959 resultados para Collateral agreement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a case of an accidental death or potential suicide by revolver with subsequent injury of another person. A 44-year-old man shot himself in the head while manipulating his.38 caliber special revolver in the kitchen in the presence of his wife, standing approximately 1.5 m next to him. After passing through the husband's head, the lead round-nose bullet entered the region underneath his wife's left eye. When the bullet left the man's head, it retained the energy to penetrate the soft tissue at this distance, including the skin and thin bone plates like the orbital wall. Owing to the low energy of the projectile, the entry wound was of atypical in shape and without loss of tissue. Only a small line-resembling a cut-was externally visible. The man died in the hospital from his injuries; his wife suffered visual loss of her left eye.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The function of the coronary collateral circulation in heart transplant patients has not been investigated in a controlled fashion. Since it partly belongs to the microcirculation, which is affected by transplant vasculopathy, the hypothesis was tested that the coronary collateral circulation in heart transplant recipients is less developed than in coronary artery disease (CAD) patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On April 10, 1998, history was made in Northern Ireland. Years of sectarian violence would end as the Belfast Agreement, known more popularly (and perhaps more fittingly due to the religious identities defining the two sides) as the Good Friday Agreement, was signed bringing peace to Northern Ireland (Northern Ireland Office, 2007). This paper will look at the Good Friday Agreement in detail. By analyzing the historical factors leading up to 1998, the Agreement itself, and the post-Agreement implementation stage,it is possible to pick out the relative successes and failures of the Agreement, and of its implementation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine interobserver and intraobserver agreement for results of low-field magnetic resonance imaging (MRI) in dogs with and without disk-associated wobbler syndrome (DAWS). DESIGN: Validation study. ANIMALS: 21 dogs with and 23 dogs without clinical signs of DAWS. PROCEDURES: For each dog, MRI of the cervical vertebral column was performed. The MRI studies were presented in a randomized sequence to 4 board-certified radiologists blinded to clinical status. Observers assessed degree of disk degeneration, disk-associated and dorsal compression, alterations in intraspinal signal intensity (ISI), vertebral body abnormalities, and new bone formation and categorized each study as originating from a clinically affected or clinically normal dog. Interobserver agreement was calculated for 44 initial measurements for each observer. Intraobserver agreement was calculated for 11 replicate measurements for each observer. RESULTS: There was good interobserver agreement for ratings of disk degeneration and vertebral body abnormalities and moderate interobserver agreement for ratings of disk-associated compression, dorsal compression, alterations in ISI, new bone formation, and suspected clinical status. There was very good intraobserver agreement for ratings of disk degeneration, disk-associated compression, alterations in ISI, vertebral body abnormalities, and suspected clinical status. There was good intraobserver agreement for ratings of dorsal compression and new bone formation. Two of 21 clinically affected dogs were erroneously categorized as clinically normal, and 4 of 23 clinically normal dogs were erroneously categorized as clinically affected. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggested that variability exists among observers with regard to results of MRI in dogs with DAWS and that MRI could lead to false-positive and false-negative assessments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary collaterals protect myocardium jeopardized by coronary artery disease (CAD). Promotion of collateral circulation is desirable before myocardial damage occurs. Therefore, determinants of collateral preformation in patients without CAD should be elucidated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare inter-observer agreement of Stratus™ OCT versus Spectralis™ OCT image grading in patients with neovascular age-related macular degeneration (AMD). Thirty eyes with neovascular AMD were examined with Stratus™ OCT and Spectralis™ OCT. Four different scan protocols were used for imaging. Three observers graded the images for the presence of various pathologies. Inter-observer agreement between OCT models was assessed by calculating intra-class correlation coefficients (ICC). In Stratus™ OCT highest interobserver agreement was found for subretinal fluid (ICC: 0.79), and in Spectralis™ OCT for intraretinal cysts (IRC) (ICC: 0.93). Spectralis™ OCT showed superior interobserver agreement for IRC and epiretinal membranes (ERM) (ICC(Stratus™): for IRC 0.61; for ERM 0.56; ICC(Spectralis™): for IRC 0.93; for ERM 0.84). Increased image resolution of Spectralis™ OCT did improve the inter-observer agreement for grading intraretinal cysts and epiretinal membranes but not for other retinal changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The lectin pathway of complement activation, in particular mannose-binding lectin (MBL), has been extensively investigated over recent years. So far, studies were exclusively based on venous samples. The aim of this study was to investigate whether measurements of lectin pathway proteins obtained by capillary sampling are in agreement with venous samples. Methods: Prospective study including 31 infants that were admitted with suspected early-onset sepsis. Lectin pathway proteins were measured in simultaneously obtained capillary and venous samples. Bland–Altman plots of logarithmized results were constructed, and the mean capillary to venous ratios (ratiocap/ven) were calculated with their 95% confidence intervals (CI). Results: The agreement between capillary and venous sampling was very high for MBL (mean ratiocap/ven, 1.01; 95% CI, 0.85–1.19). Similarly, high agreement was observed for H-ficolin (mean ratiocap/ven, 1.02; 95% CI, 0.72–1.44), MASP-2 (1.04; 0.59–1.84), MASP-3 (0.96; 0.71–1.28), and MAp44 (1.01; 0.82–1.25), while the agreement was moderate for M-ficolin (mean ratiocap/ven, 0.78; 95% CI, 0.27–2.28). Conclusions: The results of this study show an excellent agreement between capillary and venous samples for most lectin pathway proteins. Except for M-ficolin, small volume capillary samples can thus be used when assessing lectin pathway proteins in neonates and young children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the fact that numerous studies pursued the strategy of improving collateral function in patients with peripheral artery disease (PAD), there is currently no method available to quantify collateral arterial function of the lower limb.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteoarthritis due to cranial cruciate ligament (CCL) rupture or hip dysplasia is one of the most important causes of chronic lameness in dogs. This study aimed at comparing nitric oxide (NO) production by the CCL with that of the femoral head ligament (FHL) and the medial collateral ligament (MCL), and investigating the pathway of NO production and the concomitant metalloproteinase (MMP) activity in the presence or absence of an inflammatory stimulus. Ligaments of normal dogs were subjected to different stimuli, and NO and MMP activity from explant culture supernatants were compared. The results showed that in explant cultures of the canine CCL more NO was produced than in those of the other two ligaments. A higher level of NO was produced when CCLs were exposed to the inducible nitric oxide synthase (iNOS)-inducing cocktail TNF/IL-1/LPS, and NO synthesis could be inhibited by both l-NMMA, a general nitric oxide synthase (NOS) inhibitor and l-NIL, a specific iNOS inhibitor. However, a correlation between NO synthesis and iNOS expression levels as determined by immunohistochemistry was not observed. In contrast to CCL, no evidence for iNOS-dependent NO synthesis was observed for MCL and FHL. The CCL produced less MMP than MCL and FHL, and no correlation between MMP and NO could be demonstrated. MMP activity in the CCL increased significantly after 48 h of incubation with the inflammatory stimulus. The results suggest that in canine osteoarthritis NO synthesized by canine CCL plays a more important role in the pathogenesis of osteoarthritis of the stifle than that synthesized by FHL and MCL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study was designed to compare coronary collateral function in patients after bare-metal stent (BMS) or drug-eluting stent (DES) implantation. BACKGROUND: Drug-eluting stents have an inhibitory effect on the production of cytokines, chemotactic proteins, and growth factors, and may therefore negatively affect coronary collateral growth. METHODS: A total of 120 patients with long-term stable coronary artery disease (CAD) after stent implantation were included. Both the BMS group and the DES group comprised 60 patients matched for in-stent stenosis severity of the vessel undergoing collateral flow index (CFI) measurement at follow-up and for the duration of follow-up. The primary end point of the investigation was invasively determined coronary collateral function 6 months after stent implantation. Collateral function was assessed by simultaneous aortic, coronary wedge, and central venous pressure measurements (yielding CFI) and by intracoronary electrocardiogram during balloon occlusion. RESULTS: There were no differences between the groups regarding age, gender, body mass index, frequency of cardiovascular risk factors, use of cardiovascular drugs, severity of CAD, or site of coronary artery stenoses. Despite equal in-stent stenosis severity (46 +/- 34% and 45 +/- 36%) and equal follow-up duration (6.2 +/- 10 months and 6.5 +/- 5.4 months), CFI was diminished in the DES versus BMS group (0.154 +/- 0.097 vs. 0.224 +/- 0.142; p = 0.0049), and the rate of collaterals insufficient to prevent ischemia during occlusion (intracoronary electrocardiographic ST-segment elevation > or =0.1 mV) was higher with 50 of 60 patients in the DES group and 33 of 60 patients in the BMS group (p = 0.001). CONCLUSIONS: Collateral function long after coronary stenting is impaired with DES (sirolimus and paclitaxel) when compared with BMS. Considering the protective nature of collateral vessels, this could lead to more serious cardiac events in the presence of an abrupt coronary occlusion.