1000 resultados para Calibração de parâmetros


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reports the parameters which influence on extraction of humic substances (HS) from peat. The yield, organic and inorganic contend, E4/E6 ratio and elemental composition (C,H,N) of the extracted HS have been determined. The functional groups were identified by Fourier-transform infrared espectroscopy. The results showed influence of the extractor type, concentration, time, temperature and granular texture of the sample in the extraction. This work contributes to better understanding of the extraction process showing the necessity of the standard method to extract humic substances from soil

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By using thermochemical data reported for a series of chelates of the type [Ln(thd)3], thd = 2, 2, 6, 6 ­ tetramethyl- 3,5-heptanedione and Ln = La, Pr, Nd, Sm, Gd, Tb, Ho, Er, Tm and Yb, empirical correlations were found involving thermochemical parameters (e.g. dissociation enthalpy) and the thermodynamic temperatures of the beginning of thermal degradation of the chelates, t i. It is shown that t i values are of capital importance in the study of this all class of coordination compounds. Among others, the empirical equation is obtained: r3+ = (-0,013.Z + 1,36)/0,005, that relates the lanthanide cation radius (pm) with the atomic number of the element. The remarkable fact is that this equation is achieved by using thermogravimetric and calorimetric parameters. Is also shown that t i values are related with the P(M) function values, which are very close related with the energy difference, deltaE, between the lowest electronic energy level of the f n s²d¹ configuration and the lowest energy level of the f n+1s² configuration in the neutral gaseous atoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Water Quality Index (WQI) was used during summer and winter of 1994 and 1995 in the final section of Onça and Feijão streams, downstream Broa Reservoir (São Carlos/SP) to evaluate agricultural and catlleman effects. In Onça stream water quality was "acceptable" in winter and "inappropriate to conventional treatment" in the summer. In Feijão stream the water had an "excellent" quality in winter and "good" in the summer. A MANOVA (Multivariate Analysis of Variance) has used to discriminate seasons and streams. Correlation (p<0,05) among the variables was tested. Water temperature, turbidity, pH and fecal bacteria are highly correlated and can be one of the factors that cause WQI change by seasons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neural Networks are a set of mathematical methods and computer programs designed to simulate the information process and the knowledge acquisition of the human brain. In last years its application in chemistry is increasing significantly, due the special characteristics for model complex systems. The basic principles of two types of neural networks, the multi-layer perceptrons and radial basis functions, are introduced, as well as, a pruning approach to architecture optimization. Two analytical applications based on near infrared spectroscopy are presented, the first one for determination of nitrogen content in wheat leaves using multi-layer perceptrons networks and second one for determination of BRIX in sugar cane juices using radial basis functions networks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The implementation of a quality assurance program in chemical analytical laboratories, that can aid in demonstrate the quality of their results, is an issue of great concern. As a consequence, it is mandatory to give an estimate of the confidence that can be placed on the obtained results. An useful measure of this confidence is the measurement uncertainty and, nowadays, a result without the corresponding uncertainty statement cannot be considered reliable. This paper presents a summary of the most important mechanisms for the evaluation and reporting of the measurement uncertainty. In implementing these principles, it is described the measurement uncertainty estimation associated with the preparation of a uranium elemental reference solution at 2.4 mg.kg-1 from the corresponding certified reference material (in this example at 1003 mg.kg-1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of experiments were performed in order to demonstrate to undergraduate students or users of the differential scanning calorimetry (DSC), that several factors can influence the qualitative and quantitative aspects of DSC results. Saccharin, an artificial sweetner, was used as a probe and its thermal behavior is also discussed on the basis of thermogravimetric (TG) and DSC curves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is a translation from IUPAC nomenclature document by K. Danzer and L. A. Currie (Pure Appl. Chem., 1998, 70(4), 993-1014). Its goal is to establish an uniform and meaningful approach to terminology (in Portuguese), notation, and formulation for calibation in analytical chemistry. In this first part, general fundamentals of calibration are presented, namely for both relationships of qualitative and quantitative variables (relations between variables characterizing certain types analytes of the measured function on the other hand and between variables characterizing the amount or concentration of the chemical species and the intensities of the measured signals, on the other hand). On this basis, the fundamentals of the common single component calibration (Univariate Calibration) which models the relationship y = f(x) between the signal intensities y and the amounts or concentrations x of the analyte under given conditions are represented. Additional papers will be prepared dealing with extensive relationships between several intensities and analyte contents, namely with multivariate calibrations and with optimization and experimental design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A methodology is presented to obtain force field parameters to be used in molecular mechanics. The case of Ru(II) is investigated and the parameters obtained, specially its covalent radii, are employed to model Ru(II) coordination compound. The combined use of molecular mechanics with ab initio methods allowed us to predict the metal-ligand stretching force constant for Ru(II) coordination compounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A model based on chemical structure was developed for the accurate prediction of octanol/water partition coefficient (K OW) of polychlorinated biphenyls (PCBs), which are molecules of environmental interest. Partial least squares (PLS) was used to build the regression model. Topological indices were used as molecular descriptors. Variable selection was performed by Hierarchical Cluster Analysis (HCA). In the modeling process, the experimental K OW measured for 30 PCBs by thin-layer chromatography - retention time (TLC-RT) has been used. The developed model (Q² = 0,990 and r² = 0,994) was used to estimate the log K OW values for the 179 PCB congeners whose K OW data have not yet been measured by TLC-RT method. The results showed that topological indices can be very useful to predict the K OW.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The atrazine photoelectrochemical degradation has been examined in solutions containing TiO2 on immobilized films under a variety of experimental conditions. It was possible to observe that the supporting electrolyte nature affects the intensity of the photocurrent, being an indicative of the adsorption process. The disappearance of the organic molecule follows approximately a pseudo-first order kinetic. As mineralization product, NH4+ and NO3- ion have been identified. These results indicated that the formation of NH4+ ion can be associated to the effect of atrazine adsorption, due to need of potential adaptation together with a variation in the supporting electrolyte concentration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dilutions of methylmetacrylate ranging between 1 and 50 ppm were obtained from a stock solution of 1 ml of monomer in 100 ml of deionised water, and were analyzed by an absorption spectrophotometer in the UV-visible. Absorbance values were used to develop a calibration model based on the PLS, with the aim to determine new sample concentrations. The number of latent variables used was 6, with the standard errors of calibration and prediction found to be 0,048 ml/100 ml and 0,058 ml/100 ml. The calibration model was successfully used to calculate the concentration of monomer released in water, where complete dentures were kept for one hour after polymerization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complexes with the composition Ln(NO3)3.2DTPO.4H2O (Ln = Nd and Er) were synthesized and characterized by infrared and visible absorption spectra (solid state and solution). The results of the absorption spectra in the solid state suggest that metal-ligand bonds are essentially electrostatic in all complexes. The absorption spectra of the nitrate salt solution presented smaller values of the oscillator strength when compared to the spectra of the complexes in the same solvent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study the factors that affect the extraction of pesticide residues from water samples for their determination by solid-phase micro-extraction (SPME) and GC/MS were optimized. The fiber polymer, the extraction mode, the ionic strength, the stirring rate, the pH and the extraction time were the most significant parameters evaluated. The recovery obtained with the proposed method ranged from 94 to 110% and the sensitivity of the method, determined by calculating the detection limit (DL), ranged from 0.004 to 0.1 mug l-1. The results obtained with spiked real samples, at the 0.1 mug l-1 level, showed acceptable conformity with the expected values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of analytical procedures based on multivariate calibration models has been limited in several areas due to requirements of validation and certification of the model. Procedures for validation are presented based on the determination of figures of merit, such as precision (mean, repeatability, intermediate), accuracy, sensitivity, analytical sensitivity, selectivity, signal-to-noise ratio and confidence intervals for PLS models. An example is discussed of a model for polymorphic purity control of carbamazepine by NIR diffuse reflectance spectroscopy. The results show that multivariate calibration models can be validated to fulfill the requirements imposed by industry and standardization agencies.