979 resultados para Air pollution control industry.
Resumo:
Mode of access: Internet.
Resumo:
Cover title.
Resumo:
Mode of access: Internet.
Resumo:
Transportation Department, Office of Environmental Affairs, Washington, D.C.
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
Resumo:
Prepared by Raytheon Company, Equipment Division, Air Traffic Control Directorate, under contract DOT-FA 76WA-3738.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
Shipping list no.: 89-297-P.
Resumo:
This thesis is concerned with various aspects of Air Pollution due to smell, the impact it has on communities exposed to it, the means by which it may be controlled and the manner in which a local authority may investigate the problems it causes. The approach is a practical one drawing on examples occurring within a Local Authority's experience and for that reason the research is anecdotal and is not a comprehensive treatise on the full range of options available. Odour Pollution is not yet a well organised discipline and might be considered esoteric as it is necessary to incorporate elements of science and the humanities. It has been necessary to range widely across a number of aspects of the subject so that discussion is often restricted but many references have been included to enable a reader to pursue a particular point in greater depth. In a `fuzzy' subject there is often a yawning gap separating theory and practice, thus case studies have been used to illustrate the interplay of various disciplines in resolution of a problem. The essence of any science is observation and measurement. Observation has been made of the spread of odour pollution through a community and also of relevant meterological data so that a mathematical model could be constructed and its predictions checked. It has been used to explore the results of some options for odour control. Measurements of odour perception and human behaviour seldom have the precision and accuracy of the physical sciences. However methods of social research enabled individual perception of odour pollution to be quantified and an insight gained into reaction of a community exposed to it. Odours have four attributes that can be measured and together provide a complete description of its perception. No objective techniques of measurement have yet been developed but in this thesis simple, structured procedures of subjective assessment have been improvised and their use enabled the functioning of the components of an odour control system to be assessed. Such data enabled the action of the system to be communicated using terms that are understood by a non specialist audience.
Resumo:
Exhaust emissions from diesel engines are a substantial source of air pollution in this country. In recognition of this fact, the Environmental Protection Agency has issued strict new regulations due to take effect -in 1991 and 1994 that will drastically reduce the amount of some pollutants these engines will be allowed to emit. The technology is not currently available to produce diesel engines that can meet these regulations without large penalties in engine performance and efficiency. One technique that offers promise of being able to reduce emissions from both existing engines and new engines is alcohol fumigation.
Resumo:
The objective of the research project was to seek acceptable solutions to the air pollution problem created in the asphalt recycling process using modified conventional equipment.
Resumo:
Poor hospital indoor air quality (IAQ) may lead to hospital-acquired infections, sick hospital syndrome and various occupational hazards. Air-control measures are crucial for reducing dissemination of airborne biological particles in hospitals. The objective of this study was to perform a survey of bioaerosol quality in different sites in a Portuguese Hospital, namely the operating theater (OT), the emergency service (ES) and the surgical ward (SW). Aerobic mesophilic bacterial counts (BCs) and fungal load (FL) were assessed by impaction directly onto tryptic soy agar and malt extract agar supplemented with antibiotic chloramphenicol (0.05%) plates, respectively using a MAS-100 air sampler. The ES revealed the highest airborne microbial concentrations (BC range 240-736 CFU/m(3) CFU/m(3); FL range 27-933 CFU/m(3)), exceeding, at several sampling sites, conformity criteria defined in national legislation [6]. Bacterial concentrations in the SW (BC range 99-495 CFU/m(3)) and the OT (BC range 12-170 CFU/m(3)) were under recommended criteria. While fungal levels were below 1 CFU/m(3) in the OT, in the SW (range 1-32 CFU/m(3)), there existed a site with fungal indoor concentrations higher than those detected outdoors. Airborne Gram-positive cocci were the most frequent phenotype (88%) detected from the measured bacterial population in all indoor environments. Staphylococcus (51%) and Micrococcus (37%) were dominant among the bacterial genera identified in the present study. Concerning indoor fungal characterization, the prevalent genera were Penicillium (41%) and Aspergillus (24%). Regular monitoring is essential for assessing air control efficiency and for detecting irregular introduction of airborne particles via clothing of visitors and medical staff or carriage by personal and medical materials. Furthermore, microbiological survey data should be used to clearly define specific air quality guidelines for controlled environments in hospital settings.
Resumo:
The main aim of the research project "On the Contribution of Schools to Children's Overall Indoor Air Exposure" is to study associations between adverse health effects, namely, allergy, asthma, and respiratory symptoms, and indoor air pollutants to which children are exposed to in primary schools and homes. Specifically, this investigation reports on the design of the study and methods used for data collection within the research project and discusses factors that need to be considered when designing such a study. Further, preliminary findings concerning descriptors of selected characteristics in schools and homes, the study population, and clinical examination are presented. The research project was designed in two phases. In the first phase, 20 public primary schools were selected and a detailed inspection and indoor air quality (IAQ) measurements including volatile organic compounds (VOC), aldehydes, particulate matter (PM2.5, PM10), carbon dioxide (CO2), carbon monoxide (CO), bacteria, fungi, temperature, and relative humidity were conducted. A questionnaire survey of 1600 children of ages 8-9 years was undertaken and a lung function test, exhaled nitric oxide (eNO), and tear film stability testing were performed. The questionnaire focused on children's health and on the environment in their school and homes. One thousand and ninety-nine questionnaires were returned. In the second phase, a subsample of 68 children was enrolled for further studies, including a walk-through inspection and checklist and an extensive set of IAQ measurements in their homes. The acquired data are relevant to assess children's environmental exposures and health status.
Resumo:
With the development of new technologies, Air Traffic Control, in the nearby of the airport, switched from a purely visual control to the use of radar, sensors and so on. As the industry is switching to the so-called Industry 4.0, also in this frame, it would be possible to implement some of the new tools that can facilitate the work of Air Traffic Controllers. The European Union proposed an innovative project to help the digitalization of the European Sky by means of the Single European Sky ATM Research (SESAR) program, which is the foundation on which the Single European Sky (SES) is based, in order to improve the already existing technologies to transform Air Traffic Management in Europe. Within this frame, the Resilient Synthetic Vision for Advanced Control Tower Air Navigation Service Provision (RETINA) project, which saw the light in 2016, studied the possibility to apply new tools within the conventional control tower to reduce the air traffic controller workload, thanks to the improvements in the augmented reality technologies. After the validation of RETINA, the Digital Technologies for Tower (DTT) project was established and the solution proposed by the University of Bologna aimed, among other things, to introduce Safety Nets in a Head-Up visualization. The aim of this thesis is to analyze the Safety Nets in use within the control tower and, by developing a working concept, implement them in a Head-Up view to be tested by Air Traffic Control Operators (ATCOs). The results, coming from the technical test, show that this concept is working and it could be leading to a future implementation in a real environment, as it improves the air traffic controller working conditions also when low visibility conditions apply.