976 resultados para relaxation to fixed points
Resumo:
Autonomous system applications are typically limited by the power supply operational lifetime when battery replacement is difficult or costly. A trade-off between battery size and battery life is usually calculated to determine the device capability and lifespan. As a result, energy harvesting research has gained importance as society searches for alternative energy sources for power generation. For instance, energy harvesting has been a proven alternative for powering solar-based calculators and self-winding wristwatches. Thus, the use of energy harvesting technology can make it possible to assist or replace batteries for portable, wearable, or surgically-implantable autonomous systems. Applications such as cardiac pacemakers or electrical stimulation applications can benefit from this approach since the number of surgeries for battery replacement can be reduced or eliminated. Research on energy scavenging from body motion has been investigated to evaluate the feasibility of powering wearable or implantable systems. Energy from walking has been previously extracted using generators placed on shoes, backpacks, and knee braces while producing power levels ranging from milliwatts to watts. The research presented in this paper examines the available power from walking and running at several body locations. The ankle, knee, hip, chest, wrist, elbow, upper arm, side of the head, and back of the head were the chosen target localizations. Joints were preferred since they experience the most drastic acceleration changes. For this, a motor-driven treadmill test was performed on 11 healthy individuals at several walking (1-4 mph) and running (2-5 mph) speeds. The treadmill test provided the acceleration magnitudes from the listed body locations. Power can be estimated from the treadmill evaluation since it is proportional to the acceleration and frequency of occurrence. Available power output from walking was determined to be greater than 1mW/cm³ for most body locations while being over 10mW/cm³ at the foot and ankle locations. Available power from running was found to be almost 10 times higher than that from walking. Most energy harvester topologies use linear generator approaches that are well suited to fixed-frequency vibrations with sub-millimeter amplitude oscillations. In contrast, body motion is characterized with a wide frequency spectrum and larger amplitudes. A generator prototype based on self-winding wristwatches is deemed to be appropriate for harvesting body motion since it is not limited to operate at fixed-frequencies or restricted displacements. Electromagnetic generation is typically favored because of its slightly higher power output per unit volume. Then, a nonharmonic oscillating rotational energy scavenger prototype is proposed to harness body motion. The electromagnetic generator follows the approach from small wind turbine designs that overcome the lack of a gearbox by using a larger number of coil and magnets arrangements. The device presented here is composed of a rotor with multiple-pole permanent magnets having an eccentric weight and a stator composed of stacked planar coils. The rotor oscillations induce a voltage on the planar coil due to the eccentric mass unbalance produced by body motion. A meso-scale prototype device was then built and evaluated for energy generation. The meso-scale casing and rotor were constructed on PMMA with the help of a CNC mill machine. Commercially available discrete magnets were encased in a 25mm rotor. Commercial copper-coated polyimide film was employed to manufacture the planar coils using MEMS fabrication processes. Jewel bearings were used to finalize the arrangement. The prototypes were also tested at the listed body locations. A meso-scale generator with a 2-layer coil was capable to extract up to 234 µW of power at the ankle while walking at 3mph with a 2cm³ prototype for a power density of 117 µW/cm³. This dissertation presents the analysis of available power from walking and running at different speeds and the development of an unobtrusive miniature energy harvesting generator for body motion. Power generation indicates the possibility of powering devices by extracting energy from body motion.
Resumo:
Objective: Whether or not a protective stoma reduces the rate of anastomotic leakage after distal colorectal anastomosis is still discussed controversially. It does however facilitate clinical management once leakage has occurred. Loop ileostomies seem to be associated with a lower morbidity and a better quality of life compared to loop colostomies. Generally, diverting loop ileostomies are secured at skin level by means of a supporting device in order to prevent retraction of the ileostomy into the abdomen. However, due to the supporting rod, difficulties may occur in applying a stoma bag correctly and leakage of faeces onto the skin may occur even with correct eversion of the afferent limb. Our aim was to compare morbidity and time to self-sufficient stoma-care in patients having a loop ileostomy with rod to those without rod. Methods: A total of 60 patients necessitating loop ileostomy were analyzed. Patients received surgery in of the two involved institutions according to inhouse standard procedures. 30 patients had an ileostomy with rod (VCHK Inselspital) and a further 30 without rod (KSW Winterthur). Morbidity and time to self-sufficiency regarding stoma care was analyzed during the first 90 postoperative days. Morbidity was determined according to a scoring system ranging from 0 to 4 points for any given set of possible complications (bleeding, necrosis, skin irritation, abscess, stenosis, retraction, fistula, prolapse, parastomal hernia, incomplete diversion), where 0 = no complication and 4 = severe complication. Continuous variables were expressed as median (95% Confidence Interval). For comparisons between the groups the Mann-Whitney U test was used, between categorical variables the X2 test was applied. Results: There were no significant differences in length of hospital stay or time to self-sufficient stoma-care between the groups. Although not significant, patients with a rod ileostomy had a tendency towards more stoma-related complications as well as stoma-related reoperations. The number of patients reaching total self-sufficiency regarding stoma care was higher after rodless ileostomy. Conclusion: According to our data, rodless ileostomies seemto fare just as well as those with a supporting rod, with equal morbidity rates and more patients reaching self-sufficient stoma care. Therefore routine application of a rod for diverting loop ileostomy seems unnecessary
Resumo:
This investigation assessed the applicability of Dr. William Haddon’s strategies for controlling hazards involving materials-handling operations in industrial and mining workplaces. Published over 20 years ago, Haddon’s strategies purport to include all strategies for preventing and mitigating harm to people, property, and the environment. Students in an undergraduate class were assigned to find tactical examples of each of Haddon’s strategies applicable to material handling. Haddon’s tenth strategy involving medical care and rehabilitation was not included. Their classifications were analyzed to identify points of confusion as well as points of general agreement. Students found numerous tactics for strategies involving engineering and behavioral strategies. Fewer tactics were identified for strategies involving damage control through effective and timely response.
Resumo:
Intraosseous ganglia of the distal tibia are rare. We evaluated the feasibility of surgically treating these lesions with an arthroscopically assisted technique. Five patients with symptomatic distal tibial ganglia underwent surgical curettage and excision with this technique. All patients underwent débridement of the chondral lesion and hypertrophied synovial lining when present, probing of the portal to the ganglion, and subsequently thorough curettage with bone grafting performed through a cortical window made from a separate small incision. Biopsy confirmed the diagnosis in all patients. All patients had eventual relief of symptoms with good integration of bone graft at final followup. There were no recurrences at a minimum followup of 19 months (mean, 38.6 months; range, 19-69 months). Mean time for return to full function was 15.4 weeks (range, 8-17 weeks). There were no intraoperative or postoperative complications. The mean American Orthopaedic Foot and Ankle Society scores increased from 73 points (range, 67-77 points) preoperatively to 94 points (range, 90-100 points) postoperatively. Arthroscopically assisted surgical treatment of ganglia of the distal tibia in the appropriate patient is a reasonably simple technique that relieves symptoms and helps the patient to regain normal gait and full function with no recurrence (in our small series). LEVEL OF EVIDENCE: Level IV, case series. See Guidelines for Authors for a complete description of levels of evidence.
Resumo:
INTRODUCTION The objective of this trial was to compare the survival rates of mandibular lingual retainers bonded with either chemically cured or light-cured adhesive after orthodontic treatment. METHODS Patients having undergone orthodontic treatment at a private orthodontic office were randomly allocated to fixed retainers placed with chemically cured composite or light-cured composite. Eligibility criteria included no active caries, restorations, or fractures on the mandibular anterior teeth, and adequate oral hygiene. The main outcome was any type of first-time lingual retainer breakage; pattern of failure (adapted adhesive remnant index scores) was a secondary outcome. Randomization was accomplished with random permuted blocks of 20 patients with allocation concealed in sequentially numbered, opaque, sealed envelopes. Blinding was applicable for outcome assessment only. Patients were reviewed at 1, 3, and 6 months and then every 6 months after placement of the retainer until completion of the study. Data were analyzed using survival analysis including Cox regression; sensitivity analysis was carried out after data imputation for subjects lost to follow-up. RESULTS Two hundred twenty patients (median age, 16 years; interquartile range, 2; range, 12-47 years) were randomized in a 1:1 ratio to either chemical or light curing. Baseline characteristics were similar between groups, the median follow-up period was 2.19 years (range, 0.003-3.64 years), and 16 patients were lost to follow-up. At a minimum follow-up of 2 years, 47 of 110 (42.7%) and 55 of 110 (50.0%) retainers had some type of failure with chemically cured and light-cured adhesive, respectively (log-rank test, P = 0.35). Data were analyzed on an intention-to-treat basis, and the hazard ratio (HR) was 1.15 (95% confidence interval [CI], 0.88-1.70; P = 0.47). There was weak evidence that age is a significant predictor for lingual retainer failures (HR, 0.96; 95% CI, 0.93-1.00; P = 0.08). Adhesive remnant index scoring was possible for only 66 of the 102 (64.7%) failures and did not differ between composites (Fisher exact test, P = 0.16). No serious harm was observed other than gingivitis associated with plaque accumulation. CONCLUSIONS The results of this study indicated no evidence that survival of mandibular lingual retainers differs between chemically and light-cured adhesives. The overall failure rate was 46.4%; however, this included any type of failure, which may have exaggerated the overall failure rate.
Resumo:
Two synchronization protocols in lactating dairy and beef cows and in dairy heifers were tested for efficacy of breeding by artificial insemination (AI) with or without estrus detection. Controls received three prostaglandin F2a (PGF2a) injections 14 days apart before AI at observed estrus. Pregnancy rates were compared with animals on the Ovsynch protocol that combined gonadotropin releasing hormone (GnRH) and PGF2a treatments with a timed AI 16 to 20 hours after the second GnRH injection. The pregnancy rates were similar at synchronized ovulation to fixed-time AI in lactating cows, but not effective in heifers because of the lack of synchronization.
Resumo:
This study investigated the contribution of estrogen receptors (ERs) alpha and beta for epicardial coronary artery function, vascular NO bioactivity, and superoxide (O(2)(-)) formation. Porcine coronary rings were suspended in organ chambers and precontracted with prostaglandin F(2alpha) to determine direct effects of the selective ER agonists 4,4',4''-(4-propyl-[(1)H]pyrazole-1,3,5-triyl)tris-phenol (PPT) or 2,3-bis(4-hydroxyphenyl)-propionitrile (DPN) or the nonselective ER agonist 17beta-estradiol. Indirect effects on contractility to U46619 and relaxation to bradykinin were assessed and effects on NO, nitrite, and O(2)(-) formation were measured in cultured cells. Within 5 minutes, selective ERalpha activation by PPT, but not 17beta-estradiol or the ERbeta agonist DPN, caused rapid, NO-dependent, and endothelium-dependent relaxation (49+/-5%; P<0.001 versus ethanol). PPT also caused sustained endothelium- and NO-independent vasodilation similar to 17beta-estradiol after 60 minutes (72+/-3%; P<0.001 versus ethanol). DPN induced endothelium-dependent NO-independent relaxation via endothelium-dependent hyperpolarization (40+/-4%; P<0.01 versus ethanol). 17beta-Estradiol and PPT, but not DPN, attenuated the responses to U46619 and bradykinin. All of the ER agonists increased NO and nitrite formation in vascular endothelial but not smooth muscle cells and attenuated vascular smooth muscle cell O(2)(-) formation (P<0.001). ERalpha activation had the most potent effects on both nitrite formation and inhibiting O(2)(-) (P<0.05). These data demonstrate novel and differential mechanisms by which ERalpha and ERbeta activation control coronary artery vasoreactivity in males and females and regulate vascular NO and O(2)(-) formation. The findings indicate that coronary vascular effects of sex hormones differ with regard to affinity to ERalpha and ERbeta, which will contribute to beneficial and adverse effects of hormone replacement therapy.
Resumo:
Spring sublimation of the seasonal CO2 northern polar cap is a dynamic process in the current Mars climate. Phenomena include dark fans of dune material propelled out onto the seasonal ice layer, polygonal cracks in the seasonal ice, sand flow down slipfaces, and outbreaks of gas and sand around the dune margins. These phenomena are concentrated on the north polar erg that encircles the northern residual polar cap. The Mars Reconnaissance Orbiter has been in orbit for three Mars years, allowing us to observe three northern spring seasons. Activity is consistent with and well described by the Kieffer model of basal sublimation of the seasonal layer of ice applied originally in the southern hemisphere. Three typical weak spots have been identified on the dunes for escape of gas sublimed from the bottom of the seasonal ice layer: the crest of the dune, the interface of the dune with the interdune substrate, and through polygonal cracks in the ice. Pressurized gas flows through these vents and carries out material entrained from the dune. Furrows in the dunes channel gas to outbreak points and may be the northern equivalent of southern radially-organized channels ("araneiform" terrain), albeit not permanent. Properties of the seasonal CO2 ice layer are derived from timing of seasonal events such as when final sublimation occurs. Modification of dune morphology shows that landscape evolution is occurring on Mars today, driven by seasonal activity associated with sublimation of the seasonal CO2 polar cap.
Resumo:
BACKGROUND Current international treatment guidelines recommending therapeutic exercise for people with symptomatic hip osteoarthritis (OA) report are based on limited evidence. OBJECTIVES To determine whether land-based therapeutic exercise is beneficial for people with hip OA in terms of reduced joint pain and improved physical function and quality of life. SEARCH METHODS We searched five databases from inception up to February 2013. SELECTION CRITERIA All randomised controlled trials (RCTs) recruiting people with hip OA and comparing some form of land-based therapeutic exercise (as opposed to exercises conducted in water) with a non-exercise group. DATA COLLECTION AND ANALYSIS Four review authors independently selected studies for inclusion. We resolved disagreements through consensus. Two review authors independently extracted data, assessed risk of bias and the quality of the body of evidence for each outcome using the GRADE approach. We conducted analyses on continuous outcomes (pain, physical function and quality of life) and dichotomous outcomes (proportion of study withdrawals). MAIN RESULTS We considered that seven of the 10 included RCTs had a low risk of bias. However, the results may be vulnerable to performance and detection bias as none of the RCTs were able to blind participants to treatment allocation and, while most RCTs reported blinded outcome assessment, pain, physical function and quality of life were participant self reported. One of the 10 RCTs was only reported as a conference abstract and did not provide sufficient data for the evaluation of bias risk.High-quality evidence from nine trials (549 participants) indicated that exercise reduced pain (standardised mean difference (SMD) -0.38, 95% confidence interval (CI) -0.55 to -0.20) and improved physical function (SMD -0.38, 95% CI -0.54 to -0.05) immediately after treatment. Pain and physical function were estimated to be 29 points on a 0- to 100-point scale (0 was no pain or loss of physical function) in the control group; exercise reduced pain by an equivalent of 8 points (95% CI 4 to 11 points; number needed to treat for an additional beneficial outcome (NNTB) 6) and improved physical function by an equivalent of 7 points (95% CI 1 to 12 points; NNTB 6). Only three small studies (183 participants) evaluated quality of life, with overall low quality evidence, with no benefit of exercise demonstrated (SMD -0.07, 95% CI -0.23 to 0.36). Quality of life was estimated to be 50 points on a norm-based mean (standard deviation (SD)) score of 50 (10) in the general population in the control group; exercise improved quality of life by 0 points. Moderate-quality evidence from seven trials (715 participants) indicated an increased likelihood of withdrawal from the exercise allocation (event rate 6%) compared with the control group (event rate 3%), but this difference was not significant (risk difference 1%; 95% CI -1% to 4%). Of the five studies reporting adverse events, each study reported only one or two events and all were related to increased pain attributed to the exercise programme.The reduction in pain was sustained at least three to six months after ceasing monitored treatment (five RCTs, 391 participants): pain (SMD -0.38, 95% CI -0.58 to -0.18). Pain was estimated to be 29 points on a 0- to 100-point scale (0 was no pain) in the control group, the improvement in pain translated to a sustained reduction in pain intensity of 8 points (95% CI 4 to 12 points) compared with the control group (0 to 100 scale). The improvement in physical function was also sustained (five RCTs, 367 participants): physical function (SMD -0.37, 95% CI -0.57 to -0.16). Physical function was estimated to be 24 points on a 0- to 100-point scale (0 was no loss of physical function) in the control group, the improvement translated to a mean of 7 points (95% CI 4 to 13) compared with the control group.Only five of the 10 RCTs exclusively recruited people with symptomatic hip OA (419 participants). There was no significant difference in pain or physical function outcomes compared with five studies recruiting participants with hip or knee OA (130 participants). AUTHORS' CONCLUSIONS Pooling the results of these 10 RCTs demonstrated that land-based therapeutic exercise programmes can reduce pain and improve physical function among people with symptomatic hip OA.
Resumo:
BACKGROUND AND PURPOSE The DRAGON score predicts functional outcome in the hyperacute phase of intravenous thrombolysis treatment of ischemic stroke patients. We aimed to validate the score in a large multicenter cohort in anterior and posterior circulation. METHODS Prospectively collected data of consecutive ischemic stroke patients who received intravenous thrombolysis in 12 stroke centers were merged (n=5471). We excluded patients lacking data necessary to calculate the score and patients with missing 3-month modified Rankin scale scores. The final cohort comprised 4519 eligible patients. We assessed the performance of the DRAGON score with area under the receiver operating characteristic curve in the whole cohort for both good (modified Rankin scale score, 0-2) and miserable (modified Rankin scale score, 5-6) outcomes. RESULTS Area under the receiver operating characteristic curve was 0.84 (0.82-0.85) for miserable outcome and 0.82 (0.80-0.83) for good outcome. Proportions of patients with good outcome were 96%, 93%, 78%, and 0% for 0 to 1, 2, 3, and 8 to 10 score points, respectively. Proportions of patients with miserable outcome were 0%, 2%, 4%, 89%, and 97% for 0 to 1, 2, 3, 8, and 9 to 10 points, respectively. When tested separately for anterior and posterior circulation, there was no difference in performance (P=0.55); areas under the receiver operating characteristic curve were 0.84 (0.83-0.86) and 0.82 (0.78-0.87), respectively. No sex-related difference in performance was observed (P=0.25). CONCLUSIONS The DRAGON score showed very good performance in the large merged cohort in both anterior and posterior circulation strokes. The DRAGON score provides rapid estimation of patient prognosis and supports clinical decision-making in the hyperacute phase of stroke care (eg, when invasive add-on strategies are considered).
Resumo:
BACKGROUND Acetabular retroversion is associated with pincer-type femoroacetabular impingement and can lead to hip osteoarthritis. We report the ten-year results of a previously described patient cohort that had corrective periacetabular osteotomy for the treatment of symptomatic acetabular retroversion. METHODS Clinical and radiographic parameters were assessed preoperatively and at two and ten years postoperatively. A Kaplan-Meier survivorship analysis of the twenty-two patients (twenty-nine hips) with a mean follow-up (and standard deviation) of 11 ± 1 years (range, nine to twelve years) was performed. In addition, a univariate Cox regression analysis was done with conversion to total hip arthroplasty as the primary end point and progression of the osteoarthritis, a fair or poor result according to the Merle d'Aubigné score, or the need for revision surgery as the secondary end points. RESULTS The mean Merle d'Aubigné score improved significantly from 14 ± 1.4 points (range, 12 to 17 points) preoperatively to 16.9 ± 0.9 points (range, 15 to 18 points) at ten years (p < 0.001). There were also significant improvements with regard to hip flexion (p = 0.003), internal rotation (p = 0.003), and adduction (p = 0.002) compared with the preoperative status. No significant increase of the mean Tönnis osteoarthritis score was seen at ten years (p = 0.06). The cumulative ten-year survivorship, with conversion to a total hip arthroplasty as the primary end point, was 100%. The cumulative ten-year survivorship in achievement of one of the secondary end points was 71% (95% confidence interval, 54% to 88%). Predictors for poor outcome were the lack of femoral offset creation and overcorrection of the acetabular version resulting in excessive anteversion. CONCLUSIONS Anteverting periacetabular osteotomy for acetabular retroversion leads to favorable long-term results with preservation of the native hip at a mean of ten years. Overcorrection resulting in excessive anteversion of the hip and omitting concomitant offset creation of the femoral head-neck junction are associated with an unfavorable outcome.
Resumo:
High concentrations of HDL cholesterol are considered to indicate efficient reverse cholesterol transport and to protect from atherosclerosis. However, HDL has been suggested to be dysfunctional in ESRD. Hence, our main objective was to investigate the effect of HDL cholesterol on outcomes in maintenance hemodialysis patients with diabetes. Moreover, we investigated the associations between the major protein components of HDL (apoA1, apoA2, and apoC3) and end points. We performed an exploratory, post hoc analysis with 1255 participants (677 men and 578 women) of the German Diabetes Dialysis study. The mean age was 66.3 years and the mean body mass index was 28.0 kg/m(2). The primary end point was a composite of cardiac death, myocardial infarction, and stroke. The secondary end point included all-cause mortality. The mean duration of follow-up was 3.9 years. A total of 31.3% of the study participants reached the primary end point and 49.1% died from any cause. HDL cholesterol and apoA1 and apoC3 quartiles were not related to end points. However, there was a trend toward an inverse association between apoA2 and all-cause mortality. The hazard ratio for death from any cause in the fourth quartile compared with the first quartile of apoA2 was 0.63 (95% confidence interval, 0.40 to 0.89). The lack of an association between HDL cholesterol and cardiovascular risk may support the concept of dysfunctional HDL in hemodialysis. The possible beneficial effect of apoA2 on survival requires confirmation in future studies.
Resumo:
BackgroundNiemann-Pick disease type C (NP-C) is a rare autosomal recessive disorder of lysosomal cholesterol transport. The objective of this retrospective cohort study was to critically analyze the onset and time course of symptoms, and the clinical diagnostic work-up in the Swiss NP-C cohort.MethodsClinical, biochemical and genetic data were assessed for 14 patients derived from 9 families diagnosed with NP-C between 1994 and 2013. We retrospectively evaluated diagnostic delays and period prevalence rates for neurological, psychiatric and visceral symptoms associated with NP-C disease. The NP-C suspicion index was calculated for the time of neurological disease onset and the time of diagnosis.ResultsThe shortest median diagnostic delay was noted for vertical supranuclear gaze palsy (2y). Ataxia, dysarthria, dysphagia, spasticity, cataplexy, seizures and cognitive decline displayed similar median diagnostic delays (4¿5y). The longest median diagnostic delay was associated with hepatosplenomegaly (15y). Highest period prevalence rates were noted for ataxia, dysarthria, vertical supranuclear gaze palsy and cognitive decline. The NP-C suspicion index revealed a median score of 81 points in nine patients at the time of neurological disease onset which is highly suspicious for NP-C disease. At the time of diagnosis, the score increased to 206 points.ConclusionA neurologic-psychiatric disease pattern represents the most characteristic clinical manifestation of NP-C and occurs early in the disease course. Visceral manifestation such as isolated hepatosplenomegaly often fails recognition and thus highlights the importance of a work-up for lysosomal storage disorders. The NP-C suspicion index emphasizes the importance of a multisystem evaluation, but seems to be weak in monosymptomatic and infantile NP-C patients.
Resumo:
Demonstration of survival and outcome of progressive multifocal leukoencephalopathy (PML) in a 56-year-old patient with common variable immunodeficiency, consisting of severe hypogammaglobulinemia and CD4+ T lymphocytopenia, during continuous treatment with mirtazapine (30 mg/day) and mefloquine (250 mg/week) over 23 months. Regular clinical examinations including Rankin scale and Barthel index, nine-hole peg and box and block tests, Berg balance, 10-m walking tests, and Montreal Cognitive Assessment (MoCA) were done. Laboratory diagnostics included complete blood count and JC virus (JCV) concentration in cerebrospinal fluid (CSF). The noncoding control region (NCCR) of JCV, important for neurotropism and neurovirulence, was sequenced. Repetitive MRI investigated the course of brain lesions. JCV was detected in increasing concentrations (peak 2568 copies/ml CSF), and its NCCR was genetically rearranged. Under treatment, the rearrangement changed toward the archetype sequence, and later JCV DNA became undetectable. Total brain lesion volume decreased (8.54 to 3.97 cm(3)) and atrophy increased. Barthel (60 to 100 to 80 points) and Rankin (4 to 2 to 3) scores, gait stability, and box and block (7, 35, 25 pieces) and nine-hole peg (300, 50, 300 s) test performances first improved but subsequently worsened. Cognition and walking speed remained stable. Despite initial rapid deterioration, the patient survived under continuous treatment with mirtazapine and mefloquine even though he belongs to a PML subgroup that is usually fatal within a few months. This course was paralleled by JCV clones with presumably lower replication capability before JCV became undetectable. Neurological deficits were due to PML lesions and progressive brain atrophy.
Resumo:
Abstract: Near-infrared spectroscopy (NIRS) enables the non-invasive measurement of changes in hemodynamics and oxygenation in tissue. Changes in light-coupling due to movement of the subject can cause movement artifacts (MAs) in the recorded signals. Several methods have been developed so far that facilitate the detection and reduction of MAs in the data. However, due to fixed parameter values (e.g., global threshold) none of these methods are perfectly suitable for long-term (i.e., hours) recordings or were not time-effective when applied to large datasets. We aimed to overcome these limitations by automation, i.e., data adaptive thresholding specifically designed for long-term measurements, and by introducing a stable long-term signal reconstruction. Our new technique (“acceleration-based movement artifact reduction algorithm”, AMARA) is based on combining two methods: the “movement artifact reduction algorithm” (MARA, Scholkmann et al. Phys. Meas. 2010, 31, 649–662), and the “accelerometer-based motion artifact removal” (ABAMAR, Virtanen et al. J. Biomed. Opt. 2011, 16, 087005). We describe AMARA in detail and report about successful validation of the algorithm using empirical NIRS data, measured over the prefrontal cortex in adolescents during sleep. In addition, we compared the performance of AMARA to that of MARA and ABAMAR based on validation data.