888 resultados para modelling of dynamics


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Society, as we know it today, is completely dependent on computer networks, Internet and distributed systems, which place at our disposal the necessary services to perform our daily tasks. Moreover, and unconsciously, all services and distributed systems require network management systems. These systems allow us to, in general, maintain, manage, configure, scale, adapt, modify, edit, protect or improve the main distributed systems. Their role is secondary and is unknown and transparent to the users. They provide the necessary support to maintain the distributed systems whose services we use every day. If we don’t consider network management systems during the development stage of main distributed systems, then there could be serious consequences or even total failures in the development of the distributed systems. It is necessary, therefore, to consider the management of the systems within the design of distributed systems and systematize their conception to minimize the impact of the management of networks within the project of distributed systems. In this paper, we present a formalization method of the conceptual modelling for design of a network management system through the use of formal modelling tools, thus allowing from the definition of processes to identify those responsible for these. Finally we will propose a use case to design a conceptual model intrusion detection system in network.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We perform a detailed modelling of the post-outburst surface emission of the low magnetic field magnetar SGR 0418+5729. The dipolar magnetic field of this source, B=6×1012G estimated from its spin-down rate, is in the observed range of magnetic fields for normal pulsars. The source is further characterized by a high pulse fraction and a single-peak profile. Using synthetic temperature distribution profiles, and fully accounting for the general-relativistic effects of light deflection and gravitational redshift, we generate synthetic X-ray spectra and pulse profiles that we fit to the observations. We find that asymmetric and symmetric surface temperature distributions can reproduce equally well the observed pulse profiles and spectra of SGR 0418. None the less, the modelling allows us to place constraints on the system geometry (i.e. the angles ψ and ξ that the rotation axis makes with the line of sight and the dipolar axis, respectively), as well as on the spot size and temperature contrast on the neutron star surface. After performing an analysis iterating between the pulse profile and spectra, as done in similar previous works, we further employed, for the first time in this context, a Markov-Chain Monte Carlo approach to extract constraints on the model parameters from the pulse profiles and spectra, simultaneously. We find that, to reproduce the observed spectrum and flux modulation: (a) the angles must be restricted to 65° ≲ ψ + ξ ≲ 125° or 235° ≲ ψ + ξ ≲ 295°; (b) the temperature contrast between the poles and the equator must be at least a factor of ∼6, and (c) the size of the hottest region ranges between 0.2 and 0.7 km (including uncertainties on the source distance). Lastly, we interpret our findings within the context of internal and external heating models.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present work, a three-dimensional (3D) formulation based on the method of fundamental solutions (MFS) is applied to the study of acoustic horns. The implemented model follows and extends previous works that only considered two-dimensional and axisymmetric horn configurations. The more realistic case of 3D acoustic horns with symmetry regarding two orthogonal planes is addressed. The use of the domain decomposition technique with two interconnected sub-regions along a continuity boundary is proposed, allowing for the computation of the sound pressure generated by an acoustic horn installed on a rigid screen. In order to reduce the model discretization requirements for these cases, Green’s functions derived with the image source methodology are adopted, automatically accounting for the presence of symmetry conditions. A strategy for the calculation of an optimal position of the virtual sources used by the MFS to define the solution is also used, leading to improved reliability and flexibility of the proposed method. The responses obtained by the developed model are compared to reference solutions, computed by well-established models based on the boundary element method. Additionally, numerically calculated acoustic parameters, such as directivity and beamwidth, are compared with those evaluated experimentally.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Solar heating of potable water has traditionally been accomplished through the use of solar thermal (ST) collectors. With the recent increases in availability and lower cost of photovoltaic (PV) panels, the potential of coupling PV solar arrays to electrically heated domestic hot water (DHW) tanks has been considered. Additionally, innovations in the SDHW industry have led to the creation of photovoltaic/thermal (PV/T) collectors, which heat water using both electrical and thermal energy. The current work compared the performance and cost-effectiveness of a traditional solar thermal (ST) DHW system to PV-solar-electric DHW systems and a PV/T DHW system. To accomplish this, a detailed TRNSYS model of the solar hot water systems was created and annual simulations were performed for 250 L/day and 325 L/day loads in Toronto, Vancouver, Montreal, Halifax, and Calgary. It was shown that when considering thermal performance, PV-DHW systems were not competitive when compared to ST-DHW and PVT-DHW systems. As an example, for Toronto the simulated annual solar fractions of PV-DHW systems were approximately 30%, while the ST-DHW and PVT-DHW systems achieved 65% and 71% respectively. With current manufacturing and system costs, the PV-DHW system was the most cost-effective system for domestic purposes. The capital cost of the PV-DHW systems were approximately $1,923-$2,178 depending on the system configuration, and the ST-DHW and PVT system were estimated to have a capital cost of $2,288 and $2,373 respectively. Although the capital cost of the PVT-DHW system was higher than the other systems, a Present Worth analysis for a 20-year period showed that for a 250 L/day load in Toronto the Present Worth of the PV/T system was approximately $4,597, with PV-DHW systems costing approximately $7,683-$7,816 and the ST-DHW system costing $5,238.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Modelling the susceptibility of permafrost slopes to disturbance can identify areas at risk to future disturbance and result in safer infrastructure and resource development in the Arctic. In this study, we use terrain attributes derived from a digital elevation model, an inventory of permafrost slope disturbances known as active-layer detachments (ALDs) and generalised additive modelling to produce a map of permafrost slope disturbance susceptibility for an area on northern Melville Island, in the Canadian High Arctic. By examining terrain variables and their relative importance, we identified factors important for initiating slope disturbance. The model was calibrated and validated using 70 and 30 per cent of a data-set of 760 mapped ALDs, including disturbed and randomised undisturbed samples. The generalised additive model calibrated and validated very well, with areas under the receiver operating characteristic curve of 0.89 and 0.81, respectively, demonstrating its effectiveness at predicting disturbed and undisturbed samples. ALDs were most likely to occur below the marine limit on slope angles between 3 and 10° and in areas with low values of potential incoming solar radiation (north-facing slopes).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Molecular modelling of human CYP1B1 based on homology with the mammalian P450, CYP2C5, of known three-dimensional structure is reported. The enzyme model has been used to investigate the likely mode of binding for selected CYP1B1 substrates, particularly with regard to the possible effects of allelic variants of CYP1B1 on metabolism. In general, it appears that the CYP1B1 model is consistent with known substrate selectivity for the enzyme, and the sites of metabolism can be rationalized in terms of specific contacts with key amino acid residues within the CYP1B1 heme locus. Further-more, a mode of binding interaction for the inhibitor, a-naphthoflavone, is presented which accords with currently available information. The current paper shows that a combination of molecular modelling and experimental determinations on the substrate metabolism for CYP1B1 allelic variants can aid in the understanding of structure-function relationships within P450 enzymes. (C) 2003 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Modelling of froth transportation, as part of modelling of froth recovery, provides a scale-up procedure for flotation cell design. It can also assist in improving control of flotation operation. Mathematical models of froth velocity on the surface and froth residence time distribution in a cylindrical tank flotation cell are proposed, based on mass balance principle of the air entering the froth. The models take into account factors such as cell size, concentrate launder configuration, use of a froth crowder, cell operating conditions including froth height and air rate, and bubble bursting on the surface. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mineralogical analysis is often used to assess the liberation properties of particles. A direct method of estimating liberation is to actually break particles and then directly obtain liberation information from applying mineralogical analysis to each size-class of the product. Another technique is to artificially apply random breakage to the feed particle sections to estimate the resultant distribution of product particle sections. This technique provides a useful alternative estimation method. Because this technique is applied to particle sections, the actual liberation properties for particles can only be estimated by applying stereological correction. A recent stereological technique has been developed that allows the discrepancy between the linear intercept composition distribution and the particle section composition distribution to be used as guide for estimating the particle composition distribution. The paper will show results validating this new technique using numerical simulation. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A finite-difference time-domain (FDTD) thermal model has been developed to compute the temperature elevation in the Sprague Dawley rat due to electromagnetic energy deposition in high-field magnetic resonance imaging (MRI). The field strengths examined ranged from 11.75-23.5 T (corresponding to H-1 resonances of 0.5-1 GHz) and an N-stub birdcage resonator was used to both transmit radio-frequency energy and receive the MRI signals. With an in-plane resolution of 1.95 mm, the inhomogeneous rat phantom forms a segmented model of 12 different tissue types, each having its electrical and thermal parameters assigned. The steady-state temperature distribution was calculated using a Pennes 'bioheat' approach. The numerical algorithm used to calculate the induced temperature distribution has been successfully validated against analytical solutions in the form of simplified spherical models with electrical and thermal properties of rat muscle. As well as assisting with the design of MRI experiments and apparatus, the numerical procedures developed in this study could help in future research and design of tumour-treating hyperthermia applicators to be used on rats in vivo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Solids concentration and particle size distribution gradually change in the vertical dimension of industrial flotation cells, subject primarily to the flotation cell size and design and the cell operating conditions. As entrainment is a two-step process and involves only the suspended solids in the top pulp region near the pulp-froth interface, the solids suspension characteristics have a significant impact on the overall entrainment. In this paper, a classification function is proposed to describe the state of solids suspension in flotation cells, similar to the definition of degree of entrainment for classification in the froth phase found in the literature. A mathematical model for solids suspension is also developed, in which the classification function is expressed as an exponential function of the particle size. Experimental data collected from three different Outokumpu tank flotation cells in three different concentrators are well fitted by the proposed exponential model. Under the prevailing experimental conditions, it was found that the solids content in the top region was relatively independent of cell operating conditions such as froth height and air rate but dependent on the cell size. Moreover, the results obtained from the total solids tend to be similar to those from a particular gangue mineral and hence may be applied to all minerals in entrainment calculation. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of retrofitting an existing pond on removal efficiency and hydraulic performance was modelled using the commercial software Mike21 and compartmental modelling. The Mike21 model had previously been calibrated on the studied pond. Installation of baffles, the addition of culverts under a causeway and removal of an existing island were all studied as possible improvement measures in the pond. The subsequent effect on hydraulic performance and removal of. suspended solids was then evaluated. Copper, cadmium, BOD, nitrogen and phosphorus removal were,also investigated for that specific improvement measure showing the best results. Outcomes of this study reveal that all measures increase the removal efficiency of suspended solids. The hydraulic efficiency is improved for all cases, except for the case where the island is removed. Compartmental modelling was also used to evaluate hydraulic performance and facilitated a better understanding of the way each of the different measures affected the flow pattern and performance. It was concluded that the installation of baffles is the best of the studied measures resulting in a reduction in the annual load on the receiving lake by approximately 8,000 kg of suspended solids (25% reduction of the annual load), 2 kg of copper (10% reduction of the annual load) and 600 kg of BOD (10% reduction of the annual load).