929 resultados para Activators appliances


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objectives of this work were to characterize pineapple plants (Ananas comosus L. Merril) cv. Smooth Cayenne, cultured in vitro, in saline medium, in relation to bromelian activity, identifying the parts of the plant with the highest bromelian activity. Also under aim was the study of the influence of saline stress on the enzyme activity. Axillary buds of pineapple were cultivated in vitro in MS medium, supplemented with 2 mg.L-1 BAP and 1 mg.L-1 NAA. The levels of salinity tested were: 0.57 g.L-1 NaCl, 1.15 g.L-1 NaCl, and 2.30 g.L-1 NaCl. Bromelian activity was evaluated in the development of buds, shoots, and roots. The results showed that bromelian activity was higher in buds at the highest salt concentration at 15 days. Cultured shoots showed bromelian activity decreasing in the saline treatments in all the collection, up to 60 days in culture. The roots showed higher bromelian activity in the roots in saline medium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe affected individuals in three generations of a family and another sporadic case, all Brazilian patients, with a combination of signs that diagnose the BCD syndrome. In addition to the cardinal signs, the sporadic case has hypothyroidism and imperforate anus, which was observed previously in one patient. The broadened phenotype and the possibility of involvement of p63 and IRF6 genes in this condition are discussed. © 2003 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A strain of Aspergillus giganteus cultivated in a medium with xylan produced two xylanases (xylanase I and II) which were purified to homogeneity. Their molar mass, estimated by SDS-PAGE, were 21 and 24 kDa, respectively. Both enzymes are glycoproteins with 50°C temperature optimum; optimum pH was 6.0-6.5 for xylanase I and 6.0 for xylanase II. At 50°C xylanase I exhibited higher thermostability than xylanase II. Hg2+, Cu 2+ and SDS were strong inhibitors, 1,4-dithiothreitol stimulated the reaction of both enzymes. Both xylanases are xylan-specific; kinetic parameters indicated higher efficiency in the hydrolysis of oat spelts xylan. In hydrolysis of this substrate, xylotriose, xylotetraose and larger xylooligosaccharides were released and hence the enzymes were classified as endoxylanases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Staphylococcal enterotoxins are among the most common etiologic agents that cause food poisoning and, possibly, nonmenstrual toxic shock syndrome. These enterotoxins are also called superantigens because they are potent T cell and macrophages activators. The superantigens bind directly to the major histocompatibility complex class II molecules on antigen-presenting cells and stimulate T cells expressing specific Vβ elements in the cell receptors. Excessive production of cytokines by these cells and macrophages are responsible for the pathogenesis of food poisoning. These cytokine include tumor necrosis factor (TNF)-α, interferon (IFN)-γ and interleukin (IL)-1, proinflamatory mediators with potent immunoenhancing effects; the nitric oxide (NO). It still has both effects citotoxic and regulatory roles in immune function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Patients with fixed orthodontic appliances often experience an absolute increase in the number of Streptococci mutans colony-forming units (cfu). The aim of this investigation was to study the development of biofilm and S. mutans cfu in connection with stainless steel ligatures and elastomeric rings in orthodontic patients treated with and without 0.4% stannous fluoride gel (SFG). Material: Forty-seven patients were divided into 2 groups: those treated with 0.4% SFG for 4 minutes (experimental) and those without 0.4% SFG (control). In each patient, elastomeric rings were used for ligation on 1 side of the dental arch midline, and stainless steel ligatures were used on the opposite side. Saliva samples were collected before and after appliance placement. At 15 and 30 days after appliance placement, biofilm samples from the stainless steel ligatures and the elastomeric rings were collected and subjected to microbiologic procedures and scanning electron microscopy (SEM) analysis. Results: The numbers of S. mutans cfu in the saliva and biofilm were not statistically different between the teeth fitted with elastomeric rings and stainless steel ligatures, or between the experimental and control groups. SEM analysis showed biofilm formation on both ligature ties. Conclusions: Topical application of 0.4% SFG in orthodontic patients with elastomeric rings or stainless steel ligatures does not cause a significant decrease in S. mutans cfu in the saliva and biofilm. Copyright © 2005 by the American Association of Orthodontists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This prospective clinical investigation evaluates the dentoalveolar and skeletal cephalometric changes produced by the Herbst appliance during treatment of mixed dentition patients with Class II division 1 malocclusion. Thirty individuals (15 male and 15 female individuals; initial mean age nine years 10 months) were treated with the Herbst appliance for a period of 12 months. For comparison, the records of 30 untreated Class II children (15 boys, 15 girls; initial mean age nine years eight months) were followed without treatment for a period of 12 months. The results indicated that the treatment effects produced in the mixed dentition patients were primarily dentoalveolar in nature. The mandibular incisors were tipped labially, and the maxillary incisors were retruded; a significant increase in mandibular posterior dentoalveolar height occurred, and there was a restriction in the vertical development of the maxillary molars. There was no difference in the forward growth of the maxilla between the two groups. In comparison with the controls, however, the Herbst treatment produced a modest but statistically significant increase in total mandibular length. This increase in total mandibular length, however, was less than that observed in adolescent Herbst patients in other studies. © 2005 by The EH Angle Education and Research Foundation, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The evolution of light curing units can be noticed by the different systems recently introduced. The technology of LED units promises longer lifetime, without heating and with production of specific light for activation of camphorquinone. However, further studies are still required to check the real curing effectiveness of these units. Purpose: This study evaluated the microhardness of 4 shades (B-0.5, B-1, B-2 and B-3) of composite resin Filtek Z-250 (3M ESPE) after light curing with 4 light sources, being one halogen (Ultralux - Dabi Atlante) and three LED (Ultraled - Dabi Atlante, Ultrablue - DMC and Elipar Freelight - 3M ESPE). Methods: 192 specimens were distributed into 16 groups, and materials were inserted in a single increment in cylindrical templates measuring 4mm x 4mm and light cured as recommended by the manufacturer. Then, they were submitted to microhardness test on the top and bottom aspects of the cylinders. Results: The hardness values achieved were submitted to analysis of variance and to Tukey test at 5% confidence level. It was observed that microhardness of specimens varied according to the shade of the material and light sources employed. The LED appliance emitting greater light intensity provided the highest hardness values with shade B-0.5, allowing the best curing. On the other hand, appliances with low light intensity were the least effective. It was also observed that the bottom of specimens was more sensitive to changes in shade. Conclusion: Light intensity of LED light curing units is fundamental for their good functioning, especially when applied in resins with darker shades.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The force delivered during rapid maxillary expansion (RME) produces areas of compression on the periodontal ligament of the supporting teeth. The resulting alveolar bone resorption can lead to unwanted tooth movement in the same direction. The purpose of this study was to evaluate periodontal changes by means of computed tomography after RME with tooth-tissue-borne and tooth-borne expanders. Methods: The sample comprised 8 girls, 11 to 14 years old, with Class I or II malocclusions with unilateral or bilateral posterior crossbites Four girls were treated with tooth-tissue-borne Haas-type expanders, and 4 were treated with tooth-borne Hyrax expanders. The appliances were activated up to the full 7-mm capacity of the expansion screw. Spiral CT scans were taken before expansion and after the 3-month retention period when the expander was removed. One-millimeter thick axial sections were exposed parallel to the palatal plane, comprising the dentoalveolar area and the base of the maxilla up to the inferior third of the nasal cavity. Multiplanar reconstruction was used to measure buccal and lingual bone plate thickness and buccal alveolar bone crest level by means of the computerized method. Results and Conclusions: RME reduced the buccal bone plate thickness of supporting teeth 0.6 to 0.9 mm and increased the lingual bone plate thickness 0.8 to 1.3 mm. The increase in lingual bone plate thickness of the maxillary posterior teeth was greater in the tooth-borne expansion group than in the tooth-tissue-borne group. RME induced bone dehiscences on the anchorage teeth's buccal aspect (7.1 ± 4.6 mm at the first premolars and 3.8 ± 4.4 mm at the mesiobuccal area of the first molars), especially in subjects with thinner buccal bone plates. The tooth-borne expander produced greater reduction of first premolar buccal alveolar bone crest level than did the tooth-tissue-borne expander. © 2006 American Association of Orthodontists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: This review of the literature intends to evaluate the effect of brushes with high frequency motion when compared with manual toothbrushes regarding the indices of plaque and gingival bleeding. METHODS: Patients presenting gingivitis and/or chronic periodontitis were evaluated in addition to patients having osseointegrated implants and fixed orthodontic appliances. Pertinent literature was reviewed to select articles according to previously defined inclusion criteria. RESULTS: In the assessed studies results showed significant decreases in plaque and gingival indices by utilization of both types of brushes. However, in the selected studies where sonic brushes were tested in orthodontic and dental implant patients there was a more significant decrease in the indices. Furthermore, there was no indication of gingival recession attributed to product use. CONCLUSION: Future studies with a more homogeneous methodology and better experiment designs will be needed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To determine if changes in the lower intercanine widths during orthodontic treatment with fixed appliances result in gingival margin changes around the lower canines and incisors. METHOD: Pre- and post-treatment intra-oral photographs and orthodontic study models of 178 Caucasian adolescents (101 female, 77 male) were used. All subjects were treated with fixed appliances. The subjects had mean ages of 11.41 (SD: 1.83) years and 14.91 (SD: 1.78) years on their initial and final records respectively. The latter were taken 28 days or more after the appliances had been removed. The inclusion criteria were: Angle Class I or Class II malocclusion (with or without transverse and/or vertical discrepancies); nonextraction treatment; less than 4 mm crowding or spacing; fully erupted lower incisors and good periodontal health. The intercanine widths and the positions of the gingival margins relative to the maximum curvatures of the labial surfaces of the lower canines and incisors were measured with digital calipers. RESULTS: A significant association was found between unaltered intercanine widths and coronal migration of the gingival margins (p = 0.045). There were no significant associations between either increased or reduced intercanine widths and changes in the gingival margins. CONCLUSIONS: Following orthodontic treatment coronal migration of the gingival margins around the lower incisors and canines is more likely to be associated with an unaltered intercanine width.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to evaluate the effect of surface glazing and polishing of yttrium-stabilized tetragonal zirconia polycrystal ceramic on early dental biofilm formation, as well as the effect of brushing on the removal of adhered bacteria. Two subjects used oral appliances with polished and glazed samples fixed to the right and left sides. After 20 minutes, 1 hour, and 6 hours, the subjects manually brushed the samples on the right side. The samples were analyzed using scanning electron microscopy. Granular material was verified on the samples, especially on irregular surfaces. After 1 hour, there was no significant difference between glazed and polished surfaces in terms of bacterial presence. However, glazed surfaces tended to accumulate more biofilm, and brushing did not completely remove the biofilm. Polished surfaces seem to present a lower tendency for biofilm formation. Int J Prosthodont 2007;20:419-422.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This in vivo experimental study evaluated the efficacy of fluoride-releasing elastomers in the control of Streptococcus mutans levels in the oral cavity. Forty orthodontic patients were recruited and divided into two groups of 20. Fluoride-releasing elastomeric ligature ties (Fluor-I-Ties, Ortho Arch Co. Inc., USA) were used in the experimental group, and conventional elastomeric ligature ties (D. Morelli, Brazil), in the control group. Two initial samples of saliva were collected at a 14-day interval to determine the number of colony forming units (CFU) of Streptococcus mutans. Immediately after collecting the second sample, fluoride-releasing elastomeric ligature ties were placed in the patients of the experimental group, and conventional ligature ties, in the patients of the control group. Seven, 14 and 28 days after placement of the elastomeric ligature ties, saliva and plaque surrounding the orthodontic appliance were collected for microbiologic analysis. There were no significant differences in the number of Streptococcus mutans CFUs in saliva or plaque in the area surrounding the fluoride-releasing or conventional elastomeric ligature ties. Thus, fluoride-releasing elastomeric ligature ties should not be indicated to reduce the incidence of enamel decalcification in orthodontic patients. Since there was no significant reduction in S. mutans in saliva or plaque, other means of prevention against enamel decalcification should be indicated for these patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to assess the salivary residual effect of fluoride dentifrice on human enamel subjected to an erosive challenge. This crossover in situ study was performed in two phases (A and B), involving ten volunteers. In each phase, they wore acrylic palatal appliances, each containing 3 human enamel blocks, during 7 days. The blocks were subjected to erosion by immersion of the appliances in a cola drink for 5 minutes, 4 times a day. Dentifrice was used to brush the volunteers' teeth, 4 times a day, during 1 minute, before the appliance was replaced into the mouth. In phases A and B the dentifrices used had the same formulation, except for the absence (PD) or presence (FD) of fluoride, respectively. Enamel alterations were determined using profilometry, microhardness (%SMHC), acid- and alkali-soluble F analysis. The data were tested using ANOVA (p < 0.05). The concentrations (mean ± SD) of alkali- and acid-soluble F (μgF/cm 2) were, respectively, PD: 1.27 a ± 0.70/2.24∧ A ± 0.36 and FD: 1.49 a ± 0.44/2.24∧ ± 0.67 (p > 0.05). The mean wear values (± SD, μm) were PD: 3.63 a ± 1.54 and FD: 3.54 a ± 0.90 (p > 0.05). The mean %SMHC values (± SD) were PD: 89.63 a ± 4.73 and FD: 87.28 a ± 4.01 (p > 0.05). Thus, we concluded that the residual fluoride from the fluoride-containing dentifrice did not protect enamel against erosion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: The aim of this study was to evaluate in situ, the early bacterial colonization on feldspar-ceramics submitted to different glazing. Methods and Materials: Fourteen standardized disc specimens (diameter: 5 mm, thickness: 1.5 mm) of each of two micro-particulate feldspathic ceramics (VM7 and VM13, Vita) were produced according to manufacturers' specifications for a total of 28 specimens (24 for the analysis of biofilm and 4 for topographic analysis analyzing the ceramic surfaces). Specimens from each type of ceramic were submitted to two different glazing methods composing four groups: VM7 glazed using glazing liquid Vita Akzent® 25 (G1) and glaze firing (G2), VM13 glazed using glazing liquid (G3) and glaze firing (G4). Six individuals (n=6) wore oral appliances with four ceramic specimens, fixed on the buccal face of the appliances. After 8 hours, each sample was evaluated for the presence (1) or absence (0) of bacterial colonization under a scanning electron microscope (SEM) on five randomly selected fields. The value for each sample was cumulative of the results observed in the fields. One sample from each group was evaluated under a SEM to verify the topographic pattern. Results: There was no difference with regard to bacterial colonization between the feldspar-ceramics and between the glazing types (Kruskal-Wallis non-parametric test). Conclusion: Feldspar-ceramics submitted to firing or glaze firing with Vita Akzent® 25 present a similar condition for in situ bacterial colonization. The similar topographic pattern of the ceramic surfaces seems to have influenced the bacterial colonization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The snoring is produced by the vibration of the soft palatum and/or other oropharyngeal tissues, during the air passage, in the breathing function. OSAHS is defined as the closing of 30%, at least, of the nasal/ buccal airway for 10 seconds or more, in spite of existing inspiratory effort, accompanied by oxyhemoglobin de- saturation of 4% or more. Objectives: To evaluate the available scientific evidence about the use of mandibular advancement intraoral appliances in the treatment of the snoring and/or OSAHS. Methodology: Electronic search strategy using predefined key-words and criteria was realized including studies published until October of 2008. It was also used the qualitative evaluation of the articles methodology. Results: Although a significant number of articles has studied this subject, only 7 articles showed methodological quality to be included in this systematic review. Conclusions: The intraoral appliances are widely prescribed for the treatment of snoring and OSAHS as primary therapy and as an alternative to patients who are unable to tolerate the positive airway pressure therapy.