1000 resultados para tunneling current


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scanning tunneling microscopy/spectroscopy studies were carried out on single crystals of colossal magnetoresistive manganite Pr0. 68Pb0.32MnO3 at different temperatures in order to probe their spatial homogeneity across the metal-insulator transition temperature TM-I(similar to 255 K). A metallic behavior of the local conductance was observed for temperatures T < TM-I. Zero bias conductance (dI/dV)v=(0), which is directly proportional to the local surface density of states at the Fermi level, shows a single distribution at temperatures T < 200 K suggesting a homogeneous electronic phase at low temperatures. In a narrow temperature window of 200 K < T < TM-I, however, an inhomogeneous distribution of (dI/dV)v=(0) has been observed. This result gives evidence for phase separation in the transition region in this compound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A constant switching frequency current error space vector-based hysteresis controller for two-level voltage source inverter-fed induction motor (IM) drives is proposed in this study. The proposed controller is capable of driving the IM in the entire speed range extending to the six-step mode. The proposed controller uses the parabolic boundary, reported earlier, for vector selection in a sector, but uses simple, fast and self-adaptive sector identification logic for sector change detection in the entire modulation range. This new scheme detects the sector change using the change in direction of current error along the axes jA, jB and jC. Most of the previous schemes use an outer boundary for sector change detection. So the current error goes outside the boundary six times during sector change, in one cycle,, introducing additional fifth and seventh harmonic components in phase current. This may cause sixth harmonic torque pulsations in the motor and spread in the harmonic spectrum of phase voltage. The proposed new scheme detects the sector change fast and accurately eliminating the chance of introducing additional fifth and seventh harmonic components in phase current and provides harmonic spectrum of phase voltage, which exactly matches with that of constant switching frequency voltage-controlled space vector pulse width modulation (VC-SVPWM)-based two-level inverter-fed drives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

H-1 NMR spin-lattice relaxation time measurements have been carried out in [(CH3)(4)N](2)SeO4 in the temperature range 389-6.6K to understand the possible phase transitions, internal motions and quantum rotational tunneling. A broad T, minimum observed around 280K is attributed to the simultaneous motions of CH3 and (CH3)(4)N groups. Magnetization recovery is found to be stretched exponential below 72 K with varying stretched exponent. Low-temperature T-1 behavior is interpreted in terms of methyl groups undergoing quantum rotational tunneling. (c) 2007 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The national resuscitation guidelines were published in Finland in 2002 and are based on international guidelines published in 2000. The main goal of the national guidelines, available on the Internet free of charge, is early defibrillation by nurses in an institutional setting. Aim: To study possible changes in cardiopulmonary resuscitation (CPR) practices, especially concerning early defibrillation, nurses and students attitudes of guideline implementation and nurses and students ability to implement the guideline recommendations in clinical practices after publication of the Current Care (CC) guidelines for CPR 2002. Material and methods: CPR practices in Finnish health centres; especially concerning rapid defibrillation programmes, as well as the implementation of CC guidelines for CPR was studied in a mail survey to chief physicians of every health centre in Finland (Study I). The CPR skills using an automated external defibrillator (AED) were compared in a study including Objective stuctured clinical examination (OSCE) of resuscitation skills of nurses and nursing students in Finnish and Swedish hospital and institution (Studies II, III). Attitudes towards CPR-D and CPR guidelines among medical and nursing students and secondary hospital nurses were studied in surveys (Studies IV, V). The nurses receiving different CPR training were compared in a randomized trial including OSCE of CPR skills of nurses in Finnish Hospital (Study VI). Results: Two years after the publication, 40.7% of Finnish health centres used national resuscitation guidelines. The proportion of health centres having at least one AED (66%) and principle of nurse-performed defibrillation without the presence of a physician (42%) had increased. The CPR-D training was estimated to be insufficient regarding basic life support and advanced life support in the majority of health centres (Study I). CPR-D skills of nurses and nursing students in two specific Swedish and Finnish hospitals and institutions (Study II and III) were generally inadequate. The nurses performed better than the students and the Swedish nurses surpassed the Finnish ones. Geriatric nurses receiving traditional CPR-D training performed better than those receiving an Internet-based course but both groups failed to defibrillate within 60 s. Thus, the performance was not satisfactory even two weeks after traditional training (Study VI). Unlike the medical students, the nursing students did not feel competent to perform procedures recommended in the cardiopulmonary resuscitation guidelines including the defibrillation. However, the majority of nursing students felt confident about their ability to perform basic life support. The perceived ability to defibrillate correlated significantly with a positive attitude towards nurse-performed defibrillation and negatively with fear of damaging the patient s heart by defibrillation (Study IV). After the educational intervention, the nurses found their level of CPR-D capability more sufficient than before and felt more confident about their ability to perform defibrillation themselves. A negative attitude toward defibrillation correlated with perceived negative organisational attitudes toward cardiopulmonary resuscitation guidelines. After CPR-D education in the hospital, the majority (64%) of nurses hesitated to perform defibrillation because of anxiety and 27 % hesitated because of fear of injuring the patient. Also a negative personal attitude towards guidelines increased markedly after education (Study V). Conclusions: Although a significant change had occurred in resuscitation practices in primary health care after publication of national cardiopulmonary resuscitation guidelines the participants CPR-D skills were not adequate according to the CPR guidelines. The current way of teaching is unlikely to result in participants being able to perform adequate and rapid CPR-D. More information and more frequent training are needed to diminish anxiety concerning defibrillation. Negative beliefs and attitudes toward defibrillation affect the nursing students and nurses attitudes toward cardiopulmonary resuscitation guidelines. CPR-D education increased the participants self-confidence concerning CPR-D skills but it did not reduce their anxiety. AEDs have replaced the manual defibrillators in most institutions, but in spite of the modern devices the anxiety still exists. Basic education does not provide nursing students with adequate CPR-D skills. Thus, frequent training in the workplace has vital importance. This multi-professional program supported by the administration might provide better CPR-D skills. Distance learning alone cannot substitute for traditional small-group learning, tutored hands-on training is needed to learn practical CPR-D skills. Standardized testing would probably help controlling the quality of learning. Training of group-working skills might improve CPR performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bhatnagar and Rathna (Quar. Journ. Mech. Appl. Maths., 1963,16, 329) investigated the flows of Newtonian, Reiner-Rivlin and Rivlin-Ericksen fluids between two rotating coaxial cones. In case of the last two types of fluids, they predicted the breaking of secondary flow field in any meridian plane. We find that such breaking is avoided by the application of a sufficiently strong azimuthal magnetic field arising from a line current along the axis of the cones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present note we have studied the harmonic and anharmonic oscillations of cylindrical plasma using Lagrangian formalism. In order to study the harmonic oscillations, the equations are linearized and the resulting equation for the displacement has been numerically solved. For situations present in thermonuclear reactors, the presence of axial magnetic field is found necessary to make the periods of oscillation to become comparable with the time required for the thermonuclear reactions to set in. A detailed analysis of the anharmonic oscillations reveals that the significant interaction is between the first and the second mode. The fundamental period of anharmonic oscillation is more than the corresponding period of harmonic oscillations by 9·2%. Graphs have been drawn for the amplitudes of relative variations in density and magnetic field and of the time-varying part of anharmonic oscillation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a search for the flavor-changing neutral-current decay D0 \to {\mu}+ {\mu}- in pp collisions at \surd s = 1.96 TeV using 360 pb-1 of integrated luminosity collected by the CDF II detector at the Fermilab Tevatron collider. A displaced vertex trigger selects long-lived D0 candidates in the {\mu}+ {\mu}-, {\pi}+{\pi}-, and K-{\pi}+ decay modes. We use the Cabibbo-favored D0 \to K-{\pi}+ channel to optimize the selection criteria in an unbiased manner, and the kinematically similar D0 \to{\pi}+ {\pi}- channel for normalization. We set an upper limit on the branching fraction (D0 --> {\mu}+ {\mu}-)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atomically resolved scanning tunneling microscopy was conducted on cleaved single crystals of the cubic perovskite Pr0.68Pb0.32MnO3.Several different surface configurations could be resolved including a frequent square arrangement with atomic distances in excellent agreement to the bulk lattice constant of the cubic structure. We also observed stripe formation and a surface reconstruction. The latter is likely related to a polar rare earth-oxygen terminated surface. (C) 2010 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents time-domain characteristics of induced current and voltage on a rocket in the presence of its exhaust plume when an electromagnetic (EM) wave generated by a nearby lightning discharge is incident on it. For the EM-field interaction with the rocket, the finite-difference time-domain technique has been used. The distributed electrical parameters, such as capacitance and inductance of the rocket and its exhaust plume, are computed using the method of moments technique. For the electrical characterization of the exhaust plume, the computational fluid dynamics technique has been used. The computed peak value of the electrical conductivity of the exhaust plume is 0.12 S/m near the exit plane and it reduces to 0.02 S/m at the downstream end. The relative permittivity varies from 0.91 to 0.99. The exhaust plume behaves as a good conductor for EM fields with frequencies less than 2.285 GHz. It has been observed that the peak value of the induced current on the rocket gets enhanced significantly in the presence of the conducting exhaust plume for the rocket and exhaust plume dimensions and parameters studied. The magnitude of the time-varying induced current at the tail is much more than that of any other section of the rocket.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents time-domain characteristics of induced current and voltage on a rocket in the presence of its exhaust plume when an electromagnetic (EM) wave generated by a nearby lightning discharge is incident on it. For the EM-field interaction with the rocket, the finite-difference time-domain technique has been used. The distributed electrical parameters, such as capacitance and inductance of the rocket and its exhaust plume, are computed using the method of moments technique. For the electrical characterization of the exhaust plume, the computational fluid dynamics technique has been used. The computed peak value of the electrical conductivity of the exhaust plume is 0.12 S/m near the exit plane and it reduces to 0.02 S/m at the downstream end. The relative permittivity varies from 0.91 to 0.99. The exhaust plume behaves as a good conductor for EM fields with frequencies less than 2.285 GHz. It has been observed that the peak value of the induced current on the rocket gets enhanced significantly in the presence of the conducting exhaust plume for the rocket and exhaust plume dimensions and parameters studied. The magnitude of the time-varying induced current at the tail is much more than that of any other section of the rocket.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The transition time associated with the time-variation of the voltage across a two-terminal diaphragm-less solion in response to a step-current stimulus has been studied experimentally. A theoretical analysis has also been made by solving the diffusion problem under the appropriate initial and boundary conditions. The behaviour of the theoretically predicted transition times is in agreement with the observed behaviour. The systems under study have been shown to be different from those used hitherto in thin-layer chronopotentiometry.