979 resultados para percutaneous mitral balloon valvuloplasty
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
HIBISCUS is a project for studying the dynamics, microphysics and chemistry of the Tropical Tropopause Layer based on balloon measurements. Thirteen heavy sondes and 18 short duration balloons of different types have been used for local process studies. Eight superpressure (BP) and 3 Infra Red Montgolfier (MIR) long duration balloons have been flown for extending the investigations at global scale around the world. Overall the campaign has been very successful operationally as well as scientifically. The paper provides a description of the balloons, the instruments and the strategy used for meeting at best the goals of the project.
Resumo:
Objective: To report the outcome of partial external mitral annuloplasty in dogs with congestive heart failure (CHF) due to mitral regurgitation caused by myxomatous mitral valve degeneration (MMVD). Animals, materials and methods: Nine client-owned dogs with CHF due to mitral regurgitation caused by MMVD. Surgery consisted of a double row of pledget-butressed continuous suture lines placed into the left ventricle parallel and just ventral to the atrioventricular groove between the subsinuosal branch of the left circumflex coronary artery and the paraconal branch of the left coronary artery. Results: Two dogs died during surgery because of severe hemorrhage. Two dogs died 12 and 36 h after surgery because of acute myocardial infarction. Three dogs were euthanized 2 and 4 weeks after surgery because of progression of CHF, 1 was euthanized 30 days after surgery for non-cardiac disease, and 1 survived for 48 months. In the 5 dogs that survived to discharge there was no significant change in the left atrium to aortic ratio with surgery (3.6 ± 0.56 before surgery; 3.1 ± 0.4 after surgery; p = 0.182), and no significant change in mitral regurgitant fraction in 4 dogs in which this measurement was made (78.7 ± 2.0% before surgery; 68.7 ± 7.5% after surgery; p = 0.09). Conclusions: Partial external mitral annuloplasty in dogs with CHF due to MMVD was associated with high perioperative mortality and most dogs that survived to discharge failed to show clinically relevant palliation from this procedure. Consequently, partial external mitral annuloplasty is not a viable option for dogs with mitral regurgitation due to MMVD that has progressed to the stage of CHF. © 2011 Elsevier B.V. All rights reserved.
Resumo:
Myxomatous mitral valve degeneration (MMVD) or endocardiosis is a heart valve disease that occurs in many mammalian species, especially in humans, dogs and pigs. Nitric oxide (NO) plays an important role in the MMVD development. NO can be indirectly evaluated by the nitric-oxide synthase (NOS) expression and by the histochemical reaction of nicotinamide adenine dinucleotide phosphate-diaphorase (NADPH-d). The aim of this study was to evaluate NOS activity, by NADPH-d reaction, in the anterior leaflet of dogs with regular mitral valves and in those with MMVD, as well as in young swine and old females, comparing the reaction level with the degree of endocardiosis disease and also the histological alterations. Twelve mitral valves of dogs and 22 of swine were used for the research. All the valves were macroscopically analyzed for the occurrence or not of endocardiosis. They were fixed in a 4% paraformaldehyde, exposed to NADPH-d reaction, routinely processed and microscopically evaluated for the detection of mucopolysaccharides (MPS) deposition, collagen degeneration, fibrosis and level of endocardiosis. In dogs, relation was observed between higher intensity of the NADPH-d reaction, higher endocardiosis degree, MPS deposition as well as the collagen degeneration. No alteration in color was observed in pigs ́ valves during NADPH-d reaction. In conclusion, NO works in canine mitral valve remodeling extracellular matrix and plays an important role in endocardiosis disease. In swine, the lack of reaction reinforces the absence of macroscopical endocardiosis lesions, suggesting restrict NO action or major differences in the structures of swine valves.
Resumo:
This study aimed to assess the effect of percutaneous transthoracic lung biopsy on the oxidative metabolism of sheep by measuring the oxidative stress markers of superoxide dismutase (SOD), total glutathione (GSH-t), peroxidase (GSH-Px) and thiobarbituric acid reactive substances (TBARS) in the red cells of these animals. Blood samples were collected from 20 clinically healthy sheep prior to, and 30 min after, percutaneous transthoracic lung biopsy. After biopsy, there was a significant decrease (p < 0.05) in SOD and GSH-Px activity, with no significant change (p ≥ 0.05) in GSH-t and TBARS concentrations. These results showed that percutaneous transthoracic lung biopsy did not significantly affect the oxidative metabolism of sheep 30 min after the procedure, which may be used widely in this species without causing serious tissue damage. © 2012. The Authors.
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Resumo:
Introdução: Pacientes portadores de próteses valvares cardíacas mecânicas devem medicados continuamente com anticoagulantes orais para evitar acidentes tromboembólicos. Estes pacientes são avaliados continuamente para o controle da anticoagulação oral. Objetivo: Comparar a ocorrência de complicações tromboembólicas e hemorrágicas em portadores de próteses valvares cardíacas mecânicas de um (mono) e de dois (bi) folhetos na posição mitral em terapêutica anticoagulante. Métodos: Foram estudados, no intervalo de 10 anos, 117 pacientes portadores de prótese na posição mitral, sendo 48 com próteses de folheto único e 69 de folheto duplo. Avaliou-se a ocorrência de complicações tromboembólicas e hemorrágicas de grau maior e menor de acordo com a gravidade. Os resultados estão apresentados sob forma de estudo atuarial e de frequência linearizada de ocorrência de eventos. Resultados: As curvas atuariais mostraram que, ao longo do tempo, os pacientes portadores de próteses valvares monofolheto estiveram menos livres de complicações tromboembólicas que os pacientes com próteses bifolheto, enquanto que, estes últimos (bifolheto) estiveram menos livres de acidentes hemorrágicos. As frequências linearizadas de ocorrência para tromboembolismo foram maiores nos pacientes com próteses monofolheto. Nos episódios hemorrágicos as taxas foram maiores para os portadores de próteses bifolheto. Conclusão: Os portadores de próteses valvares cardíacas monofolheto mostraram-se mais propensos à ocorrência de acidentes tromboembólicos graves em relação aos com próteses bi folheto. Os pacientes com prótese bifolheto apresentaram maior sangramento que os pacientes com prótese monofolheto, no entanto, esta diferença se restringiu aos sangramentos de pouca gravidade.
Resumo:
A good catheter implantation technique is important to allow effective peritoneal access function and long-term technique survival. Studies regarding results obtained by nephrologists in comparison with different techniques have been limited. The aim of this study was to investigate the rate of early catheter-related complications and catheter survival in two Brazilian centers, according to two different percutaneous methods of catheter implantation performed by nephrologist team. Adult incident patients recruited from January 2006 to July 2013 having undergone first peritoneal dialysis (PD) catheter implantation were included in the analysis. Mechanical and infectious early complication rates were defined as time to the first event occurring up to 3 months. Four hundred and forty-five consecutive Tenckhoff catheters were implanted by nephrologist team percutaneously after antibiotic prophylaxis in an operating room: trocar was used in 349 (78.4 %) and Seldinger technique (ST) in 99 (21.6 %). The ST was significantly associated with a lower rate of leak (16.3 vs 3 %, p = 0.03) and outflow failure due to tip catheter migration (22.6 vs 10.1 %, p = 0.04), while early infectious complication rates were similar between the two groups (p = 0.59). Long-term catheter survival was higher in Seldinger group (log-rank, p = 0.031). By Cox multivariate analysis, adjusted for age, sex, and diabetes, the ST remained independently associated with better catheter survival [HR 0.681 (0.462-0.910), p = 0.04]. As conclusion, our experience showed better PD outcomes with the ST than trocar method of catheter implantation by nephrologist.
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Resumo:
Pós-graduação em Medicina Veterinária - FCAV