915 resultados para ultrasonic speed


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An ultrasonic density-measurement cell is experimentally characterized as a function of temperature. The measurement of propagation velocity and density of several liquids is performed in the 15 degrees C-40 degrees C temperature range. Results are compared to the tabulated values in the case of distilled water, showing an accuracy of 0.07% for the propagation velocity. The cell was tested with distilled water, alcohol, and homogenized milk, and density values are compared to those obtained with a pycnometer, showing 0.2% accuracy in density measurement for stabilized temperature and 0.4% accuracy under thermal gradient conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the accuracy of approximal caries detection comparing enhanced and unenhanced Sidexis CCD-based digital image with Ektaspeed Plus and INSIGHT films. Methods: Fifty-two extracted premolars were imaged under identical standardized geometric and exposure conditions. Four observers, using five points confidence scale, rated 104 approximal surfaces for the presence or absence of carious lesions by means of four image modalities: (1) observer enhanced; (2) unenhanced Sidexis displays; (3) E speed films and (4) F speed film. Histologic sections served as validating criterion for the presence and depth of carious lesions. Diagnostic accuracy was measured as the area beneath the ROC curve. Results: Mean ROC (receiver operating characteristic) curve areas for approximal surfaces were 0.865 (E speed), 0.856 (F speed), 0.816 (unenhanced Sidexis) and 0.776 (observer enhanced). There were no significant differences between unenhanced digital Sidexis and films. Observer enhanced Sidexis images exhibited a statistically significant lower diagnostic accuracy than the film images for two of the observers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. Cavity and tooth preparations generate heat because the use of rotary cutting instruments on dental tissues creates friction. Dental pulps cannot survive temperature increases greater than 5.5degreesC.Purpose. This study evaluated the efficiency of 3 different water flows for 2 different tooth preparation techniques to determine which are safe for use.Material and methods. Thermocouples were placed in the pulpal chambers of 30 bovine teeth, and 1 of 2 tooth preparation techniques was used: a low-load intermittent tooth preparation technique or a high-load tooth preparation technique without intervals. Water flows of 0, 30, and 45 mL/min were associated with each technique, for a total of 6 different groups. The results were analyzed with a 2-factor analysis of variance (P<.05).Results. Temperature increases with the high-load technique were 16.40&DEG;C without cooling (group 1), 11.68&DEG;C with 30 mL/min air-water spray cooling (group III), and 9.96&DEG;C with 45 mL/min cooling (group V). With the low-load tooth preparation technique, a 9.54&DEG;C increase resulted with no cooling (group II), a 1.56&DEG;C increase with 30 mL/min air-water spray cooling (group TV), and a 0.04&DEG;C decrease with 45 mL/min cooling (group VI). The low-load technique was associated with more ideal temperature changes.Conclusion. The results of this study confirm the necessity of using a low-load technique and water coolants during cavity and tooth preparation procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effect of using different mathematical models to describe the relationship between treadmill running speed and time to exhaustion. All models generated a value for an aerobic parameter (critical speed; S(critical)). 35 university students performed 5-7 constant-speed 0%-slope treadmill tests at speeds that elicited exhaustion in similar to 3 min to similar to 10 min. Speed and time data were fitted using 3 models: (1) a 2-parameter hyperbolic model; (2) a 3-parameter hyperbolic model; and (3) a hybrid 3-parameter hyperbolic + exponential model. The 2-parameter model generated values for S(critical) (mean (+/- SD): 186 +/- 33 m.min(-1)) and anaerobic distance capacity (ADC; 251 +/- 122 m) with a high level of statistical certainty (i.e., with small SEEs). The 3-parameter models generated parameter estimates that were unrealistic in magnitude and/or associated with large SEEs and little statistical certainty. Therefore, it was concluded that, for the range of exercise durations used in the present study, the 2-parameter model is preferred because it provides a parsimonious description of the relationship between velocity and time to fatigue, and it produces parameters of known physiological significance, with excellent confidence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an experimental study on the life of abrasive discs in cut-off type operations with two conditions of cutting speed. The cutting time is shown with a comparative analysis of the cutting speed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurements of ultrasonic attenuation and velocity in milk and low concentration water-in-oil (W/O) emulsion were conducted, using a measurement cell with a double-element transducer that eliminates diffraction losses. The milk is characterized by the attenuation coefficient, while in the case of water-in-oil emulsions, the characterization is best represented by the propagation velocity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a high speed current mode CMOS comparator. The comparator was optimized for allows wide range input current 1mA, ±0.5uA resolution and has fast response. This circuit was implemented with 0.8μm CMOS n-well process with area of 120μm × 105μm and operates with 3.3V(±1.65V).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work it is introduced a new approach to calculate the density of liquids in terms of the energies of the acoustic signals. This method is compared to other methods in the time domain (peak-to-peak amplitudes) and frequency domain magnitudes at a single frequency. It is used a measurement cell based on a multiple reflection technique, and it is developed an acoustic model for the cell. Simulations and experiments using several liquids are presented, showing that the energy method a less sensitive to noise than the other techniques. The relative errors in the density are smaller than 0.2% when compared to the values measured with a pycnometer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The natural naphthopyranones paepalantine (1), paepalantine-9O-β-D-glucopyranoside (2) and paepalantine-9-O-β-D-allopyranosyl-(1→6)-O-β-D-glucopyranoside (3) were separated in a preparative scale from the ethanolic extract of the capitula of Paepalanthus bromelioides by high-speed counter-current chromatography (HSCCC). The solvent system used was composed of water-ethanol-ethyl acetate-hexane (10:4:10:4, v/v/v/v). This technique led to the separation of the three different naphthopyranone glycosides in pure form in approximately 7 hours. Paepalantine showed a good antioxidant activity when assayed by the DPPH radical spectrophotometric assay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This study measured the water flow commonly used in high-speed handpieces to evaluate the water flow's influence on temperature generation. Different flow speeds were evaluated between turbines that had different numbers of cooling apertures. Method and materials: Two water samples were collected from each high-speed handpiece at private practices and at the School of Dentistry at São José dos Campos. The first sample was collected at the customary flow and the second was collected with the terminal opened for maximum flow. The two samples were collected into weighed glass receptacles after 15 seconds of turbine operation. The glass receptacles were reweighed and the difference between weights was recorded to calculate the water flow in mL/min and for further statistical analysis. Results: The average water flow for 137 samples was 29.48 mL/min. The flow speeds obtained were 42.38 mL/min for turbines with one coolant aperture; 34.31 mL/min for turbines with two coolant apertures; and 30.44 mL/min for turbines with three coolant apertures. There were statistical differences between turbines with one and three coolant apertures (Tukey-Kramer multiple comparisons test with P < .05). Conclusion: Turbine handpieces with one cooling aperture distributed more water for the burs than high-speed handpieces with more than one aperture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study analyzed the relationship between critical speed (CS) and maximal speed for 30 min (S30) in swimmers of ages 10-15 years. Fifty-one swimmers were divided by chronological age (10-12 years = G10-12, 13-15 years = G13-15), sexual maturation (pubic hair stages; P1-P3 and P4-P5), and gender (M = boys, F = girls). The CS was determined through the slope of the linear regression between the distances (100, 200, and 400 m) and participants' respective times. CS and S30 were similar in the younger (G10-12M = 0.97 vs. 0.97 m/s, and G10-12F = 1.01 vs. 0.97 m/s, respectively), and older swimmers (G13-15M = 1.10 vs. 1.07 m/s and G13-15F = 0.93 vs. 0.91 m/s, respectively). In conclusion, the CS can be used in young swimmers for the evaluation of aerobic capacity, independent of gender and age. © 2005 Human Kinetics, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-speed countercurrent chromatography (HSCCC) is a leading method for the fast separation of natural products from plants. It was used for the preparative isolation of two flavone monoglucosides present in the capitula of Eriocaulon ligulatum (Veil.) L.B.Smith (Eriocaulaceae). This species, known locally as botão-dourado, is exported to Europe, Japan and North America as an ornamental species, constituting an important source of income for the local population of Minas Gerais State, Brazil. The solvent system, optimized in tests prior to the HSCCC run, consisted of the two phases of the mixture ethyl acetate: n-propanol: water (140:8:80, v/v/v), which led to the successful separation of 6-methoxyluteolin-7-O-β-D-allopyranoside and 6-methoxyapigenin-7-O-β-D-allopyranoside in only 3 hours. The two flavonoids were identified by NMR (1-D and 2-D) and ESI-MS, comparing their spectra with published data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An ultrasonic densitometer is experimentally characterized as a function of temperature. The measurement of propagation velocity and density of several liquids is performed in the 15 to 40°C temperature range. Results are compared to tabulated values in the case of distilled water, showing accuracy of 0.07% for the propagation velocity. Density values are compared to those obtained with a pycnometer, showing 0.2% accuracy in density measurement for stabilized temperature and 0.4% under thermal gradient conditions.