cargas instantáneas y terremotos, se basan en estudios donde la influencia de los parámetros que los rigen no se conocen en gran medida, dando lugar a resultados con considerable dispersión. Este es el caso, por ejemplo, de los daños notificados por el grupo de investigación del Puerto de Barcelona, la rotura de los cajones portuarios en el Puerto de Barcelona en 2007. Por estos motivos y otros, se ha decidido desarrollar un análisis para la evaluación de estos problemas mediante la propuesta de una metodología teórico‐numérica y empírica. El enfoque teórico‐numérico desarrollado en el presente estudio se centra en la determinación del marco teórico y las herramientas numéricas capaces de solventar los retos que presentan estos problemas. La complejidad del problema procede de varios aspectos fundamentales: el comportamiento no lineal de los suelos poco confinados o flojos en procesos de consolidación por preso propio; su alto potencial de licuefacción; la caracterización hidromecánica de los contactos entre estructuras y suelo (camino preferencial para el flujo de agua y consolidación lateral); el punto de partida de los problemas con un estado de tensiones efectivas prácticamente nulo. En cuanto al enfoque experimental, se ha propuesto una metodología de laboratorio muy sencilla para la caracterización hidromecánica del suelo y las interfaces, sin la necesidad de usar complejos aparatos de laboratorio o procedimientos excesivamente complicados. Este trabajo incluye por tanto un breve repaso a los aspectos relacionados con la ejecución de los rellenos hidráulicos, sus usos principales y los fenómenos relacionados, con el fin de establecer un punto de partida para el presente estudio. Este repaso abarca desde la evolución de las ecuaciones de consolidación tradicionales (Terzaghi, 1943), (Gibson, English & Hussey, 1967) y las metodologías de cálculo (Townsend & McVay, 1990) (Fredlund, Donaldson and Gitirana, 2009) hasta las contribuciones en relación al efecto silo (Ranssen, 1985) (Ravenet, 1977) y sobre el fenómeno de la licuefacción (Casagrande, 1936) (Castro, 1969) (Been & Jefferies, 1985) (Pastor & Zienkiewicz, 1986). Con motivo de este estudio se ha desarrollado exclusivamente un código basado en el método de los elementos finitos (MEF) empleando el programa MATLAB. Para ello, se ha esablecido un marco teórico (Biot, 1941) (Zienkiewicz & Shiomi, 1984) (Segura & Caron, 2004) y numérico (Zienkiewicz & Taylor, 1989) (Huerta & Rodríguez, 1992) (Segura & Carol, 2008) para resolver problemas de consolidación multidimensional con condiciones de contorno friccionales, y los correspondientes modelos constitutivos (Pastor & Zienkiewicz, 1986) (Fiu & Liu, 2011). Asimismo, se ha desarrollado una metodología experimental a través de una serie de ensayos de laboratorio para la calibración de los modelos constitutivos y de la caracterización de parámetros índice y de flujo (Castro, 1969) (Bahda 1997) (Been & Jefferies, 2006). Para ello se han empleado arenas de Hostun como material (relleno hidráulico) de referencia. Como principal aportación se incluyen una serie de nuevos ensayos de corte directo para la caracterización hidromecánica de la interfaz suelo – estructura de hormigón, para diferentes tipos de encofrados y rugosidades. Finalmente, se han diseñado una serie de algoritmos específicos para la resolución del set de ecuaciones diferenciales de gobierno que definen este problema. Estos algoritmos son de gran importancia en este problema para tratar el procesamiento transitorio de la consolidación de los rellenos hidráulicos, y de otros efectos relacionados con su implementación en celdas de cajones, como el efecto silo y la licuefacciones autoinducida. Para ello, se ha establecido un modelo 2D axisimétrico, con formulación acoplada u‐p para elementos continuos y elementos interfaz (de espesor cero), que tratan de simular las condiciones de estos rellenos hidráulicos cuando se colocan en las celdas portuarias. Este caso de estudio hace referencia clara a materiales granulares en estado inicial muy suelto y con escasas tensiones efectivas, es decir, con prácticamente todas las sobrepresiones ocasionadas por el proceso de autoconsolidación (por peso propio). Por todo ello se requiere de algoritmos numéricos específicos, así como de modelos constitutivos particulares, para los elementos del continuo y para los elementos interfaz. En el caso de la simulación de diferentes procedimientos de puesta en obra de los rellenos se ha requerido la modificacion de los algoritmos empleados para poder así representar numéricamente la puesta en obra de estos materiales, además de poder realizar una comparativa de los resultados para los distintos procedimientos. La constante actualización de los parámetros del suelo, hace también de este algoritmo una potente herramienta que permite establecer un interesante juego de perfiles de variables, tales como la densidad, el índice de huecos, la fracción de sólidos, el exceso de presiones, y tensiones y deformaciones. En definitiva, el modelo otorga un mejor entendimiento del efecto silo, término comúnmente usado para definir el fenómeno transitorio del gradiente de presiones laterales en las estructuras de contención en forma de silo. Finalmente se incluyen una serie de comparativas entre los resultados del modelo y de diferentes estudios de la literatura técnica, tanto para el fenómeno de las consolidaciones por preso propio (Fredlund, Donaldson & Gitirana, 2009) como para el estudio del efecto silo (Puertos del Estado, 2006, EuroCódigo (2006), Japan Tech, Stands. (2009), etc.). Para concluir, se propone el diseño de un prototipo de columna de decantación con paredes friccionales, como principal propuesta de futura línea de investigación. Wide research is nowadays available on the characterization of hydraulic fills in terms of either static or dynamic behavior. However, reported comprehensive analyses of these soils when meant for port or mining works are scarce. Moreover, the semi‐empirical procedures for assessing the silo effect on cells in floating caissons, and the liquefaction potential of these soils during sudden loads or earthquakes are based on studies where the underlying influence parameters are not well known, yielding results with significant scatter. This is the case, for instance, of hazards reported by the Barcelona Liquefaction working group, with the failure of harbor walls in 2007. By virtue of this, a complex approach has been undertaken to evaluate the problem by a proposal of numerical and laboratory methodology. Within a theoretical and numerical scope, the study is focused on the numerical tools capable to face the different challenges of this problem. The complexity is manifold; the highly non‐linear behavior of consolidating soft soils; their potentially liquefactable nature, the significance of the hydromechanics of the soil‐structure contact, the discontinuities as preferential paths for water flow, setting “negligible” effective stresses as initial conditions. Within an experimental scope, a straightforward laboratory methodology is introduced for the hydromechanical characterization of the soil and the interface without the need of complex laboratory devices or cumbersome procedures. Therefore, this study includes a brief overview of the hydraulic filling execution, main uses (land reclamation, filled cells, tailing dams, etc.) and the underlying phenomena (self‐weight consolidation, silo effect, liquefaction, etc.). It comprises from the evolution of the traditional consolidation equations (Terzaghi, 1943), (Gibson, English, & Hussey, 1967) and solving methodologies (Townsend & McVay, 1990) (Fredlund, Donaldson and Gitirana, 2009) to the contributions in terms of silo effect (Ranssen, 1895) (Ravenet, 1977) and liquefaction phenomena (Casagrande, 1936) (Castro, 1969) (Been & Jefferies, 1985) (Pastor & Zienkiewicz, 1986). The novelty of the study lies on the development of a Finite Element Method (FEM) code, exclusively formulated for this problem. Subsequently, a theoretical (Biot, 1941) (Zienkiewicz and Shiomi, 1984) (Segura and Carol, 2004) and numerical approach (Zienkiewicz and Taylor, 1989) (Huerta, A. & Rodriguez, A., 1992) (Segura, J.M. & Carol, I., 2008) is introduced for multidimensional consolidation problems with frictional contacts and the corresponding constitutive models (Pastor & Zienkiewicz, 1986) (Fu & Liu, 2011). An experimental methodology is presented for the laboratory test and material characterization (Castro 1969) (Bahda 1997) (Been & Jefferies 2006) using Hostun sands as reference hydraulic fill. A series of singular interaction shear tests for the interface calibration is included. Finally, a specific model algorithm for the solution of the set of differential equations governing the problem is presented. The process of consolidation and settlements involves a comprehensive simulation of the transient process of decantation and the build‐up of the silo effect in cells and certain phenomena related to self‐compaction and liquefaction. For this, an implementation of a 2D axi‐syimmetric coupled model with continuum and interface elements, aimed at simulating conditions and self‐weight consolidation of hydraulic fills once placed into floating caisson cells or close to retaining structures. This basically concerns a loose granular soil with a negligible initial effective stress level at the onset of the process. The implementation requires a specific numerical algorithm as well as specific constitutive models for both the continuum and the interface elements. The simulation of implementation procedures for the fills has required the modification of the algorithm so that a numerical representation of these procedures is carried out. A comparison of the results for the different procedures is interesting for the global analysis. Furthermore, the continuous updating of the model provides an insightful logging of variable profiles such as density, void ratio and solid fraction profiles, total and excess pore pressure, stresses and strains. This will lead to a better understanding of complex phenomena such as the transient gradient in lateral pressures due to silo effect in saturated soils. Interesting model and literature comparisons for the self‐weight consolidation (Fredlund, Donaldson, & Gitirana, 2009) and the silo effect results (Puertos del Estado (2006), EuroCode (2006), Japan Tech, Stands. (2009)). This study closes with the design of a decantation column prototype with frictional walls as the main future line of research.
Resumo:
La necesidad de desarrollar técnicas para predecir la respuesta vibroacústica de estructuras espaciales lia ido ganando importancia en los últimos años. Las técnicas numéricas existentes en la actualidad son capaces de predecir de forma fiable el comportamiento vibroacústico de sistemas con altas o bajas densidades modales. Sin embargo, ambos rangos no siempre solapan lo que hace que sea necesario el desarrollo de métodos específicos para este rango, conocido como densidad modal media. Es en este rango, conocido también como media frecuencia, donde se centra la presente Tesis doctoral, debido a la carencia de métodos específicos para el cálculo de la respuesta vibroacústica. Para las estructuras estudiadas en este trabajo, los mencionados rangos de baja y alta densidad modal se corresponden, en general, con los rangos de baja y alta frecuencia, respectivamente. Los métodos numéricos que permiten obtener la respuesta vibroacústica para estos rangos de frecuencia están bien especificados. Para el rango de baja frecuencia se emplean técnicas deterministas, como el método de los Elementos Finitos, mientras que, para el rango de alta frecuencia las técnicas estadísticas son más utilizadas, como el Análisis Estadístico de la Energía. En el rango de medias frecuencias ninguno de estos métodos numéricos puede ser usado con suficiente precisión y, como consecuencia -a falta de propuestas más específicas- se han desarrollado métodos híbridos que combinan el uso de métodos de baja y alta frecuencia, intentando que cada uno supla las deficiencias del otro en este rango medio. Este trabajo propone dos soluciones diferentes para resolver el problema de la media frecuencia. El primero de ellos, denominado SHFL (del inglés Subsystem based High Frequency Limit procedure), propone un procedimiento multihíbrido en el cuál cada subestructura del sistema completo se modela empleando una técnica numérica diferente, dependiendo del rango de frecuencias de estudio. Con este propósito se introduce el concepto de límite de alta frecuencia de una subestructura, que marca el límite a partir del cual dicha subestructura tiene una densidad modal lo suficientemente alta como para ser modelada utilizando Análisis Estadístico de la Energía. Si la frecuencia de análisis es menor que el límite de alta frecuencia de la subestructura, ésta se modela utilizando Elementos Finitos. Mediante este método, el rango de media frecuencia se puede definir de una forma precisa, estando comprendido entre el menor y el mayor de los límites de alta frecuencia de las subestructuras que componen el sistema completo. Los resultados obtenidos mediante la aplicación de este método evidencian una mejora en la continuidad de la respuesta vibroacústica, mostrando una transición suave entre los rangos de baja y alta frecuencia. El segundo método propuesto se denomina HS-CMS (del inglés Hybrid Substructuring method based on Component Mode Synthesis). Este método se basa en la clasificación de la base modal de las subestructuras en conjuntos de modos globales (que afectan a todo o a varias partes del sistema) o locales (que afectan a una única subestructura), utilizando un método de Síntesis Modal de Componentes. De este modo es posible situar espacialmente los modos del sistema completo y estudiar el comportamiento del mismo desde el punto de vista de las subestructuras. De nuevo se emplea el concepto de límite de alta frecuencia de una subestructura para realizar la clasificación global/local de los modos en la misma. Mediante dicha clasificación se derivan las ecuaciones globales del movimiento, gobernadas por los modos globales, y en las que la influencia del conjunto de modos locales se introduce mediante modificaciones en las mismas (en su matriz dinámica de rigidez y en el vector de fuerzas). Las ecuaciones locales se resuelven empleando Análisis Estadístico de Energías. Sin embargo, este último será un modelo híbrido, en el cual se introduce la potencia adicional aportada por la presencia de los modos globales. El método ha sido probado para el cálculo de la respuesta de estructuras sometidas tanto a cargas estructurales como acústicas. Ambos métodos han sido probados inicialmente en estructuras sencillas para establecer las bases e hipótesis de aplicación. Posteriormente, se han aplicado a estructuras espaciales, como satélites y reflectores de antenas, mostrando buenos resultados, como se concluye de la comparación de las simulaciones y los datos experimentales medidos en ensayos, tanto estructurales como acústicos. Este trabajo abre un amplio campo de investigación a partir del cual es posible obtener metodologías precisas y eficientes para reproducir el comportamiento vibroacústico de sistemas en el rango de la media frecuencia. ABSTRACT Over the last years an increasing need of novel prediction techniques for vibroacoustic analysis of space structures has arisen. Current numerical techniques arc able to predict with enough accuracy the vibro-acoustic behaviour of systems with low and high modal densities. However, space structures are, in general, very complex and they present a range of frequencies in which a mixed behaviour exist. In such cases, the full system is composed of some sub-structures which has low modal density, while others present high modal density. This frequency range is known as the mid-frequency range and to develop methods for accurately describe the vibro-acoustic response in this frequency range is the scope of this dissertation. For the structures under study, the aforementioned low and high modal densities correspond with the low and high frequency ranges, respectively. For the low frequency range, deterministic techniques as the Finite Element Method (FEM) are used while, for the high frequency range statistical techniques, as the Statistical Energy Analysis (SEA), arc considered as more appropriate. In the mid-frequency range, where a mixed vibro-acoustic behaviour is expected, any of these numerical method can not be used with enough confidence level. As a consequence, it is usual to obtain an undetermined gap between low and high frequencies in the vibro-acoustic response function. This dissertation proposes two different solutions to the mid-frequency range problem. The first one, named as The Subsystem based High Frequency Limit (SHFL) procedure, proposes a multi-hybrid procedure in which each sub-structure of the full system is modelled with the appropriate modelling technique, depending on the frequency of study. With this purpose, the concept of high frequency limit of a sub-structure is introduced, marking out the limit above which a substructure has enough modal density to be modelled by SEA. For a certain analysis frequency, if it is lower than the high frequency limit of the sub-structure, the sub-structure is modelled through FEM and, if the frequency of analysis is higher than the high frequency limit, the sub-structure is modelled by SEA. The procedure leads to a number of hybrid models required to cover the medium frequency range, which is defined as the frequency range between the lowest substructure high frequency limit and the highest one. Using this procedure, the mid-frequency range can be define specifically so that, as a consequence, an improvement in the continuity of the vibro-acoustic response function is achieved, closing the undetermined gap between the low and high frequency ranges. The second proposed mid-frequency solution is the Hybrid Sub-structuring method based on Component Mode Synthesis (HS-CMS). The method adopts a partition scheme based on classifying the system modal basis into global and local sets of modes. This classification is performed by using a Component Mode Synthesis, in particular a Craig-Bampton transformation, in order to express the system modal base into the modal bases associated with each sub-structure. Then, each sub-structure modal base is classified into global and local set, fist ones associated with the long wavelength motion and second ones with the short wavelength motion. The high frequency limit of each sub-structure is used as frequency frontier between both sets of modes. From this classification, the equations of motion associated with global modes are derived, which include the interaction of local modes by means of corrections in the dynamic stiffness matrix and the force vector of the global problem. The local equations of motion are solved through SEA, where again interactions with global modes arc included through the inclusion of an additional input power into the SEA model. The method has been tested for the calculation of the response function of structures subjected to structural and acoustic loads. Both methods have been firstly tested in simple structures to establish their basis and main characteristics. Methods are also verified in space structures, as satellites and antenna reflectors, providing good results as it is concluded from the comparison with experimental results obtained in both, acoustic and structural load tests. This dissertation opens a wide field of research through which further studies could be performed to obtain efficient and accurate methodologies to appropriately reproduce the vibro-acoustic behaviour of complex systems in the mid-frequency range.
Resumo:
Since the beginning of Internet, Internet Service Providers (ISP) have seen the need of giving to users? traffic different treatments defined by agree- ments between ISP and customers. This procedure, known as Quality of Service Management, has not much changed in the last years (DiffServ and Deep Pack-et Inspection have been the most chosen mechanisms). However, the incremen-tal growth of Internet users and services jointly with the application of recent Ma- chine Learning techniques, open up the possibility of going one step for-ward in the smart management of network traffic. In this paper, we first make a survey of current tools and techniques for QoS Management. Then we intro-duce clustering and classifying Machine Learning techniques for traffic charac-terization and the concept of Quality of Experience. Finally, with all these com-ponents, we present a brand new framework that will manage in a smart way Quality of Service in a telecom Big Data based scenario, both for mobile and fixed communications.
Resumo:
Underspanned suspension bridges are structures with important economical and aesthetic advantages, due to their high structural efficiency. However, road bridges of this typology are still uncommon because of limited knowledge about this structural system. In particular, there remains some uncertainty over the dynamic behaviour of these bridges, due to their extreme lightness. The vibrations produced by vehicles crossing the viaduct are one of the main concerns. In this work, traffic-induced dynamic effects on this kind of viaduct are addressed by means of vehicle-bridge dynamic interaction models. A finite element method is used for the structure, and multibody dynamic models for the vehicles, while interaction is represented by means of the penalty method. Road roughness is included in this model in such a way that the fact that profiles under left and right tyres are different, but not independent, is taken into account. In addition, free software {PRPgenerator) to generate these profiles is presented in this paper. The structural dynamic sensitivity of underspanned suspension bridges was found to be considerable, as well as the dynamic amplification factors and deck accelerations. It was also found that vehicle speed has a relevant influence on the results. In addition, the impact of bridge deformation on vehicle vibration was addressed, and the effect on the comfort of vehicle users was shown to be negligible.
Resumo:
In this paper a dynamic analysis of transnational shells is presented. The general linear shell theory is used in conjunction with additional shallow and curved plate approximations. In order to apply some type of extended Levy solution, the shell is assumed to be limited by a rectangular plan form, with two opposite edges simply supported (gable boundary conditions). First, the shells free vibrations are studied in the usual way, obtaining for each Fourier term the natural frequencies as solutions of a transcendental equation. However, solving these equations arises enormous computational difficulties. This paper deals specifically with this problem, trying to reduce its dimension by a discretization procedure. In the shell dynamic characteristics, namely the mass. The shell mass is lumped along a family of coordinate lines. Therefore, the natural frequencies for each harmonic term can be found from the solution of a typical matrix eigenvalues problem and standard numerical techniques can be applied. The shell response to forced vibrations, particularly to earthquake excitation, can be determined by using conventional procedure either in the time or in the frequency domain. Finally, extending the above procedure, any system of translational shells under dynamic loading can be studied. Then, by using matrix methods, a general computer program is written and applied to some illustrative examples. Numerical results has been obtained in two cases: circular cylindrical shell and box girder bridge.
Resumo:
In accordance with Russian, Kazakh and European building regulations, the deformation modulus of soil should be determined in the laboratory and also apply in situ soil tests on the stages of engineering geology prospecting. In this paper we present data on the determination and adjustment of the deformation characteristics at different stages of construction
Resumo:
This paper deals with the non-linear forced oscillations of axisymmetric long liquid bridges between equal disks. The dynamics of the liquid bridge has been analyzed by using a self-similar, one-dimensional model already used in similar problems. The influence of the dynamics on the static stability limits, as well as the main characteristics of the non-linear behaviour of long liquid bridges, have been studied with in the range of validity of the mathematical model used here.
Resumo:
Non-linear behavior of soils during a seismic event has a predominant role in current site response analysis. Soil response analysis consistently indicates that the stress-strain relationship of soils is nonlinear and shows hysteresis. When focusing in forced response simulations, time integrations based on modal analysis are widely considered, however parametric analysis, non-linear behavior and complex damping functions make difficult the online use of standard discretization strategies, e.g. those based on the use of finite element. In this paper we propose a new harmonic analysis formulation, able to address forced response simulation of soils exhibiting their characteristic nonlinear behavior. The solution can be evaluated in real-time from the offline construction of a parametric solution of the associated linearized problem within the Proper Generalized Decomposition framework.
Resumo:
El desarrollo da las nuevas tecnologías permite a los ingenieros llevar al límite el funcionamiento de los circuitos integrados (Integrated Circuits, IC). Las nuevas generaciones de procesadores, DSPs o FPGAs son capaces de procesar la información a una alta velocidad, con un alto consumo de energía, o esperar en modo de baja potencia con el mínimo consumo posible. Esta gran variación en el consumo de potencia y el corto tiempo necesario para cambiar de un nivel al otro, afecta a las especificaciones del Módulo de Regulador de Tensión (Voltage Regulated Module, VRM) que alimenta al IC. Además, las características adicionales obligatorias, tales como adaptación del nivel de tensión (Adaptive Voltage Positioning, AVP) y escalado dinámico de la tensión (Dynamic Voltage Scaling, DVS), imponen requisitos opuestas en el diseño de la etapa de potencia del VRM. Para poder soportar las altas variaciones de los escalones de carga, el condensador de filtro de salida del VRM se ha de sobredimensionar, penalizando la densidad de energía y el rendimiento durante la operación de DVS. Por tanto, las actuales tendencias de investigación se centran en mejorar la respuesta dinámica del VRM, mientras se reduce el tamaño del condensador de salida. La reducción del condensador de salida lleva a menor coste y una prolongación de la vida del sistema ya que se podría evitar el uso de condensadores voluminosos, normalmente implementados con condensadores OSCON. Una ventaja adicional es que reduciendo el condensador de salida, el DVS se puede realizar más rápido y con menor estrés de la etapa de potencia, ya que la cantidad de carga necesaria para cambiar la tensión de salida es menor. El comportamiento dinámico del sistema con un control lineal (Control Modo Tensión, VMC, o Control Corriente de Pico, Peak Current Mode Control, PCMC,…) está limitado por la frecuencia de conmutación del convertidor y por el tamaño del filtro de salida. La reducción del condensador de salida se puede lograr incrementando la frecuencia de conmutación, así como incrementando el ancho de banda del sistema, y/o aplicando controles avanzados no-lineales. Usando esos controles, las variables del estado se saturan para conseguir el nuevo régimen permanente en un tiempo mínimo, así como el filtro de salida, más específicamente la pendiente de la corriente de la bobina, define la respuesta de la tensión de salida. Por tanto, reduciendo la inductancia de la bobina de salida, la corriente de bobina llega más rápido al nuevo régimen permanente, por lo que una menor cantidad de carga es tomada del condensador de salida durante el tránsito. El inconveniente de esa propuesta es que el rendimiento del sistema es penalizado debido al incremento de pérdidas de conmutación y las corrientes RMS. Para conseguir tanto la reducción del condensador de salida como el alto rendimiento del sistema, mientras se satisfacen las estrictas especificaciones dinámicas, un convertidor multifase es adoptado como estándar para aplicaciones VRM. Para asegurar el reparto de las corrientes entre fases, el convertidor multifase se suele implementar con control de modo de corriente. Para superar la limitación impuesta por el filtro de salida, la segunda posibilidad para reducir el condensador de salida es aplicar alguna modificación topológica (Topologic modifications) de la etapa básica de potencia para incrementar la pendiente de la corriente de bobina y así reducir la duración de tránsito. Como el transitorio se ha reducido, una menor cantidad de carga es tomada del condensador de salida bajo el mismo escalón de la corriente de salida, con lo cual, el condensador de salida se puede reducir para lograr la misma desviación de la tensión de salida. La tercera posibilidad para reducir el condensador de salida del convertidor es introducir un camino auxiliar de energía (additional energy path, AEP) para compensar el desequilibrio de la carga del condensador de salida reduciendo consecuentemente la duración del transitorio y la desviación de la tensión de salida. De esta manera, durante el régimen permanente, el sistema tiene un alto rendimiento debido a que el convertidor principal con bajo ancho de banda es diseñado para trabajar con una frecuencia de conmutación moderada para conseguir requisitos estáticos. Por otro lado, el comportamiento dinámico durante los transitorios es determinado por el AEP con un alto ancho de banda. El AEP puede ser implementado como un camino resistivo, como regulador lineal (Linear regulator, LR) o como un convertidor conmutado. Las dos primeras implementaciones proveen un mayor ancho de banda, acosta del incremento de pérdidas durante el transitorio. Por otro lado, la implementación del convertidor computado presenta menor ancho de banda, limitado por la frecuencia de conmutación, aunque produce menores pérdidas comparado con las dos anteriores implementaciones. Dependiendo de la aplicación, la implementación y la estrategia de control del sistema, hay una variedad de soluciones propuestas en el Estado del Arte (State-of-the-Art, SoA), teniendo diferentes propiedades donde una solución ofrece más ventajas que las otras, pero también unas desventajas. En general, un sistema con AEP ideal debería tener las siguientes propiedades: 1. El impacto del AEP a las pérdidas del sistema debería ser mínimo. A lo largo de la operación, el AEP genera pérdidas adicionales, con lo cual, en el caso ideal, el AEP debería trabajar por un pequeño intervalo de tiempo, solo durante los tránsitos; la otra opción es tener el AEP constantemente activo pero, por la compensación del rizado de la corriente de bobina, se generan pérdidas innecesarias. 2. El AEP debería ser activado inmediatamente para minimizar la desviación de la tensión de salida. Para conseguir una activación casi instantánea, el sistema puede ser informado por la carga antes del escalón o el sistema puede observar la corriente del condensador de salida, debido a que es la primera variable del estado que actúa a la perturbación de la corriente de salida. De esa manera, el AEP es activado con casi cero error de la tensión de salida, logrando una menor desviación de la tensión de salida. 3. El AEP debería ser desactivado una vez que el nuevo régimen permanente es detectado para evitar los transitorios adicionales de establecimiento. La mayoría de las soluciones de SoA estiman la duración del transitorio, que puede provocar un transitorio adicional si la estimación no se ha hecho correctamente (por ejemplo, si la corriente de bobina del convertidor principal tiene un nivel superior o inferior al necesitado, el regulador lento del convertidor principal tiene que compensar esa diferencia una vez que el AEP es desactivado). Otras soluciones de SoA observan las variables de estado, asegurando que el sistema llegue al nuevo régimen permanente, o pueden ser informadas por la carga. 4. Durante el transitorio, como mínimo un subsistema, o bien el convertidor principal o el AEP, debería operar en el lazo cerrado. Implementando un sistema en el lazo cerrado, preferiblemente el subsistema AEP por su ancho de banda elevado, se incrementa la robustez del sistema a los parásitos. Además, el AEP puede operar con cualquier tipo de corriente de carga. Las soluciones que funcionan en el lazo abierto suelen preformar el control de balance de carga con mínimo tiempo, así reducen la duración del transitorio y tienen un impacto menor a las pérdidas del sistema. Por otro lado, esas soluciones demuestran una alta sensibilidad a las tolerancias y parásitos de los componentes. 5. El AEP debería inyectar la corriente a la salida en una manera controlada, así se reduce el riesgo de unas corrientes elevadas y potencialmente peligrosas y se incrementa la robustez del sistema bajo las perturbaciones de la tensión de entrada. Ese problema suele ser relacionado con los sistemas donde el AEP es implementado como un convertidor auxiliar. El convertidor auxiliar es diseñado para una potencia baja, con lo cual, los dispositivos elegidos son de baja corriente/potencia. Si la corriente no es controlada, bajo un pico de tensión de entrada provocada por otro parte del sistema (por ejemplo, otro convertidor conectado al mismo bus), se puede llegar a un pico en la corriente auxiliar que puede causar la perturbación de tensión de salida e incluso el fallo de los dispositivos del convertidor auxiliar. Sin embargo, cuando la corriente es controlada, usando control del pico de corriente o control con histéresis, la corriente auxiliar tiene el control con prealimentación (feed-forward) de tensión de entrada y la corriente es definida y limitada. Por otro lado, si la solución utiliza el control de balance de carga, el sistema puede actuar de forma deficiente si la tensión de entrada tiene un valor diferente del nominal, provocando que el AEP inyecta/toma más/menos carga que necesitada. 6. Escalabilidad del sistema a convertidores multifase. Como ya ha sido comentado anteriormente, para las aplicaciones VRM por la corriente de carga elevada, el convertidor principal suele ser implementado como multifase para distribuir las perdidas entre las fases y bajar el estrés térmico de los dispositivos. Para asegurar el reparto de las corrientes, normalmente un control de modo corriente es usado. Las soluciones de SoA que usan VMC son limitadas a la implementación con solo una fase. Esta tesis propone un nuevo método de control del flujo de energía por el AEP y el convertidor principal. El concepto propuesto se basa en la inyección controlada de la corriente auxiliar al nodo de salida donde la amplitud de la corriente es n-1 veces mayor que la corriente del condensador de salida con las direcciones apropiadas. De esta manera, el AEP genera un condensador virtual cuya capacidad es n veces mayor que el condensador físico y reduce la impedancia de salida. Como el concepto propuesto reduce la impedancia de salida usando el AEP, el concepto es llamado Output Impedance Correction Circuit (OICC) concept. El concepto se desarrolla para un convertidor tipo reductor síncrono multifase con control modo de corriente CMC (incluyendo e implementación con una fase) y puede operar con la tensión de salida constante o con AVP. Además, el concepto es extendido a un convertidor de una fase con control modo de tensión VMC. Durante la operación, el control de tensión de salida de convertidor principal y control de corriente del subsistema OICC están siempre cerrados, incrementando la robustez a las tolerancias de componentes y a los parásitos del cirquito y permitiendo que el sistema se pueda enfrentar a cualquier tipo de la corriente de carga. Según el método de control propuesto, el sistema se puede encontrar en dos estados: durante el régimen permanente, el sistema se encuentra en el estado Idle y el subsistema OICC esta desactivado. Por otro lado, durante el transitorio, el sistema se encuentra en estado Activo y el subsistema OICC está activado para reducir la impedancia de salida. El cambio entre los estados se hace de forma autónoma: el sistema entra en el estado Activo observando la corriente de condensador de salida y vuelve al estado Idle cunado el nuevo régimen permanente es detectado, observando las variables del estado. La validación del concepto OICC es hecha aplicándolo a un convertidor tipo reductor síncrono con dos fases y de 30W cuyo condensador de salida tiene capacidad de 140μF, mientras el factor de multiplicación n es 15, generando en el estado Activo el condensador virtual de 2.1mF. El subsistema OICC es implementado como un convertidor tipo reductor síncrono con PCMC. Comparando el funcionamiento del convertidor con y sin el OICC, los resultados demuestran que se ha logrado una reducción de la desviación de tensión de salida con factor 12, tanto con funcionamiento básico como con funcionamiento AVP. Además, los resultados son comparados con un prototipo de referencia que tiene la misma etapa de potencia y un condensador de salida físico de 2.1mF. Los resultados demuestran que los dos sistemas tienen el mismo comportamiento dinámico. Más aun, se ha cuantificado el impacto en las pérdidas del sistema operando bajo una corriente de carga pulsante y bajo DVS. Se demuestra que el sistema con OICC mejora el rendimiento del sistema, considerando las pérdidas cuando el sistema trabaja con la carga pulsante y con DVS. Por lo último, el condensador de salida de sistema con OICC es mucho más pequeño que el condensador de salida del convertidor de referencia, con lo cual, por usar el concepto OICC, la densidad de energía se incrementa. En resumen, las contribuciones principales de la tesis son: • El concepto propuesto de Output Impedance Correction Circuit (OICC), • El control a nivel de sistema basado en el método usado para cambiar los estados de operación, • La implementación del subsistema OICC en lazo cerrado conjunto con la implementación del convertidor principal, • La cuantificación de las perdidas dinámicas bajo la carga pulsante y bajo la operación DVS, y • La robustez del sistema bajo la variación del condensador de salida y bajo los escalones de carga consecutiva. ABSTRACT Development of new technologies allows engineers to push the performance of the integrated circuits to its limits. New generations of processors, DSPs or FPGAs are able to process information with high speed and high consumption or to wait in low power mode with minimum possible consumption. This huge variation in power consumption and the short time needed to change from one level to another, affect the specifications of the Voltage Regulated Module (VRM) that supplies the IC. Furthermore, additional mandatory features, such as Adaptive Voltage Positioning (AVP) and Dynamic Voltage Scaling (DVS), impose opposite trends on the design of the VRM power stage. In order to cope with high load-step amplitudes, the output capacitor of the VRM power stage output filter is drastically oversized, penalizing power density and the efficiency during the DVS operation. Therefore, the ongoing research trend is directed to improve the dynamic response of the VRM while reducing the size of the output capacitor. The output capacitor reduction leads to a smaller cost and longer life-time of the system since the big bulk capacitors, usually implemented with OSCON capacitors, may not be needed to achieve the desired dynamic behavior. An additional advantage is that, by reducing the output capacitance, dynamic voltage scaling (DVS) can be performed faster and with smaller stress on the power stage, since the needed amount of charge to change the output voltage is smaller. The dynamic behavior of the system with a linear control (Voltage mode control, VMC, Peak Current Mode Control, PCMC,…) is limited by the converter switching frequency and filter size. The reduction of the output capacitor can be achieved by increasing the switching frequency of the converter, thus increasing the bandwidth of the system, and/or by applying advanced non-linear controls. Applying nonlinear control, the system variables get saturated in order to reach the new steady-state in a minimum time, thus the output filter, more specifically the output inductor current slew-rate, determines the output voltage response. Therefore, by reducing the output inductor value, the inductor current reaches faster the new steady state, so a smaller amount of charge is taken from the output capacitor during the transient. The drawback of this approach is that the system efficiency is penalized due to increased switching losses and RMS currents. In order to achieve both the output capacitor reduction and high system efficiency, while satisfying strict dynamic specifications, a Multiphase converter system is adopted as a standard for VRM applications. In order to ensure the current sharing among the phases, the multiphase converter is usually implemented with current mode control. In order to overcome the limitation imposed by the output filter, the second possibility to reduce the output capacitor is to apply Topologic modifications of the basic power stage topology in order to increase the slew-rate of the inductor current and, therefore, reduce the transient duration. Since the transient is reduced, smaller amount of charge is taken from the output capacitor under the same load current, thus, the output capacitor can be reduced to achieve the same output voltage deviation. The third possibility to reduce the output capacitor of the converter is to introduce an additional energy path (AEP) to compensate the charge unbalance of the output capacitor, consequently reducing the transient time and output voltage deviation. Doing so, during the steady-state operation the system has high efficiency because the main low-bandwidth converter is designed to operate at moderate switching frequency, to meet the static requirements, whereas the dynamic behavior during the transients is determined by the high-bandwidth auxiliary energy path. The auxiliary energy path can be implemented as a resistive path, as a Linear regulator, LR, or as a switching converter. The first two implementations provide higher bandwidth, at the expense of increasing losses during the transient. On the other hand, the switching converter implementation presents lower bandwidth, limited by the auxiliary converter switching frequency, though it produces smaller losses compared to the two previous implementations. Depending on the application, the implementation and the control strategy of the system, there is a variety of proposed solutions in the State-of-the-Art (SoA), having different features where one solution offers some advantages over the others, but also some disadvantages. In general, an ideal additional energy path system should have the following features: 1. The impact on the system losses should be minimal. During its operation, the AEP generates additional losses, thus ideally, the AEP should operate for a short period of time, only when the transient is occurring; the other option is to have the AEP constantly on, but due to the inductor current ripple compensation at the output, unnecessary losses are generated. 2. The AEP should be activated nearly instantaneously to prevent bigger output voltage deviation. To achieve near instantaneous activation, the converter system can be informed by the load prior to the load-step or the system can observe the output capacitor current, which is the first system state variable that reacts on the load current perturbation. In this manner, the AEP is turned on with near zero output voltage error, providing smaller output voltage deviation. 3. The AEP should be deactivated once the new steady state is reached to avoid additional settling transients. Most of the SoA solutions estimate duration of the transient which may cause additional transient if the estimation is not performed correctly (e.g. if the main converter inductor current has higher or lower value than needed, the slow regulator of the main converter needs to compensate the difference after the AEP is deactivated). Other SoA solutions are observing state variables, ensuring that the system reaches the new steady state or they are informed by the load. 4. During the transient, at least one subsystem, either the main converter or the AEP, should be in closed-loop. Implementing a closed loop system, preferably the AEP subsystem, due its higher bandwidth, increases the robustness under system tolerances and circuit parasitic. In addition, the AEP can operate with any type of load. The solutions that operate in open loop usually perform minimum time charge balance control, thus reducing the transient length and minimizing the impact on the losses, however they are very sensitive to tolerances and parasitics. 5. The AEP should inject current at the output in a controlled manner, thus reducing the risk of high and potentially damaging currents and increasing robustness on the input voltage deviation. This issue is mainly related to the systems where AEP is implemented as auxiliary converter. The auxiliary converter is designed for small power and, as such, the MOSFETs are rated for small power/currents. If the current is not controlled, due to the some unpredicted spike in input voltage caused by some other part of the system (e.g. different converter), it may lead to a current spike in auxiliary current which will cause the perturbation of the output voltage and even failure of the switching components of auxiliary converter. In the case when the current is controlled, using peak CMC or Hysteretic Window CMC, the auxiliary converter has inherent feed-forwarding of the input voltage in current control and the current is defined and limited. Furthermore, if the solution employs charge balance control, the system may perform poorly if the input voltage has different value than the nominal, causing that AEP injects/extracts more/less charge than needed. 6. Scalability of the system to multiphase converters. As commented previously, in VRM applications, due to the high load currents, the main converters are implemented as multiphase to redistribute losses among the modules, lowering temperature stress of the components. To ensure the current sharing, usually a Current Mode Control (CMC) is employed. The SoA solutions that are implemented with VMC are limited to a single stage implementation. This thesis proposes a novel control method of the energy flow through the AEP and the main converter system. The proposed concept relays on a controlled injection of the auxiliary current at the output node where the instantaneous current value is n-1 times bigger than the output capacitor current with appropriate directions. Doing so, the AEP creates an equivalent n times bigger virtual capacitor at the output, thus reducing the output impedance. Due to the fact that the proposed concept reduces the output impedance using the AEP, it has been named the Output Impedance Correction Circuit (OICC) concept. The concept is developed for a multiphase CMC synchronous buck converter (including a single phase implementation), operating with a constant output voltage and with AVP feature. Further, it is extended to a single phase VMC synchronous buck converter. During the operation, the main converter voltage loop and the OICC subsystem capacitor current loop is constantly closed, increasing the robustness under system tolerances and circuit parasitic and allowing the system to operate with any load-current shape or pattern. According to the proposed control method, the system operates in two states: during the steady-state the system is in the Idle state and the OICC subsystem is deactivated, while during the load-step transient the system is in the Active state and the OICC subsystem is activated in order to reduce the output impedance. The state changes are performed autonomously: the system enters in the Active state by observing the output capacitor current and it returns back to the Idle state when the steady-state operation is detected by observing the state variables. The validation of the OICC concept has been done by applying it to a 30W two phase synchronous buck converter with 140μF output capacitor and with the multiplication factor n equal to 15, generating during the Active state equivalent output capacitor of 2.1mF. The OICC subsystem is implemented as single phase PCMC synchronous buck converter. Comparing the converter operation with and without the OICC the results demonstrate that the 12 times reduction of the output voltage deviation is achieved, for both basic operation and for the AVP operation. Furthermore, the results have been compared to a reference prototype which has the same power stage and a fiscal output capacitor of 2.1mF. The results show that the two systems have the same dynamic behavior. Moreover, an impact on the system losses under the pulsating load and DVS operation has been quantified and it has been demonstrated that the OICC system has improved the system efficiency, considering the losses when the system operates with the pulsating load and the DVS operation. Lastly, the output capacitor of the OICC system is much smaller than the reference design output capacitor, therefore, by applying the OICC concept the power density can be increased. In summary, the main contributions of the thesis are: • The proposed Output Impedance Correction Circuit (OICC) concept, • The system level control based on the used approach to change the states of operation, • The OICC subsystem closed-loop implementation, together with the main converter implementation, • The dynamic losses under the pulsating load and the DVS operation quantification, and • The system robustness on the capacitor impedance variation and consecutive load-steps.
Resumo:
La industria de la energía eólica marina ha crecido de forma significativa durante los últimos 15 años, y se espera que siga creciendo durante los siguientes. La construcción de torres en aguas cada vez más profundas y el aumento en potencia y tamaño de las turbinas han creado la necesidad de diseñar estructuras de soporte cada vez más fiables y optimizadas, lo que requiere un profundo conocimiento de su comportamiento. Este trabajo se centra en la respuesta dinámica de una turbina marina con cimentación tipo monopilote y sobre la que actúa la fuerza del viento. Se han realizado cálculos con distintas propiedades del suelo para cubrir un rango de rigideces que va desde una arena muy suelta a una muy densa. De este modo se ha analizado la influencia que tiene la rigidez del suelo en el comportamiento de la estructura. Se han llevado a cabo análisis estáticos y dinámicos en un modelo de elementos finitos implementado en Abaqus. El desplazamiento en la cabeza de la torre y la tensión en su base se han obtenido en función de la rigidez del suelo, y con ellos se ha calculado la amplificación dinámica producida cuando la frecuencia natural del sistema suelo‐cimentación torre se aproxima a la frecuencia de la carga. Dos diferentes enfoques a la hora de modelizar el suelo se han comparado: uno utilizando elementos continuos y otro utilizando muelles elásticos no lineales. Por último, un análisis de fiabilidad se ha llevado a cabo con un modelo analítico para calcular la probabilidad de resonancia del sistema, en el que se han considerado las propiedades de rigidez del suelo como variables aleatorias. Offshore wind energy industry has experienced a significant growth over the past 15 years, and it is expected to continue its growth in the coming years. The expansion to increasingly deep waters and the rise in power and size of the turbines have led to a need for more reliable and optimized support designs, which requires an extensive knowledge of the behaviour of these structures. This work focuses on the dynamic response of an offshore wind turbine founded on a monopile and subjected to wind loading. Different soil properties have been considered in order to cover the range of stiffness from a very loose to a very dense sand. In this way, the influence of stiffness on the structure behaviour has been assessed. Static and dynamic analyses have been carried out by means of a finite element model implemented in Abaqus. Head displacement and stress at the tower base have been obtained as functions of soil stiffness, and they have been used to calculate the dynamic amplification that is produced when the natural frequency of the system soil‐foundation‐tower approaches the load frequency. Two different approaches of soil modelling have been compared: soil modelled as a continuum and soil simulated with non linear elastic springs. Finally, a reliability analysis to assess the probability of resonance has been performed with an analytical model, in which soil stiffness properties are considered as stochastic variables.