903 resultados para CONTROLLED CLINICAL TRIAL
Resumo:
Objective: To determine the effects of temazepam on the quality of sleep and on oxygen saturation during sleep in subjects at high altitude.
Resumo:
Objective: To test the clinical equivalence and resource consequences of day care with inpatient care for active rheumatoid arthritis.
Resumo:
Aims: To evaluate the thermal responses and weight gain in preterm infants nursed in a cot on a heated, water-filled mattress (HWM) compared with infants receiving care in an air-heated incubator and to compare mothers' stress, anxiety levels and perceptions of their infants in the two groups. Methods: Stable preterm infants weighing 1300 to 1500 g were enrolled, being randomly allocated to either the study group (n = 41) receiving care in a cot on an HWM, or the control group ( n = 33) receiving incubator care. The mean daily body temperature and episodes of cold stress and hyperthermia were recorded. Weight gain (g kg(-1) body weight d(-1)) was also calculated. The mothers completed questionnaires on their perceptions of their infants, and their anxiety and stress levels before randomization, and 2 - 3 wk later during the trial. Results: The mean body temperature was similar for the first week of the trial ( study group 36.9degreesC vs controls 36.9degreesC). There were no significant differences in the incidence of cold stress, while more hyperthermic episodes were seen in the study group ( p = 0.03). There were no significant differences in weight gain during the first ( study group 21.4 g vs controls 19.6 g) or second weeks of the trial ( study group 20.5 g vs controls 19.2 g). Neonatal morbidity did not differ between the groups. There were no differences in mothers' perceptions of their babies, or feelings of stress or anxiety. Conclusion: There were no differences between infants cot-nursed on an HWM and those receiving incubator care, with the exception of episodes of high temperature. The results suggest that the HWM may be used safely for low-weight preterm infants.
Resumo:
A randomized double-blind Phase I Trial was conducted to evaluate safety, tolerability, and immunogenicity of a yellow fever (YF)-dengue 2 (DEN2) chimera (ChimeriVax™-DEN2) in comparison to that of YF vaccine (YF-VAX®). Forty-two healthy YF naïve adults randomly received a single dose of either ChimeriVax™-DEN2 (high dose, 5 log plaque forming units [PFU] or low dose, 3 log PFU) or YF-VAXâ by the subcutaneous route (SC). To determine the effect of YF pre-immunity on the ChimeriVaxTM-DEN2 vaccine, 14 subjects previously vaccinated against YF received a high dose of ChimeriVax™-DEN2 as an open-label vaccine. Most adverse events were similar to YF-VAX® and of mild to moderate intensity, with no serious side-effects. One hundred percent and 92.3% of YF naïve subjects inoculated with 5.0 and 3.0 log10 PFU of ChimeriVaxTM-DEN2, respectively, seroconverted to wt DEN2 (strain 16681); 92% of subjects inoculated with YF-VAX® seroconverted to YF 17D virus but none of YF naïve subjects inoculated with ChimeriVax-DEN2 seroconverted to YF 17D virus. Low seroconversion rates to heterologous DEN serotypes 1, 3, and 4 were observed in YF naïve subjects inoculated with either ChimeriVax™-DEN2 or YF-VAX®. In contrast, 100% of YF immune subjects inoculated with ChimeriVax™-DEN2 seroconverted to all 4 DEN serotypes. Surprisingly, levels of neutralizing antibodies to DEN 1, 2, and 3 viruses in YF immune subjects persisted after 1 year. These data demonstrated that 1) the safety and immunogenicity profile of the ChimeriVax™-DEN2 vaccine is consistent with that of YF-VAX®, and 2) pre-immunity to YF virus does not interfere with ChimeriVaxTM-DEN2 immunization, but induces a long lasting and cross neutralizing antibody response to all 4 DEN serotypes. The latter observation can have practical implications toward development of a dengue vaccine.
Resumo:
The CancerGrid consortium is developing open-standards cancer informatics to address the challenges posed by modern cancer clinical trials. This paper presents the service-oriented software paradigm implemented in CancerGrid to derive clinical trial information management systems for collaborative cancer research across multiple institutions. Our proposal is founded on a combination of a clinical trial (meta)model and WSRF (Web Services Resource Framework), and is currently being evaluated for use in early phase trials. Although primarily targeted at cancer research, our approach is readily applicable to other areas for which a similar information model is available.
Resumo:
The microbial contamination rate of luers of central venous catheters (CVCs) with either PosiFlow® needleless connectors or standard caps attached was investigated. The efficacy of 70% (v/v) isopropyl alcohol, 0.5% (w/v) chlorhexidine in gluconate 70% (v/v) isopropyl alcohol and 10% (w/v) aqueous povidone-iodine to disinfect the intravenous connections was also assessed. Seventy-seven patients undergoing cardiac surgery who required a CVC as part of their clinical management were randomly allocated either needleless connectors or standard caps. Patients were also designated to receive chlorhexidine/alcohol, isopropyl alcohol or povidone-iodine for pre-CVC insertion skin preparation and disinfection of the connections. After 72 h in situ the microbial contamination rate of 580 luers, 306 with standard caps and 274 with needleless connectors attached, was determined. The microbial contamination rate of the external compression seals of 274 needleless connectors was also assessed to compare the efficacy of the three disinfectants. The internal surfaces of 55 out of 306 (18%) luers with standard caps were contaminated with micro-organisms, whilst only 18 out of 274 (6.6%) luers with needleless connectors were contaminated (P<0.0001). Of those needleless connectors disinfected with isopropyl alcohol, 69.2% were externally contaminated with micro-organisms compared with 30.8% disinfected with chlorhexidine/alcohol (P<0.0001) and 41.6% with povidone-iodine (P<0.0001). These results suggest that the use of needleless connectors may reduce the microbial contamination rate of CVC luers compared with the standard cap. Furthermore, disinfection of needleless connectors with either chlorhexidine/alcohol or povidone-iodine significantly reduced external microbial contamination. Both these strategies may reduce the risk of catheter-related infections acquired via the intraluminal route. © 2003 The Hospital Infection Society. Published by Elsevier Science Ltd. All rights reserved.
Resumo:
Needleless connectors are being increasingly used for direct access to intravascular catheters. However, the potential for microbial contamination of these devices and subsequent infection risk is still widely debated. In this study the microbial contamination rate associated with three-way stopcock luers with standard caps attached was compared to those with Y-type extension set luers with Clearlink® needleless connectors attached. Fifty patients undergoing cardiothoracic surgery who required a central venous catheter (CVC) as part of their peri- and postoperative management were studied for microbial contamination of CVC luers following 72 hrs in situ. Each patient's CVC was randomly designated to have either the three-way stopcocks with caps (control patients) or Clearlink® Y-type extension sets (test patients). Prior to, and following each manipulation of the three-way stopcock luers or Clearlink® devices, a 70% (v/v) isopropyl alcohol swab was used for disinfection of the connections. The microbial contamination of 393 luers, 200 with standard caps and 193 with Clearlink® attached, was determined. The internal surfaces of 20 of 200 (10%) three-way stopcock luers with standard caps were contaminated with micro-organisms whereas only one of 193 (0.5%) luers with Clearlink® attached was contaminated (P < 0.0001). These results demonstrate that the use of the Clearlink® device with a dedicated disinfection regimen reduces the internal microbial contamination rate of CVC luers compared with standard caps. The use of such needle-free devices may therefore reduce the intraluminal risk of catheter-related bloodstream infection and thereby supplement current preventive guidelines. © 2006 The Hospital Infection Society.
Resumo:
Background/aims To investigate the efficacy and safety of the MGDRx EyeBag (The Eyebag Company, Halifax, UK) eyelid warming device. Methods Twenty-five patients with confirmed meibomian gland dysfunction (MGD)-related evaporative dry eye were enrolled into a randomised, single masked, contralateral clinical trial. Test eyes received a heated device; control eyes a non-heated device for 5 min twice a day for 2 weeks. Efficacy (ocular symptomology, noninvasive break-up time, lipid layer thickness, osmolarity, meibomian gland dropout and function) and safety (visual acuity, corneal topography, conjunctival hyperaemia and staining) measurements were taken at baseline and follow-up. Subsequent patient device usage and ocular comfort was ascertained at 6 months. Results Differences between test and control eyes at baseline were not statistically signi ficant for all measurements ( p>0.05). After 2 weeks, statistically significant improvements occurred in all efficacy measurements in test eyes ( p<0.05). Visual acuity and corneal topography were unaffected (p>0.05). All patients maintained higher ocular comfort after 6 months ( p<0.05), although the bene fit was greater in those who continued usage 1-8 times a month (p<0.001). Conclusions The MGDRx EyeBag is a safe and effective device for the treatment of MGD-related evaporative dry eye. Subjective benefit lasts at least 6 months, aided by occasional retreatment. Trial registration number NCT01870180.
Resumo:
PURPOSE: To describe changes in intraocular pressure (IOP) in the 'alternative treatments to Inhibit VEGF in Age-related choroidal Neovascularisation (IVAN)' trial (registered as ISRCTN92166560). DESIGN: Randomised controlled clinical trial with factorial design. PARTICIPANTS: Patients (n=610) with treatment naïve neovascular age-related macular degeneration were enrolled and randomly assigned to receive either ranibizumab or bevacizumab and to two regimens, namely monthly (continuous) or as needed (discontinuous) treatment. METHODS: At monthly visits, IOP was measured preinjection in both eyes, and postinjection in the study eye. OUTCOME MEASURES: The effects of 10 prespecified covariates on preinjection IOP, change in IOP (postinjection minus preinjection) and the difference in preinjection IOP between the two eyes were examined. RESULTS: For every month in trial, there was a statistically significant rise in both the preinjection IOP and the change in IOP postinjection during the time in the trial (estimate 0.02 mm Hg, 95% CI 0.01 to 0.03, p<0.001 and 0.03 mm Hg, 95% CI 0.01 to 0.04, p=0.002, respectively). There was also a small but significant increase during the time in trial in the difference in IOP between the two eyes (estimate 0.01 mm Hg, 95% CI 0.005 to 0.02, p<0.001). There were no differences between bevacizumab and ranibizumab for any of the three outcomes (p=0.93, p=0.22 and p=0.87, respectively). CONCLUSIONS: Anti-vascular endothelial growth factor agents induce increases in IOP of small and uncertain clinical significance.
Resumo:
The present study pursued two objectives in the context of a randomized clinical trial of cognitive-behavioral therapy with parent (CBT/P) and group (GCBT) involvement. The first objective was to examine the variability in treatment outcome. There were three specific aims within the first objective, to evaluate: (1) youth characteristics (age, depressive, and externalizing disorders) as moderators of treatment outcome; (2) the differential outcome of the treatment approaches as a function of youth characteristics; and (3) the relative efficacy of the treatment approaches at each level of the moderators. ^ The second objective was to evaluate the efficacy of anxiety treatments along secondary depressive symptoms and externalizing behaviors. There were five specific aims within the second objective, to evaluate: (1) whether anxiety treatment yields reductions in secondary problems, (2) the efficacy of anxiety treatments in reducing secondary problems as a function of approach and youth characteristics, (3) whether reductions in anxiety symptoms significantly mediate changes in secondary problems, (4) the directionality of change in the hypothesized mediated relations, and (5) whether the hypothesized mediated relations are moderated by treatment approach and youth characteristics. The specific aims were pursued using data collected from 183 youth and their mothers. Research questions were tested using multiple regressions and structural equation modeling. ^ Age, depressive, and externalizing disorders were significant moderators. CBT/P relative to GCBT lowered anxiety more for younger than older youth. GCBT relative to CBT/P lowered anxiety more for older than younger youth. GCBT relative to CBT/P lowered anxiety more for depressed youth than non-depressed youth. GCBT relative to CBT/P lowered anxiety less for externalizing youth than non-externalizing youth. Treatment reduced depressive symptoms and externalizing problem behaviors. Reductions in anxiety mediated changes in depressive symptoms and externalizing problem behaviors. Reversed directionality was found in the relation between social anxiety and depressive symptoms. In CBT/P the direction of change was from depressive to social anxiety. The opposite was true in GCBT. Reductions in social anxiety mediated posttreatment changes in depressive symptoms in GCBT but not CBT/P. The reverse was true at follow-up. Reductions in social anxiety mediated changes in depressive symptoms for girls but not boys.^
Resumo:
Background: Thyroid drains following thyroid surgery are routinely used despite minimal supportive evidence. Our aim in this study is to determine the impact of routine open drainage of the thyroid bed postoperatively on ultrasound-determined fluid accumulation at 24 hours. Methods: We conducted a prospective randomised clinical trial on patients undergoing thyroid surgery. Patients were randomly assigned to a drain group (n = 49) or a no-drain group (n = 44) immediately prior to wound closure. Patients underwent a neck ultrasound on day 1 and day 2 postoperatively. After surgery, we evaluated visual analogue scale pain scores, postoperative analgesic requirements, self-reported scar satisfaction at 6 weeks and complications. Results: There was significantly less mean fluid accumulated in the drain group on both day 1, 16.4 versus 25.1 ml (P-value = 0.005), and day 2, 18.4 versus 25.7 ml (P-value = 0.026), following surgery. We found no significant differences between the groups with regard to length of stay, scar satisfaction, visual analogue scale pain score and analgesic requirements. There were four versus one wound infections in the drain versus no-drain groups. This finding was not statistically significant (P = 0.154). No life-threatening bleeds occurred in either group. Conclusions: Fluid accumulation after thyroid surgery was significantly lessened by drainage. However, this study did not show any clinical benefit associated with this finding in the non-emergent setting. Drains themselves showed a trend indicating that they may augment infection rates. The results of this study suggest that the frequency of acute life-threatening bleeds remains extremely low following abandoning drains. We advocate abandoning routine use of thyroid drains. Trial registration: ISRCTN94715414.