788 resultados para Denture stomatitis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Statement of problem. A clinically significant incisal pin opening may occur after processing complete dentures if a compression molding technique is used. To recover the proper vertical dimension of occlusion, a time-consuming occlusal adjustment is necessary that often destroys the anatomy of the artificial teeth. A new injection molding process claims to produce dentures that require few, if any, occlusal adjustments in the laboratory after processing.Purpose. This laboratory study compared incisal pin opening, dimensional accuracy, and laboratory working time for dentures fabricated by this new injection system with dentures constructed by the conventional compression molding technique.Material and methods. Two groups of 6 maxillary and 6 mandibular dentures were evaluated as follows: group 1 (control), Lucitone 199, compression molded with a long cure cycle; and group 2, Lucitone 199, injection molded with a long cure. Incisal pin opening was measured with a micrometer immediately after deflasking. A computerized coordinate measuring machine was used to measure dimensional accuracy of 3-dimensional variations in selected positions of artificial teeth in 4 stages of denture fabrication. Analysis of variance (ANOVA) and t tests were performed to compare the groups.Results. A significant difference was found in pin opening between groups (t test). Horizontal dimensional changes evaluated with repeated measures ANOVA revealed no significant differences between groups. However, analysis of vertical dimensional changes disclosed significant differences between the groups. There was no appreciable difference in laboratory working time for flasking and molding denture bases between the injection and compression molding techniques when polymethyl methacrylate resin was used.Conclusion. The injection molding method produced a significantly smaller incisal pin opening over the standard compression molding technique. The injection molding technique, using polymethyl methacrylate, was a more accurate method for processing dentures. There were no appreciable differences in laboratory working time between the injection and compression molding techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This investigation evaluated the effectiveness of an infection control protocol for cleansing and disinfecting removable dental prostheses. Sixty-four dentures were rubbed with sterile cotton swab immediately after they had been taken from patients' mouths. Samples were individually placed in the culture medium and immediately incubated at 37 +/- 2 degreesC. The dentures were scrubbed for 1 min with 4% chlorhexidine, rinsed for 1 min in sterile water and placed for 10 min in one of the following immersion solutions: 4% chlorhexidine gluconate, 1% sodium hypochlorite, Biocide (iodophors) and Amosan (alkaline peroxide). After the disinfection procedures, the dentures were immersed in sterile water for 3 min, reswabbed and the samples were incubated. All samples obtained in the initial culture were contaminated with micro-organisms. All the lower dentures immersed in Biocide showed positive growth, and the upper dentures were positive for growth in six of eight dentures. The 4% chlorhexidine gluconate, 1% sodium hypochlorite and Amosan solutions have been proved effective to reduce the growth of the micro-organisms in the 10 min immersion period. The protocol evaluated in this study seems to be a viable method to prevent cross-contamination between dental personnel and patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aims of this study were to evaluate the reliability and to validate a Brazilian version of Oral Health Impact Profile for assessing edentulous subjects (OHIP-EDENT), an inventory for measuring oral health-related quality of life of edentulous subjects. The sample comprised 65 complete denture wearers (23 men, mean age of 69.1 +/- 10.3 years). The translated OHIP-EDENT was applied on two occasions with a washout period of 3 months. Reliability was assessed by an internal consistency analysis and a test-retest approach. A preliminary validation process was conducted by a qualitative approach/interview. Results of internal consistency showed a Cronbach's alpha of 0.86 or 0.90 for the first or second appointment respectively. Through the test-retest analysis, an intra-class correlation coefficient of 0.57 was found, and individual answers reflected a broad range of agreement. Interviewed volunteers (n = 6) comprehended most questions well. In conclusion, the Brazilian version of OHIP-EDENT is adequate for assessing the oral health-related quality of life for edentulous subjects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: the aim of this study was to compare the satisfaction and the quality of life in an elderly population using either mandibular conventional dentures or implant-retained overdentures.Materials and methods: A total of 34 patients were divided into two groups: group I-complete dentures users; group II - users of upper complete dentures opposed by implant-retained overdentures. The subjects were submitted to a questionnaire based on Oral Health impact Profile and oral health related quality of life to evaluate their satisfaction levels and quality of life with their prostheses. Data were evaluated using a non-parametric statistical analysis (Fischer test) with significant difference at alpha = 0.05.Results: There were no significant differences between the groups in relation to comfort, aesthetics, chewing ability, overall satisfaction, pain, functional, phonetic, social, and psychological limitations (p > 0.05). Comparing the stability of mandibular dentures, group II presented the better results (p < 0.05).Conclusion: Although the stability of the mandibular implant-retained overdenture was enhanced compared to a conventional denture, the quality of life and satisfaction levels were similar for both the groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the periodontal conditions of removable partial denture (RPD) wearers, comparing direct and indirect abutment teeth, and the teeth not involved in the denture design before denture placement and 1 year later. Fifty patients (32 women and 18 men), average age 45, were assessed by the same examiner at the moment of denture insertion and 3, 6, 9 and 12 months later. The following items were verified in each assessment: probing depth (PD), plaque index (PI) and gingival index (GI). PD and PI data were evaluated by ANOVA test for linear trend followed by Tukey-Kramer post-test, while GI data were analysed by Friedman's test. Results showed that the teeth not involved in the denture design were the least affected for all variables studied. It was also verified that PD and GI mean values increased from the initial assessment to 1 year of RPD wearing in every group, but that only PI showed a significant increase. This study indicated that direct and indirect retainer elements tend to undergo more damaging periodontal effects associated with RPD wearing when compared with non-abutment elements. Plaque index values were significantly higher after 1 year of denture use.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is a poor association between the dentist's evaluation of denture quality and patients' satisfaction with their dentures. Possible differences between dental professionals and patients' expectations might help explain differences in outcome evaluations. This study compared scores given by a dentist, a dental technician and patients for their expectations before and their final evaluation after complete dentures treatment. Twenty completely edentulous patients, a prosthodontist and a dental technician provided scores for the expected aesthetic and functional results of their dentures based on a visual analogue scale at baseline. Post-treatment completion ratings were given after adjustments, by dentist and patients. The dental technician provided post-treatment completion ratings after completing the dentures. The patients had higher expectations than the dental technician and the dentist perceived for both aesthetic and function (P < 0.001). The patients also presented higher post-treatment completion ratings than the dental professionals perceived for final aesthetics (P = 0.016, Kendall's W = 0.207). and function (P = 0.002, Kendall's W = 0.303). Only the dentist presented a statistically significant difference between expectations (lower) and final (higher) outcomes for aesthetics (P = 0.017) and function (P = 0.003). There was no correlation between expectations and post-treatment completion ratings according to the patients' age. There was also no correlation between the patients' gender and expectation scores. Patients presented higher expectations regarding their dentures than dental professionals. The dentist believed that dentures would bring fewer benefits than patients did, but his perception of denture benefits post-treatment was significantly higher than his expectations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors studied linear alterations processed on copper-aluminum casten MOD blocks, obtained from two expansion techniques (termic and hygroscopic by immersion). UNITERMS: Investment expansion. Thermic expansion. Hygroscopic expansion. Casten Technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors verified histologically in 20 no dentates patients, the influence of complete dentures on the hard palate mucosa. The patients were divided in two groups: I. Patients that never used complete dentures; II. Patients that were using complete dentures when this research was realized. New prosthesis were made for each one of the 20 patients. Immediately before they received the new prosthesis and ninety days after this, biopsies were realized. The circunferencial pieces of the hard palate mucosa were fixed in formol 10% and coloured with Hematoxylin/Eosin and Mallory's Tricomic for histomorphologic analysis and measuring of the stratum corneum of the epithelium. It was made the statistical analysis and the results showed that: 1. In normal conditions, the utilization of the full dentures produces the reduce of the thickness of the stratum corneum. This was more observed in Group I. 2. The range difference of the thickness of the stratum corneum between the first and the second biopsies in the groups I and II (4.86 microns and 2.18 microns) were not statistically significant. 3. With the use of complete dentures the stratum corneum of the epithelium showed tendence to parakeratinization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Being the surface roughness a fundamental property in the fit of the castings, it was determined the roughness of 5 high-copper casting alloys, according to the heating over their melting temperature. That way, the specimens made with smooth plastic in the shape of a rectangular plate, 2 mm x 7 mm x 11 mm were invested into a cristobalite investment. After heating and elimination on the plastic, the molds were filled by 3 g of molten alloy, casted in a electrical casting machine at the casting temperature at 25 degrees C and 50 degrees C overheating. The surface roughness was measured in a roughness analyser, Talysurf. As a result, it was verified that there is a variation of surface roughness among the alloys tested, and the heating of the alloys until 50 degrees C over the melting temperature does not interfere in the roughness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It was evaluated the castability of four copper-aluminium alloy according the melting casting method used. The specimens were made using polyester mesh screen, with 11 x 11 filaments of 0.26 mm thick, fixed along of two adjacent edges in wax bar, with the sprue attached at their junction. The alloys were in an electrical casting machine and a centrifugal casting machine with an air/gas torch. The castability values were obtained by the percentage of completed segments of the resulting cast alloy screen. It was verified that the use of the electrical casting machine produced higher castability values to the copper-aluminium alloys than those produced by a centrifugal casting machine with an air/gas torch.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It was evaluated the Vickers hardness of five high-copper casting alloys, in their original package form and after casting, according to the casting method used. That way, ten ingots, supplied by the manufacturers of each alloy, were included in self-curing acrylic resin, polished, numerated and submitted to Vickers hardness test at load of 200 g during 30 seconds. Afterwards the numerated ingots were removed from the acrylic resin and five of those were cast in an electrical casting machine and the other five in a centrifugal casting machine with an air/gas torch. The specimens obtained were included in self-curing acrylic resin, polished and submitted to Vickers hardness test. As a result it was verified that there is a variation of hardness among the alloys tested, and the use of the electrical casting machine produced lower hardness values than those produced when used the centrifugal casting machine with an air/gas torch. Also, there is a decrease of hardness of the cast alloys when they are tested in their original form and after casting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors analysed the simultaneous effects of the dimensional and weight alteration of resins utilized for esthetic facets submitted to warehousing conditions and periods of time. The resins showed different behaviour and a neat correlation between dimensional alteration and weight. The condition of immersion promoted dimensional alteration 50% lower and an alteration of weight three times higher.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to compare the enamel/resin/metal bond tensile strength by using human canines, in which castings were bonded. These castings were obtained by Co-Cr or Ni-Cr alloys and showed four types of mechanisms of retention: 50 micrograms aluminum oxide abrasive, electrochemical etch, acrylic beads metal mesh. The castings were bonded utilizing Comspan Opaque and Panavia Ex. The specimens were subjected to tensile forces after 24 hours in an Instron machine. The castings subjected to 50 micrograms aluminum oxide abrasive and bonded utilizing Panavia EX showed the biggest bond tensile strength.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors looked for the verification of the fatigue of retentive clasps utilized on the removable partial denture. According to this, it was idealized and built on assay machine, that through movements, simulate the insertion and removal of the clasp for a pattern tooth, manufactured on cobalt-chromium which has all the preparation normally utilized to the correct confection of this type of prosthesis. It was utilized three different commercial alloys based on cobalt-chromium: L1-Biosil; L2-Steldent; L3-Duracron. It was utilized the T clasp of Roach, with was tested upon three different proportions among width and thickness: E1-1.7;E2-2.0 and E3-2.3 and was casted through two casting techniques: F1-oxygen-gas and F2-oxygen-acetylene. The clasps were tested on the machine, which allowed the reading of the number of insertion and removal cycles made until fatigue appeared. The obtained results were submitted to the statistic analysis and the authors concluded that: a) L3 (Duracrom) obtained the best results followed by L1 (Biosil) and finally L3 (Steldent); b) among the analyzed thickness, the best results were obtained by E3, followed by E2 and after this E1; c) form the casting techniques, F2 gave us the best results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors tested the T clasp of Roach in three differents proportions among width and thickness: E1-1.7; E2-2.0 and E3-2.3, with a constant length of 15 mm. These clasps were casted with three cobalt-chromium alloys (L1-Biosil; L2-Steldent and L3-Duracrom), through two casting techniques (F1-oxygen-gas and F2-oxygen-acetylene). The fatigue of the clasps were verified by using and assay machine, that through movements, simulate the insertion and removal of the clasps for a pattern which were obtained from a premolar, prepared in a surveyor. This machine detect the fatigue of the clasps and count the number of cycles of insertion and removal realized. The obtained results of the interaction between the analysed factors, were submitted to the statistic analysis and the authors concluded that: a) the interaction of factors, Alloy x Thickness, Alloy x Casting Technique and Thickness x Casting Technique did not change the order of effects that the factors showed separately but gave rise to effects of different magnitude for any observed sense; b) the simultaneous interaction of the factors Alloy x Thickness x Casting Technique confirmed the superiority of the L3 alloy, the thickness E3 and the F2 casting technique.