993 resultados para DENSITY-STRATIFIED FLUID


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dot enzyme-linked immunosorbent assay (DOT-ELISA) was developed to detect specific antibodies in cerebrospinal fluid (CSF) for human neurocysticercosis immunodiagnosis, with Cysticercus cellulosae antigen dotted on a new solid-phase. This was represented by sheets of a synthetic polyester fabric impregnated with a polymerized resin (N-methylol-acrylamide). A very stable preparation was thus obtained, the antigen being covalently bound by cross-linking with free N-methylol groups on the resin. Since robust, no special care was necessary for handling the solid-phase. The test could be performed at room-temperature. From 30 CSF samples assayed, 14 were positive, from a group of 15 cases of neurocysticercosis, with titers from 1 to 128; 15 other samples, from normals or other neurological diseases, were all negative. Test characteristics seem to indicate it as adequate for epidemiological surveys. A more detailed study on sensitivity, specificity, reproducibility and the use in serum samples is being conducted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design of magnetic cores can be carried out by taking into account the optimization of different parameters in accordance with the application requirements. Considering the specifications of the fast field cycling nuclear magnetic resonance (FFC-NMR) technique, the magnetic flux density distribution, at the sample insertion volume, is one of the core parameters that needs to be evaluated. Recently, it has been shown that the FFC-NMR magnets can be built on the basis of solenoid coils with ferromagnetic cores. Since this type of apparatus requires magnets with high magnetic flux density uniformity, a new type of magnet using a ferromagnetic core, copper coils, and superconducting blocks was designed with improved magnetic flux density distribution. In this paper, the designing aspects of the magnet are described and discussed with emphasis on the improvement of the magnetic flux density homogeneity (Delta B/B-0) in the air gap. The magnetic flux density distribution is analyzed based on 3-D simulations and NMR experimental results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the help of a unique combination of density functional theory and computer simulations, we discover two possible scenarios, depending on concentration, for the hierarchical self-assembly of magnetic nanoparticles on cooling. We show that typically considered low temperature clusters, i.e. defect-free chains and rings, merge into more complex branched structures through only three types of defects: four-way X junctions, three-way Y junctions and two-way Z junctions. Our accurate calculations reveal the predominance of weakly magnetically responsive rings cross-linked by X defects at the lowest temperatures. We thus provide a strategy to fine-tune magnetic and thermodynamic responses of magnetic nanocolloids to be used in medical and microfluidics applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The specificity and sensitivity of the enzyme immunoassay (EIA), presently used in South America areas where hydatidosis caused by Echinococcus granulosus is endemic, was compared to two alternative EIA. One of these uses an hydatid antigen of different prepraration and the other vesicular fluid of Taenia crassiceps cisticerci (VFCC). The effect of previous neutralization in the serum sample of antibodies anti-normal ovine or murine sera and anti-phosphorylcholine on the diagnostic efficiency of these EIA was studied. The frequency of distribution of the titers obtained with normal sera, hydatid sera positive to DD5 test and hydatid sera negative to DD5 test in three EIA systems was analyzed. Results showed a significant decrease of sensitivity of the EIA using VFCC when compared to these EIA using hydatid antigens. This makes inconvenient the use of VFCC for the immunodiagnosis of hydatid disease. No significant differences between the two EIA using hydatid antigens were observed. SDS-PAGE analysis showed remarkable differences between the VFCC and the hydatid antigens composition and some differences among these latters probably due to manufacturing procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the liquid-vapor interface of a model of patchy colloids. This model consists of hard spheres decorated with short-ranged attractive sites ("patches") of different types on their surfaces. We focus on a one-component fluid with two patches of type A and nine patches of type B (2A9B colloids), which has been found to exhibit reentrant liquid-vapor coexistence curves and very low-density liquid phases. We have used the density-functional theory form of Wertheim's first-order perturbation theory of association, as implemented by Yu and Wu [J. Chem. Phys. 116, 7094 (2002)], to calculate the surface tension, and the density and degree of association profiles, at the liquid-vapor interface of our model. In reentrant systems, where AB bonds dominate, an unusual thickening of the interface is observed at low temperatures. Furthermore, the surface tension versus temperature curve reaches a maximum, in agreement with Bernardino and Telo da Gama's mesoscopic Landau-Safran theory [Phys. Rev. Lett. 109, 116103 (2012)]. If BB attractions are also present, competition between AB and BB bonds gradually restores the monotonic temperature dependence of the surface tension. Lastly, the interface is "hairy," i.e., it contains a region where the average chain length is close to that in the bulk liquid, but where the density is that of the vapor. Sufficiently strong BB attractions remove these features, and the system reverts to the behavior seen in atomic fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper reports viscosity measurements of compressed liquid dipropyl (DPA) and dibutyl (DBA) adipates obtained with two vibrating wire sensors developed in our group. The vibrating wire instruments were operated in the forced oscillation, or steady-state mode. The viscosity measurements of DPA were carried out in a range of pressures up to 18. MPa and temperatures from (303 to 333). K, and DBA up to 65. MPa and temperature from (303 to 373). K, covering a total range of viscosities from (1.3 to 8.3). mPa. s. The required density data of the liquid samples were obtained in our laboratory using an Anton Paar vibrating tube densimeter and were reported in a previous paper. The viscosity results were correlated with density, using a modified hard-spheres scheme. The root mean square deviation of the data from the correlation is less than (0.21 and 0.32)% and the maximum absolute relative deviations are within (0.43 and 0.81)%, for DPA and DBA respectively. No data for the viscosity of both adipates could be found in the literature. Independent viscosity measurements were also performed, at atmospheric pressure, using an Ubbelohde capillary in order to compare with the vibrating wire results. The expanded uncertainty of these results is estimated as ±1.5% at a 95% confidence level. The two data sets agree within the uncertainty of both methods. © 2015 Published by Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

33rd IAHR Congress: Water Engineering for a Sustainable Environment

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Present paper present the main results obtained in the scope of an ongoing project which aims to contribute to the valorization of a waste generated by the Portuguese oil company in construction materials. This waste is an aluminosilicate with high pozzolanic reactivity. Several different technological applications had already been tested with success both in terms of properties and compliance with the corresponding standards specifications. Namely, this project results already demonstrated that this waste can be used in traditional concrete, self-compacted concrete, mortars (renders, masonry mortar, concrete repair mortars), cement main constituent as well as alkali activated binders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Mammography is considered the best imaging technique for breast cancer screening, and the radiographer plays an important role in its performance. Therefore, continuing education is critical to improving the performance of these professionals and thus providing better health care services. Objective: Our goal was to develop an e-learning course on breast imaging for radiographers, assessing its efficacy , effectiveness, and user satisfaction. Methods: A stratified randomized controlled trial was performed with radiographers and radiology students who already had mammography training, using pre- and post-knowledge tests, and satisfaction questionnaires. The primary outcome was the improvement in test results (percentage of correct answers), using intention-to-treat and per-protocol analysis. Results: A total of 54 participants were assigned to the intervention (20 students plus 34 radiographers) with 53 controls (19+34). The intervention was completed by 40 participants (11+29), with 4 (2+2) discontinued interventions, and 10 (7+3) lost to follow-up. Differences in the primary outcome were found between intervention and control: 21 versus 4 percentage points (pp), P<.001. Stratified analysis showed effect in radiographers (23 pp vs 4 pp; P=.004) but was unclear in students (18 pp vs 5 pp; P=.098). Nonetheless, differences in students’ posttest results were found (88% vs 63%; P=.003), which were absent in pretest (63% vs 63%; P=.106). The per-protocol analysis showed a higher effect (26 pp vs 2 pp; P<.001), both in students (25 pp vs 3 pp; P=.004) and radiographers (27 pp vs 2 pp; P<.001). Overall, 85% were satisfied with the course, and 88% considered it successful. Conclusions: This e-learning course is effective, especially for radiographers, which highlights the need for continuing education.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A correlation and predictive scheme for the viscosity and self-diffusivity of liquid dialkyl adipates is presented. The scheme is based on the kinetic theory for dense hard-sphere fluids, applied to the van der Waals model of a liquid to predict the transport properties. A "universal" curve for a dimensionless viscosity of dialkyl adipates was obtained using recently published experimental viscosity and density data of compressed liquid dimethyl (DMA), dipropyl (DPA), and dibutyl (DBA) adipates. The experimental data are described by the correlation scheme with a root-mean-square deviation of +/- 0.34 %. The parameters describing the temperature dependence of the characteristic volume, V-0, and the roughness parameter, R-eta, for each adipate are well correlated with one single molecular parameter. Recently published experimental self-diffusion coefficients of the same set of liquid dialkyl adipates at atmospheric pressure were correlated using the characteristic volumes obtained from the viscosity data. The roughness factors, R-D, are well correlated with the same single molecular parameter found for viscosity. The root-mean-square deviation of the data from the correlation is less than 1.07 %. Tests are presented in order to assess the capability of the correlation scheme to estimate the viscosity of compressed liquid diethyl adipate (DEA) in a range of temperatures and pressures by comparison with literature data and of its self-diffusivity at atmospheric pressure in a range of temperatures. It is noteworthy that no data for DEA were used to build the correlation scheme. The deviations encountered between predicted and experimental data for the viscosity and self-diffusivity do not exceed 2.0 % and 2.2 %, respectively, which are commensurate with the estimated experimental measurement uncertainty, in both cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cerebrospinal fluid (CSF) samples from 2083 patients with acquired immunodeficiency syndrome (AIDS) and neurological complications were bacteriologically examined during a period of 7 years (1984-1990). The percentage of patients who had at least one bacterial agent cultured from the CSF was 6.2%. Mycobacterium tuberculosis was the most frequently isolated agent (4.3%), followed by Mycobacterium avium complex or MAC (0.7%), Pseudomonas spp (0.5%), Enterobacter spp (0.4%), and Staphylococcus aureus (0.3%). Among 130 culture positive patients, 89 (68.5%) had M. tuberculosis and 15 (11.6%) had MAC. The frequency of bacterial isolations increased from 1988 (5.2%) to 1990 (7.2%), partly due to the increase in MAC isolations. Bacterial agents were more frequently isolated from patients in the age group 21-30 years and from women (p<0.05).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dot-enzyme-linked immunosorbent assay (Dot-ELISA) for pneumococcal antigen detection was standardized in view of the need for a rapid and accurate immunodiagnosis of acute pneumococcal pneumonia. A total of 442 pleural fluid effusion samples (PFES) from children with clinical and laboratory diagnoses of acute bacterial pneumonia, plus 38 control PFES from tuberculosis patients and 20 negative control serum samples from healthy children were evaluated by Dot-ELISA. The samples were previously treated with 0.1 M EDTA pH 7.5 at 90°C for 10 min and dotted on nitrocellulose membrane. Pneumococcal omniserum diluted at 1:200 was employed in this assay for antigen detection. When compared with standard bacterial culture, counterimmunoelectrophoresis and latex agglutination techniques, the Dot-ELISA results showed relative indices of 0.940 to sensitivity, 0.830 to specificity and 0.760 to agreement. Pneumococcal omniserum proved to be an optimal polyvalent antiserum for the detection of pneumococcal antigen by Dot-ELISA. Dot-ELISA proved to be a practical alternative technique for the diagnosis of pneumococcal pneumonia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mycobacterium avium complex (MAC) is frequently isolated from patients with late complications of Acquired Immunodeficiency Syndrome (AIDS), especially in North America and Europe. However, its isolation from the central nervous system (CNS) has been seldom reported in these countries. MAC infections in AIDS patients in African and Latin American countries are believed to be uncommon. We report the isolation of MAC from cerebrospinal fluid (CSF) of 11 AIDS patients out of 1723 (0.63%) seen at "Centro de Referência e Treinamento - AIDS", São Paulo and discuss the significance of its isolation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eighty purulent cerebrospinal fluid (CSF) samples from patients with clinical evidence of meningitis were studied using the Directigen latex agglutination (LA) kit to determine the presence of bacterial antigen in CSF. The results showed a better diagnostic performance of the LA test than bacterioscopy by Gram stain, culture and counterimmunoelectrophoresis (CIE), as far as Neisseria meningitidis groups B and C, and Haemophilus influenzae type b are concerned, and a better performance than bacterioscopy and culture considering Streptococcus pneumoniae. Comparison of the results with those of culture showed that the LA test had the highest sensitivity for the Neisseria meningitidis group C. Comparing the results with those of CIE, the highest levels of sensitivity were detected for N. meningitidis groups B and C. Regarding specificity, fair values were obtained for all organisms tested. The degree of K agreement when the LA test was compared with CIE exhibited better K indices of agreement for N. meningitidis groups B and C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ORF strain of Cysticercus longicollis represents an important model for the study of heterologous antigens in the immunodiagnosis of neurocysticercosis (NC). The immunoperoxidase (IP) technique was standardized using a particulate antigen suspension of Cysticercus longicollis (Cl) and Cysticercus cellulosae (Cc). Cerebrospinal fluid (CSF) samples were incubated on the antigen fixed to microscopy slides; the conjugate employed was anti-IgG-peroxidase and the enzymatic reaction was started by covering the slides with chromogen solution (diaminobenzidine/H2O2). After washing with distilled water, the slide was stained with 2% malachite green in water. Of the CSF samples from 21 patients with NC, 19 (90.5%) were positive, whereas the 8 CSF samples from the control group (100%) were negative. The results of the IP-Cl test applied to 127 CSF samples from patients with suspected NC showed 28.3% reactivity as opposed to 29.1 % for the IP-Cc test. The agreement index for the IP test (Cl x Cc) was 94.2%, with no significant difference between the two antigens.