985 resultados para nanocapsules, enzyme-responsive materials
Resumo:
Dissertação para obtenção do Grau de Doutor em Ciências da Educação
Resumo:
Dissertação para obtenção do Grau de Mestre em Conservação e Restauro
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics
Two competitive enzyme immunoassays for the detection of IgG class antibodies to hepatitis a antigen
Resumo:
Two competitive enzyme immunoassays (EIA) techniques were developed: in the first (COMP-1), test sera were added together with HAV antigen on anti-HAV IgG-coated wells followed by an anti-HA VHRP conjugate; in the second (COMP-2), test sera and anti-HA VHRP conjugate competed for HAV epitopes previously adsorbed to anti-HA V IgG-coated wells. Both procedures used tetramethylbenzidine (TMB) as a substrate. Both competitive tests were shown to be reproducible and suitable for routine diagnosis and research purposes.
Resumo:
Dissertação para obtenção do Grau de Doutor em Ciência e Engenharia de Materiais
Resumo:
The liver abscess is the most frequent extraintestinal complication of intestinal amoebiasis: its diagnosis is suggested by the clinical picture but it must be confirmed by paraclinic tests. Themost stringent diagnosis requires identification of E. histolytica. But this is possible only in a few cases. Serological tests greatly improve the diagnosis of this severe complication of amoebiasis. We compared the Enzyme Linfed Immunosorbent Assay and the Counterimmunoeletrophoresis techniques. Both techniques were used to detect amoebic antibodies in 50 control patients, 30 patients with liver abscess and 30 patients with intestinal amoebiasis. All the sera from control patients gave negative results iin both techniques. When analysing the sera from patients with intestinal amoebiasis, 10% of them were positive by ELISA but non by CIE. The sera of patients with liver abscess, we found that 90% were positive by the ELISA method and 66.6% by the CIE technique. In patients with amoebic liver abscess, the results showed that the ELISA was more sensitive than the CIE, as it presented a higher sensitivity (100%) than that of the CIE technique (66%).
Resumo:
HERITAGE 2008 - World Heritage and Sustainable Development. Barcelos: Green Lines Institute for Sustainable Development, Vol. 2, p. 571-579
Resumo:
The influence of time and temperature on the storage of an alkaline antigen of L.major-like and L.(V.) braziliensis promastigotes added or not of a proteases inhibitor (PMSF) was evaluted by means of an IgG-ELISA. Antibodies in assays using L. major-like antigen stored at -20oC for 6 monsths had a statistically lower geometric mean titer (GMT) and different 95% confidence interval limits (CL) than antigens stored otherwise, as assessed by the "t" statistic. The PMSF L. major-like antigen after storage for 6 months at a temperature of 4oC had the same GMT and 95% CL displayed at time zero as well as when storage for 4 and 6 months at -20oC. Significant diferences were not found when L.(V.) braziliensis antigens were stored at times and temperatures mentioned; the PMSF antigen stored for 2 months at -70oC resulted in a lower serum GMT and 95% CL than any other, as assessed by the "t" statistic. Antigen performance did not show any statistical difference associated to the addition of PMSF within the same species; the largest difference between antigens was that between PMSF-L. (V.) braziliensis and L. major-like without PMSF.
Resumo:
Dacron and nitrocellulose were evaluated as matrices for the dot enzyme linked immunosorbent assay (dot-ELISA) for schistosomiasis and compared to indirect immunofluorescence (IMF). Titration of sera from 18 schistosomiasis patients against soluble worm antigen preparation (SWAP) was carried out and sera from healthy individuals from non-endemic areas were used as controls. The IMF was less sensitive than the dot-ELISAs, although the difference was not statistically significant (p > 0.05). The dot-ELISA based on nitrocellulose was as sensitive as that using dacron. Stability did not differ between nitrocellulose and dacron. Specificity was lower when dacron was used than when nitrocellulose was used, although the difference was not statistically significant (p > 0.05). In conclusion, this work showed that nitrocellulose and dacron performed similarly in dot-ELISA, suggesting that they may be used alternatively in population surveillance in endemic areas.
Resumo:
Dissertation presented to obtain the Ph.D degree in Engineering Sciences and Technology.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Mecânica
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente Perfil de Engenharia de Sistemas Ambientais
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Informática
Resumo:
The main objective of this work was the development of polymeric structures, gel and films, generated from the dissolution of the Chitin-Glucan Complex (CGC) in biocompatible ionic liquids for biomedical applications. Similar as chitin, CGC is only soluble in some special solvents which are toxic and corrosive. Due to this fact and the urgent development of biomedical applications, the need to use biocompatible ionic liquids to dissolve the CGC is indispensable. For the dissolution of CGC, the biocompatible ionic liquid used was Choline acetate. Two different CGC’s, KiOnutrime from KitoZyme and biologically produced CGC from Faculdade de Ciencias e Tecnologia (FCT) - Universidade Nova de Lisboa, were characterized in order to develop biocompatible wound dressing materials. The similar result is shown in term of the ratio of chitin:glucan, which is 1:1.72 for CGC-FCT and 1:1.69 for CGC-Commercial. For the analysis of metal element content, water and inorganic salts content and protein content, both polymers showed some discrepancies, where the content in CGC-FCT is always higher compared to the commercial one. The different characterization results between CGC-FCT and CGC-Commercial could be addressed to differences in the purification method, and the difference of its original strain yeast, whereas CGC-FCT is derived from P.pastoris and the commercial CGC is from A.niger. This work also investigated the effect of biopolymers, temperature dissolution, non-solvent composition on the characteristics of generated polymeric structure with biocompatible ionic liquid. The films were prepared by casting a polymer mixture, immersion in a non-solvent, followed by drying at ambient temperature. Three different non-solvents were tested in phase inversion method, i.e. water, methanol, and glycerol. The results indicate that the composition of non-solvent in the coagulation bath has great influence in generated polymeric structure. Water was found to be the best coagulant for producing a CGC polymeric film structure. The characterizations that have been done include the analysis of viscosity and viscoelasticity measurement, as well as sugar composition in the membrane and total sugar that was released during the phase inversion method. The rheology test showed that both polymer mixtures exhibit a non- Newtonian shear thinning behaviour. Where the viscosity and viscoelasticity test reveal that CGCFCT mixture has a typical behaviour of a viscous solution with entangled polymer chains and CGCCommercial mixture has true gel behaviour. The experimental results show us that the generated CGC solution from choline acetate could be used to develop both polymeric film structure and gel. The generated structures are thermally stable at 100° C, and are hydrophilic. The produced films have dense structure and mechanical stabilities against puncture up to 60 kPa.
Resumo:
Portuguese Science Foundation - project Electra PTDC/CTM/099124/2008 and the PhD grant SFRH/BD/45224. financial support: Professor E. Fortunato’s ERC 2008 Advanced Grant (INVISIBLE contract number 228144), “APPLE” FP7-NMP-2010-SME/262782-2 and “SMARTEC” FP7-ICT-2009.3.9/258203