991 resultados para maxillary sinus


Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMo describe the characteristics of paediatric cerebral sinus venous thrombosis (CSVT) in Switzerland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional MRI may still be an inaccurate method for the non-invasive detection of a microadenoma in adrenocorticotropin (ACTH)-dependent Cushing's syndrome (CS). Bilateral inferior petrosal sinus sampling (BIPSS) with ovine corticotropin-releasing hormone (oCRH) stimulation is an invasive, but accurate, intervention in the diagnostic armamentarium surrounding CS. Until now, there is a continuous controversial debate regarding lateralization data in detecting a microadenoma. Using BIPSS, we evaluated whether a highly selective placement of microcatheters without diversion of venous outflow might improve detection of pituitary microadenoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess the changes in inclination of the maxillary second (M2) and third (M3) molars after orthodontic treatment of Class II Division 1 malocclusion with extraction of maxillary first molars.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To analyze maintenance service of fixed maxillary prostheses and overdentures based on conventional gold bars or titanium bars and frameworks fabricated with computer-aided design/computer-assisted manufacture (CAD/CAM) technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: This pilot study evaluated the wound healing and tissue response after placement of two different skin substitutes in subgingival mucosal pouches in rabbits. MATERIALS AND METHODS: Four rabbits were selected to receive a commercially available skin substitute consisting of a collagen matrix with fibroblasts and an epithelial layer (test membrane 1) and a prototype device consisting of a collagen matrix with fibroblasts only (test membrane 2). In each rabbit, two horizontal incisions were made in the buccal alveolar mucosa of the maxilla bilaterally to create submucosal pouches. Three pouches in each animal were filled with either the test 1 or test 2 membranes, and one pouch was left without a membrane (sham-operated control). All rabbits were sacrificed after a healing period of 4 weeks, and histologic samples were prepared and examined. RESULTS: After a healing period of 1 month, both tested membranes were still visible in the sections. Test membrane 1 was still bilayered, contained inflammatory cells in its center, and was encapsulated by a thick fibrous tissue. Numerous ectopic calcifications were evident in the collagenous part of the membrane and in association with some basal epithelial cells. Test membrane 2 was also encapsulated in fibrous tissue, with inflammatory cells present only between the fibrous encapsulation and the remnants of the membrane. For test membrane 2, no calcifications were visible. CONCLUSIONS: Test membrane 1 seemed to be more resistant to degradation, but there was also a more pronounced inflammatory reaction in comparison to test membrane 2, especially in the vicinity of the keratinocytes. The significance of the ectopic calcifications, along with that of the resorption or degradation processes of both tested membranes, must be evaluated in future experimental studies, with different time points after implantation examine

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To analyze the mechanism of overjet correction and space closure when treating Class II Division 1 patients by extracting the maxillary first molars.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate maxillary dental arch dimensions in pre-school children with a complete unilateral cleft lip and palate (CUCLP) after early alveolar bone grafting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this retrospective radiographic study was to analyze the thickness of the facial bone wall at teeth in the anterior maxilla based on cone beam computed tomography (CBCT) images, since this anatomical structure is important for the selection of an appropriate treatment approach in patients undergoing postextraction implant placement. A total of 125 CBCT scans met the inclusion criteria, resulting in a sample size of 498 teeth. The thickness of the facial bone wall in the respective sagittal scans was measured perpendicular to the long axis of the tooth at two locations: at the crest level (4 mm apical to the cementoenamel junction; MP1) and at the middle of the root (MP2). No existing bone wall was found in 25.7% of all teeth at MP1 and in 10.0% at MP2. The majority of the examined teeth exhibited a thin facial bone wall (< 1 mm; 62.9% at MP1, 80.1% at MP2). A thick bone wall (? 1 mm) was found in only 11.4% of all examined teeth at MP1 and 9.8% at MP2. There was a statistically significant decrease in facial bone wall thickness from the first premolars to the central incisors. The facial bone wall in the crestal area of teeth in the anterior maxilla was either missing or thin in roughly 90.0% of patients. Both a missing and thin facial wall require simultaneous contour augmentation at implant placement because of the well-documented bone resorption that occurs at a thin facial bone wall following tooth extraction. Consequently, radiographic analysis of the facial bone wall using CBCT prior to extraction is recommended for selection of the appropriate treatment approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Balloon sinuplasty is a tool that is used to treat selected patients with paranasal sinus pathologies. No studies have investigated the aetiology of failed access to the frontal sinus. The aim of our study was to specify the intraoperative technical failure rate and to analyse the aetiology of the failed access to predict potential technical difficulties before surgery. We retrospectively analysed the charts of patients who underwent balloon sinuplasty from November 2007 to July 2010 at three different ENT-Centres. CT-analysis of the patients with failed access was performed. Of the 104 frontal sinuses, dilation of 12 (12%) sinuses failed. The anatomy of all failed cases revealed variations in the frontal recess (frontoethmoidal-cell, frontal-bulla-cell or agger-nasi-cell) or osteoneogenesis. In one patient, a lymphoma was overlooked during a balloon only procedure. The lymphoma was diagnosed 6 months later with a biopsy during functional endoscopic sinus surgery. In complex anatomical situations of the frontal recess, balloon sinuplasty may be challenging or impossible. In these situations, it is essential to have knowledge of classical functional endoscopic sinus surgery of the frontal recess area. The drawbacks of not including a histopathologic exam should be considered in balloon only procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Healthy, well-structured mucosa may clinically disguise atrophic jawbone in preimplant diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate the thickness and the anatomic characteristics of the Schneiderian membrane and cortical bone using limited cone beam computed tomography (CBCT) scannning in patients referred for planning of apical surgery of maxillary molars.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Falls and fractures in the elderly are among the leading causes of disability. We investigated whether pacemaker implantation prevents falls in patients with SND in a large cohort of patients. Methods. Patient demographics and medical history were collected prospectively. Fall history was retrospectively reconstituted from available medical records. The 10-year probability for major osteoporotic fractures was calculated retrospectively from available medical records using the Swiss fracture risk assessment tool FRAX-Switzerland. Results. During a mean observation period of 2.3 years after implantation, the rates of fallers and injured fallers with fracture were reduced to 15% and 6%, respectively. This corresponds to a relative reduction in the number of fallers of 75% (P < 0.001) and of injured fallers of 63% (P = 0.014) after pacemaker implantation. Similarly, the number of falls was reduced from 60 (48%) before pacemaker implantation to 22 (18%) thereafter (relative reduction 63%, P = 0.035) and the number of falls with injury from 22 (18%) to 7 (6%), which corresponds to a relative reduction of 67%, P = 0.013. Conclusion. In patients with SND, pacemaker implantation significantly reduces the number of patients experiencing falls, the total number of falls, and the risk for osteoporotic fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: In most patients with chronic heart failure (CHF), endurance training improves exercise capacity. However, some patients do not respond favourably. The purpose of this study was to explore the reasons of non-response and to determine their predictive value.Methods: We studied a cohort of 120 consecutive CHF patients with sinus rhythm (mean age 57 ± 12 years, ejection fraction 29.3 ± 9.9%, peak VO2 17.3 ± 5.1 ml/min/kg), participating in a 3-month outpatient cardiac rehabilitation programme. Responders were defined as subjects who improved peak VO2 by more than 5%, work load by more than 10%, or VE/VCO2 slope by more than 5%. Subjects who did not fulfil at least one of the above criteria were characterized as non-responders. Multivariate regression analyses were performed to identify parameters that were predictive for a response. Receiver operating characteristic (ROC) analyses were performed for predictive parameters to identify thresholds for response or non-response.Results: Multivariate regression analyses revealed heart rate (HR) reserve, HR recovery at 1 min, and peak HR as significant predictors for a positive training response. ROC curves revealed the optimal thresholds separating responders from non-responders at less than 30 bpm for HR reserve, less than 6 bpm for HR recovery and less than 101 bpm for peak HR.Conclusions: The presence of impaired chronotropic competence is a major predictor of poor training response in CHF patients with sinus rhythm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the safety and outcomes of mitral isthmus (MI) linear ablation with temporary spot occlusion of the coronary sinus (CS). Background: CS blood flow cools local tissue precluding transmurality and bidirectional block across MI lesion.