861 resultados para titanium implant
Resumo:
The corrosion resistance of the new Ti-6Al-4V-1Zr alloy in comparison with ternary Ti-6Al-4V alloy in Ringer-Brown solution and artificial Carter-Brugirard saliva of different pH values was studied. In Ringer-Brown solution, the new alloy presented an improvement of all electrochemical parameters due to the alloying with Zr; also, impedance spectra revealed better protective properties of its passive layer. In Carter-Brugirard artificial saliva, an increase of the passive film thickness was proved. Fluoride ions had a slight negative influence on the corrosion and ion release rates, without to affect the very good stability of the new Ti-6Al-4V-1Zr alloy.
Resumo:
Pure and Fe(III)-doped TiO2 suspensions were prepared by the sol gel method with the use of titanium isopropoxide (Ti(OPri)4) as precursor material. The properties of doped materials were compared to TiO2 properties based on the characterization by thermal analysis (TG-DTA and DSC), X-ray powder diffractometry and spectroscopy measurements (FTIR). Both undoped and doped TiO2 suspensions were used to coat metallic substrate as a mean to make thin-film electrodes. Thermal treatment of the precursors at 400ºC for 2 h in air resulted in the formation of nanocrystalline anatase TiO2. The thin-film electrodes were tested with respect to their photocatalytic performance for degradation of a textile dye in aqueous solution. The plain TiO2 remains as the best catalyst at the conditions used in this report.
Resumo:
Fiber-reinforced composites (FRCs) are a new group of non-metallic biomaterials showing a growing popularity in many dental and medical applications. As an oral implant material, FRC is biocompatible in bone tissue environment. Soft tissue integration to FRC polymer material is unclear. This series of in vitro studies aimed at evaluating unidirectional E-glass FRC polymer in terms of mechanical, chemical, and biological properties in an attempt to develop a new non-metallic oral implant abutment alternative. Two different types of substrates were investigated: (a) Plain polymer (BisGMA 50%–TEGDMA 50%) and (b) Unidirectional FRC. The mechanical behavior of high fiber-density FRCs was assessed using a three-point bending test. Surface characterization was performed using scanning electron and spinning disk confocal microscopes. The surface wettability/energy was determined using sessile drop method. The blood response, including blood-clotting ability and platelet morphology was evaluated. Human gingival fibroblast cell responses - adhesion kinetics, adhesion strength, and proliferation activity - were studied in cell culture environment using routine test conditions. A novel tissue culture method was developed and used to evaluate porcine gingival tissue graft attachment and growth on the experimental composite implants. The analysis of the mechanical properties showed that there is a direct proportionality in the relationship between E-glass fiber volume fraction and toughness, modulus of elasticity, and load bearing capacity; however, flexural strength did not show significant improvement when high fiber-density FRC is used. FRCs showed moderate hydrophilic properties owing to the presence of exposed glass fibers on the polymer surface. Blood-clotting time was shorter on FRC substrates than on plain polymer. The FRC substrates also showed higher platelet activation state than plain polymer substrates. Fibroblast cell adhesion strength and proliferation rate were highly pronounced on FRCs. A tissue culture study revealed that gingival epithelium and connective tissue established an immediate close contact with both plain polymer and FRC implants. However, FRC seemed to guide epithelial migration outwards from the tissue/implant interface. Due to the anisotropic and hydrophilic nature of FRC, it can be concluded that this material enhances biological events related with soft tissue integration on oral implant surface.
Resumo:
The aim of this thesis was to identify the best grease removal technique with the application of low power of UV light to TiO2 coated grease filters. The treatment with various power series of ozone generating and ozone free lamps to normal grease filters and TiO2 coated grease filters were examined and the obtained results are compared to each other in this paper. The effect of ozone reaction was observed and compared with the effect of TiO2. The experiments were solely based on the photo oxidation and photo catalytic oxidation reactions. TiO2 is a green catalyst used in the photocatalytic reaction. Sunflower oil was used for grease production and tetracholoroethylene as a solvent. Grease samples were collected from the ventilation duct connected to the cooking hood system. Sample extraction was done in ultrasonic bath with the principle of sonication. The sample analysis was done by FTIR machine. The result determining the concentration of grease was the quantification of saturated C-H bonds in the chosen peak group of the spectrum. A very low power of UVC light functions perfectly with the Titanium dioxide. The experimental results have shown the combined treatment of titanium dioxide and UV light is an effective method in grease removal process. The photocatalytic reaction with titanium dioxide is better than photo oxidation reaction with ozone treatment. Photocatalytic reaction is environmentally friendly, energy efficient and economical.
Resumo:
The objective of this prospective study was to evaluate the efficacy and complications of the use of an intraocular sustained-release ganciclovir implant for the treatment of active cytomegalovirus (CMV) retinitis in AIDS patients. Thirty-nine eyes of 26 patients were submitted to ocular surgery. All patients underwent complete ocular examination before and after surgery. The surgical procedure was always done under local anesthesia using the same technique. The mean time for the surgical procedure was 20 min (range, 15 to 30 min). The average follow-up period was 3.7 months. Of all patient, only 4 presented recurrence of retinitis after 8, 8, 9 and 2 months, respectively. Three of them received a successful second implant. All 39 eyes of the 26 patients presented healing of retinitis as shown by clinical improvement evaluated by indirect binocular ophthalmoscopy and retinography. Retinitis healed within a period of 4 to 6 weeks in all patients, with clinical regression signs from the third week on. Six (15.4%) eyes developed retinal detachment. None of the patients developed CMV retinitis in the contralateral eye. The intraocular implant proved to be effective in controlling the progression of retinitis for a period of up to 8 months even in patients for whom systemic therapy with either ganciclovir or foscarnet or both had failed. The intraocular sustained-release ganciclovir implant proved to be a safe new procedure for the treatment of CMV retinitis, avoiding the systemic side effects caused by the intravenous medications and improving the quality of life of the patients.
Resumo:
Intracranial aneurysmal subarachnoid hemorrhage (aSAH) is a life-threatening condition requiring immediate neurocritical care. A ruptured aneurysm must be isolated from arterial circulation to prevent rebleeding. Open surgical clipping of the neck of the aneurysm or intra-arterial filling of the aneurysm sack with platinum coils are major treatment strategies in an acute phase. About 40% of the patients suffering from aSAH die within a year of the bleeding despite the intensive treatment. After aSAH, the patient may develop a serious complication called vasospasm. Major risk for the vasospasm takes place at days 5–14 after the primary bleeding. In vasospasm, cerebral arteries contract uncontrollably causing brain ischemia that may lead to death. Nimodipine (NDP) is used to treat of vasospasm and it is administrated intravenously or orally every four hours for 21 days. NDP treatment has been scientifically proven to improve patients’ clinical outcome. The therapeutic effect of L-type calcium channel blocker NDP is due to the ability to dilate cerebral arteries. In addition to vasodilatation, recent research has shown the pleiotropic effect of NDP such as inhibition of neuronal apoptosis and inhibition of microthrombi formation. Indeed, NDP inhibits cortical spreading ischemia. Knowledge of the pathophysiology of the vasospasm has evolved in recent years to a complex entity of early brain injury, secondary injuries and cortical spreading ischemia, instead of being pure intracranial vessel spasm. High NDP levels are beneficial since they protect neurons and inhibit the cortical spreading ischemia. One of the drawbacks of the intravenous or oral administration of NPD is systemic hypotension, which is harmful particularly when the brain is injured. Maximizing the beneficial effects and avoiding systemic hypotension of NDP, we developed a sustained release biodegradable NDP implant that was surgically positioned in the basal cistern of animal models (dog and pig). Higher concentrations were achieved locally and lower concentrations systemically. Using this treatment approach in humans, it may be possible to reduce incidence of harmful hypotension and potentiate beneficial effects of NDP on neurons. Intracellular calcium regulation has a pivotal role in brain plasticity. NDP blocks L-type calcium channels in neurons, substantially decreasing intracellular calcium levels. Thus, we were interested in how NDP affects brain plasticity and tested the hypothesis in a mouse model. We found that NDP activates Brain-derived neurotrophic factor (BDNF) receptor TrkB and its downstream signaling in a reminiscent of antidepressant drugs. In contrast to antidepressant drugs, NDP activates Akt, a major survival-promoting factor. Our group’s previous findings demonstrate that long-term antidepressant treatment reactivates developmental-type of plasticity mechanisms in the adult brain, which allows the remodeling of neuronal networks if combined with appropriate rehabilitation. It seems that NDP has antidepressant-like properties and it is able to induce neuronal plasticity. In general, drug induced neuronal plasticity has a huge potential in neurorehabilitation and more studies are warranted.
Resumo:
In order to understand the mechanisms of poor osseointegration following dental implants in type 2 diabetics, it is important to study the biological properties of alveolar bone osteoblasts isolated from these patients. We collected alveolar bone chips under aseptic conditions and cultured them in vitro using the tissue explants adherent method. The biological properties of these cells were characterized using the following methods: alkaline phosphatase (ALP) chemical staining for cell viability, Alizarin red staining for osteogenic characteristics, MTT test for cell proliferation, enzyme dynamics for ALP contents, radio-immunoassay for bone gla protein (BGP) concentration, and ELISA for the concentration of type I collagen (COL-I) in the supernatant. Furthermore, we detected the adhesion ability of two types of cells from titanium slices using non-specific immunofluorescence staining and cell count. The two cell forms showed no significant difference in morphology under the same culture conditions. However, the alveolar bone osteoblasts received from type 2 diabetic patients had slower growth, lower cell activity and calcium nodule formation than the normal ones. The concentration of ALP, BGP and COL-I was lower in the supernatant of alveolar bone osteoblasts received from type 2 diabetic patients than in that received from normal subjects (P < 0.05). The alveolar bone osteoblasts obtained from type 2 diabetic patients can be successfully cultured in vitro with the same morphology and biological characteristics as those from normal patients, but with slower growth and lower concentration of specific secretion and lower combining ability with titanium than normal ones.
Resumo:
A previous study showed that BMP-2 (bone morphogenetic protein-2) and wear debris can separately support osteoclast formation induced by the receptor activator of NF-κB ligand (RANKL). However, the effect of BMP-2 on wear debris-induced osteoclast formation is unclear. In this study, we show that neither titanium particles nor BMP-2 can induce osteoclast formation in RAW 264.7 mouse leukemic monocyte macrophage cells but that BMP-2 synergizes with titanium particles to enhance osteoclast formation in the presence of RANKL, and that at a low concentration, BMP-2 has an optimal effect to stimulate the size and number of multinuclear osteoclasts, expression of osteoclast genes, and resorption area. Our data also clarify that the effects caused by the increase in BMP-2 on phosphorylated SMAD levels such as c-Fos expression increased throughout the early stages of osteoclastogenesis. BMP-2 and titanium particles stimulate the expression of p-JNK, p-P38, p-IkB, and P50 compared with the titanium group. These data suggested that BMP-2 may be a crucial factor in titanium particle-mediated osteoclast formation.
Resumo:
Hydrogen (H2) fuel cells have been considered a promising renewable energy source. The recent growth of H2 economy has required highly sensitive, micro-sized and cost-effective H2 sensor for monitoring concentrations and alerting to leakages due to the flammability and explosiveness of H2 Titanium dioxide (TiO2) made by electrochemical anodic oxidation has shown great potential as a H2 sensing material. The aim of this thesis is to develop highly sensitive H2 sensor using anodized TiO2. The sensor enables mass production and integration with microelectronics by preparing the oxide layer on suitable substrate. Morphology, elemental composition, crystal phase, electrical properties and H2 sensing properties of TiO2 nanostructures prepared on Ti foil, Si and SiO2/Si substrates were characterized. Initially, vertically oriented TiO2 nanotubes as the sensing material were obtained by anodizing Ti foil. The morphological properties of tubes could be tailored by varying the applied voltages of the anodization. The transparent oxide layer creates an interference color phenomena with white light illumination on the oxide surface. This coloration effect can be used to predict the morphological properties of the TiO2 nanostructures. The crystal phase transition from amorphous to anatase or rutile, or the mixture of anatase and rutile was observed with varying heat treatment temperatures. However, the H2 sensing properties of TiO2 nanotubes at room temperature were insufficient. H2 sensors using TiO2 nanostructures formed on Si and SiO2/Si substrates were demonstrated. In both cases, a Ti layer deposited on the substrates by a DC magnetron sputtering method was successfully anodized. A mesoporous TiO2 layer obtained on Si by anodization in an aqueous electrolyte at 5°C showed diode behavior, which was influenced by the work function difference of Pt metal electrodes and the oxide layer. The sensor enabled the detection of H2 (20-1000 ppm) at low operating temperatures (50–140°C) in ambient air. A Pd decorated tubular TiO2 layer was prepared on metal electrodes patterned SiO2/Si wafer by anodization in an organic electrolyte at 5°C. The sensor showed significantly enhanced H2 sensing properties, and detected hydrogen in the range of a few ppm with fast response/recovery time. The metal electrodes placed under the oxide layer also enhanced the mechanical tolerance of the sensor. The concept of TiO2 nanostructures on alternative substrates could be a prospect for microelectronic applications and mass production of gas sensors. The gas sensor properties can be further improved by modifying material morphologies and decorating it with catalytic materials.
Resumo:
Methods to optimize healing through dietary strategies present an attractive option for patients, such that healing from delicate oral surgeries occurs as optimally as possible with minimal patient-meditated complications through improper food choices. This review discusses findings from studies that have investigated the role of diet, either whole foods or individual dietary components, on periodontal health and their potential role in wound healing after periodontal surgery. To date, research in this area has largely focused on foods or individual dietary components that may attenuate inflammation or oxidant stress, or foster de novo bone formation. These studies suggest that a wide variety of dietary components, including macronutrients and micronutrients, are integral for optimal periodontal health and have the potential to accelerate oral wound healing after periodontal procedures. Moreover, this review provides guidance regarding dietary considerations that may help a patient achieve the best possible outcome after a periodontal procedure.
Resumo:
Rapport de recherche
Resumo:
L’augmentation de la population âgée dans la société indique que les systèmes de soins de la santé font face à de nouveaux défis. Les hauts niveaux d’incapacité qui en résultent peuvent être réduits par les nouvelles technologies, la promotion de la santé ainsi que des stratégies de prévention. Les écrits scientifiques récents soulignent la supériorité des prothèses dentaires implanto-portées par rapport aux prothèses conventionnelles en termes de satisfaction et de qualité de la vie des patients. Cependant, il n'est toujours pas clair si ces avantages ont des effets positifs à long terme sur la santé orale et générale ainsi que sur la qualité de vie des populations âgées. Objectifs, Hypothèses : Notre but était de mesurer l’impact des prothèses mandibulaires retenues par 2 implants sur la qualité de vie associée à la santé bucco-dentaire et générale ainsi que sur la santé orale et la qualité du sommeil des aînés édentés. Nous avons évalué les hypothèses nulles suivantes : il n'y a aucune différence entre les individus portants des prothèses mandibulaires retenues par 2 implants (IODs) et ceux qui portent des prothèses conventionnelles (CDs), par rapport à la qualité de vie reliée à la santé bucco-dentaire et générale, la santé orale et la qualité du sommeil, un an après avoir reçu leurs nouvelles prothèses. Méthodes : Dans cette étude randomisée contrôlée, 255 aînés ont reçu au hasard IODs ou les CDs, les deux types de prothèses étant opposés à des prothèses maxillaires conventionnelles. La qualité de la vie reliée à la santé bucco-dentaire (OHRQoL) et la santé générale subjective ont été mesurées avec les questionnaires Oral Health Impact Profile (OHIP-20) et Short Form-36 (SF-36) en condition pré-traitement et après un an. La qualité du sommeil et la somnolence diurne ont été mesurées à l’aide du questionnaire Qualité de Sommeil de Pittsburg et de l'Échelle de Somnolence Epworth. La santé orale a été évaluée par un examen clinique. Les variables indépendantes étaient le sens de cohérence et le type de prosthèse, ainsi que des variables socio-démographiques. En utilisant des analyses statistiques bi et multi-factorielles, des comparaisons à l’intérieur d’un même groupe et entre deux groupes ont été effectuées. Résultats : Les différences pré et post traitement pour les cotes OHIP étaient significativement plus grandes pour le groupe IOD que le groupe CD (p<0.05). Le type de traitement et la cote pré-traitement étaient des facteurs significatifs à OHRQoL (p < 0.0001). Dans le groupe CD, il y avait une diminution significative par rapport aux cotes de «Physical Component Scores (PCS)», le fonctionnement physique, le rôle physique et la douleur physique entre les données pré-traitement et un an après le traitement, ce qui indique une diminution au niveau de la santé générale subjective. Dans le groupe IOD, une diminution statistiquement non significative a été remarquée par rapport à toutes les cotes des sous-échelles de SF-36, sauf pour la douleur physique. Le modèle final de régression a démontré qu’après ajustement pour les variables âge, sexe, statut marital et type de traitement, la cote totale finale d’OHIP et les données de bases de PCS prédisaient la cote finale de PCS (p < 0.0001). Aucune corrélation significative entre sens de cohérence et OHRQoL n'a été détectée (r =-0.1; p > 0.05). Les aînés porteurs des prothèses conventionnelles avaient presque 5 fois plus de chance d’avoir une stomatite prothétique que ceux portant des prothèses mandibulaires hybrides retenues par 2 implants (p < 0.0001). Les aînés ayant subjectivement une mauvaise santé générale avaient une qualité de sommeil moins bonne que ceux avec une meilleure santé générale subjective (p < 0.05). Les personnes qui avaient une OHRQoL moins bonne étaient presque 4 fois plus somnolentes pendant le jour que celles avec une meilleure OHRQoL (p=0.003, χ2; OR =3.8 CI 1.5 to 9.8). L'analyse de régression a montré que la santé générale subjective et OHRQoL prévoient la qualité du sommeil (p=0.022 et p=0.001, respectivement) et la somnolence diurne (p=0.017 et p=0.005, respectivement). Conclusions: Les résultats de cette étude suggèrent que, chez les aînés édentés, des prothèses mandibulaires hybrides retenues par deux implants amènent une amélioration significative de la qualité de vie reliée à la santé bucco-dentaire et maintiennent la sensation d’une meilleure santé physique. Des prothèses hybrides implanto-portées peuvent contribuer à la santé orale en réduisant les traumatismes infligés à la muqueuse orale et en contrôlant la stomatite prothétique. Les aînés édentés dont le niveau de qualité de vie reliée à la santé bucco-dentaire est bas, peuvent aussi avoir des troubles de qualité du sommeil.
Resumo:
Cette thèse examine le développement du langage des enfants sourds qui ont reçu un implant cochléaire (IC) en bas âge. Une première étude rapporte une revue systématique qui avait pour but d’évaluer les connaissances actuelles concernant le développement du vocabulaire et de la grammaire chez les enfants qui ont reçu un IC avant l’âge de trois ans. Vingt-huit études ont été sélectionnées; une analyse descriptive de même qu’une méta-analyse ont été effectuées séparément pour chaque aspect du langage évalué (vocabulaire et grammaire, aspect réceptif et expressif). Au résultat, en dépit de la variabilité observée dans les études, il appert que l’implant cochléaire influence positivement le développement langagier; toutefois, seule une minorité de participants aux études a atteint des niveaux de langage comparables à ceux d’enfants entendants de même âge chronologique. La majorité des enfants continuent de présenter divers degrés de retard de langage, tant au plan réceptif qu’expressif, et ce, après jusqu’à cinq années de port de l’appareil. Les résultats suggèrent aussi, malgré la variabilité observée dans les études, que les bénéfices langagiers sont influencés par le fait de recevoir l’implant à deux ans plutôt qu’à trois ans. À partir des tendances retrouvées dans la littérature, les habiletés de vocabulaire et de grammaire chez 27 enfants qui ont reçu l’implant cochléaire en bas âge (entre 8 et 28 mois) ont été comparées avec celles d’un groupe d’enfants entendants, en utilisant des outils d’évaluation standardisés. Alors que les résultats de groupe montrent que les enfants qui reçoivent un IC autour de l’âge de deux ans atteignent des niveaux de langage dans les limites de la normale, les résultats individuels d’un sous-groupe formé de enfants les plus âgés font état de quatre profils de développement, soit des niveaux de langage dans les limites de la normale pour l’ensemble des composantes, un retard généralisé à l’ensemble des composantes, des habiletés lexicales dans la norme assorti d’un retard morphosyntaxique et enfin un profil atypique montrant des disparités importantes à travers les composantes du langage. Dans trois des quatre profils, la compréhension des phrases était particulièrement faible. Ces résultats suggèrent que le fait de recevoir un implant cochléaire entre l’âge d’un et deux ans ne garantit pas l’atteinte de niveaux de langage dans les limites de la normale malgré une expérience de port de l’appareil d’une durée appréciable. Une étape antérieure du développement linguistique a été examinée de plus près dans la troisième étude. La taille et la composition du vocabulaire expressif de onze enfants ayant reçu un IC à un âge moyen de 15 mois ont été comparées à celles de l’échantillon d’enfants entendants ayant servi à établir les normes en français québécois pour le questionnaire Mots et énoncés des Inventaires MacArthur-Bates du développement de la communication (IMBDC). Les scores d’âge équivalent selon la taille totale du vocabulaire des enfants avec IC étaient supérieurs à l’âge auditif (correspondant à la durée de port de l’appareil) mais inférieurs à l’âge chronologique. La représentation grammaticale en fonction de la taille du vocabulaire des enfants avec IC suit la tendance observée dans la norme. Ces résultats suggèrent que le profil lexical des enfants avec implant est très similaire à celui des enfants entendants lorsque le nombre total de mots acquis est le même. Les résultats de cette thèse suggèrent que l’implant peut, de manière générale, avoir un effet « normalisant » sur le langage ; toutefois, il semble que l’amélioration de l’accès auditif ne suffise pas pour rattraper à coup sûr le niveau de langage des pairs entendants dans l’ensemble des composantes du langage. Alors que les habiletés lexicales se rapprochent du profil typique, les habiletés de compréhension morphosyntaxique sont fortement atteintes chez une majorité d’enfants, suggérant un profil apparenté à un trouble de langage.
Resumo:
La supériorité des prothèses mandibulaires retenues par deux implants (IODs) sur les prothèses conventionnelles (CDs) nécessitent d’être éclaircies notamment en rapport à leur influence sur la qualité de vie reliée à la santé bucco-dentaire (OHRQoL) ainsi que sur la stabilité de cet effet de traitement. De plus, l’influence des facteurs psychologiques, tel que le sens de cohérence (SOC), sur l’effet de traitement reste encore inconnue. Le but de cette étude est de déterminer l’amplitude de l’influence du port des IODs et des CDs sur l’OHRQoL et d’évaluer la stabilité de l’effet de traitement dans le temps, tout en prenant en considération le niveau du SOC. MÉTHODOLOGIE: Des participants édentés (n=172, âge moyen 71, SD = 4.5) ayant reçu des CDs ou des IODs ont été suivis sur une période de deux ans. L’OHRQoL a été évaluée à l’aide du questionnaire « Oral Health Impact Profile (OHIP -20) » et ce avant le traitement et à chacun des deux suivis. Le SOC a été évalué à l’aide du questionnaire « The Orientation to Life (SOC -13) » à chacun des deux suivis. Des analyses statistiques ont été effectuées pour évaluer les différences intra et entre groupes (analyses statistiques descriptives, bivariées et multivariées). RÉSULTATS: Une amélioration statistiquement significative de l’OHRQoL entre les statuts avant et après traitement a été notée dans les deux groupes (Wilks’s Lambda = 0.473, F (1,151) = 157.31, p < 0.0001). L’amplitude de l’effet du traitement IOD est 1.5 fois plus grande que celle du traitement CD. Ces résultats ont été stables pendant les deux années d’étude et ils n’ont pas été influencés par le SOC. CONCLUSION: Le traitement IOD amène une meilleure OHRQoL à long terme en comparaison avec le traitement CD et ce sans influence du niveau du SOC. Ces résultats sont cliniquement significatifs et confirment la supériorité des IODs sur les CDs.