950 resultados para Complete Equipartite Graphs


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hebb proposed that synapses between neurons that fire synchronously are strengthened, forming cell assemblies and phase sequences. The former, on a shorter scale, are ensembles of synchronized cells that function transiently as a closed processing system; the latter, on a larger scale, correspond to the sequential activation of cell assemblies able to represent percepts and behaviors. Nowadays, the recording of large neuronal populations allows for the detection of multiple cell assemblies. Within Hebb's theory, the next logical step is the analysis of phase sequences. Here we detected phase sequences as consecutive assembly activation patterns, and then analyzed their graph attributes in relation to behavior. We investigated action potentials recorded from the adult rat hippocampus and neocortex before, during and after novel object exploration (experimental periods). Within assembly graphs, each assembly corresponded to a node, and each edge corresponded to the temporal sequence of consecutive node activations. The sum of all assembly activations was proportional to firing rates, but the activity of individual assemblies was not. Assembly repertoire was stable across experimental periods, suggesting that novel experience does not create new assemblies in the adult rat. Assembly graph attributes, on the other hand, varied significantly across behavioral states and experimental periods, and were separable enough to correctly classify experimental periods (Naïve Bayes classifier; maximum AUROCs ranging from 0.55 to 0.99) and behavioral states (waking, slow wave sleep, and rapid eye movement sleep; maximum AUROCs ranging from 0.64 to 0.98). Our findings agree with Hebb's view that assemblies correspond to primitive building blocks of representation, nearly unchanged in the adult, while phase sequences are labile across behavioral states and change after novel experience. The results are compatible with a role for phase sequences in behavior and cognition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Shrimp farming is one of the activities that contribute most to the growth of global aquaculture. However, this business has undergone significant economic losses due to the onset of viral diseases such as Infectious Myonecrosis (IMN). The IMN is already widespread throughout Northeastern Brazil and affects other countries such as Indonesia, Thailand and China. The main symptom of disease is myonecrosis, which consists of necrosis of striated muscles of the abdomen and cephalothorax of shrimp. The IMN is caused by infectious myonecrosis virus (IMNV), a non-enveloped virus which has protrusions along its capsid. The viral genome consists of a single molecule of double-stranded RNA and has two Open Reading Frames (ORFs). The ORF1 encodes the major capsid protein (MCP) and a potential RNA binding protein (RBP). ORF2 encodes a probable RNA-dependent RNA polymerase (RdRp) and classifies IMNV in Totiviridae family. Thus, the objective of this research was study the IMNV complete genome and encoded proteins in order to develop a system differentiate virus isolates based on polymorphisms presence. The phylogenetic relationship among some totivirus was investigated and showed a new group to IMNV within Totiviridae family. Two new genomes were sequenced, analyzed and compared to two other genomes already deposited in GenBank. The new genomes were more similar to each other than those already described. Conserved and variable regions of the genome were identified through similarity graphs and alignments using the four IMNV sequences. This analyze allowed mapping of polymorphic sites and revealed that the most variable region of the genome is in the first half of ORF1, which coincides with the regions that possibly encode the viral protrusion, while the most stable regions of the genome were found in conserved domains of proteins that interact with RNA. Moreover, secondary structures were predicted for all proteins using various softwares and protein structural models were calculated using threading and ab initio modeling approaches. From these analyses was possible to observe that the IMNV proteins have motifs and shapes similar to proteins of other totiviruses and new possible protein functions have been proposed. The genome and proteins study was essential for development of a PCR-based detection system able to discriminate the four IMNV isolates based on the presence of polymorphic sites

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analytical study of therapeutic nonrandomized intervention type, intra-group controlled, with the aim of analyzing the cost-effectiveness of compression therapy with manipulated Unna boot in relation to conventional therapy in the healing of venous ulcers (VU) of patients treated in ambulatory clinic. The study population was composed by patients with VU treated by angiologists in Surgical Clinic Ambulatory of the Onofre Lopes University Hospital (HUOL) with a sample of 18 patients. It obtained the assent of the HUOL Ethics in Research Committee (Protocol 276/09). Data collection was performed over a period of four months by the own master's student and 34 nursing students, through the application of the research instrument in the admission of patients to the study and in the ten subsequent evaluations, performed at the time of changing Unna boot, weekly, for a maximum period of 10 weeks. The data were analyzed with SPSS 15.0 software, using descriptive and inferential statistics, and presented as tables, charts and graphs. Among those surveyed, prevailed: females, mean age 57.6 years, low education and income levels, most retired, unemployed or off work, with the standing position more than six hours per day and up to eight hours daily of domestic or occupational activities. In health status profile of respondents there were predominantly sleep, rest and inadequate elevation of the lower limbs, no smoking and/or alcohol use, presence of hypertension and no use of drugs. Most presented the first VU for over 10 years, recurrences, present VU for more than five years, involvement of left leg, in malleolar and / or distal leg region, mild edema, hyperpigmentation, lipodermatosclerosis, telangiectasies, reticular and varicose veins, mild pain, serous exudate in moderate quantity, small lesions (up to 50cm2), with predominance of granulation tissue and / or epithelialization and demarcated, elevated and irregular borders, with crusts and macerated. Most patients reported that in the 10 weeks prior to admission, made bandages at home and / or Basic Health Unit and / or ambulatory, with nursing aides or technicians, daily, and on weekends or holidays, performed by patients themselves, using healing ointment on the lesion, being observed granulation / epithelialization and increase in VU prevalent in the 10 weeks of traditional treatment. After follow up with manipulated Unna boot, was observed a decrease of lesions in all study patients, with complete healing in 27.8% of those between 1 and 5 weeks of treatment, with satisfactory evolution of the lesions, pain and ankle and calf circumferences, and unsatisfactory development of the borders of ulcers, edema, sleep, rest and elevation of the lower limbs, especially in more chronic patients. Furthermore, patients who achieved total healing and exhibited the greatest percentage reduction of lesions had a higher number of wound healing factors (ρ = 0.01 and ρ = 0.027, respectively). The manipulated Unna boot showed better results in those patients with shorter duration of injury, leading them to a satisfactory outcome within a short period of treatment. After the cost-effectiveness analysis, we conclude that the manipulated Unna boot is more effective than conventional therapy in the healing process of VU and is more cost-effective in patients with shorter lesions (ρ = 0.001), shorter treatment (ρ = 0.000) and greater number of wound healing factors (ρ = 0.005).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hardness test is thoroughly used in research and evaluation of materials for quality control. However, this test results are subject to uncertainties caused by the process operator in the moment of the mensuration impression diagonals make by the indenter in the sample. With this mind, an automated equipment of hardness mensuration was developed. The hardness value was obtained starting from the mensuration of plastic deformation suffered by the material to a well-known load. The material deformation was calculated through the mensuration of the difference between the progress and retreat of a diamond indenter on the used sample. It was not necessary, therefore, the manual mensuration of the diagonals, decreasing the mistake source caused by the operator. Tension graphs of versus deformation could be analyzed from data obtained by the accomplished analysis, as well as you became possible a complete observation of the whole process. Following, the hardness results calculated by the experimental apparatus were compared with the results calculated by a commercial microhardness machine with the intention of testing its efficiency. All things considered, it became possible the materials hardness mensuration through an automated method, which minimized the mistakes caused by the operator and increased the analysis reliability

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Block diagrams and signal-flow graphs are used to represent and to obtain the transfer function of interconnected systems. The reduction of signal-flow graphs is considered simpler than the reduction of block diagrams for systems with complex interrelationships. Signal-flow graphs reduction can be made without graphic manipulations of diagrams, and it is attractive for a computational implementation. In this paper the authors propose a computational method for direct reduction of signal-flow graphs. This method uses results presented in this paper about the calculation of literal determinants without symbolic mathematics tools. The Cramer's rule is applied for the solution of a set of linear equations, A program in MATLAB language for reduction of signal-flow graphs with the proposed method is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the stress distribution induced by posterior functional loads on conventional complete dentures and implant-retained overdentures with different attachment systems using a two-dimentional Finite Element Analysis (FEA-2D). Three models representative of edentulous mandible were constructed on AutoCAD software; Group A (control), a model of edentulous mandible supporting a complete denture; Group B, a model of edentulous mandible supporting an overdenture over two splinted implants connected with the bar-clip system; Group C, a model of edentuluos mandible supporting an overdenture over two unsplinted impants with the O-ring system. Evaluation was conducted on Ansys software, with a vertical force of 100 N applied on the mandibular left first molar. When the stress was evaluated in supporting tissues, groups B (51.0 MPa) and C (52.6 MPa) demonstrated higher stress values than group A (10.1 MPa). Within the limits of this study, it may be conclued that the use of an attachment system increased stress values; furthermore, the use of splinted implants associated with the bar-clip attachment system favoured a lower stress distribution over the supporting tissue than the unsplinted implants with an O-ring abutment to retain the manibular overdenture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This finite element analysis compared stress distribution on complete dentures and implant-retained overdentures with different attachment systems. Four models of edentulous mandible were constructed: group A (control), complete denture; group B, overdenture retained by 2 splinted implants with bar-clip system; group C, overdenture retained by 2 unsplinted implants with o'ring system; and group D, overdenture retained by 2 splinted implants with bar-clip and 2 distally placed o'ring system. Evaluation was performed on Ansys software, with 100-N vertical load applied on central incisive teeth. The lowest maximum general stress value (in megapascal) was observed in group A (64.305) followed by groups C (119.006), D (258.650), and B (349.873). The same trend occurred it) supporting tissues with the highest stress value for cortical bone. Unsplinted implants associated with the o'ring attachment system showed the lowest maximum stress values among all overdenture groups. Furthermore, o'ring system also improved stress distribution when associated with bar-clip system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate and correlate quality of life (QoL), and stimulus perception of complete denture users, before and after the insertion of new prostheses. We selected 60 patients using bimaxillary complete conventional dentures who needed to replace their prostheses. During anamnesis, we collected demographic data and applied the Oral Health Impact Profile for Edentulous Patients (OHIP-EDENT) questionnaire and stimulus perception questionnaire (PERCEPTION). Before installation of new prostheses, the patients responded to OHIP-EDENT questionnaire, and on the day of installation, they responded to PERCEPTION questionnaire. At the patients 3-month follow-up, we re-administered the OHIP-EDENT and PERCEPTION questionnaires. The Wilcoxon and MacNemar tests were used to compare patient responses between the time points analysed. Most of the OHIP-EDENT items showed a highly significant impact of the new prostheses on oral health (P = 0.003). The PERCEPTION questionnaire data indicated that the patients experienced significant improvements (P < 0.05) in terms of their sensations with the new prostheses. Cross-lagged data analysis did not show any causality between the OHIP-EDENT and PERCEPTION questionnaires (ZPF test, P = 0.772). We concluded that the treatment was effective with respect to the patients QoL and their adaptation to the new prostheses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study assessed masticatory efficiency and duration of the masticatory cycle in 14 asymptomatic patients with severe bone resorption. All patients had worn complete dentures for over 10 years. Recall visits were scheduled at 5 months and 1 year after receiving new dentures.Materials and Methods: Fourteen patients were evaluated in this study. The Research Diagnostic Criteria questionnaire and tests of the efficiency and duration of the masticatory cycle were performed with artificial food before, 5 months after, and 1 year after new dentures were delivered. Masticatory efficiency was assessed using a sieve system; artificial food was ground for 35 masticatory cycles and monitored by the operator.Results: Masticatory efficiency at 5 months was significantly improved for the 0.42-mm mesh. An improvement in masticatory efficiency and a reduction in mastication time were observed with the new dentures after 1 year.Conclusion: The results of this study indicated that 5 months did not allow enough time to demonstrate improved muscular capacity and ability after receiving new dentures. After 1 year, the duration of the masticatory cycle was reduced, and masticatory efficiency was significantly improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Insertion and follow-up of complete dentures: a literature reviewObjective: The aim of this study was to present the importance of clinical procedures related to insertion and follow-up of complete dentures in elderly patients.Materials and Methods: The success of rehabilitation with complete dentures results from the accuracy of clinical and laboratorial procedures that makes the denture insertion an important step of treatment.Conclusion: The follow-up and professional maintenance of function and hygiene facilitates long-term efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:It has been stated that mandibular overdentures are more satisfactory than conventional dentures, but problems relating to the use of retrospective ratings, lack of control group and sequential provision of treatment may compromise the findings.Objective:To establish a comparison between treatment with conventional complete dentures and implant-retained overdentures in elderly patients by conducting a literature review.Materials and methods:A search of English language peer-review literature was completed using Medline up to 2008 focusing on evidence-based research. Randomised clinical trials (RCTs) and longitudinal prospective studies were favoured in the review, using a general hierarchical classification. Articles that did not focus exclusively on the comparison of patient satisfaction between complete dentures and overdentures were excluded from further evaluation. The last search was conducted in February 2008. Key terms included quality of life, patient satisfaction, edentulism, complete denture and overdenture.Results:Among the 90 articles found in the initial search, 27 met the inclusion criteria. This included 18 RCTs and eight prospective and one cohort study. Most of the articles stated superiority of the mandibular implant-retained overdenture therapy over the conventional complete denture regarding patient satisfaction and quality of life.Conclusion:Even with implant treatment presenting higher patient satisfaction and improvement of quality of life, it was not possible to establish a direct comparison between the studies due to differences in adopted methodologies.