989 resultados para Correlation Spectroscopy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infrared spectroscopy, either in the near and mid (NIR/MIR) region of the spectra, has gained great acceptance in the industry for bioprocess monitoring according to Process Analytical Technology, due to its rapid, economic, high sensitivity mode of application and versatility. Due to the relevance of cyprosin (mostly for dairy industry), and as NIR and MIR spectroscopy presents specific characteristics that ultimately may complement each other, in the present work these techniques were compared to monitor and characterize by in situ and by at-line high-throughput analysis, respectively, recombinant cyprosin production by Saccharomyces cerevisiae. Partial least-square regression models, relating NIR and MIR-spectral features with biomass, cyprosin activity, specific activity, glucose, galactose, ethanol and acetate concentration were developed, all presenting, in general, high regression coefficients and low prediction errors. In the case of biomass and glucose slight better models were achieved by in situ NIR spectroscopic analysis, while for cyprosin activity and specific activity slight better models were achieved by at-line MIR spectroscopic analysis. Therefore both techniques enabled to monitor the highly dynamic cyprosin production bioprocess, promoting by this way more efficient platforms for the bioprocess optimization and control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous work by our group introduced a novel concept and sensor design for “off-the-person” ECG, for which evidence on how it compares against standard clinical-grade equipment has been largely missing. Our objectives with this work are to characterise the off-the-person approach in light of the current ECG systems landscape, and assess how the signals acquired using this simplified setup compare with clinical-grade recordings. Empirical tests have been performed with real-world data collected from a population of 38 control subjects, to analyze the correlation between both approaches. Results show off-the-person data to be correlated with clinical-grade data, demonstrating the viability of this approach to potentially extend preventive medicine practices by enabling the integration of ECG monitoring into multiple dimensions of people’s everyday lives. © 2015, IUPESM and Springer-Verlag Berlin Heidelberg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A correlation and predictive scheme for the viscosity and self-diffusivity of liquid dialkyl adipates is presented. The scheme is based on the kinetic theory for dense hard-sphere fluids, applied to the van der Waals model of a liquid to predict the transport properties. A "universal" curve for a dimensionless viscosity of dialkyl adipates was obtained using recently published experimental viscosity and density data of compressed liquid dimethyl (DMA), dipropyl (DPA), and dibutyl (DBA) adipates. The experimental data are described by the correlation scheme with a root-mean-square deviation of +/- 0.34 %. The parameters describing the temperature dependence of the characteristic volume, V-0, and the roughness parameter, R-eta, for each adipate are well correlated with one single molecular parameter. Recently published experimental self-diffusion coefficients of the same set of liquid dialkyl adipates at atmospheric pressure were correlated using the characteristic volumes obtained from the viscosity data. The roughness factors, R-D, are well correlated with the same single molecular parameter found for viscosity. The root-mean-square deviation of the data from the correlation is less than 1.07 %. Tests are presented in order to assess the capability of the correlation scheme to estimate the viscosity of compressed liquid diethyl adipate (DEA) in a range of temperatures and pressures by comparison with literature data and of its self-diffusivity at atmospheric pressure in a range of temperatures. It is noteworthy that no data for DEA were used to build the correlation scheme. The deviations encountered between predicted and experimental data for the viscosity and self-diffusivity do not exceed 2.0 % and 2.2 %, respectively, which are commensurate with the estimated experimental measurement uncertainty, in both cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O trabalho descrito compreende o desenvolvimento de um anticorpo plástico (MIP, do inglês Molecularly Imprinted Polymer) para o antigénio carcinoembrionário (CEA, do inglês Carcinoembriogenic Antigen) e a sua aplicação na construção de dispositivos portáteis, de tamanho reduzido e de baixo custo, tendo em vista a monitorização deste biomarcador do cancro do colo-retal em contexto Point-of-Care (POC). O anticorpo plástico foi obtido por tecnologia de impressão molecular orientada, baseada em eletropolimerização sobre uma superfície condutora de vidro recoberto por FTO. De uma forma geral, o processo foi iniciado pela electropolimerização de anilina sobre o vidro, seguindo-se a ligação por adsorção do biomarcador (CEA) ao filme de polianilina, com ou sem monómeros carregados positivamente (Cloreto de vinilbenziltrimetilamónio, VB). A última fase consistiu na electropolimerização de o-fenilenodiamina (oPD) sobre a superfície, seguindo-se a remoção da proteína por clivagem de ligações peptídicas, com o auxílio de tripsina. A eficiência da impressão do biomarcador CEA no material polimérico foi controlada pela preparação de um material análogo, NIP (do inglês, Non-Imprinted Polymer), no qual nem a proteína nem o monómero VB estavam presentes. Os materiais obtidos foram caracterizados quimicamente por técnicas de Infravermelho com Transformada de Fourier (FTIR, do inglês, Fourier Transform Infrared Spectroscopy) e microscopia confocal de Raman. Os materiais sensores preparados foram entretanto incluídos em membranas poliméricas de Poli(cloreto de vinilo) (PVC) plastificado, para construção de sensores (biomiméticos) seletivos a CEA, tendo-se avaliado a resposta analítica em diferentes meios. Obteve-se uma boa resposta potenciométrica em solução tampão de Ácido 4-(2-hidroxietil)piperazina-1-etanosulfónico (HEPES), a pH 4,4, com uma membrana seletiva baseada em MIP preparada com o monómero carregado VB. O limite de deteção foi menor do que 42 pg/mL, observando-se um comportamento linear (versus o logaritmo da concentração) até 625 pg/mL, com um declive aniónico igual a -61,9 mV/década e r2>0,9974. O comportamento analítico dos sensores biomiméticos foi ainda avaliado em urina, tendo em vista a sua aplicação na análise de CEA em urina. Neste caso, o limite de deteção foi menor do que 38 pg/mL, para uma resposta linear até 625 pg/mL, com um declive de -38,4 mV/década e r2> 0,991. De uma forma geral, a aplicação experimental dos sensores biomiméticos evidenciou respostas exatas, sugerindo que os biossensores desenvolvidos prossigam estudos adicionais tendo em vista a sua aplicação em amostras de indivíduos doentes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation for the degree of Doctor of Philosophy in Physics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A thesis submitted for the degree of Ph. D. in Physics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Toxoplasmosis is an usually asymptomatic worldwide disseminated infection. In its congenital presentation it may lead to abortion or fetal malformations. Antenatal evaluation is considered of paramount importance to identify seronegative women and allow for prophylaxis. Recent improvements in sensitivity of IgM tests has made IgM detection an extremely protracted acute phase marker, and IgG avidity evaluation test became necessary. Observation has shown that a correlation can be established between IgM levels and avidity percentages, suggesting that frequently the avidity test may not be necessary. In this study we analyzed Toxoplasma gondii IgM levels of 202 samples and their IgG avidity percentages, in order to define specific levels whose IgM quantification could by itself define serodiagnosis and therefore make the avidity evaluation unnecessary. We showed that for IgM levels bellow 2.0 and above 6.0 serodiagnosis of toxoplasmosis could be established without need of IgG avidity test. IgM levels between these two parameters are associated with varying avidity indexes highlighting the importance of its evaluation as a means to confirm toxoplasmosis. Following this demonstration it was possible to avoid the avidity test for 75% of the cases, to reduce the turnaround time and to reduce costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The question of whether HIV-1 RNA in cerebrospinal fluid (CSF) is derived from viral replication in the central nervous system or simply reflects the transit of infected lymphocytes from the blood compartment has long been a matter of debate. Some studies found no correlation between CSF and plasma viral load, whereas others did. The lack of a correlation between the two compartments suggests that the presence of HIV-1 RNA is not simply due to the passive passage of the virus from blood to CSF but rather due to intrathecal replication. To evaluate the correlation between plasma and CSF HIV-1 RNA levels and to identify situations in which there is no correlation between the two compartments, seventy patients were prospectively studied. The association between CSF and plasma viral load was evaluated in the total population and in subgroups of patients with similar characteristics. A correlation between the CSF and plasma compartments was observed for patients undergoing highly active antiretroviral therapy (HAART), those with a CD4 T lymphocyte count lower than 200 cells/mm³, and those with increased CSF protein content. On the other hand, no correlation was observed for patients without adequate virological control, who had a CD4 count higher than 200 cells/mm³ and who did not use HAART. The correlation between the two compartments observed in some patients suggests that CSF HIV-1 RNA levels may reflect plasma levels in these subjects. In contrast, the lack of a correlation between the two compartments in patients who were not on HAART and who had normal CSF proteins and a poor virological control possibly indicates compartmentalization of the virus in CSF and, consequently, plasma-independent intrathecal viral replication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia de Materiais

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ligand K-edge XAS of an [Fe3S4]0 model complex is reported. The pre-edge can be resolved into contributions from the í2Ssulfide, í3Ssulfide, and Sthiolate ligands. The average ligand-metal bond covalencies obtained from these pre-edges are further distributed between Fe3+ and Fe2.5+ components using DFT calculations. The bridging ligand covalency in the [Fe2S2]+ subsite of the [Fe3S4]0 cluster is found to be significantly lower than its value in a reduced [Fe2S2] cluster (38% vs 61%, respectively). This lowered bridging ligand covalency reduces the superexchange coupling parameter J relative to its value in a reduced [Fe2S2]+ site (-146 cm-1 vs -360 cm-1, respectively). This decrease in J, along with estimates of the double exchange parameter B and vibronic coupling parameter ì2/k-, leads to an S ) 2 delocalized ground state in the [Fe3S4]0 cluster. The S K-edge XAS of the protein ferredoxin II (Fd II) from the D. gigas active site shows a decrease in covalency compared to the model complex, in the same oxidation state, which correlates with the number of H-bonding interactions to specific sulfur ligands present in the active site. The changes in ligand-metal bond covalencies upon redox compared with DFT calculations indicate that the redox reaction involves a two-electron change (one-electron ionization plus a spin change of a second electron) with significant electronic relaxation. The presence of the redox inactive Fe3+ center is found to decrease the barrier of the redox process in the [Fe3S4] cluster due to its strong antiferromagnetic coupling with the redox active Fe2S2 subsite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Both primary and secondary gynaecological neuroendocrine (NE) tumours are uncommon, and the literature is scarce concerning their imaging features. METHODS: This article reviews the epidemiological, clinical and imaging features with pathological correlation of gynaecological NE tumours. RESULTS: The clinical features of gynaecological NE tumours are non-specific and depend on the organ of origin and on the extension and aggressiveness of the disease. The imaging approach to these tumours is similar to that for other histological types and the Revised International Federation of Gynecology and Obstetrics (FIGO) Staging System also applies to NE tumours. Neuroendocrine tumours were recently divided into two groups: poorly differentiated neuroendocrine carcinomas (NECs) and well-differentiated neuroendocrine tumours (NETs). NECs include small cell carcinoma and large cell neuroendocrine carcinoma, while NETs account for typical and atypical carcinoids. Cervical small cell carcinoma and ovarian carcinoid are the most common gynaecological NE tumours. The former typically behaves aggressively; the latter usually behaves in a benign fashion and tends to be confined to the organ. CONCLUSION: While dealing with ovarian carcinoids, extra-ovarian extension, bilaterality and multinodularity raise the suspicion of metastatic disease. NE tumours of the endometrium and other gynaecological locations are very rare. TEACHING POINTS: • Primary or secondary neurondocrine (NE) tumours of the female genital tract are rare. • Cervical small cell carcinoma and ovarian carcinoids are the most common gynaecological NE tumours. • Cervical small cell carcinomas usually behave aggressively. • Ovarian carcinoids tend to behave in a benign fashion. • The imaging approach to gynaecological NE tumours and other histological types is similar.