953 resultados para Comparative methods


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: This population-based, cross-sectional study aimed to record the DMFT index for 12 year-old children with dental caries and fluorosis levels in cities with and without public water supply fluoridation. Methods: From the 101 municipalities belonging to the Health Regional Department XV (DRSXV-SJRP) of the São Paulo state in the Southeast region of Brazil, 85 cities were selected after exclusion of those with incomplete data and less than ten years of fluoridation treatment in 2004. The criteria adopted for the assessment of dental caries and fluorosis levels were based on the guidelines published in the WHO Manual 4th edition. The data were analyzed using Fisher’s exact tests at a significance level of 5%. Results: The prevalence of caries in 12 year-old children had no significant association with fluoridated water, and was considered “moderate” and “high” in cities without fluoridation and “low” and “moderate” in cities with fluoridation. A significant association was found between water fluoridation and fluorosis (P=0.001), but not between water fluoridation and the DMFT index (P=0.119). Conclusion: The prevalence of fluorosis was related to water fluoridation in this study. However, fluorosis was also observed in non-fluoridated cities, which may result from fluoride intake through other sources.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The biogas originated from anaerobic degradation of organic matter in landfills consists basically in CH4, CO2, and H2O. The landfills represent an important depository of organic matter with high energetic potential in Brazil, although with inexpressive use in the present. The estimation of production of the productive rate of biogas represents one of the major difficulties of technical order to the planning of capture system for rational consumption of this resource. The applied geophysics consists in a set of methods and techniques with wide use in environmental and hydrogeological studies. The DC resistivity method is largely applied in environmental diagnosis of the contamination in soil and groundwater, due to the contrast of electrical properties frequent between contaminated areas and the natural environment. This paper aims to evaluate eventual relationships between biogas flows quantified in drains located in the landfill, with characteristic patterns of electrical resistivity in depth. The drain of higher flow (117 m3 /h) in depth was characterized for values between 8000 Ω⋅m and 100.000 Ω⋅m, in contrast with values below 2000 Ω⋅m, which characterize in subsurface the drain with less flow (37 m3 /h), besides intermediary flow and electrical resistivity values, attributed to the predominance of areas with accumulation or generation of biogas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Starting induction motors on isolated or weak systems is a highly dynamic process that can cause motor and load damage as well as electrical network fluctuations. Mechanical damage is associated with the high starting current drawn by a ramping induction motor. In order to compensate the load increase, the voltage of the electrical system decreases. Different starting methods can be applied to the electrical system to reduce these and other starting method issues. The purpose of this thesis is to build accurate and usable simulation models that can aid the designer in making the choice of an appropriate motor starting method. The specific case addressed is the situation where a diesel-generator set is used as the electrical supplied source to the induction motor. The most commonly used starting methods equivalent models are simulated and compared to each other. The main contributions of this thesis is that motor dynamic impedance is continuously calculated and fed back to the generator model to simulate the coupling of the electrical system. The comparative analysis given by the simulations has shown reasonably similar characteristics to other comparative studies. The diesel-generator and induction motor simulations have shown good results, and can adequately demonstrate the dynamics for testing and comparing the starting methods. Further work is suggested to refine the equivalent impedance presented in this thesis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study compares information-seeking behavior of Bachelor of Science and Master of Science students in the fields of agricultural extension and education. The authors surveyed Iranian students in departments of agricultural extension and education at four universities in Tehran, Shiraz, Mollasani, and Kermanshah. This study focused on three aspects: (1) comparison of amounts of information-seeking behavior between Bachelor of Science and Master of Science agricultural extension and education students; (2) comparison of information-seeking behavior varieties in Bachelor of Science and Master of Science agricultural extension and education students; (3) Comparison of amounts of available information resources at four universities and its effectiveness on students' information-seeking behavior; and (4) comparison of research and educational outputs in Bachelor of Science and Master of Science students. Scale free technique, division by mean method, principal components analysis technique, Delphi method, t-test, correlation and regression tools were used for data analysis. This study revealed that Bachelor of Science students' information-seeking behavior is for improving educational output, but Master of Science students' information-seeking behavior is for promoting research output. Among varieties of Internet searching skills, library searching skills, and awareness of library information-seeking methods with students' information-seeking behavior, there are not significant differences between two groups of students.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives. To verify the hypothesis that crack analysis and a mechanical test would rank a series of composites in a similar order with respect to polymerization stress. Also, both tests would show similar relationships between stress and composite elastic modulus and/or shrinkage. Methods. Soda-lime glass discs (2-mm thick) with a central perforation (3.5-mm diameter) received four Vickers indentations 500 mu m from the cavity margin. The indent cracks were measured (500x) prior and 10 min after the cavity was restored with one of six materials (Kalore/KL, Gradia/GR, Ice/IC, Wave/WV, Majesty Flow/MF, and Majesty Posterior/MP). Stresses at the indent site were calculated based on glass fracture toughness and increase in crack length. Stress at the bonded interface was calculated using the equation for an internally pressurized cylinder. The mechanical test used a universal testing machine and glass rods (5-mm diameter) as substrate. An extensometer monitored specimen height (2 mm). Nominal stress was calculated dividing the maximum shrinkage force by the specimen cross-sectional area. Composite elastic modulus was determined by nanoindentation and post-gel shrinkage was measured using strain gages. Data were subjected to one-way ANOVA/Tukey or Kruskal-Wallis/Mann-Whitney tests (alpha: 5%). Results. Both tests grouped the composites in three statistical subsets, with small differences in overlapping between the intermediate subset (MF, WV) and the highest (MP, IC) or the lowest stress materials (KL, GR). Higher stresses were developed by composites with high modulus and/or high shrinkage. Significance. Crack analysis demonstrated to be as effective as the mechanical test to rank composites regarding polymerization stress. (c) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives. The null hypothesis was that mechanical testing systems used to determine polymerization stress (sigma(pol)) would rank a series of composites similarly. Methods. Two series of composites were tested in the following systems: universal testing machine (UTM) using glass rods as bonding substrate, UTM/acrylic rods, "low compliance device", and single cantilever device ("Bioman"). One series had five experimental composites containing BisGMA:TEGDMA in equimolar concentrations and 60, 65, 70, 75 or 80 wt% of filler. The other series had five commercial composites: Filtek Z250 (3M ESPE), Filtek A110 (3M ESPE), Tetric Ceram (Ivoclar), Heliomolar (Ivoclar) and Point 4 (Kerr). Specimen geometry, dimensions and curing conditions were similar in all systems. sigma(pol) was monitored for 10 min. Volumetric shrinkage (VS) was measured in a mercury dilatometer and elastic modulus (E) was determined by three-point bending. Shrinkage rate was used as a measure of reaction kinetics. ANOVA/Tukey test was performed for each variable, separately for each series. Results. For the experimental composites, sigma(pol) decreased with filler content in all systems, following the variation in VS. For commercial materials, sigma(pol) did not vary in the UTM/acrylic system and showed very few similarities in rankings in the others tests system. Also, no clear relationships were observed between sigma(pol) and VS or E. Significance. The testing systems showed a good agreement for the experimental composites, but very few similarities for the commercial composites. Therefore, comparison of polymerization stress results from different devices must be done carefully. (c) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim This randomized, controlled, clinical study compared two surgical techniques for root coverage with the acellular dermal matrix graft (ADMG) to evaluate which procedure could provide better root coverage and greater amounts of keratinized tissue. Materials and Methods Fifteen pairs of bilateral Miller Class I or II gingival recessions were treated and assigned randomly to the test group, and the contra-lateral recessions were assigned to the control group. The ADMG was used in both groups. In the control group, the graft and flap were positioned at the level of the cemento-enamel junction (CEJ), and in the test group, the graft was positioned 1 mm apical to the CEJ and the flap 1 mm coronal to the CEJ. The clinical parameters were taken before the surgeries and after 6 months. The gingival recession area, a new parameter, was measured in standardized photographs through a special device and software. Results There were statistically significant differences favouring the proposed technique for all parameters except for the amount of keratinized tissue at 6 months. Conclusions The proposed test technique is more suitable for root coverage procedures with ADMG, and the new parameter evaluated appears valuable for root coverage analysis. (Clinicaltrials.gov Identifier: NCT01175720).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study of ionizing radiation effects on semiconductor devices is of great relevance for the global technological development and is a necessity in some strategic areas in Brazil. This work presents preliminary results of radiation effects in MOSFETs that were exposed to 3.2 Grad radiation dose produced by a 2.6-MeV proton beam. The focus of this work was to electrically characterize a Rectangular-Gate MOSFET (RGT) and a Circular-Gate MOSFET (CGT), manufactured with the On Semiconductor 0.5 mu m standard CMOS fabrication process and to verify a suitable geometry for space applications. During the experiment, I-DS x V-GS curves were measured. After irradiation, the RGT off-state current (I-OFF) increased approximately two orders of magnitude reaching practically the same value of the I-OFF in the CGT, which only doubled its value. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The single machine scheduling problem with a common due date and non-identical ready times for the jobs is examined in this work. Performance is measured by the minimization of the weighted sum of earliness and tardiness penalties of the jobs. Since this problem is NP-hard, the application of constructive heuristics that exploit specific characteristics of the problem to improve their performance is investigated. The proposed approaches are examined through a computational comparative study on a set of 280 benchmark test problems with up to 1000 jobs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: There is a growing need to improve myocardial protection, which will lead to better performance of cardiac operations and reduce morbidity and mortality. Therefore, the objective of this study was to compare the efficacy of myocardial protection solution using both intracellular and extracellular crystalloid type regarding the performance of the electrical conduction system, left ventricular contractility and edema, after being subjected to ischemic arrest and reperfusion. Methods: Hearts isolated from male Wistar (n=32) rats were prepared using Langendorff method and randomly divided equally into four groups according the cardioprotective solutions used Krebs-Henseleit-Buffer (KHB), Bretschneider-HTK (HTK), St. Thomas-1 (STH-1) and Celsior (CEL). After stabilization with KHB at 37 degrees C, baseline values (control) were collected for heart rate (HR), left ventricle systolic pressure (LVSP), maximum first derivate of rise left ventricular pressure (+dP/dt), maximum first derivate of fall left ventricular pressure (-dP/dt) and coronary flow (CF). The hearts were then perfused at 10 degrees C for 5 min and kept for 2 h in static ischemia at 20 degrees C in each cardioprotective solution. Data evaluation was done using analysis of variance in completely randomized One-Way ANOVA and Tukey's test for multiple comparisons. The level of statistical significance chosen was P<0.05. Results: HR was restored with all the solutions used. The evaluation of left ventricular contractility (LVSP, +dP/dt and -dP/dt) showed that treatment with CEL solution was better compared to other solutions. When analyzing the CF, the HTK solution showed better protection against edema. Conclusion: Despite the cardioprotective crystalloid solutions studied are not fully able to suppress the deleterious effects of ischemia and reperfusion in the rat heart, the CEL solution had significantly higher results followed by HTK>KHB>STH-1.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To compare two methods of respiratory inductive plethysmography (RIP) calibration in three different positions. Methods: We evaluated 28 healthy subjects (18 women and 10 men), with a mean age of 25.4 +/- 3.9 years. For all of the subjects, isovolume maneuver calibration (ISOCAL) and qualitative diagnostic calibration (QDC) were used in the orthostatic, sitting, and supine positions. In order to evaluate the concordance between the two calibration methods, we used ANOVA and Bland-Altman plots. Results: The values of the constant of proportionality (X) were significantly different between ISOCAL and QDC in the three positions evaluated: 1.6 +/- 0.5 vs. 2.0 +/- 1.2, in the supine position, 2.5 +/- 0.8 vs. 0.6 +/- 0.3 in the sitting position, and 2.0 +/- 0.8 vs. 0.6 +/- 0.3 in the orthostatic position (p < 0.05 for all). Conclusions: Our results suggest that QDC is an inaccurate method for the calibration of RIP. The K values obtained with ISOCAL reveal that RIP should be calibrated for each position evaluated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and Objectives Transfusion-related acute lung injury (TRALI) is characterized by leukocyte transmigration and alveolar capillary leakage shortly after transfusion. TRALI pathogenesis has not been fully elucidated. In some cases, the infusion of alloantibodies (immune model), whereas in others the combination of neutrophil priming by proinflammatory molecules with the subsequent infusion of biological response modifiers (BRMs) in the hemocomponent (non-immune model) have been implicated. Our aim was to compare the pathological events involved in TRALI induced by antibodies or BRMs using murine models. Materials and Methods In the immune model, human HNA-2+ neutrophils were incubated in vitro with a monoclonal antibody (anti-CD177, clone 7D8) directed against the HNA-2 antigen and injected i.v. in NOD/SCID mice. In the non-immune model, BALB/c mice were treated with low doses of lipopolysaccharide (LPS) followed by platelet-activating factor (PAF) infusion 2 h later. Forty minutes after PAF administration, or 6 h after neutrophil injection, lungs were isolated and histological analysis, determination of a variety of cytokines and chemokines including keratinocyte-derived chemokine (KC), MIP-2, the interleukins IL-1 beta, IL-6, IL-8 as well as TNFa, cell influx and alveolar capillary leakage were performed. Results In both models, characteristic histological findings of TRALI and an increase in KC and MIP-2 levels were detected. In contrast to the immune model, in the non-immune model, there was a dramatic increase in IL-1 beta and TNFa. However, capillary leakage was only detected if PAF was administrated. Conclusions Regardless of the triggering event(s), KC, MIP-2 and integrins participate in TRALI pathogenesis, whereas PAF is essential for capillary leakage when two events are involved.