940 resultados para reproducibility of calculated surfaces
Resumo:
OBJECTIVE: The aim of the study was to validate a French adaptation of the 5th version of the Addiction Severity Index (ASI) instrument in a Swiss sample of illicit drug users. PARTICIPANTS AND SETTING: The participants in the study were 54 French-speaking dependent patients, most of them with opiates as the drug of first choice. Procedure: Analyses of internal consistency (convergent and discriminant validity) and reliability, including measures of test-retest and inter-observer correlations, were conducted. RESULTS: Besides good applicability of the test, the results on composite scores (CSs) indicate comparable results to those obtained in a sample of American opiate-dependent patients. Across the seven dimensions of the ASI, Cronbach's alpha ranged from 0.42 to 0.76, test-retest correlations coefficients ranged from 0.48 to 0.98, while for CSs, inter-observer correlations ranged from 0.76 to 0.99. CONCLUSIONS: Despite several limitations, the French version of the ASI presents acceptable criteria of applicability, validity and reliability in a sample of drug-dependent patients.
Resumo:
The aim of the study was to determine objective radiological signs of danger to life in survivors of manual strangulation and to establish a radiological scoring system for the differentiation between life-threatening and non-life-threatening strangulation by dividing the cross section of the neck into three zones (superficial, middle and deep zone). Forensic pathologists classified 56 survivors of strangulation into life-threatening and non-life-threatening cases by history and clinical examination alone, and two blinded radiologists evaluated the MRIs of the neck. In 15 cases, strangulation was life-threatening (27%), compared with 41 cases in which strangulation was non-life-threatening (73%). The best radiological signs on MRI to differentiate between the two groups were intramuscular haemorrhage/oedema, swelling of platysma and intracutaneous bleeding (all p = 0.02) followed by subcutaneous bleeding (p = 0.034) and haemorrhagic lymph nodes (p = 0.04), all indicating life-threatening strangulation. The radiological scoring system showed a sensitivity and specificity of approximately 70% for life-threatening strangulation, when at least two neck zones were affected. MRI is not only helpful in assessing the severity of strangulation, but is also an excellent documentation tool that is even admissible in court.
Resumo:
Recently, the spin-echo full-intensity acquired localized (SPECIAL) spectroscopy technique was proposed to unite the advantages of short TEs on the order of milliseconds (ms) with full sensitivity and applied to in vivo rat brain. In the present study, SPECIAL was adapted and optimized for use on a clinical platform at 3T and 7T by combining interleaved water suppression (WS) and outer volume saturation (OVS), optimized sequence timing, and improved shimming using FASTMAP. High-quality single voxel spectra of human brain were acquired at TEs below or equal to 6 ms on a clinical 3T and 7T system for six volunteers. Narrow linewidths (6.6 +/- 0.6 Hz at 3T and 12.1 +/- 1.0 Hz at 7T for water) and the high signal-to-noise ratio (SNR) of the artifact-free spectra enabled the quantification of a neurochemical profile consisting of 18 metabolites with Cramér-Rao lower bounds (CRLBs) below 20% at both field strengths. The enhanced sensitivity and increased spectral resolution at 7T compared to 3T allowed a two-fold reduction in scan time, an increased precision of quantification for 12 metabolites, and the additional quantification of lactate with CRLB below 20%. Improved sensitivity at 7T was also demonstrated by a 1.7-fold increase in average SNR (= peak height/root mean square [RMS]-of-noise) per unit-time.
Resumo:
QUESTIONS UNDER STUDY AND PRINCIPLES: Estimating glomerular filtration rate (GFR) in hospitalised patients with chronic kidney disease (CKD) is important for drug prescription but it remains a difficult task. The purpose of this study was to investigate the reliability of selected algorithms based on serum creatinine, cystatin C and beta-trace protein to estimate GFR and the potential added advantage of measuring muscle mass by bioimpedance. In a prospective unselected group of patients hospitalised in a general internal medicine ward with CKD, GFR was evaluated using inulin clearance as the gold standard and the algorithms of Cockcroft, MDRD, Larsson (cystatin C), White (beta-trace) and MacDonald (creatinine and muscle mass by bioimpedance). 69 patients were included in the study. Median age (interquartile range) was 80 years (73-83); weight 74.7 kg (67.0-85.6), appendicular lean mass 19.1 kg (14.9-22.3), serum creatinine 126 μmol/l (100-149), cystatin C 1.45 mg/l (1.19-1.90), beta-trace protein 1.17 mg/l (0.99-1.53) and GFR measured by inulin 30.9 ml/min (22.0-43.3). The errors in the estimation of GFR and the area under the ROC curves (95% confidence interval) relative to inulin were respectively: Cockcroft 14.3 ml/min (5.55-23.2) and 0.68 (0.55-0.81), MDRD 16.3 ml/min (6.4-27.5) and 0.76 (0.64-0.87), Larsson 12.8 ml/min (4.50-25.3) and 0.82 (0.72-0.92), White 17.6 ml/min (11.5-31.5) and 0.75 (0.63-0.87), MacDonald 32.2 ml/min (13.9-45.4) and 0.65 (0.52-0.78). Currently used algorithms overestimate GFR in hospitalised patients with CKD. As a consequence eGFR targeted prescriptions of renal-cleared drugs, might expose patients to overdosing. The best results were obtained with the Larsson algorithm. The determination of muscle mass by bioimpedance did not provide significant contributions.
Resumo:
The basal sliding surfaces in large rockslides are often composed of several surfaces and possess a complex geometry. The exact morphology and location in three dimensions of the sliding surface remains generally unknown, in spite of extensive field and subsurface investigations, such as those at the Åknes rockslide (western Norway). This knowledge is crucial for volume estimations, failure mechanisms, and numerical slope stability modeling. This paper focuses on the geomorphologic characterization of the basal sliding surface of a postglacial rockslide scar in the vicinity of Åknes. This scar displays a stepped basal sliding surface formed by dip slopes of the gneiss foliation linked together by steeply dipping fractures. A detailed characterization of the rockslide scar by means of high-resolution digital elevation models permits statistical parameters of dip angle, spacing, persistence, and roughness of foliation surfaces and step fractures to be obtained. The characteristics are used for stochastic simulations of stepped basal sliding surfaces at the Åknes rockslide. These findings are compared with previous models based on geophysical investigations. This study discusses the investigation of rockslide scars and rock outcrops for a better understanding of potential rockslides. This work identifies possible basal sliding surface locations, which is a valuable input for volume estimates, design and location of monitoring instrumentation, and numerical slope stability modeling.
Resumo:
Near infrared spectroscopy (NIRS) is a non-invasive method of estimating the haemoglobin concentration changes in certain tissues. It is frequently used to monitor oxygenation of the brain in neonates. At present it is not clear whether near infrared spectroscopy of other organs (e.g. the liver as a corresponding site in the splanchnic region, which reacts very sensitively to haemodynamic instability) provides reliable values on their tissue oxygenation. The aim of the study was to test near infrared spectroscopy by measuring known physiologic changes in tissue oxygenation of the liver in newborn infants during and after feeding via a naso-gastric tube. The test-retest variability of such measurements was also determined. On 28 occasions in 25 infants we measured the tissue oxygenation index (TOI) of the liver and the brain continuously before, during and 30 minutes after feeding via a gastric tube. Simultaneously we measured arterial oxygen saturation (SaO2), heart rate (HR) and mean arterial blood pressure (MAP). In 10 other newborn infants we performed a test-retest analysis of the liver tissue oxygenation index to estimate the variability in repeated intra-individual measurements. The tissue oxygenation index of the liver increased significantly from 56.7 +/- 7.5% before to 60.3 +/- 5.6% after feeding (p < 0.005), and remained unchanged for the next 30 minutes. The tissue oxygenation index of the brain (62.1 +/- 9.7%), SaO2 (94.4 +/- 7.1%), heart rate (145 +/- 17.3 min-1) and mean arterial blood pressure (52.8 +/- 10.2 mm Hg) did not change significantly. The test-retest variability for intra-individual measurements was 2.7 +/- 2.1%. After bolus feeding the tissue oxygenation index of the liver increased as expected. This indicates that near infrared spectroscopy is suitable for monitoring changes in tissue oxygenation of the liver in newborn infants.
Resumo:
Hepatitis E virus (HEV) is responsible for many enterically transmitted viral hepatitides around the world. It is currently one of the waterborne diseases of global concern. In industrialized countries, HEV appears to be more common than previously thought, even if it is rarely virulent. In Switzerland, seroprevalence studies revealed that HEV is endemic, but no information was available on its environmental spread. The aim of this study was to investigate -using qPCR- the occurrence and concentration of HEV and three other viruses (norovirus genogroup II, human adenovirus-40 and porcine adenovirus) in influents and effluents of 31 wastewater treatment plants (WWTPs) in Switzerland. Low concentrations of HEV were detected in 40 out of 124 WWTP influent samples, showing that HEV is commonly present in this region. The frequency of HEV occurrence was higher in summer than in winter. No HEV was detected in WWTP effluent samples, which indicates a low risk of environmental contamination. HEV occurrence and concentrations were lower than those of norovirus and adenovirus. The autochthonous HEV genotype 3 was found in all positive samples, but a strain of the non-endemic and highly pathogenic HEV genotype I was isolated in one sample, highlighting the possibility of environmental circulation of this genotype. A porcine fecal marker (porcine adenovirus) was not detected in HEV positive samples, indicating that swine are not the direct source of HEV present in wastewater. Further investigations will be necessary to determine the reservoirs and the routes of dissemination of HEV.
Resumo:
RATIONALE AND OBJECTIVES: To determine optimum spatial resolution when imaging peripheral arteries with magnetic resonance angiography (MRA). MATERIALS AND METHODS: Eight vessel diameters ranging from 1.0 to 8.0 mm were simulated in a vascular phantom. A total of 40 three-dimensional flash MRA sequences were acquired with incremental variations of fields of view, matrix size, and slice thickness. The accurately known eight diameters were combined pairwise to generate 22 "exact" degrees of stenosis ranging from 42% to 87%. Then, the diameters were measured in the MRA images by three independent observers and with quantitative angiography (QA) software and used to compute the degrees of stenosis corresponding to the 22 "exact" ones. The accuracy and reproducibility of vessel diameter measurements and stenosis calculations were assessed for vessel size ranging from 6 to 8 mm (iliac artery), 4 to 5 mm (femoro-popliteal arteries), and 1 to 3 mm (infrapopliteal arteries). Maximum pixel dimension and slice thickness to obtain a mean error in stenosis evaluation of less than 10% were determined by linear regression analysis. RESULTS: Mean errors on stenosis quantification were 8.8% +/- 6.3% for 6- to 8-mm vessels, 15.5% +/- 8.2% for 4- to 5-mm vessels, and 18.9% +/- 7.5% for 1- to 3-mm vessels. Mean errors on stenosis calculation were 12.3% +/- 8.2% for observers and 11.4% +/- 15.1% for QA software (P = .0342). To evaluate stenosis with a mean error of less than 10%, maximum pixel surface, the pixel size in the phase direction, and the slice thickness should be less than 1.56 mm2, 1.34 mm, 1.70 mm, respectively (voxel size 2.65 mm3) for 6- to 8-mm vessels; 1.31 mm2, 1.10 mm, 1.34 mm (voxel size 1.76 mm3), for 4- to 5-mm vessels; and 1.17 mm2, 0.90 mm, 0.9 mm (voxel size 1.05 mm3) for 1- to 3-mm vessels. CONCLUSION: Higher spatial resolution than currently used should be selected for imaging peripheral vessels.
Resumo:
The development of targeted treatment strategies adapted to individual patients requires identification of the different tumor classes according to their biology and prognosis. We focus here on the molecular aspects underlying these differences, in terms of sets of genes that control pathogenesis of the different subtypes of astrocytic glioma. By performing cDNA-array analysis of 53 patient biopsies, comprising low-grade astrocytoma, secondary glioblastoma (respective recurrent high-grade tumors), and newly diagnosed primary glioblastoma, we demonstrate that human gliomas can be differentiated according to their gene expression. We found that low-grade astrocytoma have the most specific and similar expression profiles, whereas primary glioblastoma exhibit much larger variation between tumors. Secondary glioblastoma display features of both other groups. We identified several sets of genes with relatively highly correlated expression within groups that: (a). can be associated with specific biological functions; and (b). effectively differentiate tumor class. One prominent gene cluster discriminating primary versus nonprimary glioblastoma comprises mostly genes involved in angiogenesis, including VEGF fms-related tyrosine kinase 1 but also IGFBP2, that has not yet been directly linked to angiogenesis. In situ hybridization demonstrating coexpression of IGFBP2 and VEGF in pseudopalisading cells surrounding tumor necrosis provided further evidence for a possible involvement of IGFBP2 in angiogenesis. The separating groups of genes were found by the unsupervised coupled two-way clustering method, and their classification power was validated by a supervised construction of a nearly perfect glioma classifier.
Resumo:
OBJECTIVE: The optimal coronary MR angiography sequence has yet to be determined. We sought to quantitatively and qualitatively compare four coronary MR angiography sequences. SUBJECTS AND METHODS. Free-breathing coronary MR angiography was performed in 12 patients using four imaging sequences (turbo field-echo, fast spin-echo, balanced fast field-echo, and spiral turbo field-echo). Quantitative comparisons, including signal-to-noise ratio, contrast-to-noise ratio, vessel diameter, and vessel sharpness, were performed using a semiautomated analysis tool. Accuracy for detection of hemodynamically significant disease (> 50%) was assessed in comparison with radiographic coronary angiography. RESULTS: Signal-to-noise and contrast-to-noise ratios were markedly increased using the spiral (25.7 +/- 5.7 and 15.2 +/- 3.9) and balanced fast field-echo (23.5 +/- 11.7 and 14.4 +/- 8.1) sequences compared with the turbo field-echo (12.5 +/- 2.7 and 8.3 +/- 2.6) sequence (p < 0.05). Vessel diameter was smaller with the spiral sequence (2.6 +/- 0.5 mm) than with the other techniques (turbo field-echo, 3.0 +/- 0.5 mm, p = 0.6; balanced fast field-echo, 3.1 +/- 0.5 mm, p < 0.01; fast spin-echo, 3.1 +/- 0.5 mm, p < 0.01). Vessel sharpness was highest with the balanced fast field-echo sequence (61.6% +/- 8.5% compared with turbo field-echo, 44.0% +/- 6.6%; spiral, 44.7% +/- 6.5%; fast spin-echo, 18.4% +/- 6.7%; p < 0.001). The overall accuracies of the sequences were similar (range, 74% for turbo field-echo, 79% for spiral). Scanning time for the fast spin-echo sequences was longest (10.5 +/- 0.6 min), and for the spiral acquisitions was shortest (5.2 +/- 0.3 min). CONCLUSION: Advantages in signal-to-noise and contrast-to-noise ratios, vessel sharpness, and the qualitative results appear to favor spiral and balanced fast field-echo coronary MR angiography sequences, although subjective accuracy for the detection of coronary artery disease was similar to that of other sequences.
Resumo:
OBJECTIVE: To determine the psychometric properties of an adapted version of the Falls Efficacy Scale (FES) in older rehabilitation patients. DESIGN: Cross-sectional survey. SETTING: Postacute rehabilitation facility in Switzerland. PARTICIPANTS: Seventy elderly persons aged 65 years and older receiving postacute, inpatient rehabilitation. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: FES questions asked about subject's confidence (range, 0 [none]-10 [full]) in performing 12 activities of daily living (ADLs) without falling. Construct validity was assessed using correlation with measures of physical (basic ADLs [BADLs]), cognitive (Mini-Mental State Examination [MMSE]), affective (15-item Geriatric Depression Scale [GDS]), and mobility (Performance Oriented Mobility Assessment [POMA]) performance. Predictive validity was assessed using the length of rehabilitation stay as the outcome. To determine test-retest reliability, FES administration was repeated in a random subsample (n=20) within 72 hours. RESULTS: FES scores ranged from 10 to 120 (mean, 88.7+/-26.5). Internal consistency was optimal (Cronbach alpha=.90), and item-to-total correlations were all significant, ranging from .56 (toilet use) to .82 (reaching into closets). Test-retest reliability was high (intraclass correlation coefficient, .97; 95% confidence interval, .95-.99; P<.001). Subjects reporting a fall in the previous year had lower FES scores than nonfallers (85.0+/-25.2 vs 94.4+/-27.9, P=.054). The FES correlated with POMA (Spearman rho=.40, P<.001), MMSE (rho=.37, P=.001), BADL (rho=.43, P<.001), and GDS (rho=-.53, P<.001) scores. These relationships remained significant in multivariable analysis for BADLs and GDS, confirming FES construct validity. There was a significant inverse relationship between FES score and the length of rehabilitation stay, independent of sociodemographic, functional, cognitive, and fall status. CONCLUSIONS: This adapted FES is reliable and valid in older patients undergoing postacute rehabilitation. The independent association between poor falls efficacy and increased length of stay has not been previously described and needs further investigations.
Resumo:
The study was set up to evaluate the impact of two commercial larvicide formulations, Bacillus thuringiensis serovar israelensis base (Bti) at 15 ppm/1 min and temephos at 0.03 ppm of active ingredient, used to control Simulium pertinax populations, on associated non-target entomofauna occupying the same breeding sites. The experiments were carried out on the Pedra Branca and Muricana rivers, on the slopes of Serra do Mar massif, municipality of Paraty, state of Rio de Janeiro, Brazil. Bti was applied to the river Pedra Branca and temephosto theriver Muricana. On both rivers, treatment and control sections were labeled as such, each one with two observation posts: slow moving water and fast water regions respectively. Artificial substrata was used to evaluate the abundance of associated entomofauna. Attached immature stages of arthropods were removed from both of its surfaces fortnightly. Were collected, from the two rivers, 28 477 specimens of the entomofauna associated with S. pertinax. The families Hydropsychidae, Chironomidae, Bactidae, Simuliidae, Blephariceridae and Megapodagrionidae were represented. These was an impact of temephos on the entomofauna associated with S. pertinax only in Simuliidae and Chironomidae, and to Bti only in Simuliidae. However, the reduction in their numbers was not statistically significant.
Resumo:
Cognitive impairment has been identified in the early phase of schizophrenia spectrum disorders, and is a major contributor to disease-related disability. While screening tools assessing cognitive impairment have been validated for adult schizophrenic populations, there is a need for brief, easily administered, standardized instruments that provide clinically relevant information for adolescents. This study examines the utility of the Repeatable Battery for the Assessment of Neuropsychological Status (RBANS) in identifying and quantifying neurocognitive impairment in adolescents with schizophrenia spectrum disorders and other serious psychiatric illnesses. 112 adolescents, including 32 healthy subjects and 80 patients, were administered the RBANS. Patients with psychotic disorders demonstrated significant impairment on the RBANS total score compared to patients with other disorders and healthy controls, but this impairment appeared somewhat less severe than is typically reported for in adult patients with schizophrenia on this measure. The RBANS appears to be sensitive in the detection of neurocognitive impairment in a psychiatric population of adolescents with psychotic symptomatology, and may therefore have utility as a clinical screening instrument and/or neurocognitive outcome measure in this population.
Resumo:
BACKGROUND: Self-administered, general health risk screening questionnaires that are administered while patients wait in the doctor's office may be a reasonable and timesaving approach to address the requirements of preventive medicine in a typical 10-min medical visit. The psychometric characteristics of the Alcohol Use Disorders Identification Test (AUDIT) incorporated within a health questionnaire (H-AUDIT) have not been examined. METHODS: The reliability and validity of the self-administered AUDIT were compared between the H-AUDIT and the AUDIT used as a single scale (S-AUDIT) in 332 primary care patients. RESULTS: No major demographic or alcohol use characteristics were found between the 166 subjects who completed the H-AUDIT and the 166 individuals who completed the S-AUDIT. The test-retest reliability of the 166 subjects who completed the H-AUDIT [estimated by Spearman correlation coefficient at a 6-week interval (0.88), internal consistency (total correlation coefficients for all items ranged from 0.38 to 0.69; Cronbach alpha index 0.85), and the sensitivity and specificity of the H-AUDIT were used to identify at-risk drinkers' areas under receiver operating characteristic (0.77) and alcohol-dependent subjects' areas under receiver operating characteristic (0.89)] was similar to the same measurements obtained with the 166 individuals who completed the S-AUDIT. CONCLUSIONS: The AUDIT incorporated in a health risk screening questionnaire is a reliable and valid self-administered instrument to identify at-risk drinkers and alcohol-dependent individuals in primary care settings.
Resumo:
Since GHB (gamma-hydroxybutyric acid) is naturally produced in the human body, clinical and forensic toxicologists must be able to discriminate between endogenous levels and a concentration resulting from exposure. To suggest an alternative to the use of interpretative concentration cut-offs, the detection of exogenous GHB in urine specimens was investigated by means of gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). GHB was isolated from urinary matrix by successive purification on Oasis MCX and Bond Elute SAX solid-phase extraction (SPE) cartridges prior to high-performance liquid chromatography (HPLC) fractioning using an Atlantis dC18 column eluted with a mixture of formic acid and methanol. Subsequent intramolecular esterification of GHB leading to the formation of gamma-butyrolactone (GBL) was carried out to avoid introduction of additional carbon atoms for carbon isotopic ratio analysis. A precision of 0.3 per thousand was determined using this IRMS method for samples at GHB concentrations of 10 mg/L. The (13)C/(12)C ratios of GHB in samples of subjects exposed to the drug ranged from -32.1 to -42.1 per thousand, whereas the results obtained for samples containing GHB of endogenous origin at concentration levels less than 10 mg/L were in the range -23.5 to -27.0 per thousand. Therefore, these preliminary results show that a possible discrimination between endogenous and exogenous GHB can be made using carbon isotopic ratio analyses.