985 resultados para safety monitoring


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Typically common embedded systems are designed with high resource constraints. Static designs are often chosen to address very specific use cases. On contrast, a dynamic design must be used if the system must supply a real-time service where the input may contain factors of indeterminism. Thus, adding new functionality on these systems is often accomplished by higher development time, tests and costs, since new functionality push the system complexity and dynamics to a higher level. Usually, these systems have to adapt themselves to evolving requirements and changing service requests. In this perspective, run-time monitoring of the system behaviour becomes an important requirement, allowing to dynamically capturing the actual scheduling progress and resource utilization. For this to succeed, operating systems need to expose their internal behaviour and state, making it available to the external applications, usually using a run-time monitoring mechanism. However, such mechanism can impose a burden in the system itself if not wisely used. In this paper we explore this problem and propose a framework, which is intended to provide this run-time mechanism whilst achieving code separation, run-time efficiency and flexibility for the final developer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural health monitoring has long been identified as a prominent application of Wireless Sensor Networks (WSNs), as traditional wired-based solutions present some inherent limitations such as installation/maintenance cost, scalability and visual impact. Nevertheless, there is a lack of ready-to-use and off-the-shelf WSN technologies that are able to fulfill some most demanding requirements of these applications, which can span from critical physical infrastructures (e.g. bridges, tunnels, mines, energy grid) to historical buildings or even industrial machinery and vehicles. Low-power and low-cost yet extremely sensitive and accurate accelerometer and signal acquisition hardware and stringent time synchronization of all sensors data are just examples of the requirements imposed by most of these applications. This paper presents a prototype system for health monitoring of civil engineering structures that has been jointly conceived by a team of civil, and electrical and computer engineers. It merges the benefits of standard and off-the-shelf (COTS) hardware and communication technologies with a minimum set of custom-designed signal acquisition hardware that is mandatory to fulfill all application requirements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the modeling efforts on antenna design and frequency selection to monitor brain temperature during prolonged surgery using noninvasive microwave radiometry. A tapered log-spiral antenna design is chosen for its wideband characteristics that allow higher power collection from deep brain. Parametric analysis with the software HFSS is used to optimize antenna performance for deep brain temperature sensing. Radiometric antenna efficiency (eta) is evaluated in terms of the ratio of power collected from brain to total power received by the antenna. Anatomical information extracted from several adult computed tomography scans is used to establish design parameters for constructing an accurate layered 3-D tissue phantom. This head phantom includes separate brain and scalp regions, with tissue equivalent liquids circulating at independent temperatures on either side of an intact skull. The optimized frequency band is 1.1-1.6 GHz producing an average antenna efficiency of 50.3% from a two turn log-spiral antenna. The entire sensor package is contained in a lightweight and low-profile 2.8 cm diameter by 1.5 cm high assembly that can be held in place over the skin with an electromagnetic interference shielding adhesive patch. The calculated radiometric equivalent brain temperature tracks within 0.4 degrees C of the measured brain phantom temperature when the brain phantom is lowered 10. C and then returned to the original temperature (37 degrees C) over a 4.6-h experiment. The numerical and experimental results demonstrate that the optimized 2.5-cm log-spiral antenna is well suited for the noninvasive radiometric sensing of deep brain temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfilment of the requirements for the Degree of Master of Science in Geospatial Technologies

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE To evaluate clinical evidence on the safety and efficacy of fenproporex for treating obesity. METHODS MEDLINE, LILACS and Cochrane Controlled Trials Register were searched as well as references cited by articles and relevant documents. Two authors independently assessed the studies for inclusion and regarding risk of bias, collected data, and accuracy. Eligible studies were all those placebo-controlled that provided data on the efficacy and safety of Fenproporex to treat obesity. RESULTS Only four controlled studies met the inclusion criteria. One randomized, placebo-controlled trial on Fenproporex was found on electronic databases. Three placebo-controlled studies (in non-indexed journals) were identified by hand-searching. Patients with cardiovascular and other comorbidities were excluded in all studies. Trials lasted from 40 to 364 days and doses ranged from 20 to 33.6 mg/d. All controlled studies found that weight loss among Fenproporex-treated patients was greater than that produced by the placebo, but drug effect was modest. Fenproporex produced additional weight reductions of 4.7 kg (one year), 3.8 kg (six months) and 1.55 kg (two months) in average, in relation to diet and exercise only (three trials). Insomnia, irritability, and anxiety were the most frequently reported side effects in the four studies. CONCLUSIONS There is a paucity of randomized, placebo-controlled trials on Fenproporex and those identified here present major methodological flaws. These studies suggest that Fenproporex is modestly effective in promoting weight loss. Nonetheless, they failed to provide evidence that it reduces obesity-associated morbidity and mortality. Data from these studies are insufficient to determine the risk-benefit profile of Fenproporex. Abuse potential and amphetamine-like adverse effects are causes for concern.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfilment of the requirements for the Degree of Master of Science in Geospatial Technologies

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to contribute to the assessment of exposure levels of ultrafine particles (UFP) in the urban environment of Lisbon, Portugal, due to automobile traffic, by monitoring lung-deposited alveolar surface area (resulting from exposure to UFP) in a major avenue leading to the town centre during late Spring, as well as in indoor buildings facing it. This study revealed differentiated patterns for week days and weekends, consistent with PM2.5 and PM10 patterns currently monitored by air quality stations in Lisbon. The observed ultrafine particulate levels could be directly related with the fluxes of automobile traffic. During a typical week, UFP alveolar deposited surface area varied between 35.0 and 89.2 mu m(2)/cm(3), which is comparable with levels reported for other towns such in Germany and United States. The measured values allowed the determination of the number of UFP per cm(3), which are comparable to levels reported for Madrid and Brisbane. In what concerns outdoor/indoor levels, we observed higher levels (32-63%) outdoor, which is somewhat lower than levels observed in houses in Ontario.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Brown adipose tissue (BAT) plays an important role in whole body metabolism and could potentially mediate weight gain and insulin sensitivity. Although some imaging techniques allow BAT detection, there are currently no viable methods for continuous acquisition of BAT energy expenditure. We present a non-invasive technique for long term monitoring of BAT metabolism using microwave radiometry. Methods: A multilayer 3D computational model was created in HFSS™ with 1.5 mm skin, 3-10 mm subcutaneous fat, 200 mm muscle and a BAT region (2-6 cm3) located between fat and muscle. Based on this model, a log-spiral antenna was designed and optimized to maximize reception of thermal emissions from the target (BAT). The power absorption patterns calculated in HFSS™ were combined with simulated thermal distributions computed in COMSOL® to predict radiometric signal measured from an ultra-low-noise microwave radiometer. The power received by the antenna was characterized as a function of different levels of BAT metabolism under cold and noradrenergic stimulation. Results: The optimized frequency band was 1.5-2.2 GHz, with averaged antenna efficiency of 19%. The simulated power received by the radiometric antenna increased 2-9 mdBm (noradrenergic stimulus) and 4-15 mdBm (cold stimulus) corresponding to increased 15-fold BAT metabolism. Conclusions: Results demonstrated the ability to detect thermal radiation from small volumes (2-6 cm3) of BAT located up to 12 mm deep and to monitor small changes (0.5°C) in BAT metabolism. As such, the developed miniature radiometric antenna sensor appears suitable for non-invasive long term monitoring of BAT metabolism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfilment of the requirements for the Degree of Master of Science in Geospatial Technologies

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho descreve a abordagem abrangente sobre a melhoria do sistema de gestão da qualidade na Unidade de Imagiologia do Hospital da Boavista através da implementação das normas de acreditação da Joint Commission International (JCI). Fundamental para a melhoria geral da qualidade é a redução contínua de riscos para os doentes e para os profissionais da Unidade. Tais riscos podem existir ao nível do ambiente físico assim como no circuito dos exames e dos doentes. A acreditação em Saúde é uma das prioridades estratégicas do Ministério da Saúde e tem como objetivo fortalecer a confiança dos cidadãos nos profissionais de saúde bem como nas instituições de saúde. É importante que Portugal cultive a melhoria da qualidade e segurança nas instituições de saúde mantendo uma relação adequada custo/benefício. A União Europeia tem feito um esforço para que a acreditação seja harmoniosa nos seus princípios, no entanto é respeitada sempre a prevalência da legislação de cada país, bem como as suas especificações culturais e religiosas (Shaw, 2006), responsabilizando-o pelo seu sistema de saúde O trabalho aqui apresentado tem como objetivo principal fundamentar a escolha do modelo de acreditação da JCI para o Hospital da Boavista, nomeadamente para a Unidade de Imagiologia, ver se os padrões estão de acordo com os procedimentos da Unidade, identificar falhas e apontar possiveis melhorias. Pretende-se ainda mostrar a importância da implementação dos sistemas de certificação e acreditação da gestão da qualidade, documentada pela experiência profissional, bem como o know-how do Hospital da Boavista, assim como a complementaridade dos programas da gestão da qualidade, certificação e acreditação. A escolha do modelo de acreditação da JCI, foi uma opção do Hospital da Boavista baseada na credibilidade e no grau de exigência que a entidade impõe. Foi imperativo que a Unidade de Imagiologia realizasse as suas funções de forma válida e fiável e que disponibilizasse produtos / serviços de qualidade. A monitorização e consequente controlo de qualidade do serviço prestado pela Unidade de Imagiologia, foi difícil mas simplificado, em parte, devido ao sistema de gestão da qualidade ISO 9001:2008 já implementado, tendo este sido consolidado com a implementação da acreditação da JCI, com padrões específicos bem definidos na gestão do controlo de qualidade na Unidade de Imagiologia do Hospital da Boavista.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among the most important measures to prevent wild forest fires is the use of prescribed and controlled burning actions in order to reduce the availability of fuel mass. However, the impact of these activities on soil physical and chemical properties varies according to the type of both soil and vegetation and is not fully understood. Therefore, soil monitoring campaigns are often used to measure these impacts. In this paper we have successfully used three statistical data treatments - the Kolmogorov-Smirnov test followed by the ANOVA and the Kruskall-Wallis tests – to investigate the variability among the soil pH, soil moisture, soil organic matter and soil iron variables for different monitoring times and sampling procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mathematical models and statistical analysis are key instruments in soil science scientific research as they can describe and/or predict the current state of a soil system. These tools allow us to explore the behavior of soil related processes and properties as well as to generate new hypotheses for future experimentation. A good model and analysis of soil properties variations, that permit us to extract suitable conclusions and estimating spatially correlated variables at unsampled locations, is clearly dependent on the amount and quality of data and of the robustness techniques and estimators. On the other hand, the quality of data is obviously dependent from a competent data collection procedure and from a capable laboratory analytical work. Following the standard soil sampling protocols available, soil samples should be collected according to key points such as a convenient spatial scale, landscape homogeneity (or non-homogeneity), land color, soil texture, land slope, land solar exposition. Obtaining good quality data from forest soils is predictably expensive as it is labor intensive and demands many manpower and equipment both in field work and in laboratory analysis. Also, the sampling collection scheme that should be used on a data collection procedure in forest field is not simple to design as the sampling strategies chosen are strongly dependent on soil taxonomy. In fact, a sampling grid will not be able to be followed if rocks at the predicted collecting depth are found, or no soil at all is found, or large trees bar the soil collection. Considering this, a proficient design of a soil data sampling campaign in forest field is not always a simple process and sometimes represents a truly huge challenge. In this work, we present some difficulties that have occurred during two experiments on forest soil that were conducted in order to study the spatial variation of some soil physical-chemical properties. Two different sampling protocols were considered for monitoring two types of forest soils located in NW Portugal: umbric regosol and lithosol. Two different equipments for sampling collection were also used: a manual auger and a shovel. Both scenarios were analyzed and the results achieved have allowed us to consider that monitoring forest soil in order to do some mathematical and statistical investigations needs a sampling procedure to data collection compatible to established protocols but a pre-defined grid assumption often fail when the variability of the soil property is not uniform in space. In this case, sampling grid should be conveniently adapted from one part of the landscape to another and this fact should be taken into consideration of a mathematical procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Gestão e Avaliação de Tecnologias em Saúde