This paper describes the development of a methodology for solid phase extraction (SPE) and pre-concentration of nitrosamines from aqueous samples using granular activated charcoal as stationary phase. micelar electrokinetic capillary Chromatography (MEKC) was used for the separation and identification of the nitrosamines in the extracts. Using a sample with 50 µg l-1 of each nitrosamines standards (dimethylnitrosamine, DMN; diethylnitrosamine, DEN; N-nitrosopyrrolidine, NPYR; N-nitrosopiperidine, NPIP; N-nitrosomorpholine, NMOR), the methodology showed a range of recuperation from 29 to 107% with a linear zone between 10 and 500 µg l-1. The developed methodology can be applicable to the determination of these analytes in different aqueous samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work a polyurethane polymer derived from castor oil was used as stationary phase for capillary gas chromatography. The polymer was obtained by reaction of hydroxylated compound and isocynate (NCO), forming urethane. Columns of 7 m x 0,25 mm were then coated with this stationary phase (film thickness of 0,25 µm) using static coating method. The Grob test was also performed. Samples of essential oil of the Aniba duckei Korstermans was then analysed in POLYH4-MD capillary column in order to evaluate its chromatographic perfomance. The linalool was found to be the major component and has been used as compound of departure for many important syntheses. Results show that the experimental columns give higher resolution and can be employed for analysis of essentials oils.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes a novel approach to the separation of fatty acids ranging from 8 to 20 carbons using capillary electrophoresis with contactless conductivity detection. Complete separation of nine linear chain fatty acids (from C8:0 to C20:0) was achieved in 15 min under normal polarity operation. Limits of detection ranged from 35 to 319 µmol L-1 for C20:0 to C8:0, respectively. The optimized running electrolyte composition was 5.0 mmol L-1 phosphate buffer at pH 7, 4.0 mmol L-1 dimethyl-b-cyclodextrin, 2.0 mmol L-1 trimethyl-b-cyclodextrin, acetonitrile 50% (v/v), and methanol 20% (v/v). The applicability of the separation system was demonstrated by the analysis of coconut vegetable oil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present work was to test the combination of non-esterified fatty acid (NEFA) isolation using fumed silicon dioxide with capillary gas-chromatography (C-GC) with splitless injection for the analysis of NEFAs in human plasma. Injection volume, solvent re-condensation and split purge flow-rate were the parameters evaluated for the analysis of fatty acid methyl esters by C-GC. The use of a solvent re-condensation technique, associated with 1.0 µL injection and a split purge flow rate of 80 mL/min resulted in satisfactory analysis of NEFAs. Fourteen fatty acids were identified in plasma samples, ranging from 2.03 to 184.0 µmol/L. The combination of both techniques proved useful for routine analyses of plasma NEFAs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The demand for analytical methods suitable for accurate and reproducible determination of drug enantiomers has increased significantly in the last years. High-performance liquid chromatography (HPLC) using chiral stationary phases and capillary electrophoresis (CE) are the most important techniques used for this purpose. In this paper, the fundamental aspects of chiral separations using both techniques are presented. Some important aspects for the development of enantioselective methods, particularly for the analysis of drugs and metabolites in biological samples, are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new construction of a capillary electrophoresis instrument with a universal conductivity detector (oscillometric detector) is described. The performance of the electrophoresis equipment was evaluated through the separation and detection of inorganic anions and cations in aqueous solutions. The results reproduced those found in the literature for the investigated probe ions, showing an efficient separation and good repeatability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports the analysis of inorganic and organic contaminants in alcohol fuel samples using capillary electrophoresis. Chloride and sulfate were analyzed in nitrate/ monochloroacetic acid at 10 mmol L-1 concentration each under indirect UV detection (210 nm). The analysis of aldehydes is based on the 216 nm detection of 3-methyl-2-benzothiazoline hydrazone adducts. The running buffer consisted of 20 mmol L-1 tetraborate , 40 mmol L-1 sodium dodecyl sufate and 12 mmol L-1 beta-ciclodextrin. Both methodologies were applied to real samples indicating inorganic ion concentrations from 0.15 to 6.64 mg kg-1 and aldehydes from 32.0 to 91.3 mg L-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes the use of a conventional CRT monitor as a high voltage power supply for capillary electrophoresis. With this monitor, a 23-kV high voltage with a ripple of 1.32% was observed. The reproducibility of the applied high voltage was evaluated by measuring the standard deviations of peak area and migration time for five consecutive injections of a test mixture containing potassium, sodium, and lithium cations at 50 mmol L-1. The errors were about 2.5% and 0.6% for peak area and migration time, respectively. The maximum current tested was about 180 mA, which covers most capillary electrophoresis applications. This system has been successfully used for several months, maintaining the desired level of performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We studied the transesterification of two vegetable oils: soybean and waste frying oil. The main problem of transesterification is related to the measurement of the ethyl ester content. In this work we used a quick analytical method for assessing the ethyl ester fraction of the purified fuel-grade transesterification products by applying a simple correlation with density. If the ester content is higher than 85% by weight the correlation allows the determination by a single density measurement. This method is suitable for control and determines the ethyl ester quickly and simply.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Els processos per a l’aprovació i la implementació de la Llei per a l’Autonomia personal i l’Atenció a les Persones en situació de Dependència (LAPAD) han donat lloc a un intens debat polític i social que, coincidint també amb les millores en la provisió de serveis i els avenços mèdics, ha contribuït a un procés de classificació i d’etiquetatge basats en els dèficits de les persones que es troben en aquestes circumstàncies. Aquesta visió anul·la el subjecte i la seva experiència singular i condiciona l’abordatge dels models d’atenció i de cura. L’estudi pretén fer una aproximació a les persones grans amb pèrdua d’autonomia funcional, fent emergir les seves veus, que expressen com perceben, interpreten, afronten i es reajusten a la nova situació. Partint d’un enfocament constructivista, basat en la subjectivitat, es fa un recorregut sobre els models de la discapacitat que han reeixit en l’activitat científica dels darrers anys, els mecanismes de regulació de les pèrdues que defensen les teories del cicle vital i les aportacions que s’han fet sobre el model de la resiliència aplicat a les persones que envelleixen. El resultats de l’estudi mostren com les representacions i els significats que les persones grans atribueixen a la seva experiència s’inscriuen en les seves trajectòries vitals, donant un sentit únic i singular a la forma de viure i de respondre a la pèrdua d’autonomia funcional i les seves conseqüències. Aquelles que expressen una vivència d’integritat respecte de la vida viscuda, amb predomini d’afectes positius envers un mateix i els altres, que conserven l’esperança i el desig de continuar vivint, s’ajusten a les pèrdues de manera més satisfactòria que aquelles que expressen desconfiança i una certa amargor respecte de la pròpia vida. D’això se’n deriva que els espais d’escolta i d’acompanyament poden ser un recurs vàlid i necessari en el qual, a través de la paraula i el testimoni narrat, el subjecte pugui repensar i resignificar les seves experiències.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mediante la aplicación de ortesis de silicona, hemos podido reducir y tratar diversas patologías metatarsales de etiologfa biomecánica. Presentamos varios casos clínicos a los cuales mediante la instauración de estos tratamientos ortopodológicos, logramos establecer el comportamiento dinámico del antepié, y reducir las lesiones de partes blandas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CE-MS has been increasingly used for analysis of a vast array of compounds. This article reviews the different electrophoretic modes, interfaces and mass analyzers that are commonly used in the CE-MS coupling, as well as the technique advantages and performance characteristics. A large compilation of CE-MS applications is also presented. Therefore, this review is both a guide for beginners and a collection of key references for people who are familiar to the technique. Furthermore, this is the first CE-MS review published in a Brazilian journal and marks the installation of the first two commercial CE-MS units in Sao Paulo State.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Capillary electrochromatography (CEC) is a separation technique in which the mobile phase flow is based on the application of a voltage across a packed capillary, which generates an electroosmotic flow that transports the analytes along the capillary toward the detector. As it combines the separation mechanisms of high-performance liquid chromatography (HPLC) and of capillary electrophoresis (CE), CEC can be considered a hybrid of HPLC and CE. This review presents some fundamental aspects of CEC and is focused on the instrumental advances of the technique, such as column technology, operation modes and detection systems, presenting recent papers on these topics and some applications and perspectives about CEC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the design and tests of a set-up mounted in a conventional double beam spectrophotometer, which allows the determination of optical density of samples confined in a long liquid core waveguide (LCW) capillary. Very long optical path length can be achieved with capillary cell, allowing measurements of samples with very low optical densities. The device uses a custom optical concentrator optically coupled to LCW (TEFLON® AF). Optical density measurements, carried out using a LCW of ~ 45 cm, were in accordance with the Beer-Lambert Law. Thus, it was possible to analyze quantitatively samples at concentrations 45 fold lower than that regularly used in spectrophotometric measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The importance of chitosan has grown significantly over the last two decades due to its renewable and biodegradable source, and also because of the recent increase in the knowledge of its functionality in the technological and biomedical applications. The present article reviews the biopolymer chitosan and its derivatives as versatile biomaterials for potential drug delivery systems, as well as tissue engineering applications, analgesia and treatment of arthritis.