857 resultados para ultrasound assisted dissolution-evaporation
Resumo:
Meta-analysis of prospective studies shows that quantitative ultrasound of the heel using validated devices predicts risk of different types of fracture with similar performance across different devices and in elderly men and women. These predictions are independent of the risk estimates from hip DXA measures.Introduction Clinical utilisation of heel quantitative ultrasound (QUS) depends on its power to predict clinical fractures. This is particularly important in settings that have no access to DXA-derived bone density measurements. We aimed to assess the predictive power of heel QUS for fractures using a meta-analysis approach.Methods We conducted an inverse variance random effects meta-analysis of prospective studies with heel QUS measures at baseline and fracture outcomes in their follow-up. Relative risks (RR) per standard deviation (SD) of different QUS parameters (broadband ultrasound attenuation [BUA], speed of sound [SOS], stiffness index [SI], and quantitative ultrasound index [QUI]) for various fracture outcomes (hip, vertebral, any clinical, any osteoporotic and major osteoporotic fractures) were reported based on study questions.Results Twenty-one studies including 55,164 women and 13,742 men were included in the meta-analysis with a total follow-up of 279,124 person-years. All four QUS parameters were associated with risk of different fracture. For instance, RR of hip fracture for 1 SD decrease of BUA was 1.69 (95% CI 1.43-2.00), SOS was 1.96 (95% CI 1.64-2.34), SI was 2.26 (95%CI 1.71-2.99) and QUI was 1.99 (95% CI 1.49-2.67). There was marked heterogeneity among studies on hip and any clinical fractures but no evidence of publication bias amongst them. Validated devices from different manufacturers predicted fracture risks with similar performance (meta-regression p values > 0.05 for difference of devices). QUS measures predicted fracture with a similar performance in men and women. Meta-analysis of studies with QUS measures adjusted for hip BMD showed a significant and independent association with fracture risk (RR/SD for BUA = 1.34 [95%CI 1.22-1.49]).Conclusions This study confirms that heel QUS, using validated devices, predicts risk of different fracture outcomes in elderly men and women. Further research is needed for more widespread utilisation of the heel QUS in clinical settings across the world.
Resumo:
Introduction: A standardized three-dimensional ultrasonographic (3DUS) protocol is described that allows fetal face reconstruction. Ability to identify cleft lip with 3DUS using this protocol was assessed by operators with minimal 3DUS experience. Material and Methods: 260 stored volumes of fetal face were analyzed using a standardized protocol by operators with different levels of competence in 3DUS. The outcomes studied were: (1) the performance of post-processing 3D face volumes for the detection of facial clefts; (2) the ability of a resident with minimal 3DUS experience to reconstruct the acquired facial volumes, and (3) the time needed to reconstruct each plane to allow proper diagnosis of a cleft. Results: The three orthogonal planes of the fetal face (axial, sagittal and coronal) were adequately reconstructed with similar performance when acquired by a maternal-fetal medicine specialist or by residents with minimal experience (72 vs. 76%, p = 0.629). The learning curve for manipulation of 3DUS volumes of the fetal face corresponds to 30 cases and is independent of the operator's level of experience. Discussion: The learning curve for the standardized protocol we describe is short, even for inexperienced sonographers. This technique might decrease the length of anatomy ultrasounds and improve the ability to visualize fetal face anomalies.
Resumo:
A new hypothesis is formulated to explain the development of rapakivi texture in and around the mafic enclaves of porphyritic granitoids, i.e. in environments involving magma mixing and mingling. The formation of a plagioclase mantle around alkali feldspar megacrysts is attributed to the localized presence of a melt resulting from the reaction of these megacrysts, with host hybrid magma with which they are in disequilibrium. This feldspathic melt adheres to the resorbed crystals and is virtually immiscible with the surrounding magma. Its composition is modified in terms of the relative proportions of K2O, Na2O, and CaO through selective diffusion of these elements, thus allowing the specific crystallization of andesine. With decreasing temperature, the K-feldspar, again stable, crystallizes along with the plagioclase, leading to mixed mantle structures.
Resumo:
In recent years, management of abdominal pain in emergency care units (ECU) has undergone a radical change. Chronic work overload of ECU and increase in severity and complexity of cases required an optimal medical imaging method, such as ultrasound, to establish an accurate diagnosis as quickly as possible. A great variety of causes may cause acute abdominal pain and the role of sonography is to accurately distinguish between these aetiologies. For the application of sonography, perhaps more so than with other imaging methods, a perfect knowledge of sonographical characteristics and technical possibilities is essential to achieve an optimal answer. The purpose of this review is to present and discuss the sonographic characteristics of extra-digestive causes of acute abdominal pain such as splenic infarction, thoracic pathologies, urinary and gynaecologic diseases or retroperitoneal pathologies.
Resumo:
Migmatites produced by low-pressure anatexis of basic dykes are found in a contact metamorphic aureole around a pyroxenite-gabbro intrusion (PX2), on Fuerteventura. Dykes outside and inside the aureole record interaction with meteoric water, with low or negative delta O-18 whole-rock values (+0.2 to -3.4 parts per thousand), decreasing towards the contact. Recrystallised plagioclase, diopside, biotite and oxides, from within the aureole, show a similar evolution with lowest delta O-18 values (-2.8, -4.2, - 4.4 and -7.6 parts per thousand, respectively) in the migmatite zone, close to the intrusion. Relict clinopyroxene phenocrysts preserved in all dykes, retain typically magmatic delta O-18 values up to the anatectic zone, where the values are lower and more heterogeneous. Low delta O-18 values, decreasing towards the intrusion, can be ascribed to the advection of meteoric water during magma emplacement, with increasing fluid/rock ratios (higher dyke intensities towards the intrusion acting as fluid-pathways) and higher temperatures promoting increasing exchange during recrystallisation.
Resumo:
OBJECTIVE: Prospective studies have shown that quantitative ultrasound (QUS) techniques predict the risk of fracture of the proximal femur with similar standardised risk ratios to dual-energy x-ray absorptiometry (DXA). Few studies have investigated these devices for the prediction of vertebral fractures. The Basel Osteoporosis Study (BOS) is a population-based prospective study to assess the performance of QUS devices and DXA in predicting incident vertebral fractures. METHODS: 432 women aged 60-80 years were followed-up for 3 years. Incident vertebral fractures were assessed radiologically. Bone measurements using DXA (spine and hip) and QUS measurements (calcaneus and proximal phalanges) were performed. Measurements were assessed for their value in predicting incident vertebral fractures using logistic regression. RESULTS: QUS measurements at the calcaneus and DXA measurements discriminated between women with and without incident vertebral fracture, (20% height reduction). The relative risks (RRs) for vertebral fracture, adjusted for age, were 2.3 for the Stiffness Index (SI) and 2.8 for the Quantitative Ultrasound Index (QUI) at the calcaneus and 2.0 for bone mineral density at the lumbar spine. The predictive value (AUC (95% CI)) of QUS measurements at the calcaneus remained highly significant (0.70 for SI, 0.72 for the QUI, and 0.67 for DXA at the lumbar spine) even after adjustment for other confounding variables. CONCLUSIONS: QUS of the calcaneus and bone mineral density measurements were shown to be significant predictors of incident vertebral fracture. The RRs for QUS measurements at the calcaneus are of similar magnitude as for DXA measurements.
Resumo:
A group of experts on schistosomiasis and ultrasonography discussed the experiences and results obtained with the Niamey-Belo Horizonte Protocol on Ultrasonography in Schistosomiasis. A series of recomendations about qualitative and quantitative data obtained by ultrasound in studies performed in Africa and Brazil are presented. Imunological, genetic and epidemiological studies must rely on ultrasound for the identification of patients with periportal thickening/fibrosis.
Resumo:
Click here to download PDF
Resumo:
BACKGROUND: Half of the patients with end-stage heart failure suffer from persistent atrial fibrillation (AF). Atrial kick (AK) accounts for 10-15% of the ejection fraction. A device restoring AK should significantly improve cardiac output (CO) and possibly delay ventricular assist device (VAD) implantation. This study has been designed to assess the mechanical effects of a motorless pump on the right chambers of the heart in an animal model. METHODS: Atripump is a dome-shaped biometal actuator electrically driven by a pacemaker-like control unit. In eight sheep, the device was sutured onto the right atrium (RA). AF was simulated with rapid atrial pacing. RA ejection fraction (EF) was assessed with intracardiac ultrasound (ICUS) in baseline, AF and assisted-AF status. In two animals, the pump was left in place for 4 weeks and then explanted. Histology examination was carried out. The mean values for single measurement per animal with +/-SD were analysed. RESULTS: The contraction rate of the device was 60 per min. RA EF was 41% in baseline, 7% in AF and 21% in assisted-AF conditions. CO was 7+/-0.5 l min(-1) in baseline, 6.2+/-0.5 l min(-1) in AF and 6.7+/-0.5 l min(-1) in assisted-AF status (p<0.01). Histology of the atrium in the chronic group showed chronic tissue inflammation and no sign of tissue necrosis. CONCLUSIONS: The artificial muscle restores the AK and improves CO. In patients with end-stage cardiac failure and permanent AF, if implanted on both sides, it would improve CO and possibly delay or even avoid complex surgical treatment such as VAD implantation.
Resumo:
A major advance in our understanding of the natural history of Schistosoma haematobium-related morbidity has come through the introduction of the portable ultrasound machines for non-invasive examination of the kidneys and bladder. With the use of generators or battery packs to supply power in non-clinical field settings, and with the use of instant photography or miniaturized thermal printers to record permanent images, it is possible to examine scores of individuals in endemic communities every day. Broad-based ultrasound screening has allowed better definition of age-specific disease risks in urinary schistosomiasis. Results indicate that urinary tract abnormalities are common (18% overall prevalence) in S. haematobium transmission areas, with a 2-4% risk of either severe bladder abnormality or advanced ureteral obstruction. In longitudinal surveys, ultrasound studies have shown that praziquantel and metrifonate therapy are rapidly effective in reversing urinary tract abnormalities among children. The benefits of treating adults are less well known, but research in progress should help to define this issue. Similarly, the prognosis of specific ultrasound findings needs to be clarified, and the ease of sonographic examination will make such long-term follow-up studies feasible. In summary, the painless, quick, and reproducible ultrasound examination has become an essential tool in the study of urinary schistosomiasis.
Resumo:
In endemic areas with low prevalence and low intensity of infection, the diagnosis of hepatic pathology due to the Schistosoma mansoni infection is very difficult. In order to establish the hepatic morbidity, a double-blind study was achieved in Venezuelan endemic areas, with one group of patients with schistosomiasis and the other one of non-infected people, that were evaluated clinically and by abdominal ultrasound using the Cairo classification. Schistosomiasis diagnosis was established based on parasitologic and serological tests. The increase of the hepatic size at midclavicular and midsternal lines (in hepatometry) and the hard liver consistency were the clinical parameters able to differentiate infected persons from non infected ones, as well as the presence of left lobe hepatomegaly detected by abdominal ultrasound. The periportal thickening, especially the mild form, was frequent in all age groups in both infected and uninfected patients. There was not correlation between the intensity of infection and ultrasound under the current circumstances. Our data suggest that in Venezuela, a low endemic area of transmission of schistosomiasis, the hepatic morbidity is mild and uncommon. The Cairo classification seems to overestimate the prevalence of periportal pathology. The specificity of the method must be improved, especially for the recognition of precocious pathology. Other causes of hepatopathies must be investigated.
Resumo:
Purpose: Extension of retinoblastoma cells anterior to the vitreous surface is a criteria used to categorize retinoblastomas in Group E. In some cases, the assessment of anterior chamber invasion is readily visible by slit lamp examination, but in other cases, invasion of the posterior chamber is clinically difficult to determinate. Ultrasound biomicroscopy (UBM) allows high-resolution images of the anterior segment and structures normally hidden from clinical visualization such as ciliary body, zonule or posterior chamber. This prompted us to evaluate the value of UBM in the assessment of posterior and anterior chamber involvement in patients with peripheral extending retinoblastomas. Methods: We retrospectively reviewed all retinoblastoma cases that underwent enucleation in our institution from 1.1996 till 12.2009 in which UBM ( 35-MHz or 50-MHz) evaluation was available. The UBM results were compared with the histopathological data. Results: From 1.1996 till 12.2009, 146 enucleations were performed in our institution. UBM information was available in 18 cases. There were 8 males and 10 females. The mean age was 4 years old. UBM allowed correct assessement of posterior chamber invasion in 15 cases (13 cases with retinoblastoma in the posterior chamber and 2 cases without retinoblastoma in the posterior chamber). There was a significant correlation between the presence of retinoblastoma cells in the posterior chamber detected by UBM and the histopathological confirmation of posterior chamber involvement (p=0,0008). The sensitivity of UBM in the assessment of posterior chamber invasion by retinoblastoma was 81% and the specificity 100%. UBM allowed correct assessment of anterior chamber invasion in 13 cases. The sensitivity of UBM for this purpose was 50% and the specificity 60 %. Conclusions: In selected cases of advanced retinoblastoma, UBM appears to represent a valuable tool in the evaluation of the precise extension of the disease. Although our series encompasses only a limited number of cases, the sensitivity and specificity of UBM in the assessment of retinoblastoma anterior extension is interesting. Further prospective multi-centered clinical studies would be necessary to better delineate the utility of this method in the precise categorization of retinoblastoma anterior extension