997 resultados para Airborne imaging spectrometry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Distinguishing postmortem gas accumulations in the body due to natural decomposition and other phenomena such as gas embolism can prove a difficult task using purely Multi-Detector Computed Tomography (MDCT). The Radiological Alteration Index (RAI) was created with the intention to be able to identify bodies undergoing the putrefaction process based on the quantity of gas detected within the body. The flaw in this approach is the inability to absolutely determine putrefaction as the origin of gas volumes in cases of moderate alteration. The aim of the current study is to identify percentage compositions of O2, N2, CO2 and the presence of gases such as H2 and H2S within these sampling sites in order to resolve this complication. Materials and methods: All cases investigated in our University Center of Legal Medicine are undergoing a Post-Mortem Computed Tomography (PMCT)-scan before external examination or autopsy as a routine investigation. In the obtained images, areas of gas were characterized as 0, I, II or III based on the amount of gas present according to the RAI (1). The criteria for these characterizations were dependent of the site of gas, for example thoracic and abdominal cavities were graded as I (1 - 3cm gas), II (3 - 5cm gas) and III (>5cm gas). Cases showing gaseous sites with grade II or III were selected for this study. The sampling was performed under CT-guidance to target the regions to be punctured. Luer-lock PTFE syringes equipped with a three-way valve and needles were used to sample the gas directly (2). Gaseous samples were then analysed using gas chromatography coupled to a thermal conductivity detector (GC-TCD). The components present in the samples were expressed as a percentage of the overall gas present. Results: Up to now, we have investigated more than 40 cases using our standardized procedure for sampling and analysis of gas. O2, N2 and CO2 were present in most samples. The following distributions were found to correlate to gas origins of gas embolism/scuba diving accidents, trauma and putrefaction: ? Putrefaction → O2 = 1 - 5%; CO2 > 15%; N2 = 10 - 70%; H2 / H2S / CH4 variable presence ? Gas embolism/Scuba diving accidents → O2 and N2= varying percentages; CO2 > 20% ? Trauma → O2 = small percentage; CO2 < 15%; N2 > 65% H2 and H2S indicated levels of putrefaction along with methane which can also gauge environmental conditions or conditions of body storage/burial. Many cases showing large RAI values (advanced alteration) did reveal a radiological diagnosis which was in concordance with the interpretation of the gas composition. However, in certain cases (gas embolism, scuba divers) radiological interpretation was not possible and only chemical gas analysis was found to lead to the correct diagnosis, meaning that it provided complementary information to the radiological diagnosis. Conclusion: Investigation of postmortem gases is a useful tool to determine origin of gas generation which can aid the diagnosis of the cause of death. Levels of gas can provide information on stage of putrefaction and help to perform essential medico-legal diagnosis such as vital gas embolism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the feasibility, determine the optimal b-value, and assess the utility of 3-T diffusion-weighted MR imaging (DWI) of the spine in differentiating benign from pathologic vertebral compression fractures.Methods and Materials: Twenty patients with 38 vertebral compression fractures (24 benign, 14 pathologic) and 20 controls (total: 23 men, 17 women, mean age 56.2years) were included from December 2010 to May 2011 in this IRB-approved prospective study. MR imaging of the spine was performed on a 3-T unit with T1-w, fat-suppressed T2-w, gadolinium-enhanced fat-suppressed T1-w and zoomed-EPI (2D RF excitation pulse combined with reduced field-of-view single-shot echo-planar readout) diffusion-w (b-values: 0, 300, 500 and 700s/mm2) sequences. Two radiologists independently assessed zoomed-EPI image quality in random order using a 4-point scale: 1=excellent to 4=poor. They subsequently measured apparent diffusion coefficients (ADCs) in normal vertebral bodies and compression fractures, in consensus.Results: Lower b-values correlated with better image quality scores, with significant differences between b=300 (mean±SD=2.6±0.8), b=500 (3.0±0.7) and b=700 (3.6±0.6) (all p<0.001). Mean ADCs of normal vertebral bodies (n=162) were 0.23, 0.17 and 0.11×10-3mm2/s with b=300, 500 and 700s/mm2, respectively. In contrast, mean ADCs were 0.89, 0.70 and 0.59×10-3mm2/s for benign vertebral compression fractures and 0.79, 0.66 and 0.51×10-3mm2/s for pathologic fractures with b=300, 500 and 700s/mm2, respectively. No significant difference was found between ADCs of benign and pathologic fractures.Conclusion: 3-T DWI of the spine is feasible and lower b-values (300s/mm2) are recommended. However, our preliminary results show no advantage of DWI in differentiating benign from pathologic vertebral compression fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary magnetic resonance angiography (MRA) is a technique aimed at establishing a noninvasive test for the assessment of significant coronary stenoses. There are certain boundary conditions that have hampered the clinical success of coronary MRA and coronary vessel wall imaging. Recent advances in hardware and software allow for consistent visualization of the proximal and mid portions of the native coronary arteries. Current research focuses on the use of intravascular MR contrast agents and black blood coronary angiography. One common goal is to create a noninvasive test which might allow for screening for major proximal and mid coronary artery disease. These novel approaches will represent a major step forward in diagnostic cardiology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energy metabolism measurements in spinal cord tumors, as well as in osseous spinal tumors/metastasis in vivo, are rarely performed only with molecular imaging (MI) by positron emission tomography (PET). This imaging modality developed from a small number of basic clinical science investigations followed by subsequent work that influenced and enhanced the research of others. Apart from precise anatomical localization by coregistration of morphological imaging and quantification, the most intriguing advantage of this imaging is the opportunity to investigate the time course (dynamics) of disease-specific molecular events in the intact organism. Most importantly, MI represents one of the key technologies in translational molecular neuroscience research, helping to develop experimental protocols that may later be applied to human patients. PET may help monitor a patient at the vertebral level after surgery and during adjuvant treatment for recurrent or progressive disease. Common clinical indications for MI of primary or secondary CNS spinal tumors are: (i) tumor diagnosis, (ii) identification of the metabolically active tumor compartments (differentiation of viable tumor tissue from necrosis) and (iii) prediction of treatment response by measurement of tumor perfusion or ischemia. While spinal PET has been used under specific circumstances, a question remains as to whether the magnitude of biochemical alterations observed by MI in CNS tumors in general (specifically spinal tumors) can reveal any prognostic value with respect to survival. MI may be able to better identify early disease and to differentiate benign from malignant lesions than more traditional methods. Moreover, an adequate identification of treatment effectiveness may influence patient management. MI probes could be developed to image the function of targets without disturbing them or as treatment to modify the target's function. MI therefore closes the gap between in vitro and in vivo integrative biology of disease. At the spinal level, MI may help to detect progression or recurrence of metastatic disease after surgical treatment. In cases of nonsurgical treatments such as chemo-, hormone- or radiotherapy, it may better assess biological efficiency than conventional imaging modalities coupled with blood tumor markers. In fact, PET provides a unique possibility to correlate topography and specific metabolic activity, but it requires additional clinical and experimental experience and research to find new indications for primary or secondary spinal tumors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Limited information is available regarding the methodology required to characterize hashish seizures for assessing the presence or the absence of a chemical link between two seizures. This casework report presents the methodology applied for assessing that two different police seizures were coming from the same block before this latter one was split. The chemical signature was extracted using GC-MS analysis and the implemented methodology consists in a study of intra- and inter-variability distributions based on the measurement of the chemical profiles similarity using a number of hashish seizures and the calculation of the Pearson correlation coefficient. Different statistical scenarios (i.e., a combination of data pretreatment techniques and selection of target compounds) were tested to find the most discriminating one. Seven compounds showing high discrimination capabilities were selected on which a specific statistical data pretreatment was applied. Based on the results, the statistical model built for comparing the hashish seizures leads to low error rates. Therefore, the implemented methodology is suitable for the chemical profiling of hashish seizures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Puropse/Aim: To learn about the developement of post mortem CT angiography, its indications, benefits, pitfalls and practical application. Content Organization: A. Developement of post mortem CT angiography B. Technical prerequisites C. Practical application of post mortem CT angiography (preparation of the body, injection of contrast agent, examination protocol) D. Indications and benefits (including a comparison with conventional autopsy) E. Interpretation of imaging data (with case demonstrations) F. Artifacts, pitfalls and limitations G. Current and potential future use. Summary: This exhibit demonstrates the developement, application and interpretation of post mortem CT angiography. Teaching points: 1. post mortem CT angiography is feasible and useful for identification of the cause of death 2. depending on the indication it can be superior to autopsy 3. limitations and artifacts need to be known for interpreta

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The functionality of adult neocortical circuits can be altered by novel experiences or learning. This functional plasticity appears to rely on changes in the strength of neuronal connections that were established during development. Here we will describe some of our studies in which we have addressed whether structural changes, including the remodeling of axons and dendrites with synapse formation and elimination, could underlie experience-dependent plasticity in the adult neocortex. Using 2-photon laser-scanning microscopes and transgenic mice expressing GFP in a subset of pyramidal cells, we have observed that a small subset of dendritic spines continuously appear and disappear on a daily basis, whereas the majority of spines persists for months. Axonal boutons from different neuronal classes displayed similar behavior, although the extent of remodeling varied. Under baseline conditions, new spines in the barrel cortex were mostly transient and rarely survived for more than a week. However, when every other whisker was trimmed, the generation and loss of persistent spines was enhanced. Ultrastructural reconstruction of previously imaged spines and boutons showed that new spines slowly form synapses. New spines persisting for a few days always had synapses, whereas very young spines often lacked synapses. New synapses were predominantly found on large, multi-synapse boutons, suggesting that spine growth is followed by synapse formation, preferentially on existing boutons. Altogether our data indicate that novel sensory experience drives the stabilization of new spines on subclasses of cortical neurons and promotes the formation of new synapses. These synaptic changes likely underlie experience-dependent functional remodeling of specific neocortical circuits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gas chromatography-mass spectrometry (GC-MS) method is presented which allows the simultaneous determination of the plasma concentrations of the levo-alpha-acetylmethadol (LAAM) and of its active metabolites (NorLAAM and DiNorLAAM), after derivatization with the reagent trifluoroacetic anhydride (TFAA). No interferences from endogenous compounds were observed following the extraction of plasma samples from 11 different human subjects. The standard curves were linear over a working range of 5-200ng/ml for the three compounds. Recoveries measured at three concentrations ranged from 47 to 67% for LAAM, from 50 to 69% for NorLAAM and from 28 to 50% for DiNorLAAM. Intra- and interday coefficients of variation determined at three concentrations ranged from 5 to 13% for LAAM, from 3 to 9% for NorLAAM and from 5 to 13% for DiNorLAAM. The limits of quantitation of the method were found to be 4ng/ml for the three compounds. No interference was noted from methadone. This sensitive and specific analytical method could be useful for assessing the in vivo relationship between LAAM's blood levels, clinical efficacy and/or cardiotoxicity

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Intravoxel incoherent motion (IVIM) imaging is an MRI perfusion technique that uses a diffusion-weighted sequence with multiple b values and a bi-compartmental signal model to measure the so-called pseudo-diffusion of blood caused by its passage through the microvascular network. The goal of the current study was to assess the feasibility of IVIM perfusion fraction imaging in patients with acute stroke. METHODS: Images were collected in 17 patients with acute stroke. Exclusion criteria were onset of symptoms to imaging >5 days, hemorrhagic transformation, infratentorial lesions, small lesions <0.5 cm in minimal diameter and hemodynamic instability. IVIM imaging was performed at 3 T, using a standard spin-echo Stejskal-Tanner pulsed gradients diffusion-weighted sequence, using 16 b values from 0 to 900 s/mm(2). Image quality was assessed by two radiologists, and quantitative analysis was performed in regions of interest placed in the stroke area, defined by thresholding the apparent diffusion coefficient maps, as well as in the contralateral region. RESULTS: IVIM perfusion fraction maps showed an area of decreased perfusion fraction f in the region of decreased apparent diffusion coefficient. Quantitative analysis showed a statistically significant decrease in both IVIM perfusion fraction f (0.026 ± 0.019 vs. 0.056 ± 0.025, p = 2.2 · 10(-6)) and diffusion coefficient D compared with the contralateral side (3.9 ± 0.79 · 10(-4) vs. 7.5 ± 0.86 · 10(-4) mm(2)/s, p = 1.3 · 10(-20)). CONCLUSION: IVIM perfusion fraction imaging is feasible in acute stroke. IVIM perfusion fraction is significantly reduced in the visible infarct. Further studies should evaluate the potential for IVIM to predict clinical outcome and treatment response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Image quality in magnetic resonance imaging (MRI) is considerably affected by motion. Therefore, motion is one of the most common sources of artifacts in contemporary cardiovascular MRI. Such artifacts in turn may easily lead to misinterpretations in the images and a subsequent loss in diagnostic quality. Hence, there is considerable research interest in strategies that help to overcome these limitations at minimal cost in time, spatial resolution, temporal resolution, and signal-to-noise ratio. This review summarizes and discusses the three principal sources of motion: the beating heart, the breathing lungs, and bulk patient movement. This is followed by a comprehensive overview of commonly used compensation strategies for these different types of motion. Finally, a summary and an outlook are provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On December 4th 2007, a 3-Mm3 landslide occurred along the northwestern shore of Chehalis Lake. The initiation zone is located at the intersection of the main valley slope and the northern sidewall of a prominent gully. The slope failure caused a displacement wave that ran up to 38 m on the opposite shore of the lake. The landslide is temporally associated with a rain-on-snow meteorological event which is thought to have triggered it. This paper describes the Chehalis Lake landslide and presents a comparison of discontinuity orientation datasets obtained using three techniques: field measurements, terrestrial photogrammetric 3D models and an airborne LiDAR digital elevation model to describe the orientation and characteristics of the five discontinuity sets present. The discontinuity orientation data are used to perform kinematic, surface wedge limit equilibrium and three-dimensional distinct element analyses. The kinematic and surface wedge analyses suggest that the location of the slope failure (intersection of the valley slope and a gully wall) has facilitated the development of the unstable rock mass which initiated as a planar sliding failure. Results from the three-dimensional distinct element analyses suggest that the presence, orientation and high persistence of a discontinuity set dipping obliquely to the slope were critical to the development of the landslide and led to a failure mechanism dominated by planar sliding. The three-dimensional distinct element modelling also suggests that the presence of a steeply dipping discontinuity set striking perpendicular to the slope and associated with a fault exerted a significant control on the volume and extent of the failed rock mass but not on the overall stability of the slope.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé: L'évaluation de l'exposition aux nuisances professionnelles représente une étape importante dans l'analyse de poste de travail. Les mesures directes sont rarement utilisées sur les lieux même du travail et l'exposition est souvent estimée sur base de jugements d'experts. Il y a donc un besoin important de développer des outils simples et transparents, qui puissent aider les spécialistes en hygiène industrielle dans leur prise de décision quant aux niveaux d'exposition. L'objectif de cette recherche est de développer et d'améliorer les outils de modélisation destinés à prévoir l'exposition. Dans un premier temps, une enquête a été entreprise en Suisse parmi les hygiénistes du travail afin d'identifier les besoins (types des résultats, de modèles et de paramètres observables potentiels). Il a été constaté que les modèles d'exposition ne sont guère employés dans la pratique en Suisse, l'exposition étant principalement estimée sur la base de l'expérience de l'expert. De plus, l'émissions de polluants ainsi que leur dispersion autour de la source ont été considérés comme des paramètres fondamentaux. Pour tester la flexibilité et la précision des modèles d'exposition classiques, des expériences de modélisations ont été effectuées dans des situations concrètes. En particulier, des modèles prédictifs ont été utilisés pour évaluer l'exposition professionnelle au monoxyde de carbone et la comparer aux niveaux d'exposition répertoriés dans la littérature pour des situations similaires. De même, l'exposition aux sprays imperméabilisants a été appréciée dans le contexte d'une étude épidémiologique sur une cohorte suisse. Dans ce cas, certains expériences ont été entreprises pour caractériser le taux de d'émission des sprays imperméabilisants. Ensuite un modèle classique à deux-zone a été employé pour évaluer la dispersion d'aérosol dans le champ proche et lointain pendant l'activité de sprayage. D'autres expériences ont également été effectuées pour acquérir une meilleure compréhension des processus d'émission et de dispersion d'un traceur, en se concentrant sur la caractérisation de l'exposition du champ proche. Un design expérimental a été développé pour effectuer des mesures simultanées dans plusieurs points d'une cabine d'exposition, par des instruments à lecture directe. Il a été constaté que d'un point de vue statistique, la théorie basée sur les compartiments est sensée, bien que l'attribution à un compartiment donné ne pourrait pas se faire sur la base des simples considérations géométriques. Dans une étape suivante, des données expérimentales ont été collectées sur la base des observations faites dans environ 100 lieux de travail différents: des informations sur les déterminants observés ont été associées aux mesures d'exposition des informations sur les déterminants observés ont été associé. Ces différentes données ont été employées pour améliorer le modèle d'exposition à deux zones. Un outil a donc été développé pour inclure des déterminants spécifiques dans le choix du compartiment, renforçant ainsi la fiabilité des prévisions. Toutes ces investigations ont servi à améliorer notre compréhension des outils des modélisations ainsi que leurs limitations. L'intégration de déterminants mieux adaptés aux besoins des experts devrait les inciter à employer cet outil dans leur pratique. D'ailleurs, en augmentant la qualité des outils des modélisations, cette recherche permettra non seulement d'encourager leur utilisation systématique, mais elle pourra également améliorer l'évaluation de l'exposition basée sur les jugements d'experts et, par conséquent, la protection de la santé des travailleurs. Abstract Occupational exposure assessment is an important stage in the management of chemical exposures. Few direct measurements are carried out in workplaces, and exposures are often estimated based on expert judgements. There is therefore a major requirement for simple transparent tools to help occupational health specialists to define exposure levels. The aim of the present research is to develop and improve modelling tools in order to predict exposure levels. In a first step a survey was made among professionals to define their expectations about modelling tools (what types of results, models and potential observable parameters). It was found that models are rarely used in Switzerland and that exposures are mainly estimated from past experiences of the expert. Moreover chemical emissions and their dispersion near the source have also been considered as key parameters. Experimental and modelling studies were also performed in some specific cases in order to test the flexibility and drawbacks of existing tools. In particular, models were applied to assess professional exposure to CO for different situations and compared with the exposure levels found in the literature for similar situations. Further, exposure to waterproofing sprays was studied as part of an epidemiological study on a Swiss cohort. In this case, some laboratory investigation have been undertaken to characterize the waterproofing overspray emission rate. A classical two-zone model was used to assess the aerosol dispersion in the near and far field during spraying. Experiments were also carried out to better understand the processes of emission and dispersion for tracer compounds, focusing on the characterization of near field exposure. An experimental set-up has been developed to perform simultaneous measurements through direct reading instruments in several points. It was mainly found that from a statistical point of view, the compartmental theory makes sense but the attribution to a given compartment could ñó~be done by simple geometric consideration. In a further step the experimental data were completed by observations made in about 100 different workplaces, including exposure measurements and observation of predefined determinants. The various data obtained have been used to improve an existing twocompartment exposure model. A tool was developed to include specific determinants in the choice of the compartment, thus largely improving the reliability of the predictions. All these investigations helped improving our understanding of modelling tools and identify their limitations. The integration of more accessible determinants, which are in accordance with experts needs, may indeed enhance model application for field practice. Moreover, while increasing the quality of modelling tool, this research will not only encourage their systematic use, but might also improve the conditions in which the expert judgments take place, and therefore the workers `health protection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to illustrate the chest radiographs (CR) and CT imaging features and sequential findings of cavitary necrosis in complicated childhood pneumonia. Among 30 children admitted in the Pediatric Intensive Care Unit for persistent or progressive pneumonia, respiratory distress or sepsis despite adequate antibiotic therapy, a study group of 9 children (5 girls and 4 boys; mean age 4 years) who had the radiographic features and CT criteria for cavitary necrosis complicated pneumonia was identified. The pathogens identified were Streptococcus pneumoniae( n=4), Aspergillus( n=2), Legionella( n=1), and Staphylococcus aureus( n=1). Sequential CR and CT scans were retrospectively reviewed. Follow-up CR and CT were evaluated for persistent abnormalities. Chest radiographs showed consolidations in 8 of the 9 patients. On CT examination, cavitary necrosis was localized to 1 lobe in 2 patients and 7 patients showed multilobar or bilateral areas of cavitary necrosis. In 3 patients of 9, the cavitary necrosis was initially shown on CT and visualization by CR was delayed by a time span varying from 5 to 9 days. In all patients with cavities, a mean number of five cavities were seen on antero-posterior CR, contrasting with the multiple cavities seen on CT. Parapneumonic effusions were shown by CR in 3 patients and in 5 patients by CT. Bronchopleural fistulae were demonstrated by CT alone ( n=3). No purulent pericarditis was demonstrated. The CT scan displayed persistent residual pneumatoceles of the left lower lobe in 2 patients. Computed tomography is able to define a more specific pattern of abnormalities than conventional CR in children with necrotizing pneumonia and allows an earlier diagnosis of this rapidly progressing condition. Lung necrosis and cavitation may also be associated with Aspergillus or Legionella pneumonia in the pediatric population.