965 resultados para AIR POLLUTION IN MEGACITIES


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Residential wood combustion has only recently been recognized as a major contributor to air pollution in Switzerland and in other European countries. A source apportionment method using the aethalometer light absorption parameters was applied to five winter campaigns at three sites in Switzerland: a village with high wood combustion activity in winter, an urban background site and a highway site. The particulate mass from traffic (PMtraffic) and wood burning (PMwb) emissions obtained with this model compared fairly well with results from the 14C source apportionment method. PMwb from the model was also compared to well known wood smoke markers such as anhydrosugars (levoglucosan and mannosan) and fine mode potassium, as well as to a marker recently suggested from the Aerodyne aerosol mass spectrometer (mass fragment m/z 60). Additionally the anhydrosugars were compared to the 14C results and were shown to be comparable to literature values from wood burning emission studies using different types of wood (hardwood, softwood). The levoglucosan to PMwb ratios varied much more strongly between the different campaigns (4–13%) compared to mannosan to PMwb with a range of 1–1.5%. Possible uncertainty aspects for the various methods and markers are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objetivo: Evaluar la variación espacial de la exposición a dióxido de nitrógeno (NO2) en la ciudad de Valencia y su relación con la privación socioeconómica y la edad. Métodos: La población por sección censal (SC) procede del Instituto Nacional de Estadística. Los niveles de NO2 se midieron en 100 puntos del área de estudio, mediante captadores pasivos, en tres campañas entre 2002 y 2004. Se utilizó regresión por usos del suelo (LUR) para obtener el mapa de los niveles de NO2. Las predicciones del LUR se compararon con las proporcionadas por: a) el captador más cercano de la red de vigilancia, b) el captador pasivo más cercano, c) el conjunto de captadores en un entorno y d) kriging. Se asignaron niveles de contaminación para cada SC. Se analizó la relación entre los niveles de NO2, un índice de privación con cinco categorías y la edad (≥65 años). Resultados: El modelo LUR resultó el método más preciso. Más del 99% de la población superó los niveles de seguridad propuestos por la Organización Mundial de la Salud. Se encontró una relación inversa entre los niveles de NO2 y el índice de privación (β = –2,01 μg/m3 en el quintil de mayor privación respecto al de menor, IC95%: –3,07 a –0,95), y una relación directa con la edad (β = 0,12 μg/m3 por incremento en unidad porcentual de población ≥65 años, IC95%: 0,08 a 0,16). Conclusiones: El método permitió obtener mapas de contaminación y describir la relación entre niveles de NO2 y características sociodemográficas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The transport of people and goods contributes to the deterioration of the environment in urban areas because of the generation of pollution, such as, air, noise, soil, water or visual degradation. The heavy vehicles that use diesel as fuel are mainly responsible for the emission of nitrogen oxides (NOx) and particulate matter (PM), contributing to participation of the transport sector in air pollution. In addition, there is emission of Greenhouse Gas (GHG) whose main component is carbon dioxide (CO2). In most major cities, public transportation is often considered as a less polluting alternative compared to the private vehicle, in view of the potential to reduce, per passenger, the emissions of GHG and air pollutants. The study area was the city of Uberlândia and the objects of study were the trunk lines of the Sistema Integrado de Transporte (SIT). The emissions of NOx, PM and CO2 were estimated through the bottom-up approach which used the route of each bus line and also fuel consumption obtained through simulation from the TSIS software. The software has some result limitations, there are no report about the emission of pollutants by bus, and it is not able to change specifications for the fuel used by the fleet. The results obtained through calculations of pollutants and GHG emission by the bottom-up approach show that the emission is higher when using fuel comsuption obtained in simulation than using distance. For the results considering fuel and distance there was a reduction in emissions comparing ethanol and diesel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Air pollution can threat the environment and public health, and is assess by pollutant ́s concentration measurements in order to verify whether the limits set by environmental agencies are being respected. However, these measures do not indicate immediately the impacts to living beings. To faced this problem, plants are been investigated as potential bioindicators of air pollution and, among them, stand out bromeliads Tillandsia genus which colonize various substrates,. obtaining water and nutrients from the atmosphere directly. In this context, this research assessed the potential of epiphytic bromeliad Tillandsia recurvata (L.) L. found in urbanized areas of the city of Curitiba - PR as a bioindicator of urban air pollution. According to vehicle traffic, five sample points were selected and classified. Points P1 and P2 were classified as high-traffic vehicle due presenting trucks and urban transport; point P3 was classified as moderate traffic due the predominance of private vehicles and urban transport; and points P4 and P5 were classified as low-traffic, presenting circulation of private vehicles only. There were analyzed the abundance of T. recurvata, morphophysiological parameters (leaf area, leaf specific area, sclerophylly index, percentage dry weight / fresh weight, chlorophyll (a + b), analysis of structural mesophyll organization) and the heavy metals accumulation (Fe, Cd, Cr, Cu, Pb and Zn). The abundance analysis and the results obtained for metals analysis were correlated with the intensity of vehicular traffic, directing the sampling points P1 > P2 = P3 > P4 = P5. This result demonstrate that the abundance of T. recurvata is greater in urban air pollution impacted areas, thus indicating that T. recurvata absorbs and accumulates metals and can be used in biomonitoring of urban air pollution in areas impacted by vehicular traffic. Morphophysiological parameters analyzed shows that the internal plant ́s structure is not significantly impacted by urban air pollution due plant ́s adptations. The presence of absorbing scales, the CAM metabolism pathway and it ́s store water ability, among other features, demonstrate their potential as bio-indicator in urban areas, especially regarding heavy metals accumulation .

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The results of investigations of the influence of aerosol pollution of atmosphere in Tbilisi (the capital of the Georgia, city with the greatest level of air pollution) on the total air electric conductivity in Dusheti (the small city, located in 40-45 km to the north of Tbilisi) are represented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study presents novel evidence that N-15 natural abundance can be used as a robust indicator to detect pollutant nitrogen in natural plant communities. Vegetation from the heavily polluted industrial area of Cubatao in Sao Paulo State, SE Brazil, was strongly N-15 depleted compared to plants at remote sites. Historic herbarium samples from Cubatao were significantly less N-15 depleted than extant plants, indicating that N-15 depletion of vegetation is associated with present-day nitrogen pollution in Cubatao. The heavy load of nitrogenous atmospheric pollutants in Cubatao provides a nitrogen source for plants, and strongly N-15 depleted air NH3 is likely to contribute to plant and soil N-15 depletion. Epiphytic plants from Cubatao were extremely N-15 depleted (average -10.9parts per thousand) contrasting with epiphytes at remote sites (averages -1.0parts per thousand and -3.0parts per thousand). Nitrogen isotope composition of vegetation provides a tool to determine input of pollutant nitrogen into plant communities. The strong isotopic change of epiphytes suggests that epiphytes are particularly sensitive biomonitors for atmospheric pollutant nitrogen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A descriptive study was developed to monitor air fungal contamination in two elementary schools in Lisbon, Portugal. Eight air samples of 250 litres through impaction method were collected in canteen, library, classrooms and also, outside premises as reference place. Simultaneously, were also monitored environmental parameters, including temperature, and humidity through the equipment Babouc, LSI Sistems and according to the International Standard ISO 7726 - 1998. Considering both schools, sixteen different species of fungi in air were identified, being the 2 most commonly isolated Cladosporium sp. (51,1%) and Penicillium sp. (27,5%). Besides these genera Trichoderma, Aspergillus, Alternaria, Chrysonilia, Botritys, Ulocladium, Athrium, Aureobasidium, Phoma, Scedosporium e Geotrichum were also isolated. Regarding yeasts, Candida sp., Cryptococcus sp. and Rhodotorula sp. were isolated. The youngest school, as well canteens in each school, presented the worst results concerning the air fungal contamination, maybe due to the higher number of occupants. There was no significant relationship (p>0,05) between fungal contamination and temperature and humidity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Formaldehyde was the first air pollutant, which already in the 1970s emerged as a specifically non-industrial indoor air quality problem. Yet formaldehyde remained an indoor air quality issue and the formaldehyde level in residential indoor air is among the highest of any indoor air contaminant. Formaldehyde concentrations in 4 different indoor settings (schools, office buildings, new dwellings and occupied dwellings) in Portugal were measured using Photo Ionization Detection (PID) equipment (11,7 eV lamps). All the settings presented results higher than the reference value proposed by Portuguese legislation. Furthermore, occupied dwellings showed 3 units with results above the reference. We could conclude that formaldehyde presence is a reality in monitored indoor settings. Concentration levels are higher than the Portuguese reference value for indoor settings and these can indicate health problems for occupants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Due to their detrimental effects on human health, the scientific interest in ultrafine particles (UFP) has been increasing, but available information is far from comprehensive. Compared to the remaining population, the elderly are potentially highly susceptible to the effects of outdoor air pollution. Thus, this study aimed to (1) determine the levels of outdoor pollutants in an urban area with emphasis on UFP concentrations and (2) estimate the respective dose rates of exposure for elderly populations. UFP were continuously measured over 3 weeks at 3 sites in north Portugal: 2 urban (U1 and U2) and 1 rural used as reference (R1). Meteorological parameters and outdoor pollutants including particulate matter (PM10), ozone (O3), nitric oxide (NO), and nitrogen dioxide (NO2) were also measured. The dose rates of inhalation exposure to UFP were estimated for three different elderly age categories: 64–70, 71–80, and >81 years. Over the sampling period levels of PM10, O3 and NO2 were in compliance with European legislation. Mean UFP were 1.7 × 104 and 1.2 × 104 particles/cm3 at U1 and U2, respectively, whereas at rural site levels were 20–70% lower (mean of 1 ×104 particles/cm3). Vehicular traffic and local emissions were the predominant identified sources of UFP at urban sites. In addition, results of correlation analysis showed that UFP were meteorologically dependent. Exposure dose rates were 1.2- to 1.4-fold higher at urban than reference sites with the highest levels noted for adults at 71–80 yr, attributed mainly to higher inhalation rates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we attempt an empirical application of the multi-region input-output (MRIO) method in order to enumerate the pollution content of interregional trade flows between five Mid-West regions/states in the US –Illinois, Indiana, Iowa, Michigan and Wisconsin – and the rest of the US. This allows us to analyse some very important issues in terms of the nature and significance of interregional environmental spillovers within the US Mid-West and the existence of pollution ‘trade balances’ between states. Our results raise questions in terms of the extent to which authorities at State level can control local emissions where they are limited in the way some emissions can be controlled, particularly with respect to changes in demand elsewhere in the Mid-West and US. This implies a need for policy co-ordination between national and state level authorities in the US to meet emissions reductions targets. The existence of an environmental trade balances between states also raises issues in terms of net losses/gains in terms of pollutants as a result of interregional trade within the US and whether, if certain activities can be carried out using less polluting technology in one region relative to others, it is better for the US as a whole if this type of relationship exists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this work was to evaluate the effects of pollutants on the abundance and diversity of Collembola in urban soils. The research was carried out in three parks (Cişmigiu, Izvor and Unirea) in downtown Bucharest, where the intense car traffic accounts for 70% of the local air pollution. One site in particular (Cişmigiu park) was highly contaminated with Pb, Cd, Zn and Cu at about ten times the background levels of Pb. Collembola were sampled in 2006 (July, September, November) using the transect method: 2,475 individuals from 34 species of Collembola were collected from 210 samples of soil and litter. Numerical densities differed significantly between the studied sites.The influence of air pollutants on the springtail fauna was visible at the species richness diversity and soil pollution levels. Species richness was lowest in the most contaminated site (Cismigiu, 11 species), which presented an increase in springtails abundances, though. Some species may become resistant to pollution and occur in high numbers of individuals in polluted sites, which makes them a good bioindicator of pollutants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A comparative study of elements deposited on tree bark was carried out for urban and periurban areas of two of the most important cities in Argentina. The content of Fe, Mg, Al, Mn, Zn, Pb, Ba, Cr, Hg, Cu, Ni, Cd and Sb was determined by inductively coupled plasma atomic emission spectrometry (ICP-OES) in Morus alba tree bark collected in the cities of Buenos Aires and Mendoza. The main air pollutants detected in the Buenos Aires urban area were Ba, Cr, Cu and Ni and indicate significative difference from the Mendoza urban and periurban areas. Significantly, higher concentrations of Zn, Ba, Cr and Cu were recorded in the periurban area of the city of Buenos Aires than in Mendoza. Bark samples were strongly influenced by dust and show Al, Fe, Mg and other element accumulations that indicate that soil particles were carried out by wind. Elements like Ba and Zn, commonly linked to traffic emissions, showed the highest concentrations in the Buenos Aires metropolitan area, possibly due to more intensive vehicular traffic. Our results indicated that intensity of vehicular traffic and not city structure is responsible for air pollution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACTWhile a number of papers have shown that subway systems have an impact on the air quality through the release of particulate matters, no information about the impact of such particles on tree attributes is available. Tree leaves from three different species from the exit side of a subway station in Rio de Janeiro, Brazil, were more asymmetrical than leaves from the entrance side. This leaves also presenting changes in leaves cuticle and chlorophyll content.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Varied electrostatics experiments followed Benjamin Franklin's pioneering atmospheric investigations. In Knightsbridge, Central London, John Read (1726–1814) installed a sensing rod in the upper part of his house and, using a pith ball electrometer and Franklin chimes, monitored atmospheric electricity from 1789 to 1791. Atmospheric electricity is sensitive to weather and smoke pollution. In calm weather conditions, Read observed two daily electrification maxima in moderate weather, around 9 am and 7 pm. This is likely to represent a double diurnal cycle in urban smoke. Before the motor car and steam railways, one source of the double maximum smoke pattern was the daily routine of fire lighting for domestic heating.