991 resultados para thermal storage
Resumo:
This paper reports on the findings of a survey on OCI storage in people in Bahia, Brasil. In this survey 11 samples of adipose tissue were taken from people who underwent splenectomy for hepato splenic schistosomiasis. In these patients, total DDT averaged 10.66 ppm as compared to 4,83 ppm of total DDT found in presumably healthy people. The difference was statistically significant. It is considered that the increased DDT storage in patients with hepatosplenic schistosomiass may be the result of a reduced metabolzation of p,p'-DDT and reduced excretion of its metabolites. Another possíbility is the increased exposure to organochlorine nsectedes by hepatosplenc patients who frequently come from irrigation zones, where these compounds are more used in intensive cultivatíon.
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics
Resumo:
Dissertation presented to Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa for obtaining the master degree in Membrane Engineering
Resumo:
Four years after the first visit seventeen public health units were visited again and evaluated as to standards of storage recommended by the Brazilian Immunization Programme. In 100% of the units, refrigerators and proper inside location of vaccines in the refrigerator were adequatety or regularfy maintained and checked, respectively. However, when control of temperature was checked, onfy 64.7% presented adequate storage conditions. In 94.1 % of the units, health workers complained of lack of immediate technical support in emergency situations. In 55.2 % the titers vaccine samples of were under the minimal recommended potency. It is necessary that the factors concerning the cold chain be continualfy evaluated so that the quality of the vaccines that will be used is not affected.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Informática
Resumo:
Based on the presentation and discussion at the 3rd Winter School on Technology Assessment, December 2012, Universidade Nova de Lisboa (Portugal), Caparica Campus, PhD programme on Technology Assessment
Resumo:
Construction and Building Materials 49 (2013), 315-327
Resumo:
The influence of time and temperature on the storage of an alkaline antigen of L.major-like and L.(V.) braziliensis promastigotes added or not of a proteases inhibitor (PMSF) was evaluted by means of an IgG-ELISA. Antibodies in assays using L. major-like antigen stored at -20oC for 6 monsths had a statistically lower geometric mean titer (GMT) and different 95% confidence interval limits (CL) than antigens stored otherwise, as assessed by the "t" statistic. The PMSF L. major-like antigen after storage for 6 months at a temperature of 4oC had the same GMT and 95% CL displayed at time zero as well as when storage for 4 and 6 months at -20oC. Significant diferences were not found when L.(V.) braziliensis antigens were stored at times and temperatures mentioned; the PMSF antigen stored for 2 months at -70oC resulted in a lower serum GMT and 95% CL than any other, as assessed by the "t" statistic. Antigen performance did not show any statistical difference associated to the addition of PMSF within the same species; the largest difference between antigens was that between PMSF-L. (V.) braziliensis and L. major-like without PMSF.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Informática
Resumo:
Dissertation to obtain the degree of Doctor of Philosophy in Biomedical Engineering
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia Química e Bioquímica
Resumo:
This study aimed to evaluate the second-generation OptiMal test for malaria diagnosis under various storage conditions. It detected all the positive samples, except for two Plasmodium malariae samples. Further research evaluating diverse environmental conditions are important for ICT test applicability in Brazilian malaria areas.
Resumo:
One of the biggest challenges for humanity is global warming and consequently, climate changes. Even though there has been increasing public awareness and investments from numerous countries concerning renewable energies, fossil fuels are and will continue to be in the near future, the main source of energy. Carbon capture and storage (CCS) is believed to be a serious measure to mitigate CO2 concentration. CCS briefly consists of capturing CO2 from the atmosphere or stationary emission sources and transporting and storing it via mineral carbonation, in oceans or geological media. The latter is referred to as carbon capture and geological storage (CCGS) and is considered to be the most promising of all solutions. Generally it consists of a storage (e.g. depleted oil reservoirs and deep saline aquifers) and sealing (commonly termed caprock in the oil industry) formations. The present study concerns the injection of CO2 into deep aquifers and regardless injection conditions, temperature gradients between carbon dioxide and the storage formation are likely to occur. Should the CO2 temperature be lower than the storage formation, a contractive behaviour of the reservoir and caprock is expected. The latter can result in the opening of new paths or re-opening of fractures, favouring leakage and compromising the CCGS project. During CO2 injection, coupled thermo-hydro-mechanical phenomena occur, which due to their complexity, hamper the assessment of each relative influence. For this purpose, several analyses were carried out in order to evaluate their influences but focusing on the thermal contractive behaviour. It was finally concluded that depending on mechanical and thermal properties of the pair aquifer-seal, the sealing caprock can undergo significant decreases in effective stress.
Resumo:
High reflective paints (cool paints) are used on flat roofs to reduce heat gains from the incidence of solar radiation and thus improve the thermal comfort and energy efficiency of buildings, especially in summer periods. Given the application potential of these paints on vertical surfaces, a research study has been developed to evaluate the thermal performance of reflective paints on walls under real exposure conditions. Accordingly, different reflective paints have been applied as the final coating of an ETICS type solution, on the facades of a full scale experimental cell built at LNEC campus. For being applied in an ETICS system a paint has to fulfill several requirements, whether aesthetic or functional (such as the adhesion between the coating layers or the durability of the insulation), essential for its efficient performance. Since this construction coating system is subject to a prolonged sun exposure, various problems may arise, such as paint degradation or deterioration of the thermal insulation properties, particularly when dark colors are applied. To evaluate the thermal performance of the chosen paints, the method of non-destructive analysis by Infrared Thermography was used. Thermography allows knowing the temperature distribution of facades by measuring the radiation emitted by their surfaces. To complement the thermographic diagnosis, thermocouples were placed between the insulation and the paint system of the experimental cell. Additional laboratory tests allowed the characterization of the optical properties (reflectance and emittance) of the different reflective paints used in this study. The comparative analysis of the thermal performance of reflective and conventional paints revealed that the reflective paint allows a reduction of the facade surface temperature, reducing the risk of loss of insulating properties of the ETICS system and thus ensuring its longevity and functionality. The color of the paint used affects, naturally, the reflective ability of the surface and may have an important role in energy balance of the building. This paper also showed the potential of infrared thermography in the evaluation of the thermal performance of reflective paints.
Resumo:
Este trabalho foi efectuado com o apoio da Universidade de Lisboa, Instituto Superior de Agronomia com o Centro de Engenharia dos Biossistemas (CEER