454 resultados para Cornea.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study was designed to evaluate the effects of certain orally active contraceptive steroids on the eye, related to the tolerance of a corneal contact lens. An oestrogen, ethinyloestradiol BP. 0.05 mg, a progestogen, norethisterone acetate BP. 2.50 mg and a control tablet (vitamin C, 50 mg) were utilised. The effect of these preparations on corneal curvature, lacrimal fluid volume and protein composition and directly on corneal lens tolerance was monitored in a group of 23 volunteer patients. The progestogen was found to produce a significant (P≥ 0.05) decrease in tear volume as measured by a 3 minute Schirmer test. A smaller volume reduction was observed with ethinyloestradiol. A normal cornea appears unaffected, within the measurement limits available, by the use of either hormone. However, in the presence of a corneal lens, oestrogen was found to induce substantial corneal steepening, indicative of tissue oedema, during the initial 2-3 weeks of medication. Progestogen occasionally produced a similar effect, which could recur with either hormone shortly after the end of the treatment period. A new method of acrylamide gel electrophoresis was developed for examination of the protein concentration and composition of lacrimal fluid. This allowed much greater resolution of microquantities of unconcentrated fluid than anything previously reported. Quantitation by densitometry has permitted the recording of medication and lens-induced changes in the protein pattern. Tear albumin has been shown to differ from serum albumin and to consist of up to 3 subfractions, 7 further protein fractions may also be resolved. The concentration and probable origin of these proteins have been established and the overall effects of hormone administration described. Individual idiosyncratic responses are also discussed. The study has established tbenature of some effects of contraceptive steroids on the anterior eye, and the probable reasons for resultant corneal lens intolerance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The limbal vascular response to extended contact lens wear was examined in a group comparative study initially intended to last eighteen months. After six months all patients wearing contact lenses had presented with micro-epithelial cysts. This unanticipated occurrence of the micro-epithelial-cysts necessitated termination of the study, and limited the quantity of data collected. However, sufficient results were available to allow a limited description of •the vascular response to this form of contact lens wear. Interpretations of the date collected ore discussed in relation to suggested vasostimulating factors in the cornea. The micro-epithelial cysts observed after extended wear were classified and their rate of recovery recorded. A further clinical study was undertaken to observe cysts in both contact lens - and non contact lens-wearing eyes. Cysts were observed in every category of patient, although the characteristic patterns varied. These observations of micro-epithelial cysts are discussed with respect to the aetiopathogeneses of corneal epithelial cystic disorders. Subsequently, attempts were made to induce cysts in rabbit corneae by extended contact lens wear. Clinical observations revealed cyst-like appearances. Histological sections did not contain cysts but did exhibit signs characteristic •of cystic disorders of the corneal epithelium. In general, the results from the study indicate that extended wear is subjectively acceptable to contact lens wearers. However, the objective findings of significant vascular changes, micro-epithelial cysts and cases of acute red eye response cast considerable doubt on the recommendation of extended wear contact lenses for purely cosmetic applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Aston Eye Study (AES) was instigated in October 2005 to determine the distribution of refractive error and associated ocular biometry in a sample of UK urban school children. The AES is the first study to compare outcome measures separately in White, South Asian and Black children. Children were selected from two age groups (Year 2 children aged 6/7 years, Year8 children aged 12/13 years of age) using random cluster sampling of schools in Birmingham, West Midlands UK. To date, the AES has examined 598 children (302 Year 2,296 Year 8). Using open-field cycloplegic autorefraction, the overall prevalence of myopia (=-0.50D SER in either eye) determined was 19.6%, with a higher prevalence in older (29.4%) compared to younger (9.9%) children (p<0.001). Using multiple logistic regression models, the risk of myopia was higher in Year 8 South Asian compared to White children and higher in children attending grammar schools relative to comprehensive schools. In addition, the prevalence of uncorrected ametropia was found to be high (Year 8: 12.84%, Year 2: 15.23%), which will be of concern to bodies responsible for the implementation of school vision screening strategies. Biometric data using non-contact partial coherence interferometry revealed a contributory effect of axial length (AL) and central corneal radius (CR) on myopic refraction, resulting in a strong coefficient of determination of the AL/CR ratio on refractive error. Ocular biometric measures did not vary significantly as a function of ethnicity, suggesting a greater miscorrelation of components in susceptible ethnic groups to account for their higher myopia prevalence. Corneal radius was found to be steeper in myopes in both age groups, but was found to flatten with increasing axial length. Due to the inextricable link between myopia and axial elongation, the paradoxical finding of the cornea demands further longitudinal investigation, particularly in relation to myopia onset. Questionnaire analysis revealed a history of myopia in parents and siblings to be significantly associated with myopia in Year 8 children, with a dose-dependent rise in the odds ratio of myopia evident with increasing number of myopic parents. By classifying socioeconomic status (SES) using Index of Multiple Deprivation values, it was found that Year 8 children from moderately deprived backgrounds were more at risk of myopia compared with children located at both extremities of the deprivation spectrum. However, the main effect of SES weakened following multivariate analysis, with South Asian ethnicity and grammar schooling remaining associated with Year 8 myopia after adjustment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Contact lenses seem to be the ideal method of vision correction for ametropic people who participate in sporting activities. This thesis sets out to evaluate the viewpoint of the optometric professional and that of the patient on the use of contact lenses in sport and to establish if education is needed within this area. It also aims to provide some scientific evidence on the effect of exercise on the physiology of the cornea with and without contact lenses. Silicone hydrogel contact lenses have previously been suggested to impede heat dissipation from the cornea compared to mid water hydrogels. This was further demonstrated with exercise. The physiological integrity of the cornea is dependant on the amount of oxygen available to its surfaces. Contact lenses can disrupt the diffusion of oxygen to the cornea. Previous methods of measuring the oxygen consumption of the cornea have been limited by their invasive nature and assessment of only a small surface area of the cornea. They are not suitable to measure corneal oxygen consumption during exercise with and without contact lenses. A new method needed to be established. This was achieved by designing a novel method by the use of an oxygen sensor inside an airtight goggle using dynamic quenching of luminescence method. This established a non-contact way of measuring the effect oxygen uptake with and without contact lenses in vivo, allowing the contact lens to be undisturbed in their natural environment. The new method differentiated between the closed-eye and the open-eye condition with a good within-visit repeatability. It also illustrated that the cornea utilises oxygen at a faster rate during controlled aerobic exercise at moderate intensity. New contact lenses are available specifically for sport, these claim to reduce glare and increase contrast for daylight outdoor sports. However, visual benefits of these types of contact lenses cannot be measured easily in an indoor clinical environment, such as the optometric practice. To demonstrate any potential benefits of these lenses emulation of them should be conducted outdoors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The relationship between accommodation and intraocular pressure (lOP) has not been addressed as a research question for over 20 years, when measurement of both of these parameters was less advanced than today. Hence the central aim of this thesis was to evaluate the effects of accommodation on lOP. The instrument of choice throughout this thesis was the Pulsair EasyEye non-contact tonometer (NCT) due principally to its slim-line design which allowed the measurement of lOP in one eye and simultaneous stimulation of accommodation in the other eye. A second reason for using the Pulsair EasyEye NCT was that through collaboration with the manufacturers (Keeler, UK) the instrument's operational technology was made accessible. Hence, the principle components underpinning non-contact lOP measures of 0.1mmHg resolution (an order of magnitude greater than other methods) were made available. The relationship between the pressure-output and corneal response has been termed the pressure-response relationship, aspects of which have been shown to be related to ocular biometric parameters. Further, analysis of the components of the pressure-response relationship together with high-speed photography of the cornea during tonometry has enhanced our understanding of the derivation of an lOP measure with the Pulsair EasyEye NCT. The NCT samples the corneal response to the pressure pulse over a 19 ms cycle photoelectronically, but computes the subject's lOP using the data collected in the first 2.34 ms. The relatively instantaneous nature of the lOP measurement renders the measures susceptible to variations in the steady-state lOP caused by the respiratory and cardiac cycles. As such, the variance associated with these cycles was minimised by synchronising the lOP measures with the cardiac trace and maintaining a constant pace respiratory cycle at 15 breathes/minute. It is apparent that synchronising the lOP measures with the peak, middle or trough of the cardiac trace significantly reduced the spread of consecutive measures. Of the 3 locations investigated, synchronisation with the middle location demonstrated the least variance (coeflicient of variation = 9.1%) and a strong correlation (r = 0.90, p = <0.001) with lOP values obtained with Goldmann contact tonometry (n = 50). Accordingly lOP measures synchronised with the middle location of the cardiac cycle were taken in the RE while the LE fixated low (L; zero D), intermediate (I; 1.50 D) and high (H; 4 D) accommodation targets, Quasi-continuous measures of accommodation responses were obtained during the lOP measurement period using the portable infrared Grand Seiko FR-5000 autorefractor. The lOP reduced between L and I accommodative levels by approximately 0.61 mmHg (p <0.00 I). No significant reduction in IOP between L and H accommodation levels was elicited (p = 0.65) (n = 40). The relationship between accommodation and lOP was characterised by substantial inter-subject variations. Myopes demonstrated a tendency to show a reduction in IOP with accommodation which was significant only with I accommodation levels when measured with the NCT (r = 0.50, p = 0.01). However, the relationship between myopia and lOP change with accommodation reached significance for both I (r = 0.61, p= 0.003) and H (r = 0.531, p= 0.0 1) accommodation levels when measured with the Ocular blood Flow Analyser (OBFA). Investigation of the effects of accommodation on the parameters measured by the OBFA demonstrated that with H accommodation levels the pulse amplitude (PA) and pulse rate (PR) responses differed between myopes and emmetropes (PA: p = 0.03; PR: p = 0.004). As thc axial length increased there was a tendency for the pulsatile ocular blood flow (POBF) to reduce with accommodation, which was significant only with H accommodation levels (r = 0.38, p = 0.02). It is proposed that emmetropes arc able to regulate the POBF responses to changes in ocular perfusion pressure caused by changes in lOP with I (r = 0.77, p <0.001) and H (r = 0.73, p = 0.001) accommodation levels. However, thc relationship between lOP and POBF changes in the myopes was not correlated for both I (r = 0.33, p = 0.20) and H (r = 0.05, p = 0.85) accommodation levels. The thesis presents new data on the relationships between accommodation, lOP and parameters of the OBFA,: and provides evidence for possible lOP and choroidal blood flow regulatory mechanisms. Further the data highlight possible deficits in the vascular regulation of the myopic eye during accommodation, which may play a putative role in the aetiology of myopia development.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The work utilising a new material for contact lenses has fallen into three parts: Physioloeical considerations: Since the cornea is devoid of blood vessels, its oxygen is derived from the atmosphere. Early hydrophilic gel contact lenses interrupted the flow of oxygen and corneal insult resulted. Three techniques of fenestration were tried to overcome this problem. High speed drilling with 0.1 mm diameter twist drills. was found to be mechanically successful, but under clinical conditions mucous blockage of the fenestrations occurred. An investigation was made into the amount of oxygen arriving at the corneal interface; related to gel lens thickness. The results indicated an improvement in corneal oxygen as lens thickness was reduced. The mechanism is thought to be a form of mechanical pump. A series of clinical studies con:firmed the experimental work; the use of thin lenses removing the symptoms of corneal hypoxia. Design: The parameters of lens back curvature. lens thickness and lens diameter have been isolated and related to three criteria of vision (a) Visual acuity. (b) Visual stability and (c) Induced astigmatism. From the results achieved a revised and basically successful design of lens has been developed. Comparative study: The developed form of lens was compared with traditional lenses in a controlled survey. Twelve factors were assessed over a twenty week period of wear using a total of eighty four patients. The results of this study indicate that whilst the expected changes were noted with the traditional lens wearers, gel lens wearers showed no discernible change in any of the factors measured. ldth the exception of' one parameter. In addition to a description of' the completed l'iork. further investigations are ·sug~ested l'lhich. it is hoped. l'iould further improve the optical performance of gel lenses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The thesis investigates the relationship between the biomechanical properties of the anterior human sclera and cornea in vivo using Schiotz tonometry (ST), rebound tonometry (RBT, iCare) and the Ocular Response Analyser (ORA, Reichert). Significant differences in properties were found to occur between scleral quadrants. Structural correlates for the differences were examined using Partial Coherent Interferometry (IOLMaster, Zeiss), Optical Coherent tomography (Visante OCT), rotating Scheimpflug photography (Pentacam, Oculus) and 3-D Magnetic Resonance Imaging (MRI). Subject groups were employed that allowed investigation of variation pertaining to ethnicity and refractive error. One hundred thirty-five young adult subjects were drawn from three ethnic groups: British-White (BW), British-South-Asian (BSA) and Hong-Kong-Chinese (HKC) comprising non-myopes and myopes. Principal observations: ST demonstrated significant regional variation in scleral resistance a) with lowest levels at quadrant superior-temporal and highest at inferior-nasal; b) with distance from the limbus, anterior locations showing greater resistance. Variations in resistance using RBT were similar to those found with ST; however the predominantly myopic HKC group had a greater overall mean resistance when compared to the BW-BSA group. OCT-derived scleral thickness measurements indicated the sclera to be thinner superiorly than inferiorly. Thickness varied with distance from the corneolimbal junction, with a decline from 1 to 2 mm followed by a successive increase from 3 to 7 mm. ORA data varied with ethnicity and refractive status; whilst axial length (AL) was associated with corneal biometrics for BW-BSA individuals it was associated with IOP in the HKC individuals. Complex interrelationships were found between ORA Additional-Waveform-Parameters and biometric data provided by the Pentacam. OCT indicated ciliary muscle thickness to be greater in myopia and more directly linked to posterior ocular volume (from MRI) than AL. Temporal surface areas (SAs, from MRI) were significantly smaller than nasal SAs in myopic eyes; globe bulbosity (from MRI) was constant across quadrants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Recent studies indicate that ocular and scleral rigidity is pertinent to our understanding of glaucoma, age related macular degeneration and the development and pathogenesis of myopia. The principal method of measuring ocular rigidity is by extrapolation of data from corneal indentation tonometry (Ko) using Friedenwald’s transformation algorithms. Using scleral indentation (Schiotz tonometry) we assess whether regional variations in resistance to indentation occur in vivo across the human anterior globe directly, with reference to the deflection of Schiotz scale readings. Methods: Data were collected from both eyes of 26 normal young adult subjects with a range of refractive error (mean spherical equivalent ± S.D. of -1.77 D ± 3.28 D, range -10.56 to +4.38 D). Schiotz tonometry (5.5 g & 7.5 g) was performed on the cornea and four scleral quadrants; supero-temporal (ST) and -nasal (SN), infero-temporal (IT) and -nasal (IN) approximately 8 mm posterior to the limbus. Results: Values of Ko (mm3)-1 were consistent with those previously reported (mean 0.0101 ± 0.0082, range 0.0019–0.0304). In regards to the sclera, significant differences (p < 0.001) were found across quadrants with indentation readings for both loads between means for the cornea and ST; ST and SN; ST and IT, ST and IN. Mean (±S.D.) scale readings for 5.5 g were: cornea 5.93 ± 1.14, ST 8.05 ± 1.58, IT 7.03 ± 1.86, SN 6.25 ± 1.10, IN 6.02 ± 1.49; and 7.5 g: cornea 9.26 ± 1.27, ST 11.56 ± 1.65, IT 10.31 ± 1.74, SN 9.91 ± 1.20, IN 9.50 ± 1.56. Conclusions: Significant regional variation was found in the resistance of the anterior sclera to indentation produced by the Schiotz tonometer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Published data indicate that the polar lipid content of human meibomian gland secretions (MGS) could be anything between 0.5% and 13% of the total lipid. The tear film phospholipid composition has not been studied in great detail and it has been understood that the relative proportions of lipids in MGS would be maintained in the tear film. The purpose of this work was to determine the concentration of phospholipids in the human tear film. Methods: Liquid chromatography mass spectrometry (LCMS) and thin layer chromatography (TLC) were used to determine the concentration of phospholipid in the tear film. Additionally, an Amplex Red phosphatidylcholine-specific phospholipase C (PLC) assay kit was used for determination of the activity of PLC in the tear film. Results: Phospholipids were not detected in any of the tested human tear samples with the low limit of detection being 1.3 µg/mL for TLC and 4 µg/mL for liquid chromatography mass spectrometry. TLC indicated that diacylglycerol (DAG) may be present in the tear film. PLC was in the tear film with an activity determined at approximately 15 mU/mL, equivalent to the removal of head groups from phosphatidylcholine at a rate of approximately 15 µM/min. Conclusions: This work shows that phospholipid was not detected in any of the tested human tear samples (above the lower limits of detection as described) and suggests the presence of DAG in the tear film. DAG is known to be at low concentrations in MGS. These observations indicate that PLC may play a role in modulating the tear film phospholipid concentration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: To determine the validity and reliability of the measurement of corneal curvature and non-invasive tear break-up time (NITBUT) measures using the Oculus Keratograph. METHOD: One hundred eyes of 100 patients had their corneal curvature assessed with the Keratograph and the Nidek ARKT TonorefII. NITBUT was then measured objectively with the Keratograph with Tear Film Scan software and subjectively with the Keeler Tearscope. The Keratograph measurements of corneal curvature and NITBUT were repeated to test reliability. The ocular sensitivity disease index questionnaire was completed to quantify ocular comfort. RESULTS: The Keratograph consistently measured significantly flatter corneal curvatures than the ARKT (MSE difference: +1.83±0.44D), but was repeatable (p>0.05). Keratograph NITBUT measurements were significantly lower than observation using the Tearscope (by 12.35±7.45s; pp < 0.001) and decreased on subsequent measurement (by -1.64 ± 6.03s; p < 0.01). The Keratograph measures the first time the tears break up anywhere on the cornea with 63% of subjects having NI-TBUT's <5s and a further 22% having readings between 5 and 10s. The Tearscope results were found to correlate better with the patients symptoms (r = -0.32) compared to the Keratograph (r = -0.19). Conclusions: The Keratograph requires a calibration off-set to be comparable to other keratometry devices. Its current software detects very early tear film changes, recording significantly lower NITBUT values than conventional subjective assessment. Adjustments to instrumentation software have the potential to enhance the value of Keratograph objective measures in clinical practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The principle theme of this thesis is the advancement and expansion of ophthalmic research via the collaboration between professional Engineers and professional Optometrists. The aim has been to develop new and novel approaches and solutions to contemporary problems in the field. The work is sub divided into three areas of investigation; 1) High technology systems, 2) Modification of current systems to increase functionality, and 3) Development of smaller more portable and cost effective systems. High Technology Systems: A novel high speed Optical Coherence Tomography (OCT) system with integrated simultaneous high speed photography was developed achieving better operational speed than is currently available commercially. The mechanical design of the system featured a novel 8 axis alignment system. A full set of capture, analysis, and post processing software was developed providing custom analysis systems for ophthalmic OCT imaging, expanding the current capabilities of the technology. A large clinical trial was undertaken to test the dynamics of contact lens edge interaction with the cornea in-vivo. The interaction between lens edge design, lens base curvature, post insertion times and edge positions was investigated. A novel method for correction of optical distortion when assessing lens indentation was also demonstrated. Modification of Current Systems: A commercial autorefractor, the WAM-5500, was modified with the addition of extra hardware and a custom software and firmware solution to produce a system that was capable of measuring dynamic accommodative response to various stimuli in real time. A novel software package to control the data capture process was developed allowing real time monitoring of data by the practitioner, adding considerable functionality of the instrument further to the standard system. The device was used to assess the accommodative response differences between subjects who had worn UV blocking contact lens for 5 years, verses a control group that had not worn UV blocking lenses. While the standard static measurement of accommodation showed no differences between the two groups, it was determined that the UV blocking group did show better accommodative rise and fall times (faster), thus demonstrating the benefits of the modification of this commercially available instrumentation. Portable and Cost effective Systems: A new instrument was developed to expand the capability of the now defunct Keeler Tearscope. A device was developed that provided a similar capability in allowing observation of the reflected mires from the tear film surface, but with the added advantage of being able to record the observations. The device was tested comparatively with the tearscope and other tear film break-up techniques, demonstrating its potential. In Conclusion: This work has successfully demonstrated the advantages of interdisciplinary research between engineering and ophthalmic research has provided new and novel instrumented solutions as well as having added to the sum of scientific understanding in the ophthalmic field.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate factors affecting corneoscleral profile (CSP) using Anterior Segment Optical Coherence Tomography (AS-OCT) in combination with conventional videokeratoscopy. METHODS: OCT data were collected from 204 subjects of mean age 34.9 years (SD: ±15.2 yrs, range 18 to 65) using the Zeiss Visante AS-OCT and Medmont M300 corneal topographer. Measurements of corneal diameter (CD), corneal sagittal height (CS), iris diameter (ID), corneoscleral junction angle (CSJ) and scleral radius (SR) were extracted from multiple OCT images. Horizontal visible iris diameter (HVID) and vertical palpebral aperture (PA) were measured using a slit lamp graticule. Subject body height was also measured. Associations were then sought between CSP variables and age, height, ethnicity, sex and refractive error data collected. Results: Significant correlations were found between age and ocular topography variables of HVID, PA, CSJ, SR and ID (P<0.0001), while height correlated with HVID, CD and ID, and power vector terms only with vertical plane keratometry, CD and CS. Significant differences were noted between ethnicities with respect to CD (P=0.0046), horizontal and vertical CS (P=0.0068 and P=0.0095), and also horizontal ID (P=0.0010), while the same variables, with the exception of vertical CS, also varied with sex; horizontal CD (P=0.0018), horizontal CS (P=0.0018) and ID (P=0.0012). Age accounted for up to 36% of the variance in CSP variables. Conclusion: Age is the main factor influencing corneoscleral topography; consequently, this should be taken into consideration in contact lens design, in the optimization of surgical procedures involving the cornea and sclera and in IOL selection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Scaffolds derived from processed tissues offer viable alternatives to synthetic polymers as biological scaffolds for regenerative medicine. Tissue-derived scaffolds provide an extracellular matrix (ECM) as the starting material for wound healing and the functional reconstruction of tissues, offering a potentially valuable approach for the replacement of damaged or missing tissues. Additionally, acellular tissue may provide a natural microenvironment for host-cell migration and the induction of stem cell differentiation to contribute to tissue regeneration. There are a number of processing methods that aim to stabilize and provide an immunologically inert tissue scaffold. Furthermore, these tissue-processing methods can often be applied to xenogenic transplants because the essential components of the ECM are often maintained between species. In this study, we applied several tissue-processing protocols to the cornea in order to obtain a decellularized cornea matrix that maintained the clarity and mechanical properties of the native tissue. Histology, mechanical testing and electron microscopy techniques were used to assess the cell extraction process and the organization of the remaining ECM. In vitro cell seeding experiments confirmed the processed corneas’ biocompatibility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Approximately half of current contact lens wearers suffer from dryness and discomfort, particularly towards the end of the day. Contact lens practitioners have a number of dry eye tests available to help them to predict which of their patients may be at risk of contact lens drop out and advise them accordingly. This thesis set out to rationalize them to see if any are of more diagnostic significance than others. This doctorate has found: (1) The Keratograph, a device which permits an automated, examiner independent technique for measuring non invasive tear break up time (NITBUT) measured NITBUT consistently shorter than measurements recorded with the Tearscope. When measuring central corneal curvature the spherical equivalent power of the cornea was measured as being significantly flatter than with a validated automated keratometer. (2) Non-invasive and invasive tear break-up times significantly correlated to each other, but not the other tear metrics. Symptomology, assessed using the OSDI questionnaire, correlated more with those tests indicating possible damage to the ocular surface (including LWE, LIPCOF and conjunctival staining) than with tests of either tear volume or stability. Cluster analysis showed some statistically significant groups of patients with different sign and symptom profiles. The largest cluster demonstrated poor tear quality with both non-invasive and invasive tests, low tear volume and more symptoms. (3) Care should be taken in fitting patients new to contact lenses if they have a NITBUT less than 10s or an OSDI comfort rating greater than 4.2 as they are more likely to drop-out within the first 6 months. Cluster analysis was not found to be beneficial in predicting which patients will succeed with lenses and which will not. A combination of the OSDI questionnaire and a NITBUT measurement was most useful both in diagnosing dry eye and in predicting contact lens drop out.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tissue Transglutaminase (TG2) and FXIIIa, members of the transglutaminase (TG) family, catalyses a transamidating reaction and form covalent bond between or within proteins. In bone development, both enzymes expressions correlate with the initial of the mineralisation process by osteoblasts and chondrocytes. Exogenous TG2 also promotes maturation of chondrocytes and mineralisation in pre-osteoblasts. To understand the role of endogenous TG2 in osteoblast mineralisation, the TG2 expression was examined during the human osteoblast (HOB) mineralisation. The expression of the endogenous TG2 increased during the mineralisation, yet, its expression was not essential for mineral deposition due to the compensation effect by other members in the TG family. The extracellular transamidating activity of HOBs was found increased during mineralisation and a shift from FXIIIa dominant- to TG2-dominant crosslinking activity was suggested after differentiation. However, the transamidating activity of both TG2 and FXIIIa were not critical for cell mineralisation. On the other hand, Exogenous TG2 was found to enhance wild type HOB and TG2 knockdown HOB mineral deposition. The transamidating activity of TG2 was not required but most likely a close conformation was essential for this enhancement. Results also demonstrated that exogenous TG2 may activate the ß-catenin pathway through LRP5 receptor thus contribute in cell mineralisation. This enhancement could be abolished by addition of ß-catenin inhibitors. Finally, using of TG2 crosslinked collagen gel for bone and cornea repair was evaluated. Crosslinked collagen gel showed promising results in improving HOB mineralisation, human corneal fibroblast (hCF) proliferation and migration. These effects might be resulted from the trapped TG2 within the collagen matrix and the alteration of matrix topography by TG2.